Related Manuals for Dyson PH01
Summary of Contents for Dyson PH01
-
Page 1
Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Dyson Pure Humidify + Cool o cerca il tuo prodotto tra le migliori offerte di Trattamento Aria Issued December 19… -
Page 2: Table Of Contents
This manual is written specifically for Dyson trained engineers and covers the full Circulates PH01 and PH02 range. The service instructions assume that the engineer has the approved Air Multiplier technology projects 350 litres of air per second, tools and test equipment with them.
-
Page 3: Product Overview Features And Benefits
HEPA filter to capture 99.95% of ultra fine particles. 4. Wrong Power Supply Unit (PSU) inserted/PSU fault PH01 machine comes with Combination filters. PH02 comes with permanent Cryptomic filters and Combination filters.
-
Page 4: Technical Information
Faults codes will be displayed as per the following format: 00X-0X-0X-X. As well as the UI error symbols, built into PH01 and PH02’s software is an engineers diagnostic In most cases it is only necessary to recognise the first three digits to determine the fault.
-
Page 5: Deep Cleaning The Machine
Deep cleaning the machine PH01 and PH02 have a ‘self cleaning’ cycle built in. This is to reduce limescale build up. In normal use the machine will show an alert when it needs to carry out a Deep clean cycle.
-
Page 6: Testing And Repair Process
General information Electrical safety testing The following tests must be performed prior to and upon completion of all repairs to Dyson products and before any functional checks. You must ensure that a full visual inspection of the product is completed prior to repair.
-
Page 7: Amp Service Assembly — Removal
Repair notes AMP Service Assembly — removal 01 Press the release catches on either side of the filter housings. Remove the filter Housing and Filter assemblies from the product. 04 Carefully lift off the Amp service Note: if the product is a Cryptomic assembly.
-
Page 8
For removal instructions of these parts continue to the next step. Note: not all PCBs are available as spare parts at launch. Always check Dyson Central for 08 To remove the Power button, lever out the two arms and push out the Button, spring and Foam. -
Page 9
09 Push the three grommets through the 12 Remove the Four T-15 screws. neck plate. 13 Release two of the three looms from 10 Remove the six T-8 screws. the large Grommet. 14 Carefully push the large single grommet through the hole in the 11 Remove the plate from the AMP neck assembly. -
Page 10: Amp Service Assembly — Fitting
Repair notes AMP Service Assembly — fitting If the Air Amp Neck Service assembly was previously removed, continue to the next step. If the reason for the repair is to replace the entire Amp Service assembly go to page 20 step 23 — 30. 15 Carefully feed the Grommets 16 Feed the three looms through the and looms through the AMP neck…
-
Page 11
21 Seat the three grommets into the 18 Fit the four T-15 screws. neck plate. 19 Feed the three looms through the neck plate. 22 Locate the foam ring and then the spring into the AMP neck assembly. Ensure the On/Off button is orientated the correct way up. Push the On/Off Button Service assembly 20 Fit the six T-8 screws. -
Page 12
24 Secure the Dust sensor to main controller loom into the retainers provided. 23 Carefully attach the Dust sensor to main controller loom. Locate the Dust Sensor and Dust sensor PCB Service assembly. 25 Reconnect the four Looms. Fit the two long T-8 screws. -
Page 13
26 Secure all Looms into the retainers provided. 27 Line up the LCD with the window on the Neck Service assembly. 28 Fit the eight T-15 screws. Lower the Air Amp Service assembly. -
Page 14: Lower Body Service Assembly — Removal
Repair notes Lower Body Service Assembly — removal Before continuing the following components will need to be removed as previously shown: Air amp service assembly (Pages 10 — 11, steps 01 — 05) 29 Refit the Evaporator assembly. 31 Remove the Water tank. 32 Remove the two T-8 screws in the top of the Filter release catch service assembly.
