Kyocera 6535 ошибка 7002

  • Code: 0030
  • Description: FAX PWB system error The FAX process can not be continued due to the malfunction of the FAXPWB. *Only 4in1 models detect
  • Remedy: FAX PWB 1. Unplug the power cord from the wall outlet, and reinstall the FAX controller PWB, and then plug the power cord and turn power on. 2. Reinstall the FAX firmware. 3. Replace the FAX PWB.
  • Code: 0070
  • Description: FAX PWB incompatible detection error In the initial communication with the FAX control PWB, any normal communication command is not transmitted. *Only 4in1 models detect
  • Remedy: FAX PWB 1. Install the FAX system designed for the model. 2. Reinstall the FAX firmware.
  • Code: 0100
  • Description: Backup memory device error Outputs an abnormal status from the flash memory.
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the connectors on the Main/ Engine PWB are properly connected, and if not, re-connect them. 3. Replace the Main/Engine PWB.
  • Code: 0120
  • Description: MAC address data error In case MAC address is invalid data
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check the MAC address on the network status page. 3. Replace the Main/Engine PWB.
  • Code: 0130
  • Description: Backup memory read/write error (Main/Engine PWB) Read/write to the NAND memory can not be executed.
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the connectors on the Main/ Engine PWB are properly connected, and if not, re-connect them. 3. Replace the Main/Engine PWB.
  • Code: 0140
  • Description: Backup memory data error (Main/Engine PWB) At power up, the data that was read from the NAND memory has been determined to be a error.
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Execute U021 initialize memory. 3. Replace the Main/Engine PWB.
  • Code: 0150
  • Description: EEPROM read/write error (Main/Engine PWB) 1. No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. 2. Mismatch of reading data from two locations occurs 8 times successively. 3. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the EEPROM is peroperly installed on the Main/Engine PWB and if not, reinstall it. 3. Replace the Main/Engine PWB. 4. Check the EEPROM and if it is damaged, contact the service support.
  • Code: 0160
  • Description: EEPROM data error (Main/ Engine PWB) Reading data from EEPROM is detected abnormal.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Execute U021 initialize memory. 3. If the EEPROM data are currupted, contact the service support.
  • Code: 0170
  • Description: Billing counting error Mismatch between the value of the Main/Engine PWB and EEPROM, in one of the value of billing counter, life counter, or scanner counter.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Check that the EEPROM installed in the Main/Engine PWB is correct and, if not, install the correct EEPROM for the model. 2. Replace the Main/Engine PWB. 3. If the EEPROM data are currupted, contact the service support.
  • Code: 0180
  • Description: Machine number mismatch When the power is turned on, the machine number does not match the one stored in the Main/Engine PWB.
  • Remedy: EEPROM (Main/ Engine PWB) 1. Check that the EEPROM installed in the Main/Engine PWB is correct and, if not, install the correct EEPROM for the model. 2. Confirm the serial number data for the Main/Engine PWB by using U004. If the mutually different machine number data between «Machine No. (Main)» and «Machine No. (Eng)» is displayed, or if there is a difference between the actual machine number and the number of «Machine No. (Eng)», install the correct EEPROM, and then execute U004.
  • Code: 0190
  • Description: Backup memory device error (Main/Engine PWB) At power up, read/write data from FRAM can not be performed. (retry: 3times)
  • Remedy: FRAM (Main/ Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the connectors on the Main/ Engine PWB are properly connected, and if not, re-connect them. 3. Replace the Main/Engine PWB.
  • Code: 0360
  • Description: Communication error between the engine ASIC During the readback data checked after data transmission, the checksum error or the video signal is not inverted. (failed 10 consecutive times)
  • Remedy: Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 0640
  • Description: Hard disk (SSD) error During the file access after Ready, the I/O error of SSD is detected. (SSD format error after rebooting. For example, System initialization, Sanitization, Encrypted format when installing security kit.)
  • Remedy: SSD (optional HD- 6/7) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Unplug the power cord from the wall outlet, and reinstall the HD-6/7 (SSD). 3. Check that the connection between KUIO connector on the Main/Engine PWB and HD-6/7 (SSD) is proper, and if not, re-connect them. 4. Initialize the HD-6/7 (SSD). 5. Replace the Main/Engine PWB.
  • Code: 0800
  • Description: Image formation problems The printing sequence JAM (J010X) is detected for 2 consecutive times.
  • Remedy: Main/Engine PWB 1. Check if the problem is a printing operation error detection in a particular file, and if it is possible to obtain the reproduction of phenomena by the identification of the job that detected the error, take the job log. 2. If the problem occurs in unspecified job, check the connectors on the Main/ Engine PWB, and reattach it. 3. Replace the Main/Engine PWB.
  • Code: 0830
  • Description: FAX PWB flash program area checksum error The program stored in the flash memory on the FAX control PWB is broken and can not be executed. *Only 4in1 models dete
  • Remedy: FAX firmware 1. Reinstall the FAX firmware.
    FAX PWB 1. Unplug the power cord from the wall outlet, and reinstall the FAX controller PWB, and then plug the power cord and turn power on. 2. Check that the connection between KUIO connector on the Main/Engine PWB and Fax PWB is proper, and if not, re-connect them. 3. Execute [Initializing] by U600. 4. Replace the FAX PWB.
  • Code: 0840
  • Description: Faults of RTC Check at power up. The RTC setting has reverted to a previous state. The machine has not been powered for 5 years (compared to the settings stored periodically in the EEPROM). The RTC setting is older than 00:01 on January 1, 2000. Checked periodically (at every 5 minutes) after power-up. The RTC setting has reverted to a state older than the last time it was checked. 10 minutes have been passed since the previous check.
  • Remedy: Settings of RTC 1. Execute Date Setting using the system menu.
    Backup battery (Main/Engine PWB) 1. Check if the backup battery on the Main/ Engine PWB is not short-circuited. 2. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. If the same service call error is displayed, replace the backup battery
    Main/Engine PWB 1. If the communication error (due to a noise, etc.) is present with the RTC on the Main/Engine PWB, check that the PWB is properly grounded or secured by screws. 2. Replace the Main/Engine PWB.
  • Code: 0870
  • Description: FAX PWB to Main/Engine PWB image data transfer error High-capacity data transfer between the FAX PWB and the Main/Engine PWB was not normally performed even if the data transfer was retried the specified times. *Only 4in1 models detect
  • Remedy: FAX PWB 1. Unplug the power cord from the wall outlet, and reinstall the FAX controller PWB, and then plug the power cord and turn power on. 2. Check that the connection between KUIO connector on the Main/Engine PWB and Fax PWB is proper, and if not, re-connect them. 3. Replace the FAX PWB.
    Main/Engine PWB 1. Replace the Main/Engine PWB.
  • Code: 0920
  • Description: Fax file system error The backup data is not retained for file system abnormality of the flash memory of the FAX PWB. *Only 4in1 models detect
  • Remedy: FAX PWB 1. Execute [Initializing] by U600. 2. Reinstall the FAX firmware. 3. Unplug the power cord from the wall outlet, and reinstall the FAX controller PWB, and then plug the power cord and turn power on. 4. Check that the connection between KUIO connector on the Main/Engine PWB and Fax PWB is proper, and if not, re-connect them. 5. Replace the FAX PWB.
  • Code: 1010
  • Description: Lift motor error (main unit) The following states have been detected 5 times in succession. The lift motor overcurrent is detected for 80 ms. After the cassette is installed, the upper limit detection sensor does not turn ON within 10 s. During printing, after the upper limit detection sensor detects off, and 1 s after ascending control, and the upper limit detection sensor does not detect on. The upper limit detection sensor does not turn off within 5 s after descending control.
  • Remedy: Bottom plate 1. Check to see if the bottom plate can move smoothly and repair or replace it if any problem is found.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. If a wire is pinched by other component, or has defect conduction, replace it. Lift motor and Engine relay PWB (YC25) Engine relay PWB (YC1) and Main/Engine PWB (YC4) Llift sensor and Engine relay PWB
    Drive transmission system for the lift motor 1. Check if the gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check broken gears and replace if any.
    Lift motor Replace the lift motor.
    Lift sensor (upper limit detection sensor) 1. Check if the actuator of the lift sensor can be turned ON/OFF to suit the rise of the cassette bottom plate. 2. Replace the lift sensor
    Engine relay PWB 1. Replace the engine relay PWB.
    Main/Engine PWB 1. Replace the Main/Engine PWB.
  • Code: 1020
  • Description: PF lift motor error (PF1) The following states have been detected 5 times in succession. The lift motor overcurrent is detected for 200 ms. After the cassette is installed, the upper limit detection sensor does not turn ON within 10 s. During printing, after the upper limit detection sensor detects off, and 1 s after ascending control, and the upper limit detection sensor does not detect on. The upper limit detection sensor does not turn off within 5 s after descending control.
  • Remedy: Bottom plate Check to see if the bottom plate can move smoothly and repair or replace it if any problem is found.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. If a wire is pinched by other component, or has defect conduction, replace it. PF lift motor and PF main PWB (YC7) Llift sensor and PF main PWB (YC7) PF main PWB and Engine relay PWB (YC19)
    Drive transmission system for the lift motor 1. Check if the gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check broken gears and replace if any.
    PF lift motor Replace the PF lift motor 1.
    PF lift sensor (upper limit detection sensor) 1. Check if the actuator of the PF lift sensor can be turned ON/OFF to suit the rise of the cassette bottom plate. 2. Replace the PF lift sensor.
    PF main PWB Replace the PF main PWB.
    Engine relay PWB Replace the engine relay PWB.
  • Code: 1030
  • Description: PF lift motor error (PF2) The following states have been detected 5 times in succession. The lift motor overcurrent is detected for 200 ms. After the cassette is installed, the upper limit detection sensor does not turn ON within 10 s. During printing, after the upper limit detection sensor detects off, and 1 s after ascending control, and the upper limit detection sensor does not detect on. The upper limit detection sensor does not turn off within 5 s after descending control.
  • Remedy: Bottom plate Check to see if the bottom plate can move smoothly and repair or replace it if any problem is found.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. If a wire is pinched by other component, or has defect conduction, replace it. PF lift motor and PF main PWB (YC7) Llift sensor and PF main PWB (YC7) PF main PWB and Engine relay PWB (YC19)
    Drive transmission system for the lift motor 1. Check if the gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check broken gears and replace if any.
    PF lift motor Replace the PF lift motor 2.
    PF lift sensor (upper limit detection sensor) 1. Check if the actuator of the PF lift sensor can be turned ON/OFF to suit the rise of the cassette bottom plate. 2. Replace the PF lift sensor.
    PF main PWB Replace the PF main PWB.
    Engine relay PWB Replace the engine relay PWB.
  • Code: 1040
  • Description: PF lift motor error (PF3) The following states have been detected 5 times in succession. The lift motor overcurrent is detected for 200 ms. After the cassette is installed, the upper limit detection sensor does not turn ON within 10 s. During printing, after the upper limit detection sensor detects off, and 1 s after ascending control, and the upper limit detection sensor does not detect on. The upper limit detection sensor does not turn off within 5 s after descending control.
  • Remedy: Bottom plate Check to see if the bottom plate can move smoothly and repair or replace it if any problem is found.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. If a wire is pinched by other component, or has defect conduction, replace it. PF lift motor and PF main PWB (YC7) Llift sensor and PF main PWB (YC7) PF main PWB and Engine relay PWB (YC19)
    Drive transmission system for the lift motor 1. Check if the gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check broken gears and replace if any.
    PF lift motor Replace the PF lift motor.
    PF lift sensor (upper limit detection sensor) 1. Check if the actuator of the PF lift sensor can be turned ON/OFF to suit the rise of the cassette bottom plate. 2. Replace the PF lift sensor.
    PF main PWB Replace the PF main PWB.
    Engine relay PWB Replace the engine relay PWB.
  • Code: 1810
  • Description: Paper feeder communication error (first cassette) A communication error from paper feeder is detected 10 times in succession.
  • Remedy: Paper feeder 1 Check the wiring connection status with the main unit, and if necessary, reconnecting it.
    PF1 main PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. PF1 main PWB (YC3 and Engine relay PWB (YC19) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Reinstall the PF firmware. 4. Replace the PF main PWB. (Refer to the service manual for the paper feeder).
    Engine relay PWB 1. Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 1820
  • Description: Paper feeder communication error (second cassette) A communication error from paper feeder is detected 10 times in succession.
  • Remedy: Paper feeder 2 Check the wiring connection status with PF1, and if necessary, reconnect it.
    PF2 main PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. PF1 main PWB (YC3)and PF2 main PWB (YC5,4) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Reinstall the PF firmware. 4. Replace the PF2 main PWB.
    PF1 main PWB Replace the PF1 main PWB.
  • Code: 1830
  • Description: Paper feeder communication error (third cassette) A communication error from paper feeder is detected 10 times in succession.
  • Remedy: Paper feeder 3 Check the wiring connection status with PF2, and if necessary, reconnect it.
    PF3 main PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. PF2 main PWB (YC3 and PF3 main PWB (YC5,4) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Reinstall the PF firmware. 4. Replace the PF3 main PWB.
    PF2 main PWB Replace the PF2 main PWB.
  • Code: 1900
  • Description: Paper feeder 1 EEPROM error (first cassette) When writing the data, read and write data does not match 4 times in succession.
