Msz ge22va коды ошибок

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Before taking measures, make sure that the symptom reappears for accurate troubleshooting.

When the indoor unit has started operation and detected an abnormality of the following condition (the first detection after the

power ON), the indoor fan motor turns OFF and OPERATION INDICATOR lamp flashes.

OPERATION INDICATOR

Abnormal

No.

Operation indicator lamp

point

Upper lamp fl ashes.

0.5-second ON

Miswiring

1

or serial

signal

0.5-second OFF

Upper lamp fl ashes.

Indoor coil

2-time fl ash

thermistor

2

Room tem-

perature

2.5-second OFF

thermistor

Upper lamp fl ashes.

3-time fl ash

Indoor fan

3

motor

2.5-second OFF

Upper lamp fl ashes.

4-time fl ash

Indoor con-

4

trol system

2.5-second OFF

Upper lamp fl ashes.

5-time fl ash

Outdoor

5

power sys-

tem

Upper lamp fl ashes.

6-time fl ash

Outdoor

6

thermistors

Upper lamp fl ashes.

7-time fl ash

Outdoor

7

control sys-

tem

Upper lamp fl ashes.

14-time fl ash

Other ab-

8

normality

2.5-second OFF

Outdoor

9

control sys-

Upper lamp lights up

tem

Lighted

Blinking

Not lighted

Symptom

Indoor unit and

outdoor unit do

not operate.

2.5-second OFF

2.5-second OFF

2.5-second OFF

Outdoor unit

does not oper-

ate

www.ilmalämpöpumput.com

Condition

The serial signal from the outdoor unit is not

received for 6 minutes.

The indoor coil or the room temperature ther-

mistor is short or open circuit.

The rotational frequency feedback signal is

not emitted during the indoor fan operation.

It cannot properly read data in the nonvolatile

memory of the indoor electronic control P.C.

board.

It consecutively occurs 3 times that the com-

pressor stops for overcurrent protection or

start-up failure protection within 1 minute after

start-up.

The outdoor thermistors short or open circuit

during the compressor operation.

It cannot properly read data in the nonvolatile

memory of the inverter P.C. board or the out-

door electronic control P.C. board.

An abnormality other than above mentioned

is detected.

It cannot properly read data in the nonvolatile

memory of the inverter P.C. board or the out-

door electronic control P.C. board.

22

Correspondence

Refer to 10-6.

«How to check

miswiring and serial signal er-

ror».

Refer to 10-7. the character-

istics of indoor coil thermistor,

and the room temperature ther-

mistor.

Refer to 10-6.

«Check of in-

door fan motor».

Replace the indoor electronic

control P.C. board.

Refer to «How to check of in-

verter/compressor».

Refer to outdoor unit service

manual

Check the stop valve.

Refer to «Check of outdoor

thermistor».

Refer to outdoor unit service

manual.

Replace the inverter P.C. board

or the outdoor electronic control

P.C. board.

Refer to outdoor unit service

manual.

Check the stop valve.

Confi rm the abnormality in

detail using the failure mode

recall function for outdoor unit.

Check the blinking pattern of

the LED on the inverter P.C.

board or the outdoor electronic

control P.C. board.

1. Меры предосторожности

1) Перед поиском неисправности проверьте Перед поиском неисправности проверьте питание блоков, а также правильность соединения наружного
и внутреннего приборов.
2) Сначала выключите кондиционер с пульта ДУ, убедитесь, что жалюзи закрылись, и только после этого выключайте питание.
3) Когда вынимаете платы, не повредите компоненты платы.
4) При отключении разъемов не тяните за провод.

2. Процедура поиска неисправностей

1) Проверьте, не мигает ли индикаторная лампочка, указывая на неисправность. Установите количество и периодичность миганий, чтобы определить ошибку.
2) Если есть предположение, что плата дефектна, проверьте визуально наличие плохих контактов, сгоревших компонентов.

3. Как менять батарейки

Слабые батарейки могут быть причиной ошибочной работы пульта ДУ.
В этом случае пульт нельзя восстановить просто заменой батареек! После замены батареек обязательно нажмите кнопку «сброс»(reset).

1) Замените батареи и установите крышку

2) Нажмите кнопку сброса “RESET”

Примечание 1 : Если не нажать кнопку “RESET” пульт ДУ может неправильно функционировать.

4. Установка горизонтальной заслонки (направляющей воздушного потока)

Если горизонтальная направляющая воздушного потока установлена неправильно, то на панели индикации мигают все светодиоды. Выключите питание блока и проверьте правильность установки следующим образом:

5. Информация по мультисистемам — наружные блоки серии MXZ: MXZ-3A54VA, MXZ-4A71VA, MXZ-4A80VA, MXZ-8A140VA

Мультисистема — это два или более внутренних блоков, подключенные к одному наружному агрегату.

  • Следует проверить, что суммарная производительность внутренних блоков не превышает мощность наружного блока. В противном случае эксплуатация системы невозможна: светодиод мигает, указывая на неисправность.
  •  Наружный блок включается в режим, соответствующий режиму работы первого включеного блока. Если последующий блок включен в другой режим, то блок работать не будет и при этом будет мигать правый индикатор, как показано ниже. Все блоки мультисистемы должны быть включены в одинаковый режим: охлаждение или обогрев.

  • Если внутренний блок включается в режим обогрева в то время, когда наружный агрегат находится в режиме оттаивания, то возможна задержка подач. и теплого воздуха из внутреннего блока (не более чем на 10 минут).
  • При работе системы в режиме обогрева даже выключенный внутренний блок может становиться теплым и может быть слышен небольшой шум хладагента. Это не является несправностью и обусловлено движением некоторого количества хладагента через выключенные блоки.

6. Принудительное включение (тестовый запуск)

 Для принудительного включения системы, а также для запуска тестового режима нажмите кнопку „EMERGENCY OPERATION”, расположенную в правой части под крышкой прибора. Режим принудительного запуска может быть использованпри отсутствии пульта управления или при его неисправности. Блок включается и загорается индикатор „AREA”.

Первые 30 минут после включения блок работает в тестовом режиме. Вентилятор внутренннего блока работает на высокой скорости вращения. Режим охлаждения или обогрева включен постоянно вне зависимости от температуры в помещении.

Спустя 30 минут работы в тестовом режиме блок переключается в режим Принудительного охлаждения/Принудительного обогрева с целевой температурой 24 градуса, а скорость вертиялтора переключается на среднюю.

В принудительном режиме сохраняются все защитные функции системы, например, защита от обмерзания теплообменника внутреннего блока.
В принудительном режиме, а также в режиме тестового запуска горизонтальная воздушная заслонка работает в автоматическом режиме VANE AUTO.
Режим принудительного включения продолжается до тех пока не будет один или два раза нажата кнопка „EMERGENCY OPERATION” или до получения любой команды от пульта управления. В последнем случае блок переключится в обычный режим.

Примечание:
Не нажимайте кнопку „EMERGENCY OPERATION” во время нормальной работы системы.

Режим работы охлаждение обогрев
Целевая температура 24°С 24°С
Скорость вентилятора средняя средняя
Горизонтальная заслонка авто авто
Вертикальная заслонка прямо прямо

Режим работы индицируется с помощью светодиодов AREA

Примечание.
В принудительном режиме индикатор „AREA” задействован под указание режима работы. Настройка рабочей зоны в этом режиме невозможна.

3-минутная задержка включения

После отключения системы компрессор не может быть включен повторно в течение следующих 3 минут. Эта задержка реализована специально для защиты компрессора от перегрузки.

7. Проверка последних неисправностей в системе Mitsubishi Electric MSZ-FD_VA

Информация о неисправности фиксируется и сохраняется в памяти кондиционеров Mitsubishi Electric MSZ-FD_VA. Поэтому даже после восстановления работоспособности можно проверить, что случилось с системой. Этот режим удобен для диагностики систем, неисправность в которых повторно не появляется.

а) Последовательность проверки последних неисправностей

 

 

Примечания:

1) Убедитесь, что режим проверки последних ошибок завершен. В противном случае нормальная работа невозможна.
2) Если очистка памяти не произведена, то информация о последней неисправности сохраняется в памяти.

 W 2. Мигание светодиода при неисправности внутреннего блока

 

  W 3. Мигание светодиода при неисправности наружного блока

 б) Последовательность проверки последних неисправностей плазменного фильтра

 

 Примечания:

1) Убедитесь, что режим проверки последних ошибок завершен. В противном случае нормальная работа невозможна.
2) Если очистка памяти не произведена, то информация о последней неисправности сохраняется в памяти.

 W2. Мигание светодиода при неисправности

 

 в) Проверка питания плазменного фильтра

Питание на плазменный электрод подается после однократного нажатия на кнопку “PLASMA” на пульте управления во время индикации ошибок внутреннего блока или после короткого подтверждающего звукового сигнала.

Индикатор 
PLASMA
Описание
постоянно мигает См. разделы „Проверка питания плазменного электрода” для идентификации неисправности.
мигает 2 раза Неисправны цепи питания плазменного электрода на плате управления внутреннего блока.
выключен Неисправности нет.

 Примечание: Указанные проверки следует производить только при закрытой передней панели.

г) Таблица кодов ошибок внутренних блоков Mitsubishi Electric MSZ-FD_VA (индикация последней неисправности)

Примечание: индикация в режиме проверки последних неисправностей отличается от индикации текущих неисправностей приборов.