-
Page 15
37 If the Evaporator door needs replacing, remove the two screws in the top hinge cover and remove the 34 Disconnect the Power loom from the cover. Power controller PCB. 35 Remove the two T-15 screws on the right handside from behind the filter release catch holding at the base. -
Page 16
40 To refit the hinge covers, shut the door. Slide the cover from behind 41 Remove the two T-15 screws. the hinge so the lever folds back into the cover. 42 Remove the two T-8 screws from the Slide the cover forward until the screw underside of the Lower body service bosses line up. -
Page 17: Lower Body Service Assembly — Fitting
Repair notes Lower Body Service Assembly — fitting 44 Release the Power loom from the retainers in the side of the Main body. 45 Lift the Main body away from the 46 Place the Main body on top of the Lower Body Service assembly. Lower body service assembly.
-
Page 18
49 To refit the hinge covers, shut the door. Slide the cover from behind the hinge so the lever folds back into the cover. 48 Fit the two T-8 screws in the underside of the Lower body, and the four T-15 screws to secure the Main body to the Lower Body. -
Page 19
50 Feed the power loom through the hole in the top right hand side of the main body. 53 Ensure the power loom is positioned as shown to avoid trapping. 54 Slide the bottom of the Filter release catch into the details in the Main 51 Connect the Main power loom to the body. -
Page 20: Motor And Bucket Service Assembly — Removal
Repair notes Motor and Bucket Service Assembly — removal Before continuing the following components will need to be removed as previously shown: Air amp service assembly (Pages 10 — 11, steps 01 — 05) 59 Feed the Grommet and connector 56 Disconnect the Motor loom from the Main PCB assembly.
-
Page 21
62 With all three clips released the motor bucket can be removed. Carefully lift the motor bucket up and away from the Main body. 61 Using a blunt screwdriver carefully push the three tabs securing the Motor and Bucket assembly inside the Main body. -
Page 22: Motor And Bucket Service Assembly — Fitting
Repair notes Motor and Bucket Service Assembly — fitting Cross section view of Upper retention ring and spring positions Important: during shipping/transport the Upper, Lower retention rings and springs can detach. Before fitting the Motor and bucket assembly the Upper and Lower Spring retention rings have to be seated on their corresponding ledges on the motor bucket…
-
Page 23
66 Feed the motor loom connector through the hole in the Main body. 65 Push the Motor down until three clicks are heard. 67 Securely seat the motor loom grommet into the hole in the main body. 68 Connect the new motor to the Main PCB. -
Page 24: Connection Shuttle Service Assembly — Removal
Repair notes Connection Shuttle Service Assembly — removal Before continuing the following components will need to be removed as previously shown: Air amp service assembly (Pages 10 — 11, steps 01 — 05) Lower Body Service assembly (page 25 — 30, steps 31 — 35). 70 Remove the Tray Level Harness assembly.
-
Page 25: Connection Shuttle Service Assembly — Fitting
Repair notes Connection Shuttle Service Assembly — fitting 76 Slide the new Connection Shuttle Service assembly into place ensuring all the looms are free from trapping 73 Remove the six T-8 screws holding the tray to the Main body. and no seals have folded over. 74 Disconnect the Shuttle Loom from the Power controller PCB and release the loom from the retainers in the side of…
-
Page 26
79 Position the Connection Shuttle as shown and test it slides freely. 80 Locate the Shuttle Spring and Shuttle Spring Spigot into the hole in the rear of the Connection Shuttle. 78 Firmly locate the two rails on the base of the Water return tray onto the details on the Connection 81 Hold the Spigot firmly whilst carefully Shuttle. -
Page 27: Internal Power Harness Service Assembly — Removal
Repair notes Internal Power Harness Service Assembly — removal Before continuing the following components will need to be removed as previously shown: Air amp service assembly (Pages 10 — 11, steps 01 — 05) Lower Body Service assembly (page 25 — 30, steps 31 — 35). 82 Locate the tray level sensor into the 85 Remove the two T-8 screws holding water return tray.