  • Remedy: PF1 main PWB (EEPROM) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the wiring connector to the main unit is firmly connected, and if necessary, connect the connector all the way in. 3. Replace the PF1 main PWB.
  • Code: 1910
  • Description: Paper feeder 2 EEPROM error (second cassette) When writing the data, read and write data does not match 4 times in succession.
  • Remedy: PF2 main PWB (EEPROM) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the wiring connector with the PF1 is firmly connected, and if necessary, connect the connector all the way in. 3. Replace the PF2 main PWB.
  • Code: 1920
  • Description: Paper feeder 3 EEPROM error (third cassette) When writing the data, read and write data does not match 4 times in succession.
  • Remedy: PF3 main PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the wiring connector with the PF2 is firmly connected, and if necessary, connect the connector all the way in. 3. Replace the PF3 main PWB.
  • Code: 2101
  • Description: Developer motor steadystate error (C,M,Y) After motor is stabilized, the stable signal is turned OFF for continuous 2 s.
  • Remedy: Developer unit 1. Check that the developer roller can be rotated by hand, and if it is locked, replace the developer unit.
    Developer motor 1. Check if the couplings and gears rotate smoothly, and if necessary replace them. 2. Reinsert the connector. 3. Check continuity within the connector wire. If none, replace the wire. Developer motor and Engine relay PWB (YC12) Engine relay PWB (YC1) and Main/ Engine PWB (YC4) 4. Replace the developer motor
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 2111
  • Description: Developer motor startup error (C,M,Y) After the motor starting, the stable signal is not turned ON within 3 s.
  • Remedy: Developer unit 1. Check that the developer roller can be rotated by hand, and if it is locked, replace the developer unit.
    Developer motor 1. Check if the couplings and gears rotate smoothly, and if necessary replace them. 2. Reinsert the connector. 3. Check continuity within the connector wire. If none, replace the wire. Developer motor and Engine relay PWB (YC12) Engine relay PWB (YC1) and Main/ Engine PWB (YC4) 4. Replace the developer motor
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 2201
  • Description: Drum motor CY steadystate error After motor is stabilized, the stable signal is turned OFF for continuous 2 s.
  • Remedy: Drum unit C or Drum unit Y Check that the drum can be rotated by hand, and if it is locked, replace the drum unit C or drum unit Y.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Drum motor CY and Engine relay PWB (YC13) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the drum motor CY 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Drum motor CY Replace the drum motor CY.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 2202
  • Description: Drum motor KM steadystate error After motor is stabilized, the stable signal is turned OFF for continuous 2 s.
  • Remedy: Drum unit K or Drum unit M Check that the drum can be rotated by hand, and if it is locked, replace the drum unit K or drum unit M.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Drum motor KM and Engine relay PWB (YC13) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the drum motor KM 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Drum motor KM Replace the drum motor KM.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 2211
  • Description: Drum motor CY startup error After the motor starting, the stable signal is not turned ON within 3 s.
  • Remedy: Drum unit C or Drum unit Y Check that the drum can be rotated by hand, and if it is locked, replace the drum unit C or drum unit Y.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Drum motor CY and Engine relay PWB (YC13) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the drum motor CY 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Drum motor CY Replace the drum motor CY.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 2212
  • Description: Drum motor KM startup error After the motor starting, the stable signal is not turned ON within 3 s.
  • Remedy: Drum unit K or Drum unit M Check that the drum can be rotated by hand, and if it is locked, replace the drum unit K or drum unit M.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Drum motor KM and Engine relay PWB (YC13) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the drum motor KM 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Drum motor KM Replace the drum motor KM.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 2500
  • Description: Paper feed motor error After the motor starting, the stable signal is not turned ON within 3 s. After motor is stabilized, the stable signal is turned OFF for continuous 2 s.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Paper feed motor and Engine relay PWB (YC15) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the paper feed motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Replace the gears, if damaged.
    Paper feed motor Replace the paper feed motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 2600
  • Description: PF drive motor 1 error (PF1) During the motor drive, the stable signal is not turned on for continuous 5 s.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. PF drive motor 1 and PF main PWB (YC6)
    Drive transmission system for the PF drive motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Replace the gears, if damaged.
    PF drive motor Replace the PF drive motor 1.
    PF main PWB Replace the PF main PWB.
  • Code: 2610
  • Description: PF drive motor 2 error (PF2) During the motor drive, the stable signal is not turned on for continuous 5 s.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. PF drive motor 2 and PF main PWB (YC6)
    Drive transmission system for the PF drive motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Replace the gears, if damaged.
    PF drive motor Replace the PF drive motor 2.
    PF main PWB Replace the PF main PWB.
  • Code: 2620
  • Description: PF drive motor 3 error (PF3) During the motor drive, the stable signal is not turned on for continuous 5 s.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. PF drive motor 3 and PF main PWB (YC6)
    Drive transmission system for the PF drive motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Replace the gears, if damaged.
    PF drive motor Replace the PF drive motor 3.
    PF main PWB Replace the PF main PWB.
  • Code: 2760
  • Description: Primary transfer belt motor startup error After the motor starting, the stable signal is not turned ON within 3 s.
  • Remedy: Primary transfer unit 1. Check that the belt can be rotated by hand, and if it is locked, get rid of the factor. 2. Replace the primary transfer unit.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Transfer belt motor and Engine relay PWB (YC14) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the primary transfer belt motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Replace the gears, if damaged.
    Primary transfer belt motor Replace the primary transfer belt motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 2820
  • Description: Primary transfer belt motor steady-state error After motor is stabilized, the stable signal is turned OFF for continuous 2 s.
  • Remedy: Primary transfer unit 1. Check that the belt can be rotated by hand, and if it is locked, check if foreign objects such as jammed paper, and if jammed, get rid of it. 2. Replace the primary transfer unit.
    Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Transfer belt motor and Engine relay PWB (YC14) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Drive transmission system for the primary transfer belt motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Replace the gears, if damaged.
    Primary transfer belt motor Replace the primary transfer belt motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 3100
  • Description: Scanner carriage error When turning the power on, or when the reading of the original document by table or DP scanning has completed, the home position sensor is not turned off, even if the home position sensor is on and the scanner carriage moves to the scanning direction. Or, the home position sensor does not turn on, even if the home position sensor is in off and the scanner carriage move to the return direction.
  • Remedy: Image scanner motor 1. Move the scanner by hand to check whether it smoothly moves, and if necessary, remedy it. 2. Check that the scanner drive belt is not disengaged, and if necessary, remedy it. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Image scanner motor and Main/Engine PWB (YC17) 4. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 5. Replace the image scanner motor.
    Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Home position sensor and CCD PWB (YC3) CCD PWB (YC1) and Main/Engine PWB (YC2014) 3. Replace the home position sensor.
    CCD PWB Replace the scanner carriage and execute the U411.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 3200
  • Description: LED lamp error The white standard data obtained when the lamp is turned on at the time of an initialization is lower than the rated value.
  • Remedy: LED PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LED PWB and CCD PWB (YC2) CCD PWB (YC1) and Main/Engine PWB (YC2014)
    Mirror Replace the image scanner unit and execute U411, if the mirror is dropped off by drop shock.
    CCD PWB Replace the scanner carriage and execute the U411.
    Main/Engine PWB Replace the Main/Engine PWB.
  • Code: 3500
  • Description: Communication error between scanner ASIC (MFP model only) A communication error is detected. (Read back values are different.)
  • Remedy: CCD PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CCD PWB (YC1) and Main/Engine PWB (YC2014) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the scanner carriage and execute the U411.
    Main/Engine PWB 1. Upgrade the scanner firmware to the latest version. 2. Replace the Main/Engine PWB.
  • Code: 4001
  • Description: Polygon motor (Black, Magenta) startup error After the polygon motor starting, the motor stable signal is not turned ON after 6 s.
  • Remedy: Polygon motor (Black, Magenta) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2016) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4002
  • Description: Polygon motor (Cyan, Yellow) startup error After the polygon motor starting, the motor stable signal is not turned ON after 6 s.
  • Remedy: Polygon motor (Cyan, Yellow) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2017) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4011
  • Description: Polygon motor (Black, Magenta) steady error After the polygon motor stabilization, the motor stable signal is turned OFF for consecutive 6 s.
  • Remedy: Polygon motor (Black, Magenta) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2016) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4012
  • Description: Polygon motor (Cyan, Yellow) steady error After the polygon motor stabilization, the motor stable signal is turned OFF for consecutive 6 s.
  • Remedy: Polygon motor (Cyan, Yellow) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2017) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4101
  • Description: Laser BD (Black) error The laser can not be received for 1 s, after the Black laser emission starts.
  • Remedy: LSU (Black,Magenta) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2016) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4102
  • Description: Laser BD (Cyan) error The laser can not be received for 1 s, after the Cyan laser emission starts.
  • Remedy: LSU (Cyan, Yellow) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2017) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4103
  • Description: Laser BD (Magenta) error The laser can not be received for 1 s, after the Magenta laser emission starts.
  • Remedy: LSU (Black,Magenta) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2016) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4104
  • Description: Laser BD (Yellow) error The laser can not be received for 1 s, after the Yellow laser emission starts.
  • Remedy: LSU (Cyan, Yellow) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2017) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4201
  • Description: Laser BD (Black) steadystate error During the polygon motor steady rotation, the BD signal of Black is not detected.
  • Remedy: LSU (Black,Magenta) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2016) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4202
  • Description: Laser BD (Cyan) steadystate error During the polygon motor steady rotation, the BD signal of Cyan is not detected.
  • Remedy: LSU (Cyan,Yellow) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2017) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4203
  • Description: Laser BD (Magenta) steadystate error During the polygon motor steady rotation, the BD signal of Magenta is not detected.
  • Remedy: LSU (Black,Magenta) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2016) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4204
  • Description: Laser BD (Yellow) steadystate error During the polygon motor steady rotation, the BD signal of Yellow is not detected.
  • Remedy: LSU (Cyan,Yellow) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU and Main/Engine PBW (YC2017) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check both main and engine firmware, and upgrade to the latest version, if necessary. 2. Replace the Main/Engine PWB.
  • Code: 4600
  • Description: LSU cleaning motor error During driving the LSU cleaning motor, an over-current is detected for 5 s successively
  • Remedy: LSU cleaning spiral 1. Execute [LSU cleaning] using [Adjustment/ Maintenance] of the system menu. 2. Check that the drive gear and cleaning spiral can rotate and they are not unusually loaded, and if necessary, clean and grease.
    LSU cleaning motor 1. Confirm that the LSU cleaning motor has been firmly attached. 2. Replace the LSU cleaning motor.
    Engine relay PWB 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by other component, or has defect conduction, replace it. LSU cleaning motor and Engine relay PWB (YC26) 3. Replace the engine relay PWB.
  • Code: 4700
  • Description: VIDEO_ASIC device error Communication with the video ASIC has failed 5 times successively. After writing to VIDEO ASIC, the error that the reading value from same address does not match occurs 8 times successively.
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check that the connectors on the Main/ Engine PWB are properly connected, and if not, re-connect them. 3. Replace the Main/Engine PWB.
  • Code: 6000
  • Description: Broken fuser main heater wire During the warming up, the temperature detected by the center thermistor does not reach 100 °C/212.0 °F for 20 s. During the warming up, the temperature detected by the center thermistor does not reach the stable display temperature for 30 s successively, after it reach to 100 °C/212.0 °F.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit.
    Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. Replace the power source PWB.
    Eject PWB Replace the eject PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6020
  • Description: Abnormally high fuser center thermistor temperature The center thermistor detected the temperature exceeds 240 °C/464.0 °F. for 1 s successively.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Check if the fuser roller has foreign objects such as the toner contamination. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 4. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 5. Replace the fuser unit.
    Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. If the fuser heater is turned on at all times, replace the power source PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Check if the Main/Engine PWB is properly secured with screws. 3. Replace the Main/Engine PWB.
  • Code: 6030
  • Description: Broken fuser center thermistor wire During the edge thermistor detects more than 30 °C/86.0 °F, the center thermistor detects low temperature for 1.6 s.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. Replace the fuser unit.
    Eject PWB Replace the eject PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6040
  • Description: Fuser heater error (35 ppm models) Input value from the fuser center thermistor is abnormal for 1 s successively.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. Replace the fuser unit.
    Eject Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.PWB Replace the eject PWB.
  • Code: 6050
  • Description: Abnormally low fuser center thermistor temperature During the warming up and the printing, the center thermistor has detected less than 100 °C/212.0 °F. for 1 s successively.
  • Remedy: Reduction of the power supply voltage 1. Check that no voltage drop of more than 10% of the rated is caused during printing. 2. If the power is overloaded, change the AC outlet that supplies power.
    Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit.
    Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. Replace the power source PWB.
    Eject PWB Replace the eject PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6200
  • Description: Fuser heater error (SUb heater: for 35ppm models) During the warming up, even if the main heater (sub heater for 35ppm models) is turned on for 30 s successively, the temperature detected by the edge thermistor does not reach 100 °C/212.0 °F. During the warming up, the temperature detected by the edge thermistor does not reach the stable display temperature, even if the main heater (sub heater for 35ppm models) is turned on for 30 s successively, after the temperature detected by the edge thermistor has reached to 100 °C/212.0 °F.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. If the fuser sub-heater is not turned on (broken thermostat wire), replace the fuser unit.
    Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. Replace the power source PWB.
    Eject PWB Replace the eject PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6220
  • Description: Abnormally high fuser heater temperature The temperature detected by the edge thermistor exceeds 240 °C/464.0 °F for 1 s successively.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Check if the fuser roller has foreign objects such as the toner contamination. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 4. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 5. Replace the fuser unit.
    Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. If the fuser heater is turned on at all times, replace the power source PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Check if the Main/Engine PWB is properly secured with screws. 3. Replace the Main/Engine PWB.
  • Code: 6230
  • Description: Broken fuser edge thermistor wire Fuser edge thermistor detects low temperature for 1.6 s.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. Replace the fuser unit.
    Eject PWB Replace the eject PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6250
  • Description: Abnormally low fuser edge thermistor temperature During the warming up and the printing, the edge thermistor has detected less than 100 °C/212.0 °F for 1 s successively.
  • Remedy: Reduction of the power supply voltage 1. Check that no voltage drop of more than 10% of the rated is caused during printing. 2. If the power is overloaded, change the AC outlet that supplies power.
    Fuser unit 1. Check there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 3. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit.
    Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. Replace the power source PWB.
    Eject PWB Replace the eject PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6400
  • Description: Zero-cross signal error During the fuser heater on, and no detection the disconnection 24V, the zero-cross signal is not input for 1 s successively.
  • Remedy: Power source PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Power source PWB (YC105) and Main/ Engine PWB (YC20) 2. Replace the power source PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6610
  • Description: The fuser pressure release error The fuser release sensor does not turn on or off, after 30 s from starting pressurization or depressurization operation.
  • Remedy: Fuser unit 1. Check there is no paper jam. 2. Check if the fuser pressure can be reduced by inverse rotation of the fuser gear by hand. 3. Check if the envelope sensor light is blocked out by the actuator during depressurization operation. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit (Envelope sensor) and Eject PWB (YC2) Eject PWB (YC1) and Main/Engine PWB (YC11) 5. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 6. Replace the fuser unit.
    Fuser motor 1. Check if the fuser motor is rotating. 2. When turning the power on, check if the fuser motor rotates reversely. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser motor and Engine relay PWB (YC20) 4. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 5. Replace the fuser motor.
    Eject PWB Replace the eject PWB.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 6910
  • Description: Engine firmware unexpected error The drum motor drive continued more than 60 minutes except during printing. (engine lock) The charge bias is turned off, during the developer bias is on. If the writing operation to the EEPROM is locked for 30 sec. Fuser temperature is abnormal, for more than a predetermined time.
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check if the Main/Engine PWB is properly secured with screws. (Grounding check) 3. Check that the connectors on the Main/ Engine PWB are properly connected, and if not, re-connect them. 4. Check the engine firmware and upgrade to the latest version if necessary. 5. Replace the Main/Engine PWB.
  • Code: 7001
  • Description: Toner motor K error During driving the toner motor, an over-current detection signal is detected for 40 ms successively. When detected during warming up The message of «Shake the toner container (K)» is displayed. (exited by the opening and closing of the inner tray) Repeat the operation above, for three times. Four times or more, if an over-current detection signal is detected for 5 s successively, a service call error message appears.
  • Remedy: Toner container Black 1. Check that the spiral of the toner container can be rotated by hand 2. Replace the toner container.
    Drive transmission system for the toner motor 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by other component, or has defect conduction, replace it. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Toner motor 1. Check how the toner motor is attached. 2. Replace the toner motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7002
  • Description: Toner motor C error During driving the toner motor, an over-current detection signal is detected for 40 ms successively. When detected during warming up The message of «Shake the toner container (C)» is displayed. (exited by the opening and closing of the inner tray) Repeat the operation above, for three times. Four times or more, if an over-current detection signal is detected for 5 s successively, a service call error message appears.
  • Remedy: Toner container Cyan 1. Check that the spiral of the toner container can be rotated by hand 2. Replace the toner container.
    Drive transmission system for the toner motor 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by other component, or has defect conduction, replace it. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Toner motor 1. Check how the toner motor is attached. 2. Replace the toner motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7003
  • Description: Toner motor M error During driving the toner motor, an over-current detection signal is detected for 40 ms successively. When detected during warming up The message of «Shake the toner container (M)» is displayed. (exited by the opening and closing of the inner tray) Repeat the operation above, for three times. Four times or more, if an over-current detection signal is detected for 5 s successively, a service call error message appears.
  • Remedy: Toner container Magenta 1. Check that the spiral of the toner container can be rotated by hand 2. Replace the toner container.
    Drive transmission system for the toner motor 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by other component, or has defect conduction, replace it. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Toner motor 1. Check how the toner motor is attached. 2. Replace the toner motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7004
  • Description: Toner motor Y error During driving the toner motor, an over-current detection signal is detected for 40 ms successively. When detected during warming up The message of «Shake the toner container (Y)» is displayed. (exited by the opening and closing of the inner tray) Repeat the operation above, for three times. Four times or more, if an over-current detection signal is detected for 5 s successively, a service call error message appears.
  • Remedy: Toner container Yellow 1. Check that the spiral of the toner container can be rotated by hand 2. Replace the toner container.
    Drive transmission system for the toner motor 1. Check if the gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check broken couplings and gears, and replace if any.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by other component, or has defect conduction, replace it. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4)
    Toner motor 1. Check how the toner motor is attached. 2. Replace the toner motor.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7101
  • Description: Toner sensor K error For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container Black 1. Check that the toner container has been properly installed, and if necessary, reinstall. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Primary transfer unit 1. Check whether the toner supply inlet at the upper side of the unit opens by attaching the toner container. 2. Check whether the toner supply inlet at the lower side of the unit is open by the lever operation. 3. Check if toner is clogged in the toner supplying pass in the cleaning section. 4. Replace the primary transfer unit.
    Developer unit (toner sensor) 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Developer unit (toner sensor) and Drum relay PWB (YC6) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner motor 1. Check that the toner motor is properly attached. 2. Check the couplings and gears can rotate or they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the toner motor.
    Drum relay PWB Replace the drum relay PWB.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7102
  • Description: Toner sensor C error For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container Cyan 1. Check that the toner container has been properly installed, and if necessary, reinstall. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Primary transfer unit 1. Check whether the toner supply inlet at the upper side of the unit opens by attaching the toner container. 2. Check whether the toner supply inlet at the lower side of the unit is open by the lever operation. 3. Check if toner is clogged in the toner supplying pass in the cleaning section. 4. Replace the primary transfer unit.
    Developer unit (toner sensor) 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Developer unit (toner sensor) and Drum relay PWB (YC8) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner motor 1. Check that the toner motor is properly attached. 2. Check the couplings and gears can rotate or they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the toner motor.
    Drum relay PWB Replace the drum relay PWB.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7103
  • Description: Toner sensor M error For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container Magenta 1. Check that the toner container has been properly installed, and if necessary, reinstall. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Primary transfer unit 1. Check whether the toner supply inlet at the upper side of the unit opens by attaching the toner container. 2. Check whether the toner supply inlet at the lower side of the unit is open by the lever operation. 3. Check if toner is clogged in the toner supplying pass in the cleaning section. 4. Replace the primary transfer unit.
    Developer unit (toner sensor) 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Developer unit (toner sensor) and Drum relay PWB (YC7) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner motor 1. Check that the toner motor is properly attached. 2. Check the couplings and gears can rotate or they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner motor and Engine relay PWB (YC1) Engine relay PWB (YC1) and Main/Engine PWB (YC4) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the toner motor.
    Drum relay PWB Replace the drum relay PWB.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7104
  • Description: Toner sensor Y error For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container Yellow 3. Check that the toner container has been properly installed, and if necessary, reinstall. 4. Check that the toner supply inlet of the toner container can be opened by the lever operation. 5. Replace the toner container.
    Primary transfer unit 1. Check whether the toner supply inlet at the upper side of the unit opens by attaching the toner container. 2. Check whether the toner supply inlet at the lower side of the unit is open by the lever operation. 3. Check if toner is clogged in the toner supplying pass in the cleaning section. 4. Replace the primary transfer unit.
    Developer unit (toner sensor) 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Developer unit (toner sensor) and Drum relay PWB (YC9) Drum relay PWB (YC1) and Main/Engine PWB (YC4) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner motor 1. Check that the toner motor is properly attached. 2. Check the couplings and gears can rotate or they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner motor and Engine relay PWB (YC18) Engine relay PWB (YC1) and Main/Engine PWB (YC4) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the toner motor.
    Drum relay PWB Replace the drum relay PWB.
    Engine relay PWB Replace the engine relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7200
  • Description: Broken inner thermistor wire (Developer) The sensor input sampling is greater than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Developer unit K 1. Confirm that the connector of developer unit K is firmly connected, and if necessary, push the unit all the way in. Developer unit K (toner sensor) and Drum relay PWB (YC6) Drum relay PWB (YC1) and Main/Engine PWB (YC4) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Replace the developer unit K.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7201