Светодиод
POWER
неисправность способ определения способ устранения
выключен нет
мигает 1 раз
каждые 0.5сек
термистор комнатной
температуры
Обрыв или короткое замыкание
термистора определяется каждые 8 секунд при работе блока
Проверьте сопротивление термистора
мигает 2 раза
2.5сек ВЫКЛ
термистор на
теплообменнике
Обрыв или короткое замыкание
термистора определяется каждые
8 секунд при работе блока
Проверьте сопротивление термистора
мигает 3 раза
2.5сек ВЫКЛ
обмен данными между
наружным и внутренним
блоками
Последовательный сигнал от наружного
блока не приходит более 6 минут
Проверьте соединение наружного и
внутреннего блоков
мигает 11 раз
2.5сек ВЫКЛ
электродвигатель
вентилятора
Сигнал с датчика вращения э/двигателя не поступает в течении 12 секунд при
включенном двигателе
Проверьте э/двигатель вентилятора
мигает 12 раз
2.5сек ВЫКЛ
внутренняя неисправность 
схемы управления
Данные из памяти не могут быть
правильно считаны
Замените плату внутреннего блока

д) Таблица кодов неисправностей питания плазменного электрода (индикация последней неисправности)

Светодиод
POWER
неисправность способ определения способ устранения
мигает 1 раз Контроль питания
плазменного элетрода
Питание плазменного электрода не отключается при выключении с пульта управления. Замените плату управления
внутреннего блока
мигает 2 раза Искровой разряд Напряжение на разъеме CN1: 1(+) и 2(-) платы питания плазменного элетрода падает ниже 1.6В. См. разделы „Проверка питания
плазменного электрода”.
мигает 3 раза Электрический разряд:
ошибка 1
Напряжение на разъеме CN1: 1(+) и 2(-) платы питания плазменного элетрода падает на 0.9В ниже границы допустимого диапазона (3 В).
мигает 4 раза Электрический разряд:
ошибка 2
Напряжение на разъеме CN1: 1(+) и 2(-) платы питания плазменного элетрода падает значительно: 0.4В / 0.5мс
мигает 5 раз Питание плазменных
фильтров
Напряжение на разъеме CN1: 1(+) и 2(-) платы питания плазменного электрода превышает нормальное напряжение (3В).

 Примечание:

 1) Индикация в режиме проверки последних неисправностей отличается от индикации текущих
неисправностей приборов.

2) При возникновении неисправности питание плазменного электрода отключается. Поэтому для
проверки напряжения требуется измерительный прибор с памятью.

3) Если светодиод POWER мигает 1 или 2 раза, то проверьте работу цепей плазменного элетро-
да.

8. Индикация неисправностей

Мигание светодиода “POWER” на панели индикации обозначает неисправность

Примечание: Перед проверкой убедитесь, что симптомы повторяются.

 No.  Неисправность  Индикация  системы MITSUBISHI —————————————————————-кондиционирования-воздуха  Описание  Способ определения  Способ устранения
 1 обмен
данными
между
блоками
  Внутренний
и наружный
блоки не
работают
       
Последовательный сигнал от наружного блока не приходит более 6 минут Проверьте соединение наружного и внутреннего блоков
 2 термистор
на тепло-
обменнике
  Один из термисторов (комнатной температуры или теплообменника): обрыв или замыкание. Проверьте сопротивление термистора (см. зависимость сопротивления от темпратуры)
термистор
комнатной
темпера-
туры
 3 Э/двигатель
вентилятора
внутреннего
блока
  Сигнал с датчика вращения э/двигателя не поступает в течении 12 секунд при включенном двигателе Проверьте э/двигатель вентилятора
 4 неисправ-
ность
платы
наружного
блока
  Данные из памяти (плата инвертора или плата управления) не могут быть правильно считаны Замените плату инвертора или плату управления в наружном блоке
 5 силовые
цепи
наружного
блока
  3 раза подряд компрессор останавливается из-за превышения тока или защита при запуске в течении 1 минуты после пуска компрессора. См. раздел “Проверка инвертора и компрессора”. Проверьте вентили наружного блока
 6 термисторы
наружного
блока
  Термисторы наружного блока: обрыв или замыкание — при включенном компрессоре. Проверьте термисторы наружного блока
 7 неисправ-
ность
платы
наружного
блока
  Данные из памяти (плата инвертора или плата управления) не могут быть правильно считаны Замените плату инвертора или плату управления наружного блока. См. раздел наружных блоков.
 8 другие
неисправ-
ности
  Другие неисправности, кроме перечисленных выше. Используйте режим проверки последних неисправностей
 9 неисправ-
ность
платы
наружного блока
  Наружный
блок не
работает
Данные из памяти (плата инвертора или плата управления) не могут быть правильно считаны Проверьте мигание светодиодов на платах наружного блока

Мигание всех светодиодов на панелииндикации обозначает неисправность.

No. Неисправность Индикация Описание Способ определения Способ устранения
 1 Горизонтальная
заслонка
неправильно
установлена
  Внутренний
и наружный
блоки не
работают

Концевой выключатель воздушной заслонки
разомкнут

См. раздел “Установка
горизонтальной заслонки”

Мигание обоих светодиодов “AREA” на панели индикации обозначает неисправность. Светодиод „POWER” включен.

No. Неисправность Индикация —————————————————————————————— Описание Способ определения Способ устранения
 1 Различная
установка
режимов
  Наружный
блок работает,
внутренний
— нет
Если часть внутренних блоков, подключенных к одному наружному, включили в режиме охлаждения (осушения), а часть — в режиме обогрева, то в системе устанавливается тот
режим, который был задан первым.
Установите одинаковый
режим работы внутренних блоков
 

Мигание светодиода “PLASMA” на панели индикации обозначает неисправность

No. Неисправность Индикация——————————————————————— Описание Способ определения Способ устранения
 1 Управление
питанием
плазменного
электрода
  Внутренний
и наружный
блоки не
работают
Питание плазменного электрода не может быть отключено с помощью пультауправления.  См. раздел „Проверка цепей
плазменного электрода”

Примечание: Если после подачи питания и включения внутреннего блока впервые фиксируется неисправность, то вентилятор внутреннего блока выключается, а светодиод «POWER» на панели индикации начинает мигать.

9. Характеристики основных компонентов MSZ-FD25VA, MSZ-FD35VA

 

 10. Алгоритмы поиска неисправности MSZ-FD25/35VA

 A Проверка электродвигателя вентилятора кондиционера Mitsubishi Electric MSZ-FD25/35VA

 Левый светодиод на панели индикации мигает 3 раза. Вентилятор внутреннего блока не работает.

B Поверка пульта управления и фотоприемника

Внутренний блок работает при нажатии кнопки принудительного включения, но не управляется с пульта.

C Проверка правильности установки воздушной заслонки

Все светодиоды на панели индикации внутреннего блока мигают.
Внутренний и наружный блоки не работают.

 

D Проверка платы внутреннего блока и электродвигателя вентилятора

Внутренний блок не управляется с пульта.
Светодиод “POWER” на панели индикации не включается при нажатии кнопки принудительного включения.

 

E Проверка межблочного соединения и неисправности последовательного интерфейса

Светодиод “Power” (питание) на внутреннем блоке мигает. Наружный блок не работает.

 

 F Проверка цепей питания плазменного электрода

Индикатор „PLASMA” мигает 2 раза.
Светодиод „POWER” мигает 1-5 раз в режиме проверки последних неисправностей плазменного электрода.

 

Error Расшифровка Русский перевод
P1 Intake sensor error Ошибка датчика на входе
P2 Pipe (TH5) sensor error Ошибка датчика теплообменника ТН5 (по схеме)
P4 Drain sensor error/Float switch connector (CN4F) open Переполнение дренажного поддона, или обрыв поплавкового датчика CN4F
P5 Drain pump error Ошибка дренажной помпы
P6 Freezing/Overheating protection operation Ошибка по обмерзанию или перегреву
P8 Pipe temperature error
P9 Pipe (TH2) sensor error Ошибка по датчику теплообменника ТН2
PA Forced compressor stop(due to water leakage abnormality) Принудительная остановка компрессора (из-за переполнения дренажной системы)
E0, E3 Remote controller transmission error Нет связи с пультом управления
E1, E2 Remote controller control board error Неисправна плата пульта управления
E4, E5 Remote controller signal receiving error
E9 Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) Нет связи между внутренним и внешним блоком (Ошибка на внешнем блоке)
EE Communication error between indoor and outdoor units Отсутствует межблочная связь между внутренним и внешним блоками
U1,Ud Abnormal high pressure (63H worked)/Overheating protection operationс Высокое давление по датчику 63Н, или защита от перегрева
U2 Abnormal high discharging temperature/49C worked/insufficient refrigerant Сработал датчик 49С, очень низкое давление нагнетания, недостаток хладагента
U3, U4 Open/short of outdoor unit thermistors Обрыв, короткое замыкание термодатчика внешнего блока
U5 Abnormal temperature of heat sink Температура конденсатора не соответствует норме
U6 Compressor overcurrent interruption/Abnormal of power module Компрессор принудительно остановлен по токовой перегрузке, неисправен силвой модуль
U7 Abnormality of super heat due to low discharge temperatureAbnormal high discharging temperature/49C worked/insufficient refrigerant Сработал датчик 49С / очень низкое давление нагнетания / недостаток хладагента
U8 Outdoor unit fan protection stop Двигатель вентилятора внешнего блока остановлен
U9, UH Abnormality such as overvoltage or voltage shortage and abnormal synchronous signal to main circuit/Current sensor error Повышенное / пониженное напряжение питания, неисправность токового датчика
UF Compressor overcurrent interruption (When compressor locked) Компрессор остановлен из-за токовой перегрузки, компрессор заклинило
UP Compressor overcurrent interruption Остановка компрессора из-за перегрузки по току
Fb Indoor unit control system error (memory error, etc.) Ошибка платы управления внутреннего блока (EEPROM и т.д.)