-
Page 28
88 Unclip the retaing detail at the end of 91 Remove the two T-8 screws securing the skirt from the base. the Socket holder. 89 Remove the two countersunk T-8 92 Remove the Holder and Power screws holding the Base plate. harness. -
Page 29: Internal Power Harness Service Assembly — Fitting
Repair notes Internal Power Harness Service Assembly — fitting 97 Pull the Jack into the holder until it 94 Feed the new Power Harness locks and is flush with the edge as through the right handside of the shown. Lower Body Service assembly. 98 Seat the front of the holder into the 95 Locate the gasket into the hole in the Lower body.
-
Page 30
101 Place the Base plate onto the Lower body. Fit the two countersunk T-8 screws. 99 Press the holder down and fit the two T-8 screws. IMPORTANT: whilst tightening the screws check that the gasket does not become mishapen or the DC Jack misplaced. -
Page 31: Parts Diagram Main Body
Parts diagram Main body Motor Bucket Seal Tail Cone Motor & Bucket Service Assy Tray Level Sensor Assy Internal Input Harness Service Assy Clean Cycle PCB Assy 103 Run the left handside of the Base LCD Display Service Assy Skirt anti-clockwise aroun the base. Clip the securing tab in the base.
-
Page 32: Amp And Filter Assemblies
Parts diagram Amp and Filter assemblies Screw M3x15-P1 Remote Control Assy Air Amp Neck Service Assy Dust Sensor Assy Filter Housing Singular Glass Hepa & Inner Carbon Filter MO…
This manual is also suitable for:
Ph02
Product overview
Features and benefits
Sensor detects and display pollutants and humidity levels
A unique algorithm processes input from each sensor and
activates the machine, to capture pollutants, humidity, and
project cleaner air.
Captures gases and ultra fine particles
The sealed filtration system combines an activates
carbon filter to remove gases and a sealed HEPA
filter to capture 99.95% of ultra fine particles.
PH01 machine comes with Combination filters.
PH02 comes with permanent Cryptomic filters
and Combination filters.
Anti-bacterial evaporator
Silver strands are woven into 3D air mesh of 6mm
intervals.
They help prevent bacteria from growing on the
evaporator.
Destroys potentially harmful bacteria
Dyson Ultraviolet Cleanse technology exposes
every drop of water to an ultraviolet light. This
kills 99.9% of bacteria.
Reflective PTEE tube
Made from a highly reflective material. It
mirrors UV light up and down the tube, to
kill bacteria.
01
Wrong PSU
Broken pump column
Tank missing static
02
Product overview
Display error symbols
The UI screen shows different error icons according to the machine’s status. Many of these are temporary
or can be corrected by carring out a hard reset and/or a software update. To hard reset, switch off the
machine and unplug the mains supply for 20 secs, then plug the machine back in and switch it back on.
Wrong PSU
Broken pump column
Drip tray overflow
Too cold
Clean cycle post clean –
complete
Too cold
Pump rotor failure
Not complete
Tank empty static
1. Temp Sensor fault
2. Humidity Sensor fault
3. Air Quality (AQ) Sensor fault
4. Wrong Power Supply Unit (PSU) inserted/PSU fault
5. Fault. Carry out a Hard reset. If this doesn’t fix the issue check
‘Fault codes’ (pages 5 — 6)
Drip tray overflow
6. Broken pump column. Replace the Pump column assembly
7. Drip tray overflow. Carry out a deep clean cycle (pages 6 -7).
If this doesn’t fix the issue check ‘Fault codes’ (pages 5 — 6)
Pump rotor failure
8. Too cold. Displayed when ambient temperature drops
Clean cycle – insert tank (takeover)
below 5
c and there is water in the tank
o
9. Pump rotor failure. Replace the Pump column assembly
10. Clean cycle not complete. Repeat the clean cycle (pages 6
-7) and allow to run until completion
11. Water tank empty. If not empty, replace the Pump column
assembly
03
Specifications:1834/1834454-ph01.pdf file (20 Jan 2023) |
Accompanying Data:
Dyson PH01 Air Cleaner PDF Service Instructions Manual (Updated: Friday 20th of January 2023 08:06:58 AM)
Rating: 4.6 (rated by 5 users)
Compatible devices: Pure Hot+Cool HP05, purifier cool, Pure Cool Link, purehot+cool link, Pure Hot+Cool HP00, Pure Hot+Cool HP04, pure hot + cool link, PURE COOL ME.