  • Description: Short-circuited inner thermistor (Developer) The sensor input sampling is less than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Developer unit K 1. Confirm that the connector of developer unit K is firmly connected, and if necessary, push the unit all the way in. Developer unit K (toner sensor) and Drum relay PWB (YC6) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Replace the developer unit K.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7221
  • Description: Broken inner thermistor wire (LSU Magenta & Black) The sensor input sampling is greater than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: LSU (Magenta & Black) 1. Confirm that the wiring connector of LSU (Magenta & Black) is firmly connected, and if necessary, connect the connector all the way in. LSU (Magenta & Black) and Main/ Engine PWB (YC2016) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Replace the LSU (Magenta & Black).
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7222
  • Description: Broken inner thermistor wire (LSU Cyan & Yellow) The sensor input sampling is greater than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: LSU (Cyan & Yellow) 1. Confirm that the wiring connector of LSU (Cyan & Yellow) is firmly connected, and if necessary, connect the connector all the way in. LSU (Cyan & Yellow) and Main/Engine PWB (YC2017) 2. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 3. Replace the LSU (Cyan & Yellow).
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7401
  • Description: Developer unit K type mismatch error (Black) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit K Check if the developer unit of different models is mounted, and replace it to the correct one.
  • Code: 7402
  • Description: Developer unit C type mismatch error (Cyan) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit C Check if the developer unit of different models is mounted, and replace it to the correct one.
  • Code: 7403
  • Description: Developer unit M type mismatch error (Magenta) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit M Check if the developer unit of different models is mounted, and replace it to the correct one.
  • Code: 7404
  • Description: Developer unit Y type mismatch error (Yellow) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit Y Check if the developer unit of different models is mounted, and replace it to the correct one.
  • Code: 7411
  • Description: Drum unit K type mismatch error (Black) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit K Check if the drum unit of different models is attached, and replace it to the correct one.
  • Code: 7412
  • Description: Drum unit C type mismatch error (Cyan) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit C Check if the drum unit of different models is attached, and replace it to the correct one.
  • Code: 7413
  • Description: Drum unit M type mismatch error (Magenta) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit M Check if the drum unit of different models is attached, and replace it to the correct one.
  • Code: 7414
  • Description: Drum unit Y type mismatch error (Yellow) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit Y Check if the drum unit of different models is attached, and replace it to the correct one.
  • Code: 7601
  • Description: ID sensor L error (Left side) When the measured value of the ID sensor matches any of the following. If the light potential P-wave is lower than the dark potential P-wave (+0.5V). If light potential S-wave is lower than the dark potential S-wave. The dark potential P/S-wave is greater than 0.8V, or less than 0.15V.
  • Remedy: ID sensor L (Left side) 1. Clean the ID sensor surface. 2. Check how the ID sensor is attached. 3. Check if the error is detected after performing the calibration. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. ID sensor and Main/Engine PWB (YC13) 5. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 6. Replace the ID sensor.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. Replace the Main/Engine PWB.
  • Code: 7602
  • Description: ID sensor R error (Right side) When the measured value of the ID sensor matches any of the following. If the light potential P-wave is lower than the dark potential P-wave (+0.5V). If light potential S-wave is lower than the dark potential S-wave. The dark potential P/S-wave is greater than 0.8V, or less than 0.15V.
  • Remedy: ID sensor R (Right side) 1. Clean the ID sensor surface. 2. Check how the ID sensor is attached. 3. Check if the error is detected after performing the calibration. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. ID sensor and Main/Engine PWB (YC14) 5. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 6. Replace the ID sensor.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7611
  • Description: ID sensor density error (K) During the calibration, ID sensor cannot read a patch density on the primary transfer belt normally. (Black)
  • Remedy: Primary transfer unit ID sensor Drum unit Developer unit LSU Main/Engine PWB 1. After turning OFF the power switch, disconnect the power plug and connect it again, then turning ON the power switch. 2. By adjustment / maintenance of the system menu, execute the color calibration. 3. Check the occurrence of this C call in the Event Log. 4. When the same C call is detected again, Clean if there are any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether the shutter of ID sensor is opened during closing the paper tray. 6. There is no improvement, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether any failure in the drum unit, developer unit, LSU. 8. There is no improvement, replace the main / engine PWB.
  • Code: 7612
  • Description: ID sensor density error (C) During the calibration, ID sensor cannot read a patch density on the primary transfer belt normally. (Cyan)
  • Remedy: Primary transfer unit ID sensor Drum unit Developer unit LSU Main/Engine PWB 1. After turning OFF the power switch, disconnect the power plug and connect it again, then turning ON the power switch. 2. By adjustment / maintenance of the system menu, execute the color calibration. 3. Check the occurrence of this C call in the Event Log. 4. When the same C call is detected again, Clean if there are any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether the shutter of ID sensor is opened during closing the paper tray. 6. There is no improvement, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether any failure in the drum unit, developer unit, LSU. 8. There is no improvement, replace the main / engine PWB.
  • Code: 7613
  • Description: ID sensor density error (M) During the calibration, ID sensor cannot read a patch density on the primary transfer belt normally. (Magenta)
  • Remedy: Primary transfer unit ID sensor Drum unit Developer unit LSU Main/Engine PWB 1. After turning OFF the power switch, disconnect the power plug and connect it again, then turning ON the power switch. 2. By adjustment / maintenance of the system menu, execute the color calibration. 3. Check the occurrence of this C call in the Event Log. 4. When the same C call is detected again, Clean if there are any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether the shutter of ID sensor is opened during closing the paper tray. 6. There is no improvement, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether any failure in the drum unit, developer unit, LSU. 8. There is no improvement, replace the main / engine PWB.
  • Code: 7614
  • Description: ID sensor density error (Y) During the calibration, ID sensor cannot read a patch density on the primary transfer belt normally. (Yellow)
  • Remedy: Primary transfer unit ID sensor Drum unit Developer unit LSU Main/Engine PWB 1. After turning OFF the power switch, disconnect the power plug and connect it again, then turning ON the power switch. 2. By adjustment / maintenance of the system menu, execute the color calibration. 3. Check the occurrence of this C call in the Event Log. 4. When the same C call is detected again, Clean if there are any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether the shutter of ID sensor is opened during closing the paper tray. 6. There is no improvement, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether any failure in the drum unit, developer unit, LSU. 8. There is no improvement, replace the main / engine PWB.
  • Code: 7620
  • Description: ID sensor timing error The ID sensor does not properly read the patch printing position on the primary transfer belt or there is poor density. *: Automatic color registration correction does not succeed
  • Remedy: Primary transfer unit ID sensor Drum unit Developer unit LSU Main/Engine PWB 1. After turning OFF the power switch, disconnect the power plug and connect it again, then turning ON the power switch. 2. By adjustment / maintenance of the system menu, execute the color calibration. 3. Check the occurrence of this C call in the Event Log. 4. When the same C call is detected again, Clean if there are any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether the shutter of ID sensor is opened during closing the paper tray. 6. There is no improvement, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether any failure in the drum unit, developer unit, LSU. 8. When checking the printing position of the color, if there is any color shift occurs, re-install the LSU and the drum unit. 9. There is no improvement, replace the main / engine PWB.
  • Code: 7800
  • Description: Broken outer thermistor wire The sensor input sampling is greater than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Temperature sensor 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Outer temperature sensor and Main/Engine PWB (YC24) 2. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 3. Replace the temperature sensor PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7901
  • Description: Drum unit K EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit K 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit and Drum relay PWB (YC2) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7902
  • Description: Drum unit C EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit C 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit and Drum relay PWB (YC4) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7903
  • Description: Drum unit M EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit M 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit and Drum relay PWB (YC3) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7904
  • Description: Drum unit Y EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit Y 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit and Drum relay PWB (YC5) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7911
  • Description: Developer unit K EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit K 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit and Drum relay PWB (YC6) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7912
  • Description: Developer unit C EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit C 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit and Drum relay PWB (YC8) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7913
  • Description: Developer unit M EEPROM error (1)No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. (2)Mismatch of reading data from two locations occurs 8 times successively. (3)Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit M 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit and Drum relay PWB (YC3) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 7914
  • Description: Developer unit Y EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit Y 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit and Drum relay PWB (YC9) Drum relay PWB (YC1) and Main/Engine PWB (YC15) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Drum relay PWB Replace the drum relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 9180
  • Description: DP switchback motor error When the home position was not detected even if the processing was retried 3 consecutive times. Home position detection: When the home position is not detected by driving one rotation of the DP switchback motor.
  • Remedy: DP switchback motor 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the connector of the switchback motor is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DP switchback motor and DP main PWB (YC2) DP main PWB (YC1) and Main/Engine PWB (YC2) 4. If the wire is disconnected, short-circuited or has ground fault, or the connector pin is deformed, replace the wire. 5. Replace the DP switchback motor.
    DP switchback sensor 1. Rotate the switchback motor by hand to check that it is not unusually difficult to rotate. 2. Check that the DP switchback sensor is not disengaged and is correctly positioned. And check that the actuator correctly blocks the light. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DP switchback sensor and Main/Engine PWB (YC18) 4. If the wiring is disconnected, short-circuited or has ground fault, replace the wire. 5. DP switchback sensor (DPSBS)
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the Main/Engine PWB.
  • Code: 9540
  • Description: Backup data error The machine may not be recovered or may have trouble in its function with changes of the internal data when replacing some the parts at the same time.
  • Remedy: PWBs Reattach the parts below in case of replacing 2 or more of them at the same time. Affected parts : Memory, PWBs * Do not replace two or more of the parts at the same time. * And, do not either execute the following works when replacing the above parts. Replace the drum unit or the developing unit. Replace the drum unit for the one color with another in the same machine.
  • Code: F000
  • Description: Communication error between Main/Engine PWB and Operation panel PWB
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Check the wirings and connectors between the Main/Engine PWB and the operation panel PWB. Operation panel PWB and Main/Engine PWB (YC2002). 3. Replace the Main/Engine PWB.
    Operation panel PWB Replace the operation panel PWB.
  • Code: F010
  • Description: Program read error
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. If not corrected, replace the Main/Engine PWB and check operation.
  • Code: F020
  • Description: Main/Engine PWB RAM checksum error
  • Remedy: Main memory of the Main/Engine PWB (RAM) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. If not corrected, replace the Main/Engine PWB and check operation.
  • Code: F040
  • Description: Communication error between Main/Engine PWB and Print engine
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Repair or replace the wire from the Main/ Engine PWB that may be grounded. (Check short-circuit between 5V and 3.3V.) 3. Check both main and engine firmware, and upgrade to the latest version, if necessary. 4. If not corrected, replace the Main/Engine PWB.
  • Code: F050
  • Description: Print engine main program error
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug the power cord and then turn on the power switch. 2. Confirm that the EEPROM has been properly installed. 3. Check both main and engine firmware, and upgrade to the latest version, if necessary. 4. If not corrected, replace the Main/Engine PWB.