Определить ошибку в бытовых сплит системах можно по миганию индикаторов на панели внутреннего блока.

Получить расшифровку всех возможных кодов холодильного оборудования Mitsubishi Electric можно на сайте:

Язык оригинальной документации — английский.

Компания Mitsubishi Electric разработала программу для телефонов с помощью которой можно получить расшифровку кода ошибок.

Любой кондиционер Mitsubishi имеет функцию самодиагностики. При включении и во время работы микропроцессор через множество датчиков проверяет ошибки кондиционера Mitsubishi Heavy, чтобы вовремя остановить его работу при нарушении параметров.  Все ошибки Митсубиси Хэви делятся на 2 вида:

— аварийные, например, неисправность компрессора;

— информационные, например, сообщение о загрязнённом фильтре.

Большинство ошибок можно сбросить переключением электропитания, но при 3-5 кратном повторе в течение часа кондиционер может остановиться полностью, до устранения неисправности сервисным специалистом.

Кондиционер Mitsubishi коды ошибок сообщает пользователю световой индикацией, а при использовании проводного пульта также текстом на экране. 

В бытовых сериях используются только ИК-пульты, поэтому коды ошибок кондиционера Митсубиси можно определить по количеству миганий двух индикаторов: «Run» зелёного цвета и «Timer» жёлтого цвета. Для инверторных и On/Off моделей разных лет выпуска одна и та же ошибка может высвечиваться по-разному. 

В полупромышленных и мультизональных сериях преимущественно устанавливают проводные пульты, где коды ошибок Митсубиси Хэви можно прочитать с ЖК-экрана пульта, RC-E5 или RC-EX1.

Ошибки кондиционера Митсубиси Хеви обозначаются буквой Е (error) и двузначным числом. Все коды ошибок кондиционеров Mitsubishi Heavy являются универсальными для бытовых, полупромышленных и мультизональных серий. Т.е. код Е5, например, будет означать «Отсутствие связи между внутренним и наружным блоком» для любого кондиционера MHI. 

Ошибки Mitsubishi Heavy бытовых серий

Run Timer Ошибка кондиционера Митсубиси
1-кратное мигание Постоянно светится E6
2-кратное мигание Постоянно светится  E7
3-кратное мигание  Постоянно светится E6
4-кратное мигание  Постоянно светится E9
5-кратное мигание  Постоянно светится E47
6-кратное мигание  Постоянно светится E16
7-кратное мигание  Постоянно светится E57
Постоянно мигает  1-кратное мигание  E38
Постоянно мигает  2-кратное мигание E37
Постоянно мигает 4-кратное мигание  E39
Постоянно светится 1-кратное мигание E42
Постоянно светится 2-кратное мигание E59
Постоянно светится 3-кратное мигание E58
Постоянно светится 4-кратное мигание E51
Постоянно светится 5-кратное мигание E36
Постоянно светится 6-кратное мигание E5
Постоянно светится 7-кратное мигание E48
Постоянно светится  Постоянно мигает E35
2-кратное мигание 2-кратное мигание E60
Не светится 5-кратное мигание E5
3-кратное мигание 5-кратное мигание E35
3-кратное мигание 6-кратное мигание E36
3-кратное мигание 7-кратное мигание E37
3-кратное мигание 8-кратное мигание E38
3-кратное мигание 9-кратное мигание E39
4-кратное мигание 2-кратное мигание E42
4-кратное мигание 7-кратное мигание E47
4-кратное мигание 8-кратное мигание E48
5-кратное мигание 1-кратное мигание E51
5-кратное мигание 3-кратное мигание E53
5-кратное мигание 7-кратное мигание E57
5-кратное мигание 8-кратное мигание E58
5-кратное мигание 9-кратное мигание E59
6-кратное мигание Не светится E60
6-кратное мигание 1-кратное мигание E61
6-кратное мигание 2-кратное мигание E62
7-кратное мигание  1-кратное мигание  E40
8-кратное мигание Не светится E80
8-кратное мигание 2-кратное мигание E82
8-кратное мигание 4-кратное мигание E84
8-кратное мигание 5-кратное мигание E85
8-кратное мигание 6-кратное мигание E86

В полупромышленном и мультизональном оборудовании коды ошибки Mitsubishi Heavy с E1 до E31 относятся к внутренним блокам и высвечиваются только на пульте проблемного блока. Коды ошибок Митсубиси Хеви с номерами E32 — E75 относятся к наружным блокам и показываются на всех проводных пультах данного фреонового контура.