Recommended Documentation:
Text of Service Instructions Manual
(Ocr-Read Version Summary of Contents, UPD: 20 January 2023)
-
7, 02 Remove the Evaporator assembly. Shut the Evaporator door. 01 Press the release catches on either side of the filter housings. Remove the filter Housing and Filter assemblies from the product. Note: if the product is a Cryptomic variant, it won’t be necessary to remove the Cryptomic filter. Repair notes AMP Service Assembly — removal 10 03 Remove the eight T-15 …
-
10, Dyson PH01 15 Carefully feed the Grommets and looms through the AMP neck assembly. 16 16 Feed the three looms through the hole in the neck. 17 Locate the two remaining looms inside the large grommet ensuring the larger loom is located in the centre of the grommet. By pushing from the inside of the neck ensure the large grommet is seated correctly. If the Air Amp Neck Service ass…
-
24, Dyson PH01 69 Fit the Motor to AMP seal. Ensure it is the correct way up and seated around the top of the Motor bucket. 44 After fitting the seal, continuing fitting the following components as previously shown: Air AMP Service assembly (Page 21 — 24, steps 25 — 30) 70 Remove the Tray Level Harness assembly. If the reason for the repair is to replace the Tray Level Harness go to page ?? step…
-
4, 04 05 Technical infomation Accessing the diagnostic menu Diagnostic menu As well as the UI error symbols, built into PH01 and PH02’s software is an engineers diagnostic menu designed to enable the repair agent a quickly diagnosis of the machines failure. The menu is accessed by pressing a sequence of buttons via a standard remote control. Once you have finished accssing the…
-
6, Ensure that at all times during the repair and testing of products that customers, pets, children and you are not exposed to any Live electrical supply. Electrical safety testing Insulation test points: Test directly onto the eight T-10 screws in the Main body. Note: the filters will need to be removed to gain access to the screws. These tests are vital to …
-
1, Issued December 19 Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Dyson Pure Humidify + Cool o cerca il tuo prodotto tra le migliori offerte di Trattamento Aria
… -
22, Repair notes Motor and Bucket Service Assembly — fitting 63 Important: ensure both the Upper and Lower retention rings and all six tension springs are located correctly around the top and bottom of the motor bucket assembly. Failure to do so will result in a failed repair. Top view of motor Bottom view of motor Upper retention ring Cross section view of Up…
-
25, Dyson PH01 73 Remove the six T-8 screws holding the tray to the Main body. 74 Disconnect the Shuttle Loom from the Power controller PCB and release the loom from the retainers in the side of the Main body. 75 Remove the Connection Shuttle Service assembly from the Main body. 46 76 Slide the new Connection Shuttle Service assembly into place ensuring all the looms are free from trap…
-
27, 82 Locate the tray level sensor into the water return tray. 83 Retain the Tray level sensor harness into all the details provided and feed through the top of the Main body. 84 Retain the Shuttle Harness into all details provided and feed through the top of the Main body. 50 After fitting the harness, continuing fitting the following components as previously shown:…
-
3, 01 Product overview Features and benefits 02 03 Product overview Display error symbols Captures gases and ultra fine particles The sealed filtration system combines an activates carbon filter to remove gases and a sealed HEPA filter to capture 99.95% of ultra fine particles. PH01 machine comes with Combination filters. PH02 comes with permanent Cryptomic filters …
Dyson PH01 Recommended Instructions:
MindStorms Robotics Discovery Set 9735, H-8000, cook4me, PREGO 125, L245WP-BN — — 24″ LCD Monitor
-
Karcher
HDS 801 E
Register and win!www.kaercher.com!Deutsch 3English 12Français 21Italiano 31Nederlands 41Español 50Português 60Dansk 70Norsk 79Svenska 88Suomi 97Ελληνικά 106Türkçe 116Руccкий 125Magyar 136Čeština 146Slovenščina 155Polski 164Româneşte 174Slovenčina 184Hrvatski 193Srpski 202Български 211Eesti 221Latviešu 230Lietuviškai 239Українська 249HDS 801 E5. …
HDS 801 E 260
-
cecotec
TOTALPURE CONNECTED 2500
TOTALPURE 2500 / 5000 / 7500 CONNECTED Очищувач повітря / Очиститель воздуха / Air puirfierІнструкція з експлуатації Руководство по эксплуатации Instruction manual05620_05621_05622_TotalPure 2500_5000_7500_ Connected_Manual_YV_01200320.indd 105620_05621_05622_TotalPure 2500_5000_7500 …
TOTALPURE CONNECTED 2500 52
-
LG
PS-V219 Series
www.lg.comOWNER’S MANUALRead before using product (safety instruction), use properly. About ensuring users safety and property. After careful read through the user manual, do keep it in a handy place. Model name : PS-V219 seriesLG Air PurifierP/NO : MFL68181312ENGLISH中国语 …
PS-V219 Series 23
-
Sanuvox
P900-GX
Sanuvox Technologies Inc, © 2019 All rights reserved. February 2020 EN v.1Instruction ManualPhotos illustrating products are non contractual.P900-GXPORTABLE UV AIR PURIFIERResidential ModelIMPORTANT SAFETY INSTRUCTIONSREAD AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.Read and follow all instructions contained in this manual before using the product. Failure to c …
P900-GX 12
-
Coway
APM-1010DH
Coway Air Purier APM-1010DH• This product is for domestic use only. It cannot be used in an overseas country where the power voltage is dierent.• Warranty card is included in this user’s manual.• Read and save these instructions.• English / Français / Español / Deutsch / Italiano / Nederlands / …
APM-1010DH 188
-
Philips
AC4002
Philipsbedroom air purifier•bedroom•30 m²AC4002A healthier sleep, alwaysPurifier with dedicated Sleep modeGet your better night’s sleep with the Philips air purifier. Its dedicated Sleep mode with dimmed indicators quietly cleans the air of bacteria and allergens. The healthy air protect alert and lock assure you of healthy air always.Healthy Air• With advanced filtratio …
AC4002 2
-
cecotec
TOTALPURE 1500 CONNECTED
Інструкція з експлуатації Руководство по эксплуатацииInstruction manual TOTALPURE 1500 CONNECTED Очищувач повітря/Очиститель воздуха/ Air purifier …
TOTALPURE 1500 CONNECTED 14
-
Atlantic Ultraviolet
Hygeaire Air Disinfection
Document No. 98-1137A1 • Revised September 2007 • ©2003-2007 Atlantic Ultraviolet Corporationultraviolet.com375 Marcus Boulevard • Hauppauge, NY 11788 • USA631.273.0500 • Fax: 631.273.0771e-mail: inf[email protected] Product Information Available at: …
Hygeaire Air Disinfection 12
-
Sharp
FP-JC2
*1The technology marking data is based on a unit attached to the passenger seat seatback and a car air conditioning air outlet speed of 4-meters per second (equivalent to the “low” setting) with the product operating at the “standard” setting in the center of the space (0.5m above the oor) to maintain 25000 high dencity plasmacluster ions per cm³. C …
FP-JC2 24
-
Bionaire
BAP600
POWER CORD PLUGIf the plug is not suitable for the socket outlets in your home, it can be removed and replaced by a plug of the correct type. Installation of a plug Applicable to U.K. and Ireland.GUARANTEEPlease keep your receipt as this will be required for any claims under this guarantee.This appliance is guaranteed for 2 years after your purchase as described in this doc …
BAP600 2
Additional Information:
Operating Impressions, Questions and Answers:
Чистое увлажнение + охлаждение 330PH01
Руководство пользователя
Благодарим вас за покупку очистительного и увлажняющего вентилятора Dyson.