Ошибки Kyocera ECOSYS M2030dn

Ошибки Kyocera ECOSYS M2030pn

Ошибки Kyocera ECOSYS M2035dn

Ошибки Kyocera ECOSYS M2040dn

Ошибки Kyocera ECOSYS M2135dn

Ошибки Kyocera ECOSYS M2530dn

Ошибки Kyocera ECOSYS M2535dn

Ошибки Kyocera ECOSYS M2540dn

Ошибки Kyocera ECOSYS M2540dw

Ошибки Kyocera ECOSYS M2635dn

Ошибки Kyocera ECOSYS M2635dw

Ошибки Kyocera ECOSYS M2640idw

Ошибки Kyocera ECOSYS M3040dn

Ошибки Kyocera ECOSYS M3040idn

Ошибки Kyocera ECOSYS M3145dn

Ошибки Kyocera ECOSYS M3145idn

Ошибки Kyocera ECOSYS M2735dw

Ошибки Kyocera ECOSYS M3540dn

Ошибки Kyocera ECOSYS M3540idn

Ошибки Kyocera ECOSYS M3550idn

Ошибки Kyocera ECOSYS M3560idn

Ошибки Kyocera ECOSYS M3645dn

Ошибки Kyocera ECOSYS M3645idn

Ошибки Kyocera ECOSYS M3655idn

Ошибки Kyocera ECOSYS M3660idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M4125idn