Кондиционеры Mitsubishi Heavy ошибки

Коды ошибок Mitsubishi Описание ошибок Митсубиси Возможные причины ошибки Митсубиси Хеви
E1 Ошибка соединения пульта управления • Плохой контакт или обрыв сигнального провода
• Электромагнитные наводки на кабель
• Неисправность  PCB внутреннего блока или пульта ДУ
E2 Двойной адрес внутреннего блока • Количество подключенных блоков превышает лимит.
• Двойной адрес внутреннего блока.
• Дефект PCB управления внутреннего блока.
E3 Ошибка сигнальной линии Возникает при полном отсутствии связи между всеми внутренними и внешними блоками. Если появляется соединение между внутренними и внешними блоками, ошибка меняется на E5. В обоих случаях проверьте предохранители и провода сигнальной линии. Проверить заданный номер наружного блока.
E5 Ошибка межблочной связи Если соединение между внутренним и внешним блоками отсутствует более 2 минут.
• Сбой питания внешнего блока
• Смена полярности А и B после подачи питания.
E6 Неисправен датчик 1 (2) теплообменника внутреннего блока • Дефект соединителя датчика теплообменника внутреннего блока
• Дефект датчика теплообменника внутреннего блока
• Неисправность PCB управления внутреннего блока
E7 Неисправен датчик температуры комнатного воздуха • Дефект соединителя датчика температуры входящего воздуха
• Дефект датчика температуры входящего воздуха
• Неисправность PCB управления внутреннего блока
E8 Защита от перегрузки в режиме обогрева • Загрязнение воздушного фильтра
• Неисправность термодатчика на теплообменнике внутреннего блока (короткое замыкание)
• Неисправность  PCB внутреннего блока 
E9 Неисправность дренажа  • Неисправность дренажной помпы, повреждение кабеля, отключен разъем, забита дренажная труба
• Неправильная работа поплавкового реле
• Неисправность  PCB внутреннего блока 
E10 Превышение числа внутренних блоков (более 16), контролируемых с одного пульта управления  
E11 Неверное подключение адресации между master и slave блоками • Для RC-EX1: «Меню» — «Настройка внутренних блоков» — «Выбор В/Б»
E12 В одной сети SL смешаны автоматическая адресация (с пульта управления) и ручная адресация.  
E14 Ошибка связи между между master и slave блоками  • Не указан Master-блок
• Неверное подключение кабеля ПДУ, повреждение кабеля ПДУ между master и slave блоками
E16 Неисправность двигателя вентилятора внутреннего блока  • Неисправность электродвигателя
• Неисправность PCB внутреннего блока (в случае блоков FDTC и FDT проверить предохранитель F202).
E18 Неверное подключение адресации между master и slave блоками  • Не задан номер ведущего внутреннего блока.                           
• Адрес ведомого внутреннего блока совпадает с адресом ведущего внутреннего блока.                                                                 
• Нет питания на master-блоке
E19 Ошибка помпы из-за неотключения SW7-1 после проверки работоспособности внутреннего блока   
E20 Завышенная скорость вентилятора внутреннего блока   
E21 Не защёлкнута панель фильтра внутреннего блока (только FDT)   
E22 Ошибка подключения к наружному блоку  Внутренние блоки 1,5kW возможно подключить к наружным блокам KX6:     
• FDC224-335KXE6 c кодом A и выше
• FDC400-1360KXE6 c кодом F и выше
E28 Неисправность термодатчика проводного ПДУ  Через 10 секунд после выключения датчика пульта управления, E28 не будет отображаться, даже если провод датчика отсоединен. В это время происходит переключение от датчика пульта управления к датчику температуры входящего воздуха внутреннего блока.
E30 Отсутствие соединения внутреннего и внешнего блоков  • Неисправность PCB управления внутреннего блока
• Неисправность PCB управления внешнего блока
E31 Двойной адрес внешнего блока  • Ошибка адресации внешних блоков
• Подключено более 128 внутренних блоков
• Не установлен переключатель master/slave для комбинированных наружных блоков
* Адресация не будет подтверждена, если не перезагрузить питание.
**В случае комбинирования блоков установите одинаковые адреса для главного и подчиненного блоков. Главные и подчиненные блоки можно назначить с помощью SW4-7.
E32 Открытая L3 фаза электропитания на первичной стороне Когда напряжение между L1-N и L2-N равно 0 V, и/или ток L3 уменьшается (0 ампер).
E36 Повышенная температура  трубы нагнетания (Tho-D1)  • Неисправность температурного датчика выпускной трубы
• Неисправность датчика высокого давления
• Недостаточное количество хладагента
• Неисправность EEV внутреннего блока
• Неисправность температурного датчика теплообменника
внутреннего блока
• Неисправность EEVH внешнего блока
• Неисправность датчика температуры трубы всасывания или неисправность датчика низкого давления
• Неисправность EEVSC внешнего блока
• Неисправность температурного датчика Tho-H
E37 Неисправен датчик теплообменника наружного блока  Красный LED-индикатор дополнительно указывает на проблемный термистор:
• Tho-R1: мигает 1 раз (E37-1)
• Tho-R2: мигает 2 раза (E37-2)
• Tho-R3: мигает 3 раза (E37-3)
• Tho-R4: мигает 4 раза (E37-4)
• Tho-SC: мигает 5 раз (E37-5)
• Tho-H: мигает 6 раз (E37-6) 
E38  Неисправен датчик наружной температуры • Неисправность PCB управления наружного блока
• Разрыв жгута проводов термистора или секции температурного датчика
• Разрыв проводного соединения (разъема)
E39  Неисправен датчик температуры трубы нагнетания • Неисправность PCB управления наружного блока
• Разрыв жгута проводов термистора или секции температурного датчика
• Разрыв проводного соединения (разъема)
E40 Ошибка высокого давления (активирован 63Н1)   • Короткое замыкание в цепи воздушного потока, сбой воздушного потока, загрязнение наружного теплообменника/неисправность мотора вентилятора
• Неисправность PCB управления наружного блока
• Неисправность разъема 63H1
• Неисправность разъема электронного клапана
• Закрыт сервисный порт
• Смесь неконденсируемого газа (азота и т.д.)
E41 Перегрев силового транзистора   • Неисправность инверторной PCB
• Неисправность мотора наружного вентилятора
• Неправильно закреплено ребро радиатора силового транзистора
• Неисправность температурного термистора силового транзистора
• Недостаточное пространство установки для наружного блока
E42 Токовая отсечка • Закрыты порты
• Неисправность подачи питания
• Избыточное количество хладагента
• Неисправность компрессора
• Неисправность модуля силового транзистора 
E43 Превышение числа подключенных внутренних блоков, превышение допустимой суммарной мощности • Ошибка адресации внутреннего/внешнего блока
• Ошибка соединения сигнальных проводов
E44 Влажный ход • Несоответствие трубопроводов и сигнальной линии
• Перезаправка хладагента
• Циркуляция хладагента через байпасный клапан
• Ошибка контроля перегрева хладагента
E45 Ошибка связи инвертора • Неисправность PCB инвертора
• Неисправность разъема между PCB управления наружного блока и PCB инвертора
• Неисправность PCB управления наружного блока
E46 Смешивание ручной и автоматической адресации в одной сети SL   
E47 Ошибка перегрузки инвертора по току  • Неисправность PCB управления наружного блока
• Пыль на PCB управления
• Перегорел предохранитель F2
E48 Неисправность двигателя вентилятора внешнего блока  • Неисправность PCB управления внешнего блока
• Попадание посторонних предметов в область вращения вентилятора
• Неисправность мотора вентилятора
E49 Ошибка низкого давления или неисправность датчика низкого давления • Датчик низкого давления (дефект PSL)
• Рабочий клапан закрыт
• EEV закрыт (неправильная работа)
• Недостаточный объем хладагента
• Засорение (EEV, фильтр)
E51 Перегрев силового транзистора в течение 15 минут • Неисправность силового транзистора
• Неисправность инвертора и мотора вентилятора
E53 Неисправность датчика температуры трубы всасывания   • Отсоединение провода термистора или внутреннего провода считывающей части (проверьте запрессованную часть)
• Отсоединение разъема термистора
• Дефект PCB управления внешнего блока
E54 Неисправность датчика высокого давления/ датчика низкого давления Красный LED-индикатор дополнительно указывает на проблемный термистор:
• E54-1/мигает 1 раз: аномалия датчика низкого давления
• E54-2/мигает 2 раза: аномалия датчика высокого давления
E55 Неисправность датчика температуры компрессора  (Tho-C1) • Отсоединение провода термистора или внутреннего провода считывающей части (проверьте запрессованную часть)
• Отсоединение разъема термистора
• Дефект PCB управления внешнего блока
E56 Перегрев силивого модуля (IGBT) (Tho-P1, Tho-P2) Красный LED-индикатор дополнительно указывает на проблемный термистор:
• E56-1/мигает 1 раз: аномалия Tho-P1
• E56-2/мигает 2 раза: аномалия Tho-P2
E57   • Недостаток хладагента
• Закрыт клапан
E58 Аварийное прекращение подачи тока • Избыточное количество хладагента
• Не соблюдено пространство установки внутреннего, наружного блоков
• Неисправность компрессора
• Неисправность датчика температуры наружного воздуха
• Неисправность PCB управления наружного блока
E59 Ошибка запуска компрессора  • Неисправность мотора наружного вентилятора
• Неисправность PCB инвертора
• Ненормальное напряжение питания
• Ненадлежащее количество хладагента и неисправность холодильного контура
• Неисправный компрессор (подшипник мотора)
E60 Ошибка определения положения ротора компрессора (рассинхронизация) • Неисправность мотора наружного вентилятора
• Неисправность PCB управления наружного блока
• Неисправность PCB инвертора
• Ненормальное напряжение питания
• Ненадлежащее количество хладагента и неисправность холодильного контура
• Неисправность компрессора (мотор, подшипник)
E61 Ошибка связи между master / slave наружными блоками   
E63 Аварийная остановка  
E75 Ошибка связи при работе с центральным пультом   
E82 Неисправен датчик теплообменника внутреннего блока • Неисправен термодатчик (дефект чувствительного элемента, повреждение кабеля, короткое замыкание)
• Отсоединение разъема термодатчика
E84 Высокая влажность  
E85 Защита от обмерзания • Упала скорость вентилятора внутреннего блока
• Неисправность датчика теплообменника внутреннего блока
E86 Высокое давление в режиме обогрева • Перегрузка системы
• Упала скорость вентилятора внутреннего блока
• Неисправность датчика теплообменника внутреннего блока

E1-сбой печатной платы внутреннего блока, неправильно подключён пульт дистанционного управления или неисправен.

E2 -дублирование адресов внутренних блоков

E3 — некорректный адрес наружного блока

E5 -неисправна плата управления наружного блока

E6 — термодатчик испарителя замкнут/оборван

E7 —сенсор внутреннего блока замкнут/оборван

E8 — перегрузка испарителя или неисправен датчик

E9 — ошибка дренажного насоса или поплавкового датчика

E10 —больше 16 внутренних блоков соединяются с пультом управления

E11 -больше одного блока соединяются с пультом управления,когда адрес занят

E12 -ошибка настройки адресов

E14 -неправильные настройки соединения master-slave (ведущий-ведомый)

E16 -неисправен вентилятор внутреннего блока

E28 -неисправен датчик пульта управления

E30 —ошибка соединения наружного/внутреннего блоков

E31 -дублирование, неправильные настройки адресов

E32 — неправильная последовательность фаз или обрыв провода

E33 — обрыв обмотки компрессора

E34 — разомкнута фаза L3 обмотки 52C

E35 —высокая температура конденсера или неисправен термодатчик

E36 —недопустимое отклонение температуры выходного воздуха

E37 -неисправен термодатчик конденсера

E38 — неисправен термодатчик наружного воздуха

E39 — неисправен термодтчик нагнетательной трубы

E40 — сработала реле высокого давления 63Н1

E49 -система остановилась, низкое давление или недостаточно хладагента

E52 — сбой в 52С

E53 —неисправен термистор всасывающей трубы

E54 -отсоединён датчик низкого давления

E55 — неисправен термистор температуры внутреннего пространства компрессора

E56 -термодатчик силового транзистора неисправен или оборван

E57-недостаточно хладагента

E59 -не запускается компрессор

E60 -ошибка позиционирования компрессора

E63 -аварийное отключение внутреннего блока

Полная версия кодов ошибок в формате .pdf

Скачать

Коды ошибок для моделей

FDTA28KXE4 FDTWA28KXE4 FDTQA22KXE4

FDRA22KXE4 FDQMA22KXE4/28/36/45/56/71/90/112/140

FDTSA22KXE4

FDUMA36KXE4 FDURA45KXE4 FDEA36KXE4

FDKA22KXE4 FDFLA28KXE4

FDE321HKXE2 401HKXE2 501/631/801/1001/1251HKXE2

FDKY251HKXE2,321HKXE2,401HKXE2,501HKEXE2,631HKXE2

FDFL251HKXE2,401HKXE2,631HKXE2

FDFUA28KXE4 SRK20ZD-S SRK501CENF-L

SRK561CENF-F SCM328CENF-L1 SCM338CENF-L1

SRK25GZ-L1/35/502Z-L

FDC508HES3 808HES3 1008HES3

FDT208-A 258A 308A 408-A 508-A

FDR208-A 258A 308A 408-A 508-A

SCM60ZD-S SCM80ZD-S

SKM2ZD-S SKM25ZD-S

SKM28ZD-S SKM35ZD-S

FDC2001HKXRE2,2501HKXRE2

и др.