Быстрая настройка машины с пошаговой поддержкой
- Персонализируйте свои настройки для максимального комфорта.
- Управляйте своей машиной и следите за ней, где бы вы ни находились.
- Автоматически обновляйте свою машину до последней версии программного обеспечения.
Загрузите приложение Dyson Link
Загрузите приложение Dyson Link из магазина приложений или Google Play.
Откройте приложение и следуйте инструкциям на экране, чтобы создать новую учетную запись.
Для получения дополнительной информации и поддержки: dyson.co.uk 0800 298 0298.
Apple и логотип Apple являются товарными знаками Apple Inc., зарегистрированными в США и других странах. App Store является знаком обслуживания Apple Inc., зарегистрированным в США и других странах.
Google Play и логотип Google Play являются товарными знаками Google Inc.
Активация гарантии
Мы не перестаем заботиться о наших машинах, когда они становятся вашими.
После активации вашей бесплатной двухлетней гарантии на ваш очистительный вентилятор-увлажнитель Dyson будет покрываться запасные части и работа (за исключением фильтров и испарителя) в течение двух лет с даты покупки в соответствии с условиями гарантии.
Даже после истечения срока гарантии мы будем рады помочь.
Бесплатные запчасти и работа Dyson
Беспроблемная замена
Совет эксперта. Семь дней в неделю.
Видео с инструкциями и полезные советы
Ваш серийный номер можно найти на табличке с паспортными данными, которая находится на основании вашей машины.
Запишите свой серийный номер для использования в будущем.
Эта иллюстрация предназначена для бывшегоampтолько для целей.
Сборка вашей машины
Используйте оба хонда, чтобы вытащить очищающий увлажняющий фонарь Dyson из коробки за его упор.
Не поднимайте его ampжизненная петля.
Нажмите кнопки освобождения кожуха с обеих сторон машины, чтобы освободить кожухи.
Когда кожухи будут сняты, внутренняя дверца, в которой находится испаритель, откроется пружиной. Закройте внутреннюю дверцу, убедившись, что она плотно закрывается со щелчком.
Ваш очищающий увлажняющий фонарь Dyson оснащен комбинированным фильтром.
Извлеките комбинированный фильтр из любой защитной упаковки.
Вставьте оба комбинированных фильтра в кожухи, пока защелки сверху и снизу не встанут на место.
Поместите кожухи на место на основном корпусе и осторожно надавите, пока они не встанут на место со щелчком.
Поместите пульт дистанционного управления на машину так, чтобы кнопки были направлены вниз.
Подключите и включите.
Наполнение резервуара для воды
- Перед тем, как снять резервуар для воды, убедитесь, что режимы увлажнения выключены, а резервуар для воды пустой.
- Нажмите кнопки освобождения резервуара для воды на боковых сторонах машины.
- Выдвиньте резервуар для воды из машины.
- Перенесите резервуар для воды за ручку вверх и отсоедините полицейский фиксатор.
- Заполните резервуар для воды до максимального уровня холодной водой.
- Установите на место полицейский и закрепите зажимы крышки на месте.
- Вставьте крышку резервуара для воды в машину до щелчка.
Использование вашей машины
Информация Ману
Нажмите эту кнопку, чтобы просмотреть информацию, отслеживаемую вашим очищающим и увлажняющим вентилятором Dyson.
Информация о качестве воздуха, температуре, влажности. Показаны уровни фильтра и испарителя.
Когда конкретный тип загрязнителя вызывает снижение качества воздуха, на ЖК-экране отображается значок загрязнителя.
Режим автоматической очистки
Установите очищающий увлажняющий фонарь Dyson в режим автоматической очистки, и встроенные датчики будут грамотно регулировать настройки вашей машины в соответствии с качеством воздуха.