Ошибки Kyocera ECOSYS M4132idn

Ошибки Kyocera ECOSYS M5521cdn

Ошибки Kyocera ECOSYS M5521cdw

Ошибки Kyocera ECOSYS M5526cdn

Ошибки Kyocera ECOSYS M5526cdw

Ошибки Kyocera ECOSYS M6026cdn

Ошибки Kyocera ECOSYS M6026cidn

Ошибки Kyocera ECOSYS M6030cdn

Ошибки Kyocera ECOSYS M6035cidn

Ошибки Kyocera ECOSYS M6230cidn

Ошибки Kyocera ECOSYS M6235cidn

Ошибки Kyocera ECOSYS M6526cdn

Ошибки Kyocera ECOSYS M6526cidn

Ошибки Kyocera ECOSYS M6530cdn

Ошибки Kyocera ECOSYS M6535cidn

Ошибки Kyocera ECOSYS M6630cidn

Ошибки Kyocera ECOSYS M6635cidn

Ошибки Kyocera ECOSYS M8124cidn

Ошибки Kyocera ECOSYS M8130cidn

Ошибки Kyocera ECOSYS P2035d

Ошибки Kyocera ECOSYS P2040dn

Ошибки Kyocera ECOSYS P2040dw

Ошибки Kyocera ECOSYS P2135d

Ошибки Kyocera ECOSYS P2135dn

Ошибки Kyocera ECOSYS P2235dn

Ошибки Kyocera ECOSYS P2235dw

Ошибки Kyocera ECOSYS P3045dn

Ошибки Kyocera ECOSYS P3050dn

Ошибки Kyocera ECOSYS P3055dn

Ошибки Kyocera ECOSYS P3060dn

Ошибки Kyocera ECOSYS P3145dn

Ошибки Kyocera ECOSYS P3150dn

Ошибки Kyocera ECOSYS P3155dn

Ошибки Kyocera ECOSYS P3160dn

Ошибки Kyocera ECOSYS P3260dn

Ошибки Kyocera ECOSYS P4035dn

Ошибки Kyocera ECOSYS P4040dn

Ошибки Kyocera ECOSYS P5021cdn

Ошибки Kyocera ECOSYS P5021cdw

Ошибки Kyocera ECOSYS P5026cdn

Ошибки Kyocera ECOSYS P5026cdw

Ошибки Kyocera ECOSYS P6021cdn

Ошибки Kyocera ECOSYS P6026cdn

Ошибки Kyocera ECOSYS P6030cdn

Ошибки Kyocera ECOSYS P6035cdn

Ошибки Kyocera ECOSYS P6130cdn

Ошибки Kyocera ECOSYS P6230cdn

Ошибки Kyocera ECOSYS P6235cdn

Ошибки Kyocera ECOSYS P7035cdn

Ошибки Kyocera ECOSYS P7040cdn

Ошибки Kyocera ECOSYS P7240cdn

Ошибки Kyocera ECOSYS P8060cdn

Ошибки Kyocera FS-C8600DN

Ошибки Kyocera FS-C8650DN

Ошибки Kyocera FS1016MFP

Ошибки Kyocera FS1018MFP

Ошибки Kyocera FS1020MFP

Ошибки Kyocera FS1024MFP

Ошибки Kyocera FS1025MFP

Ошибки Kyocera FS1028MFP

Ошибки Kyocera FS1030MFP

Ошибки Kyocera FS1035MFP

Ошибки Kyocera FS1040

Ошибки Kyocera FS1050

Ошибки Kyocera FS1060DN

Ошибки Kyocera FS1100

Ошибки Kyocera FS1110

Ошибки Kyocera FS1116MFP

Ошибки Kyocera FS1118MFP

Ошибки Kyocera FS1120

Ошибки Kyocera FS1120MFP

Ошибки Kyocera FS1124MFP

Ошибки Kyocera FS1125MFP

Ошибки Kyocera FS1128MFP

Ошибки Kyocera FS1130MFP

Ошибки Kyocera FS1135MFP

Ошибки Kyocera FS1200

Ошибки Kyocera FS1220MFP

Ошибки Kyocera FS1300D

Ошибки Kyocera FS1320D

Ошибки Kyocera FS1320MFP

Ошибки Kyocera FS1325MFP

Ошибки Kyocera FS1350DN

Ошибки Kyocera FS1370DN

Ошибки Kyocera FS1500

Ошибки Kyocera FS6020

Ошибки Kyocera FS6025MFP

Ошибки Kyocera FS6025MFPB

Ошибки Kyocera FS6030MFP

Ошибки Kyocera FS6500

Ошибки Kyocera FS6525MFP

Ошибки Kyocera FS6530MFP

Ошибки Kyocera FS6700

Ошибки Kyocera FS6900

Ошибки Kyocera FS6950DN

Ошибки Kyocera FS8000CD

Ошибки Kyocera FS8000CN

Ошибки Kyocera FS8100DN

Ошибки Kyocera TASKalfa 180

Ошибки Kyocera TASKalfa 1800

Ошибки Kyocera TASKalfa 1801

Ошибки Kyocera TASKalfa 181

Ошибки Kyocera TASKalfa 205c

Ошибки Kyocera TASKalfa 220

Ошибки Kyocera TASKalfa 2200

Ошибки Kyocera TASKalfa 2201

Ошибки Kyocera TASKalfa 221

Ошибки Kyocera TASKalfa 2420w

Ошибки Kyocera TASKalfa 2460ci

Ошибки Kyocera TASKalfa 2470ci

Ошибки Kyocera TASKalfa 250ci

Ошибки Kyocera TASKalfa 2510i

Ошибки Kyocera TASKalfa 2520i

Ошибки Kyocera TASKalfa 255

Ошибки Kyocera TASKalfa 2550ci

Ошибки Kyocera TASKalfa 2551ci

Ошибки Kyocera TASKalfa 2552ci

Ошибки Kyocera TASKalfa 2553ci

Ошибки Kyocera TASKalfa 255b

Ошибки Kyocera TASKalfa 255c

Ошибки Kyocera TASKalfa 265ci

Ошибки Kyocera TASKalfa 300ci

Ошибки Kyocera TASKalfa 300i

Ошибки Kyocera TASKalfa 3010i

Ошибки Kyocera TASKalfa 3011i

Ошибки Kyocera TASKalfa 305

Ошибки Kyocera TASKalfa 3050ci

Ошибки Kyocera TASKalfa 3051ci

Ошибки Kyocera TASKalfa 306ci

Ошибки Kyocera TASKalfa 307ci

Ошибки Kyocera TASKalfa 308ci

Ошибки Kyocera TASKalfa 3212i

Ошибки Kyocera TASKalfa 3252ci

Ошибки Kyocera TASKalfa 3253ci

Ошибки Kyocera TASKalfa 3500i

Ошибки Kyocera TASKalfa 3501i

Ошибки Kyocera TASKalfa 350ci

Ошибки Kyocera TASKalfa 3510i

Ошибки Kyocera TASKalfa 3511i

Ошибки Kyocera TASKalfa 3550ci

Ошибки Kyocera TASKalfa 3551ci

Ошибки Kyocera TASKalfa 3552ci

Ошибки Kyocera TASKalfa 3553ci

Ошибки Kyocera TASKalfa 356ci

Ошибки Kyocera TASKalfa 358ci

Ошибки Kyocera TASKalfa 4002i

Ошибки Kyocera TASKalfa 4003i

Ошибки Kyocera TASKalfa 400ci

Ошибки Kyocera TASKalfa 4012i

Ошибки Kyocera TASKalfa 4052ci

Ошибки Kyocera TASKalfa 4053ci

Ошибки Kyocera TASKalfa 406ci

Ошибки Kyocera TASKalfa 408ci

Ошибки Kyocera TASKalfa 420i

Ошибки Kyocera TASKalfa 4500i

Ошибки Kyocera TASKalfa 4501i

Ошибки Kyocera TASKalfa 4550ci

Ошибки Kyocera TASKalfa 4551ci

Ошибки Kyocera TASKalfa 4820w

Ошибки Kyocera TASKalfa 5002i

Ошибки Kyocera TASKalfa 5003i

Ошибки Kyocera TASKalfa 500ci

Ошибки Kyocera TASKalfa 5052ci

Ошибки Kyocera TASKalfa 5053ci

Ошибки Kyocera TASKalfa 508ci

Ошибки Kyocera TASKalfa 520i

Ошибки Kyocera TASKalfa 5500i

Ошибки Kyocera TASKalfa 5501i

Ошибки Kyocera TASKalfa 550c

Ошибки Kyocera TASKalfa 552ci

Ошибки Kyocera TASKalfa 5550ci

Ошибки Kyocera TASKalfa 5551ci

Ошибки Kyocera TASKalfa 6002i

Ошибки Kyocera TASKalfa 6003i

Ошибки Kyocera TASKalfa 6052ci

Ошибки Kyocera TASKalfa 6053ci

Ошибки Kyocera TASKalfa 620

Ошибки Kyocera TASKalfa 6500i

Ошибки Kyocera TASKalfa 6501i

Ошибки Kyocera TASKalfa 650c

Ошибки Kyocera TASKalfa 6550ci

Ошибки Kyocera TASKalfa 6551ci

Ошибки Kyocera TASKalfa 7002i

Ошибки Kyocera TASKalfa 7003i

Ошибки Kyocera TASKalfa 7052ci

Ошибки Kyocera TASKalfa 7353ci

Ошибки Kyocera TASKalfa 750c

Ошибки Kyocera TASKalfa 7550ci

Ошибки Kyocera TASKalfa 7551ci

Ошибки Kyocera TASKalfa 8000i

Ошибки Kyocera TASKalfa 8001i

Ошибки Kyocera TASKalfa 8002i

Ошибки Kyocera TASKalfa 8003i

Ошибки Kyocera TASKalfa 8052ci

Ошибки Kyocera TASKalfa 820

Ошибки Kyocera TASKalfa 8353ci

Ошибки Kyocera TASKalfa 9002i

Ошибки Kyocera TASKalfa 9003i

Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.