Коды ошибок марки кондиционеров Mitsubishi Heavy для моделей;

  1. FDTA28KXE4
  2. FDTWA28KXE4
  3. FDTQA22KXE4
  4. FDRA22KXE4
  5. FDQMA22KXE4/28/36/45/56/71/90/112/140
  6. FDTSA22KXE4
  7. FDUMA36KXE4
  8. FDURA45KXE4
  9. FDEA36KXE4
  10. FDKA22KXE4
  11. FDFLA28KXE4
  12. FDE321HKXE2
  13. 401HKXE2 501/631/801/1001/1251HKXE2
  14. 631HKXE2
  15. 501HKEXE2
  16. FDFL251HKXE2
  17. FDFUA28KXE4
  18. SRK20ZD-S
  19. SRK501CENF-L
  20. SRK561CENF-F
  21. SCM328CENF-L1
  22. SCM338CENF-L1
  23. SRK25GZ-L1/35/502Z-L
  24. FDC508HES3
  25. 808HES3
  26. 1008HES3
  27. FDT208-A 258A 308A 408-A 508-A
  28. FDR208-A 258A 308A 408-A 508-A
  29. SCM60ZD-S
  30. SCM80ZD-S
  31. SKM25ZD-S
  32. SKM2ZD-S
  33. SKM28ZD-S
  34. SKM35ZD-S
  35. FDC2001HKXRE2
  36. 2501HKXRE2
  37. и др.
Ошибка Неисправность
E1 Сбой печатной платы внутреннего блока, неправильно подключён пульт дистанционного управления или неисправен
E2 Дублирование адресов внутренних блоков
E3 Некорректный адрес наружного блока
E5 Неисправна плата управления наружного блока
E6 Термодатчик испарителя замкнут/оборван
E7 Сенсор внутреннего блока замкнут/оборван
E8 Перегрузка испарителя или неисправен датчик
E9 Ошибка дренажного насоса или поплавкового датчика
E10 Больше 16 внутренних блоков соединяются с пультом управления
E11 Больше одного блока соединяются с пультом управления,когда адрес занят
E12 Ошибка настройки адресов
E14 Неправильные настройки соединения master-slave (ведущий-ведомый)
E16 Неисправен вентилятор внутреннего блока
E28 Неисправен датчик пульта управления
E30 Ошибка соединения наружного/внутреннего блоков
E31 Дублирование, неправильные настройки адресов
E32 Неправильная последовательность фаз или обрыв провода
E33 Обрыв обмотки компрессора
E34 Разомкнута фаза L3 обмотки 52C
E35 Высокая температура конденсера или неисправен термодатчик
E36 Недопустимое отклонение температуры выходного воздуха
E37 Неисправен термодатчик конденсера
E38 Неисправен термодатчик наружного воздуха
E39 Неисправен термодтчик нагнетательной трубы
E40 Сработала реле высокого давления 63Н1
E49 Система остановилась, низкое давление или недостаточно хладагента
E52 Сбой в 52С
E53 Неисправен термистор всасывающей трубы
E54 Отсоединён датчик низкого давления
E55 Неисправен термистор температуры внутреннего пространства компрессора
E56 Термодатчик силового транзистора неисправен или оборван
E57 Недостаточно хладагента
E59 Не запускается компрессор
E60 Ошибка позиционирования компрессора
E63 Аварийное отключение внутреннего блока

Ремонт кондиционеров

Black = All R410A

Red = FD Split 1, 2 Series R410A

Blue = KX4 & KXR4 Series R410A

Код ошибки Внутренняя плата Наружная плата Подробная информация о неисправности
Красный светодиод Зеленый светодиод Красный светодиод Зеленый светодиод
Нет признаков Не горит Мигание Не горит Мигание • Нормальная работа
Не горит Не горит Не горит Не горит • Нет электросети [выключеное питание или отказ источника питания].
• L фазный провод разомкнут
Мигает 3 раза Мигание Не горит Мигание • Провода пульта дистанционного управления — X & Y перепутаны.
• Провода пульта дистанционного управления — Y & Z перепутаны.
• Проводка пульта дистанционного управления является разомкнутой. (X провод сломан — звуковой сигнал вырабатывается и указание. Z сломанный провод — нет звукового сигнала и нет индикации)
LCD мигает непрерывно потихоньку или выкл. Не горит Мигание Мигает 2 раза Мигание • Открытая цепь или плохая внутренняя / наружная соединительная проводка
E1 Не горит Выкл. Или Вкл. Непрерывно Не горит Мигание • Внутренняя плата или отказ CPU
Выкл. Или Вкл. Непрерывно Выкл. Или Вкл. Непрерывно Не горит Мигание • Внутренняя плата или отказ CPU
Не горит Мигание Не горит Мигание • В контрольной группе электроснабжения, подача питания по меньшей мере на один внутренний блок выключена
• Провод дистанционного управления Y разомкнут
• Проводки X и Y пульта дистанционного управления поменять местами
• Неисправная плата внутреннего или удаленного пульта
• Электрические помехи
Не горит Мигание Не горит Мигание • Проводка пульта дистанционного управления, подключенна к A и B
• Проводка A и B соединена в замкнутом контуре
• Процессор внутреннего блока печатной платы отсутствует
Мигает 3 раза Мигание Не горит Мигание • Разомкнутая цепь подключения пульта дистанционного управления
E2 Мигает один раз Мигание Не горит Мигание • Дублирование адресов внутренних блоков.
• В сеть подключено более 49 внутренних блоков
E3 Мигает 2 раза Мигание Не горит Не горит • Нет сетевого питания на наружном блоке [выключение питания или сбой питания]
Мигает 2 раза Не горит Не горит Мигает 2 раза • Неправильная настройка адреса наружного блока
Мигает 2 раза Мигание Выкл. Или Вкл. Непрерывно Неопределен • Нет сетевого питания на наружном блоке [выключение питания или сбой питания]
E5 Мигает 2 раза Мигание Мигает 2 раза Мигание • Ошибка связи с наружнем/внутренним блоком
Мигает 2 раза Мигание Не горит Не горит • Нарушение работы ППБ блока управления наружным блоком
• Неисправен инвертор
Мигает 2 раза Мигание Не горит Не горит • Отказ внешнего блока питания (где внутренние / наружные источники питания разделены)
• Ошибка внутренней / наружной связи
• Поменяйте местами проводку А и Б затем включите
Мигает 2 раза Мигание Не горит Не регулярное мигание Отказ микрокомпьютера наружного блока
E6 Мигает один раз Мигание Не горит Мигание • Неисправен датчик теплообменника внутреннего блока [THIR] (сопротивление разомкнутая цепь или замкнутая цепь)
• Плохое соединение разъема датчика в помещении ПЕЧАТНАЯ ПЛАТА
E7 Мигает один раз Мигание Не горит Мигание • Неисправен датчик возврата внутреннего блока [Thia] (сопротивление разомкнуто или замкнуто)
• Плохое соединение разъема датчика в помещении ПЕЧАТНАЯ ПЛАТА
E8 Мигает один раз Мигание Не горит Мигание • Перегрузка при нагревании (необычайно высокая температура в помещении температура теплообменника).
• Отказ датчика теплообменника внутреннего блока [THIR] (сопротивление датчика замкнутая цепь).
E9 Мигает один раз Мигание Не горит Мигание • Ошибка дренажного насоса или поплавкового датчика.
• Обнаружен конденсат в сливном лотке.
E10 Не горит Мигание Не горит Мигание • 17 или более внутренних блоков, подключенные к одному пульту дистанционного управления (максимально допустимо: 16)
E11 Не горит Мигание Не горит Мигание • Больше одного блока соединяются с пультом управления,когда адрес занят

Ошибки Mitsubishi Heavy бытовых серий

Run Timer Ошибка кондиционера Митсубиси
1-кратное мигание Постоянно светится E6
2-кратное мигание Постоянно светится  E7
3-кратное мигание  Постоянно светится E6
4-кратное мигание  Постоянно светится E9
5-кратное мигание  Постоянно светится E47
6-кратное мигание  Постоянно светится E16
7-кратное мигание  Постоянно светится E57
Постоянно мигает  1-кратное мигание  E38
Постоянно мигает  2-кратное мигание E37
Постоянно мигает 4-кратное мигание  E39
Постоянно светится 1-кратное мигание E42
Постоянно светится 2-кратное мигание E59
Постоянно светится 3-кратное мигание E58
Постоянно светится 4-кратное мигание E51
Постоянно светится 5-кратное мигание E36
Постоянно светится 6-кратное мигание E5
Постоянно светится 7-кратное мигание E48
Постоянно светится  Постоянно мигает E35
2-кратное мигание 2-кратное мигание E60
Не светится 5-кратное мигание E5
3-кратное мигание 5-кратное мигание E35
3-кратное мигание 6-кратное мигание E36
3-кратное мигание 7-кратное мигание E37
3-кратное мигание 8-кратное мигание E38
3-кратное мигание 9-кратное мигание E39
4-кратное мигание 2-кратное мигание E42
4-кратное мигание 7-кратное мигание E47
4-кратное мигание 8-кратное мигание E48
5-кратное мигание 1-кратное мигание E51
5-кратное мигание 3-кратное мигание E53
5-кратное мигание 7-кратное мигание E57
5-кратное мигание 8-кратное мигание E58
5-кратное мигание 9-кратное мигание E59
6-кратное мигание Не светится E60
6-кратное мигание 1-кратное мигание E61
6-кратное мигание 2-кратное мигание E62
7-кратное мигание  1-кратное мигание  E40
8-кратное мигание Не светится E80
8-кратное мигание 2-кратное мигание E82
8-кратное мигание 4-кратное мигание E84
8-кратное мигание 5-кратное мигание E85
8-кратное мигание 6-кратное мигание E86

В полупромышленном и мультизональном оборудовании коды ошибки Mitsubishi Heavy с E1 до E31 относятся к внутренним блокам и высвечиваются только на пульте проблемного блока. Коды ошибок Митсубиси Хеви с номерами E32 — E75 относятся к наружным блокам и показываются на всех проводных пультах данного фреонового контура.