Качество воздуха: ваша машина остановится, когда будет достигнуто целевое качество воздуха, и снова включится, когда уровень качества воздуха упадет.
Скорость воздушного потока: скорость воздушного потока будет увеличиваться до тех пор, пока не будут достигнуты заданные качество и температура воздуха.
Ночной режим: ваша машина будет работать только со скоростью воздушного потока от 1 до 4.
Режим автоматического увлажнения
Установите очищающий увлажняющий фонарь Dyson в режим автоматического увлажнения, и встроенные датчики будут грамотно регулировать настройки машины в соответствии с температурой и влажностью в вашей комнате.
Влажность в помещении: ваша машина
будет приостанавливаться при достижении заданной влажности в помещении и снова включаться, когда уровень влажности в помещении падает.
Скорость воздушного потока: скорость воздушного потока будет увеличиваться до тех пор, пока не будет достигнут целевой уровень влажности.
Чтобы выключить режим автоматического увлажнения или изменить уровень влажности вручную, нажмите кнопку управления влажностью.
осцилляция
Нажмите кнопку «Осцилляция» и выберите угол колебания 0 °, 45 °, 90 ° или режим «Ветерок».
Приостановите колебание в любой момент, нажав кнопку колебания.
Для возобновления снова нажмите кнопку «Осцилляция».
Чтобы сбросить направление осцилляции на центр, нажмите и удерживайте кнопку осцилляции в течение двух секунд.
Глубокая чистка вашей машины
Важно: не выключайте и не отключайте машину от сети, поскольку инструкции по очистке будут отображаться на ЖК-экране.
Чтобы ваш очищающий и увлажняющий вентилятор Dyson всегда работал с максимальной эффективностью, важно проводить регулярную глубокую очистку, чтобы удалить известковый налет.
До и после длительных периодов, когда увлажнение не используется, рекомендуется выполнить дополнительные циклы глубокой очистки.
В регионах с жесткой водой может потребоваться более частый запуск цикла глубокой очистки. Мы рекомендуем использовать фильтрованную воду, чтобы ваша машина всегда работала максимально эффективно.
Ваша машина предупредит вас, когда вам потребуется выполнить цикл глубокой очистки.
Если вы подключены к Dyson Link opp, вы получите уведомление.
Если вы не используете Dyson Link opp, ЖК-экран вашей машины предупредит вас, и загорится кнопка цикла глубокой очистки.
Чтобы отменить цикл глубокой очистки в любой момент, нажмите и удерживайте кнопку цикла глубокой очистки в течение пяти секунд.
Нажмите кнопку цикла глубокой очистки на передней панели машины, и ваши инструкции отобразятся на ЖК-экране.
Нажмите на кнопки освобождения кожуха, чтобы снять кожух. Внутренняя дверь откроется пружиной. Отложите кожухи в сторону во время выполнения цикла глубокой очистки.
Нажмите кнопки освобождения резервуара для воды на боковых сторонах машины.
Выдвиньте резервуар для воды из машины и снимите крышку.
Снимите испаритель с машины, поместите его в резервуар для воды и закройте крышку.
Смена фильтров
ЖК-экран вашей машины предупредит вас, когда вам нужно заменить фильтры.
Если вы подключены к приложению Dyson Link, вы получите уведомление.
Перейдите на сайт dyson.co.uk/support/filters, чтобы купить сменные фильтры.
Выключите и отключите машину.
Нажмите кнопки освобождения кожуха с обеих сторон машины, чтобы освободить кожухи.
Когда кожухи будут сняты, внутренняя дверца, в которой находится испаритель, откроется пружиной.
Закройте внутреннюю дверцу, убедившись, что она плотно закрывается со щелчком.
Нажмите на выступы в верхней и нижней части кожухов, чтобы освободить фильтры.
Выбрасывайте использованные фильтры в мусорное ведро.