В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.

Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.

Код ошибки Описание ошибки Причина ошибки 0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. 0070 FAX control PWB incompatible detection Error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. FAX control PWB (The FAX PWB installed will not be the one designed for the machine. 0100 Backup memory device error EEPROM (Control PWB) 0120 MAC address data error
For data in which the MAC address is invalid. EEPROM (Control PWB) 0130 Backup memory read/write error (main NAMD) Flash memory (Control PWB) 0140 Backup memory data error (main NAND) Flash memory (Control PWB) 0150 Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM. 0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Defective PWB. 0180 Machine number mismatch
Machine number of control does not match. Data damage of EEPROM. 0600 Expanded memory (DIMM) installing error
The expansion memory modules (DIMM) are not correctly mounted. Improper installation expanded memory (DIMM). 0610 Expanded memory (DIMM) error
The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly. Defective expanded memory (DIMM). Defective main PWB. 0640 Hard disk error
The hard disk cannot be accessed. Defective hard disk. Defective main PWB. 0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB. Defective FAX software. Defective FAX control PWB. 0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Defective main PWB. 0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Defective FAX control PWB or main PWB. 0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. 0930 EEPROM bus error Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB. 1010 Lift motor error
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB. 1020 PF lift motor error (paper feeder 1)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1030 PF lift motor error (paper feeder 2)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1500 PF heater 1 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1510 PF heater 2 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1520 PF heater 1 high temperature error (paper feeder 2)
A temperature higher than 75aC/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1530 PF heater 2 high temperature error (paper feeder 2)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1600 PF heater 1 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1610 PF heater 2 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1620 PF heater 1 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1630 PF heater 2 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1800 Paper feeder communication error
Communication error between engine PWB and optional paper feeder. Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB. 2100 Developing motor error
The developing motor ready input is not given for 5 s during the main motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB. 2200 Drum motor error
The drum motor ready input is not given for 5 s during the drum motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB. 2330 Fuser pressure release motor error
When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2340 Fuser pressure release motor time-out error
When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2500 Paper feed motor error
The drum motor ready input is not given for 5 s during the paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB. 2600 PF paper feed motor error (paper feeder 1)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB 2610 PF paper feed motor error (paper feeder 2)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB. 2730 Developing release motor error
When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2740 Developing release motor time-out error
When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2820 Fuser motor error
The fuser motor ready input is not given for 5 s during the fuser motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB. 3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB. 3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3300 AGC error
After AGC, correct input is not obtained at CCD. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3500 Communication error between scanner and ASIC
An error code is detected. Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB. 4001 Polygon motor KM error
The polygon motor KM ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor KM. Defective engine PWB. 4002 Polygon motor CY error
The polygon motor CY ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor CY. Defective engine PWB. 4201 Laser output error (black)
The pin photo signal is not output from PD PWB K for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB. 4202 Laser output error (cyan)
The pin photo signal is not output from PD PWB C for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4203 Laser output error (magenta)
The pin photo signal is not output from PD PWB M for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4204 Laser output error (yellow)
The pin photo signal is not output from PD PWB Y for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4600 LSU cleaning motor error
When the LSU cleaning motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB. 4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB. 5301 Broken cleaning lamp K wire
When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5302 Broken cleaning lamp C wire
When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5303 Broken cleaning lamp M wire
When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5304 Broken cleaning lamp Y wire
When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 6000 Broken fuser heater wire
The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s in warming up. The fuser temperature does not reach 100„aC/212„aF after the fuser heater has been turned on continuously for 30 s in warming up. The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s during printing. Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6020 Abnormally high fuser thermistor temperature
The fuser thermistor detects a temperature higher than 240C/464F. By the activation of the high temperature error detection circuit (230C/446F or more) of fuser thermistor, the illumination of fuser heater was forcibly turned off and 10 s has elapsed. Shorted fuser thermistor. Defective engine PWB. 6030 Broken fuser thermistor wire
Input from fuser thermistor is 3 or less (A/D value) continuously for 1 s. Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6400 Zero-cross signal error
The zero-cross signal does not reach the engine PWB for more than 1 s. Defective connector cable or poor contact in the connector. Defective power source PWB or engine PWB 7001 Toner motor K error
When the toner motor K is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7002 Toner motor C error
When the toner motor C is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7003 Toner motor M error
When the toner motor M is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7004 Toner motor Y error
When the toner motor Y is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7401 Developing unit K noninstalling error
No density detection signal is output from toner sensor K in developing unit K. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7402 Developing unit C noninstalling error
No density detection signal is output from toner sensor C in developing unit C. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7403 Developing unit M noninstalling error
No density detection signal is output from toner sensor M in developing unit M. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7404 Developing unit Y noninstalling error
No density detection signal is output from toner sensor Y in developing unit Y. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7411 Drum unit K non- installing error
The EEPROM of drum PWB K does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7412 Drum unit C non- installing error
The EEPROM of drum PWB C does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7413 Drum unit M non- installing error
The EEPROM of drum PWB M does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7414 Drum unit Y non- installing error
The EEPROM of drum PWB Y does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 9500

9520 Contact the Service Administrative Division. 9530 Backup data error
The serial number of the machine written on the EEPROM of the engine PWB differs with that is written on both the flash memory of the engine PWB and the EEPROM of the drum PWB as a backup. Replacing both the engine PWB and the drum unit at the same time. F000 Main PWB — operation panel PWB communication error Defective main PWB. Defective operation panel PWB. F010 Main PWB checksum error Defective main PWB F020 Main PWB RAM checksum errors Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM). F040 Main PWB — print engine communication error Defective main PWB. Defective engine PWB. F041 Main PWB — scanner engine communication error Defective main PWB. Defective engine PWB. F050 Print engine ROM checksum error Defective engine PWB. F051 Scanner engine ROM checksum error Defective engine PWB. F278 Power supply in drive system error Main power switch was turned off without using the power key, or a power failure has occurred.

Code

7001

Toner motor K error

When the toner motor K is driven, the

toner motor K over-current detection sig-

nal is detected continuously for 50 times

(5 s) at 100 ms intervals.

7002

Toner motor C error

When the toner motor C is driven, the

toner motor C over-current detection sig-

nal is detected continuously for 50 times

(5 s) at 100 ms intervals.

7003

Toner motor M error

When the toner motor M is driven, the

toner motor M over-current detection sig-

nal is detected continuously for 50 times

(5 s) at 100 ms intervals.

Contents

Causes

Check procedures/corrective measures

Defective harness

Reinsert the connector. Also check for conti-

between toner

nuity within the connector harness. If none,

motor K and

remedy or replace the harness.

engine PWB

(YC22), or

improper connec-

tor insertion.

Defective drive

Check if the gears rotate smoothly. If not,

transmission

grease the bushings and gears. Check for

system of the toner

broken gears and replace if any.

motor K.

Defective toner

Replace the toner motor K.

motor K.

Defective engine

Replace the engine PWB (See page 1-5-

PWB.

29).

Defective harness

Reinsert the connector. Also check for conti-

between toner

nuity within the connector harness. If none,

motor C and

remedy or replace the harness.

engine PWB

(YC24), or

improper connec-

tor insertion.

Defective drive

Check if the gears rotate smoothly. If not,

transmission

grease the bushings and gears. Check for

system of the toner

broken gears and replace if any.

motor C.

Defective toner

Replace the toner motor C.

motor C.

Defective engine

Replace the engine PWB (See page 1-5-

PWB.

29).

Defective harness

Reinsert the connector. Also check for conti-

between toner

nuity within the connector harness. If none,

motor M and

remedy or replace the harness.

engine PWB

(YC25), or

improper connec-

tor insertion.

Defective drive

Check if the gears rotate smoothly. If not,

transmission

grease the bushings and gears. Check for

system of the toner

broken gears and replace if any.

motor M.

Defective toner

Replace the toner motor M.

motor M.

Defective engine

Replace the engine PWB (See page 1-5-

PWB.

29).

Remarks

2K8

1-4-15

Модератор: vetal

Правила форума
ВНИМАНИЕ! ПЕРЕЕЗД ФОРУМА!

{ TOPIC_LOCKED_SHORT }

Сообщений: 8
• Страница 1 из 1

Прилепить пост

Сообщение Алишер Рузиев » Чт апр 27, 2017 5:05 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑При включение мфу пишет добавление тонера и выходит ошибка «Сбой, вызовите сервисный персонал С7002», грешил на то что тонер кончился
вытащили картриджи еще не пустые, бункер отхода чистили, подскажите может кто сталкивался с такой ошибкой.

Аватар пользователя

Алишер Рузиев

  

Понюхал тонер

  • Не в сети
  • Персональный альбом

Вернуться наверх


Прилепить пост

Сообщение Goldwater » Чт апр 27, 2017 11:23 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑А при чем тут тонер? Это ошибка мотора, а не тонера.

Аватар пользователя

Goldwater

  

Избран тонером

  • Не в сети

Вернуться наверх


Прилепить пост

Сообщение Алишер Рузиев » Пт апр 28, 2017 10:36 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Есть у вас подробное описание ошибки? гугл не дал результата.