Кондиционеры Mitsubishi Heavy ошибки

Коды ошибок Mitsubishi Описание ошибок Митсубиси Возможные причины ошибки Митсубиси Хеви
E1 Ошибка соединения пульта управления • Плохой контакт или обрыв сигнального провода 
• Электромагнитные наводки на кабель
• Неисправность  PCB внутреннего блока или пульта ДУ
E2 Двойной адрес внутреннего блока • Количество подключенных блоков превышает лимит.
• Двойной адрес внутреннего блока.
• Дефект PCB управления внутреннего блока.
E3 Ошибка сигнальной линии Возникает при полном отсутствии связи между всеми внутренними и внешними блоками. Если появляется соединение между внутренними и внешними блоками, ошибка меняется на E5. В обоих случаях проверьте предохранители и провода сигнальной линии. Проверить заданный номер наружного блока.
E5 Ошибка межблочной связи Если соединение между внутренним и внешним блоками отсутствует более 2 минут.
• Сбой питания внешнего блока
• Смена полярности А и B после подачи питания.
E6 Неисправен датчик 1 (2) теплообменника внутреннего блока • Дефект соединителя датчика теплообменника внутреннего блока
• Дефект датчика теплообменника внутреннего блока
• Неисправность PCB управления внутреннего блока
E7 Неисправен датчик температуры комнатного воздуха • Дефект соединителя датчика температуры входящего воздуха
• Дефект датчика температуры входящего воздуха
• Неисправность PCB управления внутреннего блока
E8 Защита от перегрузки в режиме обогрева • Загрязнение воздушного фильтра
• Неисправность термодатчика на теплообменнике внутреннего блока (короткое замыкание)
• Неисправность  PCB внутреннего блока 
E9 Неисправность дренажа  • Неисправность дренажной помпы, повреждение кабеля, отключен разъем, забита дренажная труба
• Неправильная работа поплавкового реле
• Неисправность  PCB внутреннего блока 
E10 Превышение числа внутренних блоков (более 16), контролируемых с одного пульта управления  
E11 Неверное подключение адресации между master и slave блоками • Для RC-EX1: «Меню» — «Настройка внутренних блоков» — «Выбор В/Б»
E12 В одной сети SL смешаны автоматическая адресация (с пульта управления) и ручная адресация.  
E14 Ошибка связи между между master и slave блоками  • Не указан Master-блок
• Неверное подключение кабеля ПДУ, повреждение кабеля ПДУ между master и slave блоками
E16 Неисправность двигателя вентилятора внутреннего блока  • Неисправность электродвигателя
• Неисправность PCB внутреннего блока (в случае блоков FDTC и FDT проверить предохранитель F202).
E18 Неверное подключение адресации между master и slave блоками  • Не задан номер ведущего внутреннего блока.                           
• Адрес ведомого внутреннего блока совпадает с адресом ведущего внутреннего блока.                                                                 
• Нет питания на master-блоке
E19 Ошибка помпы из-за неотключения SW7-1 после проверки работоспособности внутреннего блока   
E20 Завышенная скорость вентилятора внутреннего блока   
E21 Не защёлкнута панель фильтра внутреннего блока (только FDT)   
E22 Ошибка подключения к наружному блоку  Внутренние блоки 1,5kW возможно подключить к наружным блокам KX6:     
• FDC224-335KXE6 c кодом A и выше
• FDC400-1360KXE6 c кодом F и выше
E28 Неисправность термодатчика проводного ПДУ  Через 10 секунд после выключения датчика пульта управления, E28 не будет отображаться, даже если провод датчика отсоединен. В это время происходит переключение от датчика пульта управления к датчику температуры входящего воздуха внутреннего блока.
E30 Отсутствие соединения внутреннего и внешнего блоков  • Неисправность PCB управления внутреннего блока
• Неисправность PCB управления внешнего блока
E31 Двойной адрес внешнего блока  • Ошибка адресации внешних блоков
• Подключено более 128 внутренних блоков
• Не установлен переключатель master/slave для комбинированных наружных блоков
* Адресация не будет подтверждена, если не перезагрузить питание.
**В случае комбинирования блоков установите одинаковые адреса для главного и подчиненного блоков. Главные и подчиненные блоки можно назначить с помощью SW4-7.
E32 Открытая L3 фаза электропитания на первичной стороне Когда напряжение между L1-N и L2-N равно 0 V, и/или ток L3 уменьшается (0 ампер).
E36 Повышенная температура  трубы нагнетания (Tho-D1)  • Неисправность температурного датчика выпускной трубы
• Неисправность датчика высокого давления
• Недостаточное количество хладагента
• Неисправность EEV внутреннего блока
• Неисправность температурного датчика теплообменника
внутреннего блока
• Неисправность EEVH внешнего блока
• Неисправность датчика температуры трубы всасывания или неисправность датчика низкого давления
• Неисправность EEVSC внешнего блока
• Неисправность температурного датчика Tho-H
E37 Неисправен датчик теплообменника наружного блока  Красный LED-индикатор дополнительно указывает на проблемный термистор:
• Tho-R1: мигает 1 раз (E37-1)
• Tho-R2: мигает 2 раза (E37-2)
• Tho-R3: мигает 3 раза (E37-3)
• Tho-R4: мигает 4 раза (E37-4)
• Tho-SC: мигает 5 раз (E37-5)
• Tho-H: мигает 6 раз (E37-6) 
E38  Неисправен датчик наружной температуры • Неисправность PCB управления наружного блока
• Разрыв жгута проводов термистора или секции температурного датчика
• Разрыв проводного соединения (разъема)
E39  Неисправен датчик температуры трубы нагнетания • Неисправность PCB управления наружного блока
• Разрыв жгута проводов термистора или секции температурного датчика
• Разрыв проводного соединения (разъема)
E40 Ошибка высокого давления (активирован 63Н1)   • Короткое замыкание в цепи воздушного потока, сбой воздушного потока, загрязнение наружного теплообменника/неисправность мотора вентилятора
• Неисправность PCB управления наружного блока
• Неисправность разъема 63H1
• Неисправность разъема электронного клапана
• Закрыт сервисный порт
• Смесь неконденсируемого газа (азота и т.д.)
E41 Перегрев силового транзистора   • Неисправность инверторной PCB
• Неисправность мотора наружного вентилятора
• Неправильно закреплено ребро радиатора силового транзистора
• Неисправность температурного термистора силового транзистора
• Недостаточное пространство установки для наружного блока
E42 Токовая отсечка • Закрыты порты
• Неисправность подачи питания
• Избыточное количество хладагента
• Неисправность компрессора
• Неисправность модуля силового транзистора 
E43 Превышение числа подключенных внутренних блоков, превышение допустимой суммарной мощности • Ошибка адресации внутреннего/внешнего блока
• Ошибка соединения сигнальных проводов
E44 Влажный ход • Несоответствие трубопроводов и сигнальной линии
• Перезаправка хладагента
• Циркуляция хладагента через байпасный клапан
• Ошибка контроля перегрева хладагента
E45 Ошибка связи инвертора • Неисправность PCB инвертора
• Неисправность разъема между PCB управления наружного блока и PCB инвертора
• Неисправность PCB управления наружного блока
E46 Смешивание ручной и автоматической адресации в одной сети SL   
E47 Ошибка перегрузки инвертора по току  • Неисправность PCB управления наружного блока
• Пыль на PCB управления
• Перегорел предохранитель F2
E48 Неисправность двигателя вентилятора внешнего блока  • Неисправность PCB управления внешнего блока
• Попадание посторонних предметов в область вращения вентилятора
• Неисправность мотора вентилятора
E49 Ошибка низкого давления или неисправность датчика низкого давления • Датчик низкого давления (дефект PSL)
• Рабочий клапан закрыт
• EEV закрыт (неправильная работа)
• Недостаточный объем хладагента
• Засорение (EEV, фильтр)
E51 Перегрев силового транзистора в течение 15 минут • Неисправность силового транзистора 
• Неисправность инвертора и мотора вентилятора
E53 Неисправность датчика температуры трубы всасывания   • Отсоединение провода термистора или внутреннего провода считывающей части (проверьте запрессованную часть)
• Отсоединение разъема термистора
• Дефект PCB управления внешнего блока
E54 Неисправность датчика высокого давления/ датчика низкого давления Красный LED-индикатор дополнительно указывает на проблемный термистор:
• E54-1/мигает 1 раз: аномалия датчика низкого давления
• E54-2/мигает 2 раза: аномалия датчика высокого давления
E55 Неисправность датчика температуры компрессора  (Tho-C1) • Отсоединение провода термистора или внутреннего провода считывающей части (проверьте запрессованную часть)
• Отсоединение разъема термистора
• Дефект PCB управления внешнего блока
E56 Перегрев силивого модуля (IGBT) (Tho-P1, Tho-P2) Красный LED-индикатор дополнительно указывает на проблемный термистор:
• E56-1/мигает 1 раз: аномалия Tho-P1
• E56-2/мигает 2 раза: аномалия Tho-P2
E57   • Недостаток хладагента
• Закрыт клапан
E58 Аварийное прекращение подачи тока • Избыточное количество хладагента
• Не соблюдено пространство установки внутреннего, наружного блоков
• Неисправность компрессора
• Неисправность датчика температуры наружного воздуха
• Неисправность PCB управления наружного блока
E59 Ошибка запуска компрессора  • Неисправность мотора наружного вентилятора
• Неисправность PCB инвертора
• Ненормальное напряжение питания
• Ненадлежащее количество хладагента и неисправность холодильного контура
• Неисправный компрессор (подшипник мотора)
E60 Ошибка определения положения ротора компрессора (рассинхронизация) • Неисправность мотора наружного вентилятора
• Неисправность PCB управления наружного блока
• Неисправность PCB инвертора
• Ненормальное напряжение питания
• Ненадлежащее количество хладагента и неисправность холодильного контура
• Неисправность компрессора (мотор, подшипник)
E61 Ошибка связи между master / slave наружными блоками   
E63 Аварийная остановка  
E75 Ошибка связи при работе с центральным пультом   
E82 Неисправен датчик теплообменника внутреннего блока • Неисправен термодатчик (дефект чувствительного элемента, повреждение кабеля, короткое замыкание)
• Отсоединение разъема термодатчика
E84 Высокая влажность  
E85 Защита от обмерзания • Упала скорость вентилятора внутреннего блока
• Неисправность датчика теплообменника внутреннего блока
E86 Высокое давление в режиме обогрева • Перегрузка системы
• Упала скорость вентилятора внутреннего блока
• Неисправность датчика теплообменника внутреннего блока