Снимите защитную упаковку с новых фильтров.
Вставьте фильтры в кожухи, пока защелки сверху и снизу не встанут на место.
Установите кожухи на основание и сильно надавите, пока они не встанут на место со щелчком.
Подключите машину к электросети и нажмите кнопку режима ожидания на задней панели машины.
важно: Сбросить ваш фильтр
Нажмите и удерживайте кнопку ночного режима на пульте дистанционного управления.
На ЖК-экране вашего устройства начнется обратный отсчет от пяти до экрана по умолчанию.
Уровень фильтра будет сброшен, и ваша машина будет готова к использованию.
Непрерывный мониторинг
При включенном непрерывном мониторинге ваш очищающий и увлажняющий вентилятор Dyson будет собирать информацию о качестве воздуха, температуре и влажности, которая отображается на ЖК-экране и в приложении Dyson Link.
По умолчанию непрерывный мониторинг отключен. После включения он всегда будет активен, пока вы не выключите его снова.
Включение / выключение непрерывного мониторинга
Нажмите и удерживайте кнопку режима автоматической очистки на пульте дистанционного управления в течение пяти секунд, чтобы включить его. На ЖК-экране будет отображаться, когда непрерывный мониторинг включен или выключен.
Wi-Fi подключения
По умолчанию Wi-Fi включен. Чтобы включить или выключить Wi-Fi, нажмите и удерживайте кнопку режима ожидания на устройстве в течение пяти секунд.
Уход за вашей машиной
Чтобы ваш вентилятор-увлажнитель Dyson всегда работал с максимальной эффективностью, важно регулярно чистить его и проверять на наличие засоров.
Уборка
Если пыль скапливается на поверхности машины, вытрите пыль с ampподъемную петлю, кожухи и другие детали чистой сухой тканью.
Ищите засоры в отверстиях для впуска воздуха на кожухе и небольшом отверстии внутри кожуха. ampжизненная петля.
Используйте мягкую щетку для удаления пыли и мусора.
Не используйте моющие средства или полироли для чистки машины.
Оповещения
Значок предупреждения может появиться на вашем ЖК-экране, чтобы показать, что ваша машина требует вашего внимания.
Непрерывный предупреждающий треугольник
Выключите и отключите машину.
Подождите 10 секунд, а затем снова подключите машину и включите ее.
Если значок предупреждения продолжает отображаться на ЖК-экране, обратитесь в Dyson.
Временный предупреждающий треугольник
Если предупреждение появляется на ЖК-экране, а затем исчезает, продолжайте использовать машину.
Если на ЖК-экране отображаются какие-либо другие значки предупреждений, обратитесь в Dyson за дальнейшими советами.
Документы / Ресурсы
Перейти к контенту
Русские электронные инструкции по эксплуатации
Постоянно обновляемый большой каталог документации по эксплуатации и использованию современных устройств и оборудования на русском языке. Бесплатное скачивание файлов.
Поиск:
Главная
Просмотр инструкции в pdf
Инструкция по эксплуатации климатического комплекса Dyson Pure Humidify + Cool PH01.
Скачать инструкцию к климатическому комплексу Dyson Pure Humidify + Cool PH01 (23,86 МБ)
Инструкции климатических комплексов Dyson
« Инструкция к кухонной машине Kitfort КТ-1366-2, 4 в 1
» Инструкция к климатическому комплексу Steba LE 100
Вам также может быть интересно
Инструкция к пылесосу Dyson V11 Complete
Инструкция к пылесосу Dyson V7 Parquet Extra
Инструкция к пылесосу Dyson V8 Absolute
Инструкция к пылесосу Dyson V6 Motorhead (ErP)
Инструкция к пылесосу Dyson DC37 Allergy Musclehead
Инструкция к пылесосу Dyson Cinetic Big Ball Animal Pro 2
Инструкция к пылесосу Dyson DC26 Allergy
Инструкция к пылесосу Dyson V7 Motorhead Extra
Добавить комментарий