Аватар пользователя

Алишер Рузиев

  

Понюхал тонер

  • Не в сети
  • Персональный альбом

Вернуться наверх


Прилепить пост

Сообщение Goldwater » Пт апр 28, 2017 12:23 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Да ладно заливать-то.

https://yandex.ru/search/?text=Kyocera% … ror&lr=213

Аватар пользователя

Goldwater

  

Избран тонером

  • Не в сети

Вернуться наверх


Прилепить пост

Сообщение Алишер Рузиев » Пт апр 28, 2017 3:14 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑в поиске искал описание ошибки С7002, а у вас в поисковой строке «Kyocera 7002 motor error», я не знал что это ошибка мотора. Так как при поиске именно по коду ни каких описаний не выдает.

Аватар пользователя

Алишер Рузиев

  

Понюхал тонер

  • Не в сети
  • Персональный альбом

Вернуться наверх


Прилепить пост

Сообщение Goldwater » Пт апр 28, 2017 3:43 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Я вам еще вчера написал, «чья» это ошибка.

Аватар пользователя

Goldwater

  

Избран тонером

  • Не в сети

Вернуться наверх


Прилепить пост

Сообщение rondol » Вс апр 30, 2017 8:44 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Попробовать насыпать тонеру в проявку,мимо мотора,чтоб он не начинал сосать,и посмотреть,что будет

Аватар пользователя

rondol

  

Добрался до абсорбера

  • Не в сети
  • Персональный альбом

Вернуться наверх


Прилепить пост

Сообщение Goldwater » Вс апр 30, 2017 11:22 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Стопудово будет та же самая ошибка. Тонер-моторы проверяются и при стартовой инициализации.

Аватар пользователя

Goldwater

  

Избран тонером

  • Не в сети

Вернуться наверх


Показать сообщения за:
Сортировать по:


{ TOPIC_LOCKED_SHORT }

Сообщений: 8
• Страница 1 из 1

Вернуться в Принтеры, МФУ, факсы, копиры формата A4

Перейти:

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 113

Индикатор ошибки на Kyocera TASKalfa 1800/2200Если с аппаратом Kyocera TASKalfa 1800, Kyocera TASKalfa 2200 произошла проблема, откроется следующий экран с уведомлением.
• Индикатор [Внимание] на панели управления горит или мигает.
• На дисплее сообщений панели управления аппарата появилось сообщение об ошибке.

Если индикатор [Внимание] горит или мигает и на дисплее сообщений панели управления аппарата появилось сообщение об ошибке, проверьте KYOCERA Client Tool или Монитор состояния.

ПРИМЕЧАНИЕ Если индикаторы постоянно горят и мигают не так, как описано выше, вероятно, произошла ошибка службы. Выключите питание, отсоедините шнур питания и вставьте его обратно, после чего включите питание. Это может помочь сбросить ошибку. Если ошибка не исчезает, свяжитесь со своим представителем сервисной службы (тел. в Минске +375 17 291-28-24)

Ниже описаны неполадки, которые не могут быть устранены пользователем

Дисплей сообщений

Описание

Меры устранения

Бункер отраб тонера перепол. или не уст.

Бункер для отработанного тонера установлен неправильно

Установите Бункер для отработанного тонера должным образом

Бункер для отработанного тонера заполнен

Замените бункер отработанного тонера

Встряхните картр. с тонером

Тонер слежался

Откройте переднюю крышку аппарата и вытяните контейнер с тонером. Сильно встряхните контейнер с тонером и установите его на место

Вызовите сервисный персонал.

В аппарате произошла ошибка

Обратите внимание на код ошибки, отображаемый в дисплее сообщений, и свяжитесь с представителем сервисной службы (тел. в Минске +375 17 291-28-24)

Выньте бумагу с внутреннего лотка

 

Извлеките бумагу из внутреннего лотка. Нажмите клавишу [OK], чтобы возобновить печать

Добавьте тонер

Закончился тонер

Замените контейнер с тонером TK-4105

Загрузите бумагу в кассету #

↑↓ (отображается попеременно)
A4 (формат бумаги)
Обычная (тип носителя)
OK: Перейдите к следующему шагу

Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.]

Загрузите бумагу в универсальный лоток

↑↓ (отображается попеременно)
A4 (формат бумаги)
Обычная (тип носителя)
OK: Перейдите к следующему шагу

Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.]

Закройте автоподатчик оригиналов

Открыт автоподатчик оригиналов

Откройте и закройте автоподатчик оригиналов

Закройте крышку автопод. оригиналов

Открыта верхняя крышка автоподатчика оригиналов

Откройте и закройте крышку автоподатчика оригинало

Закройте переднюю крышку

Открыта передняя крышка

Откройте и закройте переднюю крышку

Закройте правую крышку #

Открыта какая-либо крышка

Откройте и закройте крышку, обозначенную на экране

Замятие бумаги. (DP)
↑↓ (отображается попеременно)
Проверьте (B)(C) в крышке DP

В автоподатчике произошло замятие бумаги.

См. Устранение замятия бумаги в Руководстве по эксплуатации и извлеките замятую бумагу

Замените МК

Необходимо производить замену деталей комплекта техобслуживания MK-4105 (ремкомплекта) каждые 150 000 страниц печати.

Данная операция должна производиться специалистом. Обратитесь к представителю сервисной службы (тел. в Минске +375 17 291-28-24)

Замятие

Произошло замятие бумаги в кассете или универсальном лотке

См. Устранение замятия бумаги и извлеките замятую бумагу

Извлеките оригиналы из автоподатчика

Для продолжения работы необходимо извлечь оригиналы из автоподатчика оригиналов

Извлеките оригиналы из автоподатчика оригиналов

Кабель USB был отключен

Кабель USB не подключен

Нажмите клавишу [OK] и подключите кабель USB

ПК выключен

Нажмите клавишу [OK] и включите ПК

Не удается найти KYOCERA Client Tool

Нажмите клавишу [OK] и откройте KYOCERA Client Tool на ПК

Макс. к-во сканируемых страниц

Превышен предел сканирования

Дальнейшее сканирование невозможно. Задание отменено. Нажмите клавишу [OK]

Мало тонера. (Зам., когда законч.)

Скоро понадобится заменить контейнер с тонером 

Получите новый контейнер с тонером TK-4105. 
Внимание! Когда заканчивается тонер аппарат перестает печатать

Не оригинальный тонер

Установлен контейнер с тонером не марки Kyocera

Производитель не несет ответственности за повреждения, вызванные использованием неоригинального тонера. Мы рекомендуем использовать исключительно оригинальные контейнеры с тонером  TK-4105. .
Если нужно использовать установленный в настоящее время контейнер с тонером, нажмите одновременно и удерживайте клавиши [OK] и [Стоп] в течение не менее 3 с.

Неверный ид. уч. зап. Задание отменено

Указан неверный идентификатор учетной записи при внешней обработке задания. Задание отменено

Нажмите клавишу [OK]

Невозможна двусторонняя печать на этой бумаге

Не возможна печать на бумаге выбранного формата или типа

Нажмите клавишу [OK] и перейдите к следующему шагу:
• Для выбора другого устройства подачи выберите пункт [Выберите бумагу].
• Чтобы печатать, не используя функцию двусторонней печати, выберите пункт [Продолж. без изм.].

Недостаточно памяти. Невозможно начать выполнение задания

Невозможно начать выполнение задания

Повторите попытку позже

Ограничено алгоритмом учета заданий(Печать)

Задание отменено, поскольку его выполнение ограничено функцией учета заданий

Нажмите клавишу [OK]

Ограничено алгоритмом учета заданий(Сканер)

Задание отменено, поскольку его выполнение ограничено функцией учета заданий

Нажмите клавишу [OK]

Очистите сканер

Произошло загрязнение сканера

Очистите щелевое стекло с помощью чистящей салфетки, поставляемой вместе с автоподатчиком оригиналов.

Ошибка. Выключить

Отключите и снова включите аппарат с помощью выключателя питания

Память переполнена

Невозможно продолжить выполнение задания из-за отсутствия свободной памяти

Измените разрешение печати с Быстр1200 до 600 dpi. См. Printer Driver User Guide

Память сканера переполнена

Дальнейшее сканирование невозможно из-за нехватки памяти сканера.

Для отмены задания нажмите [OK]

Перезагрузка печати. Задание отменено

Предупреждение. Недостаточно памяти принтера. Задание отменено

Нажмите клавишу [OK]

Превышено ограничение учета заданий

Превышено число распечаток из-за ограничения алгоритмом учета заданий. Достигнут предел печати

Это задание отменено. Нажмите клавишу [OK]

Уст.другую кассету

Выбрано «Сдвиг»

Для использования сдвига необходимо загрузить в другой лоток бумагу такого же формата, что и в выбранном устройстве подачи, но в другой ориентации

Установите все оригиналы обратно и нажмите клавишу [Старт].

Возникает при печати двусторонних документов в режиме ручной двусторонней печати

Извлеките оригиналы из автоподатчика оригиналов, расположите их в первоначальном порядке и положите обратно. Нажмите клавишу [OK], чтобы возобновить печать. Для отмены задания нажмите [Стоп]

Установлен неизвестный тонер. ПК

Региональная спецификация контейнера с тонером не соответствует спецификации аппарата

Установите оригинальный контейнер с тонером Замените контейнер с тонером TK-4105

Понравилась статья? Поделить с друзьями:
  • Kyocera 2135 ошибка 2000
  • Kyocera 6525 ошибка 6050
  • Kyocera 2135 коды ошибок
  • Kyocera 4200 коды ошибок
  • Kyocera 6525 ошибка 4803