Коды ошибок кондиционеров Mitsubishi Heavy

Коды ошибок кондиционеров Mitsubishi Heavy

E1-сбой печатной платы внутреннего блока, неправильно подключён пульт дистанционного управления или неисправен.

E2 -дублирование адресов внутренних блоков

E3 — некорректный адрес наружного блока

E5 -неисправна плата управления наружного блока

E6 — термодатчик испарителя замкнут/оборван

E7 -сенсор внутреннего блока замкнут/оборван

E8 — перегрузка испарителя или неисправен датчик

E9 — ошибка дренажного насоса или поплавкового датчика

E10 -больше 16 внутренних блоков соединяются с пультом управления

E11 -больше одного блока соединяются с пультом управления,когда адрес занят

E12 -ошибка настройки адресов

E14 -неправильные настройки соединения master-slave (ведущий-ведомый)

E16 -неисправен вентилятор внутреннего блока

E28 -неисправен датчик пульта управления

E30 -ошибка соединения наружного/внутреннего блоков

E31 -дублирование, неправильные настройки адресов

E32 — неправильная последовательность фаз или обрыв провода

E33 — обрыв обмотки компрессора

E34 — разомкнута фаза L3 обмотки 52C

E35 -высокая температура конденсера или неисправен термодатчик

E36 -недопустимое отклонение температуры выходного воздуха

E37 -неисправен термодатчик конденсера

E38 — неисправен термодатчик наружного воздуха

E39 — неисправен термодтчик нагнетательной трубы

E40 — сработала реле высокого давления 63Н1

E49 -система остановилась, низкое давление или недостаточно хладагента

E52 — сбой в 52С

E53 -неисправен термистор всасывающей трубы

E54 -отсоединён датчик низкого давления

E55 — неисправен термистор температуры внутреннего пространства компрессора

E56 -термодатчик силового транзистора неисправен или оборван

E57-недостаточно хладагента

E59 -не запускается компрессор

E60 -ошибка позиционирования компрессора

E63 -аварийное отключение внутреннего блока

Коды ошибок кондиционеров Mitsubishi Electric

Коды ошибок кондиционеров Mitsubishi Electric

Таблица расшифровки кодов ошибок

Error

Расшифровка Русский перевод
P1 Intake sensor error Ошибка датчика на входе
P2 Pipe (TH5) sensor error Ошибка датчика теплообменника ТН5 (по схеме)
P4 Drain sensor error/Float switch connector (CN4F) open Переполнение дренажного поддона, или обрыв поплавкового датчика CN4F
P5 Drain pump error Ошибка дренажной помпы
P6 Freezing/Overheating protection operation Ошибка по обмерзанию или перегреву
P8 Pipe temperature error
P9 Pipe (TH2) sensor error Ошибка по датчику теплообменника ТН2
PA Forced compressor stop(due to water leakage abnormality) Принудительная остановка компрессора (из-за переполнения дренажной системы)
E0, E3 Remote controller transmission error Нет связи с пультом управления
E1, E2 Remote controller control board error Неисправна плата пульта управления
E4, E5 Remote controller signal receiving error
E9 Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) Нет связи между внутренним и внешним блоком (Ошибка на внешнем блоке)
EE Communication error between indoor and outdoor units Отсутствует межблочная связь между внутренним и внешним блоками
U1,Ud Abnormal high pressure (63H worked)/Overheating protection operationс Высокое давление по датчику 63Н, или защита от перегрева
U2 Abnormal high discharging temperature/49C worked/insufficient refrigerant Сработал датчик 49С, очень низкое давление нагнетания, недостаток хладагента
U3, U4 Open/short of outdoor unit thermistors Обрыв, короткое замыкание термодатчика внешнего блока
U5 Abnormal temperature of heat sink Температура конденсатора не соответствует норме
U6 Compressor overcurrent interruption/Abnormal of power module Компрессор принудительно остановлен по токовой перегрузке, неисправен силвой модуль
U7 Abnormality of super heat due to low discharge temperatureAbnormal high discharging temperature/49C worked/insufficient refrigerant Сработал датчик 49С / очень низкое давление нагнетания / недостаток хладагента
U8 Outdoor unit fan protection stop Двигатель вентилятора внешнего блока остановлен
U9, UH Abnormality such as overvoltage or voltage shortage and abnormal synchronous signal to main circuit/Current sensor error Повышенное / пониженное напряжение питания, неисправность токового датчика
UF Compressor overcurrent interruption (When compressor locked) Компрессор остановлен из-за токовой перегрузки, компрессор заклинило
UP Compressor overcurrent interruption Остановка компрессора из-за перегрузки по току
Fb Indoor unit control system error (memory error, etc.) Ошибка платы управления внутреннего блока (EEPROM и т.д.)

Коды ошибок бытовых кондиционеров

Определить ошибку в бытовых сплит системах можно по миганию индикаторов на панели внутреннего блока.

Японская компания Mitsubishi Electric, основными направлениями деятельности которой является производство электрических систем, оборудования для жилых домов, систем индустриальной автоматики, электронных устройств, а и также информационных и коммуникационных систем, была основана в 1921 году. Отделившись от фирмы по производству электромоторов для океанских судов, она за несколько десятилетий вышла за рамки Японии.В 1980 году изделия компании, изготовленные с применением передовых технологий, завоевали рынки Европы, Америки, Азии, Африки и Австралии. 

Сегодня корпорация «Мицубиси Электрик» — это офисы и заводы, расположенные в 35 странах мира, около 110 тысяч высокопрофессиональных сотрудников и годовой оборот более чем в 36 млрд. долларов. 

Одними из самых известных продуктов компании «Мицубиши» являются различные модели кондиционеров, отличающиеся высочайшим качеством и использованием уникальных технологий изготовления. Тройной контроль за характеристиками продуктов (на этапе поступления комплектующих, на этапе сборки и после снятия с конвейера) позволяет устройствам работать даже в самых жестких условиях эксплуатации. 

Одной из самых популярных серий настенных кондиционеров является MSZ-GC/GB/GA, отличающаяся низким уровнем шума и высоким КПД. Эти кондиционеры укомплектованы полноразмерным антиоксидантным воздушным фильтром, срок службы которого составляет 9–10 лет, и антиаллергенной фильтрующей вставкой. Развитая система самодиагностики самостоятельно устраняет мелкие недочеты в работе устройства. Инвертор снижает расход электроэнергии и повышает срок службы аппарата. Огромное количество встроенных и внешних систем управления упрощает настраивание необходимых функций. 

Настенные кондиционеры инверторные серии MSZ-GE (MSZ-GE25VA и др.) — это устройства с небывало низким уровнем шума. Это самый тихий климатический прибор среди всех продуктов, производимых компанией «Митцубиси». Он оборудован фирменной антиоксиантной и антиаллергенной очисткой воздуха. Высокая энергоэффективность и достаточно низкая цена делают эти устройства привлекательными для широкого круга потребителей. 

С 2011 года поступает в продажу дизайнерская серия настенных кондиционеров MSZ-EF. Они отличаются изысканным арт-дизайном, небольшими размерами и высокой эффективностью. Наличие новейшей разработки — нано-платинового фильтра, сложной системы жалюзей, создающей оптимальную скорость воздушной струи, а также функции «авторестарт» позволяет использовать это климатическое устройство в различных помещениях. 

Элитная серия бытовых кондиционеров MSZ-FD ДЕЛЮКС (MSZ-FD25VA и др.) представляет собой новую серию сплит-систем, отличающихся высокой энергоэффективностью и бесшумной работой. Все модели укомплектованы активным фильтром (двойная плазма — PLASMA DUO) и датчиком I-SEE, который может сканировать помещение для поддержания равномерной температуры. Низкий уровень шума и очень высокий КПД отличают эти кондиционеры Mitsubishi Electric от изделий других производителей. 

Настенные кондиционеры серии MSC-GE-VB/MU-GA-VB предназначены для охлаждения и обогрева небольшого помещения. Эти сплит-системы, включая модели, MSC-GA25VB, MSC-GA20VB, MSC-GE20VB и другие, оборудованы фильтрами с антиоксидантными и антиаллергенными свойствами. Невысокий уровень шума, широкий угол струи воздуха, наличие системы настройки параметров в зависимости от желания потребителя — все эти функции позволяют использовать это устройство, как в квартирах, так и небольших офисах. 

Инверторные кондиционеры напольные серии MFZ-КА используются в помещениях, где невозможна установка настенного климатического устройства. Могут подавать воздух в различных направлениях. Небольшой размер, низкий уровень шума, наличие импульсного блока питания и микросхемы-монитора напряжения помогают исключить «зависание» устройства. Режим экономичного охлаждения «I save» позволяет снизить расход электроэнергии. 

Канальные кондиционеры серии SEZ-KD могут использоваться в помещениях с изысканным дизайном. Наличие тонкого внутреннего блока поможет минимизировать запотолочное пространство (при установке натяжного потолка). Легко встраивается в любые системы воздуховодов. 

Кассетные кондиционеры, а именно четырехпоточные серии SLZ-KA и однопоточные серии MLZ-KA, представляют собой устройства, предназначенные для охлаждения и обогрева помещений различной направленности. Они оборудованы специальными декоративными панелями, через которые осуществляется изменение разнообразных функций. Направление подачи воздуха может быть отрегулировано в зависимости от необходимых требований. 

Все кондиционеры «Мицубиси Электрик», в том числе и мультисистемы серии MXZ-2A/3A/4A/5A-VA и серии MXZ-8A140VA, имеющие в наличии от 2 до 8 внутренних блоков, — это высококачественные изделия, представленные в различных ценовых категориях. Каждое из них обладает рядом функции, позволяющих использовать эти климатические устройства на протяжении десятилетий.

Коды ошибок неисправностей кондиционеров Mitsubishi Heavy Industries приведены в таблице 2, 3, 4.

В целях правильной диагностики перед тем, как предпринять меры по устранению возникшей неисправности, убедитесь в том, что симптомы, подтверждающие возникновение неисправности, проявились повторно.

Нахождение и устранение неисправностей в холодильном контуре

Диагностика состояния работы по рабочему давлению и разнице температур

Точная диагностика требует навыков, которые приобретаются в результате многолетней практики: одна неисправность может повлечь за собой другую, иногда одновременно могут иметь место несколько неисправностей из разных источников. Выявить источники неисправностей легче, если ежедневно наблюдать за рабочим состоянием кондиционера. Полезным признаком является рабочее давление и разность температур между всасываемым и распределяемым воздухом. В таблице 1 приведены некоторые указания.

Информация приведена для полупромышленных кондиционеров СЕРИИ V-MULTI (Сплит-система с тепловым насосом):

(НАРУЖНЫЙ БЛОК) FDCA301HEN 301HES 401HEN 401HES 501HES 601HES 801HES 1001HES

(ВНУТРЕННИЙ БЛОК) FDTA151 201 251 301 401 501, FDENA151 201 251 301 401 501, FDKNA151 201 251 301, FDURA201 251 301 401 501

Продажа и монтаж. Ремонт и обслуживание (Пн.-пт.: 09.00—19.00, сб-вс: 10.00-17.00):

+7(495) 146-65-64

sale@service-climate.ru

Кондиционеры Mitsubishi Heavy отличаются высоким Японским качеством и надежностью. Этот
японский бренд уже давно известен не только в России, но и во многих
странах мира. Компания предлагает кондиционеры для размещения в офисных,
жилых и производственных помещениях. Кондиционеры Mitsubishi Heavy имеют высокий уровень надежности.

Е1 – произошел сбой в печатной плате внутреннего блока или возникли
неисправности в пульте управления;

Е2 – произошло дублирование адресов внутренних блоков;

Е3 – адрес наружного блока является некорректным;

Е5 – возникли неисправности в плате управления наружного бока;

Е6 – произошел обрыв (замыкание) датчика испарителя;

Е7 – произошел обрыв (замыкание) сенсора внутреннего блока;

Е8 – произошла перегрузка испарителя;

Е9 – ошибка в работе дренажного насоса;

Е10 – с пультом управления соединены более 16-ти блоков;

Е11 – с пультом управления соединены более 1-го блока при занятом адресе;

Е12 – ошибки в настройках адресов;

Е14 – совершены неправильные настройки ведущих и ведомых соединений;

Е16 – возникли неисправности в работе вентилятора внутреннего блока;

Е28 – возникли неисправности в датчике пульта управления;

Е30 – возникла ошибка в соединении наружного и внутреннего блоков;

Е31 – осуществление неверной настройки адресов;

Е32 – возник обрыв провода или неверно выполнена последовательность фаз;

Е33 – произошел обрыв обмотки провода;

Е34 – произошло размыкание фазы обмотки;

Е35 – неисправности в работе датчика или повышение температуры в
конденсаторе;

Е36 – произошло отклонение температуры выходного воздуха выше нормы;

Е37 – возникли неисправности в температурном датчике конденсера;

Е38 – возникли неисправности в температурном датчике наружного воздуха;

Е39 – возникли неисправности в температурном датчике нагнетательной трубы;

Е40 – произошло повышение давления в системе;

Е49 – произошло понижение давления или хладагента является недостаточно;

Е53 –   возникли неисправности в термисторе всасывающей трубы;

Е54 – отсоединился датчик низкого давления;

Е55 – возникли неисправности в термисторе температуры внутри компрессора;

Е56 – возникли неисправности или обрыв температурного датчика силового
транзистора;

Е57 – недостаточное число охлаждающей жидкости;

Е59 – не осуществляется запуск компрессора;

Е60 – возникла ошибка в позиционировании компрессора;

Е63 – произошло аварийное отключение внутреннего блока.

E1 — сбой печатной платы внутреннего блока, неправильно подключён пульт дистанционного управления или неисправен.

E2 — дублирование адресов внутренних блоков

E3 — некорректный адрес наружного блока

E5 — неисправна плата управления наружного блока

E6 — термодатчик испарителя замкнут/оборван

E7 — сенсор внутреннего блока замкнут/оборван

E8 — перегрузка испарителя или неисправен датчик

E9 — ошибка дренажного насоса или поплавкового датчика

E10 — больше 16 внутренних блоков соединяются с пультом управления

E11 — больше одного блока соединяются с пультом управления,когда адрес занят

E12 — ошибка настройки адресов

E14 — неправильные настройки соединения master-slave (ведущий-ведомый)

E16 — неисправен вентилятор внутреннего блока

E28 — неисправен датчик пульта управления

E30 — ошибка соединения наружного/внутреннего блоков

E31 — дублирование, неправильные настройки адресов

E32 — неправильная последовательность фаз или обрыв провода

E33 — обрыв обмотки компрессора

E34 — разомкнута фаза L3 обмотки 52C

E35 — высокая температура конденсера или неисправен термодатчик

E36 — недопустимое отклонение температуры выходного воздуха

E37 — неисправен термодатчик конденсера

E38 — неисправен термодатчик наружного воздуха

E39 — неисправен термодтчик нагнетательной трубы

E40 — сработала реле высокого давления 63Н1

E49 — система остановилась, низкое давление или недостаточно хладагента

E52 — сбой в 52С

E53 — неисправен термистор всасывающей трубы

E54 — отсоединён датчик низкого давления

E55 — неисправен термистор температуры внутреннего пространства компрессора

E56 — термодатчик силового транзистора неисправен или оборван

E57— недостаточно хладагента

E59 — не запускается компрессор

E60 — ошибка позиционирования компрессора

E63 — аварийное отключение внутреннего блока

Полная версия кодов ошибок в формате .pdf

Скачать

Коды ошибок для моделей

FDTA28KXE4  FDTWA28KXE4 FDTQA22KXE4

FDRA22KXE4 FDQMA22KXE4/28/36/45/56/71/90/112/140

FDTSA22KXE4

FDUMA36KXE4 FDURA45KXE4 FDEA36KXE4

FDKA22KXE4 FDFLA28KXE4

FDE321HKXE2 401HKXE2 501/631/801/1001/1251HKXE2

FDKY251HKXE2,321HKXE2,401HKXE2,501HKEXE2,631HKXE2

FDFL251HKXE2,401HKXE2,631HKXE2

FDFUA28KXE4 SRK20ZD-S SRK501CENF-L

SRK561CENF-F SCM328CENF-L1 SCM338CENF-L1

SRK25GZ-L1/35/502Z-L

FDC508HES3 808HES3 1008HES3

FDT208-A 258A 308A 408-A 508-A

FDR208-A 258A 308A 408-A 508-A

SCM60ZD-S SCM80ZD-S

SKM2ZD-S SKM25ZD-S

SKM28ZD-S SKM35ZD-S

FDC2001HKXRE2,2501HKXRE2

и др.

СПЕЦПРЕДЛОЖЕНИЕ!
Для владельцев коммерческих объектов и корпоративных заказчиков выполняем диагностику и составляем план ремонтно-восстановительных мероприятий для вашего инженерного оборудования индивидуально, учитывая Ваши пожелания и рекомендации заводов-изготовителей  техники. Подробнее.

Понравилась статья? Поделить с друзьями:
  • Msxml4 dll ошибка
  • Mujuice ошибки слушать
  • Msxml3 dll системная ошибка 2146697208
  • Mujuice ошибки скачать
  • Msxml3 dll ошибка скачивания указанного ресурса