These messages indicate errors which you must correct before a print job
can continue or the printer status return to «Ready».
Ready
Attention
indicator
indicator
(green)
(orange)
Off
Rapid
blinking
Off
On
Slow
Slow
blinking
blinking
Slow blinking
alternately
Off
Slow
blinking
Off
Blinking
Toner
Condition
indicator
(orange)
On
Toner out
» Note:
message
appears when
the Toner Out
Stop in the
Remote Panel
Utility is set to
On.
On
The toner cartridge is
not installed.
Toner empty
*
Media empty
*
Media size error
The size of paper
being printed on is
different from the
size of paper
specified in the
printer driver.
*
Memory full
*
Front cover or top
cover is open.
*
The imaging
cartridge is not
installed.
88 — C110 User’s Guide
Action
Replace the toner cartridge.
» Note:
This
Stop in the Remote
Panel Utility is set to
Off, printing can
continue.
However, the printing
results are not
guaranteed.
Install the all toner
cartridges.
Replace the toner cartridge.
Load media into Tray 1.
Press the Cancel key to
cancel the error.
To print on paper of the size
specified in the printer
driver, load paper of the
correct size into Tray 1, and
then try performing the print
job again.
Press the Cancel key.
If the error is not corrected,
turn off the printer. After a
few seconds, turn on the
printer.
Close the front cover and
top cover.
Install the imaging
cartridge.
If Toner Out
Сигнализация индикаторов
7-9
Попеременно
быстро мигают
*
Ошибка формата
носителя
Формат бумаги,
на которую идет
печать не
соответствует
формату бумаги,
заданному
в драйвере
принтера.
Отмените ошибку
путем нажатия
кнопки Cancel.
При
необходимости
печатать на
бумагу, формат
которой задан
в драйвере
принтера,
зарядите
в Лоток 1 бумагу
соответствую-
щего формата
и попробуйте
выполнить
печатное задание
повторно.
Не горит
Медлен-
но мигает
*
Память полная
Нажмите кнопку
Cancel.
Если ошибка
не исчезнет,
выключите
принтер. Спустя
несколько секунд
снова включите
его.
Не горит
Мигает
*
Открыта передняя
или верхняя
крышка.
Закройте
переднюю или
верхнюю крышку.
*
Блок отображения
отсутствует.
Установите блок
отображения.
Не горит
Быстро
мигает
*
Застрял носитель. Устраните
застрявший
носитель,
закройте крышки
и продолжайте
печатать задание.
Индикатор
Статус
Что надо делать
Ready
(зеленый)
Attention
(оранж.)
Toner
(оранж.)
– Compatible Printer model: OKI C110
– OKI C110 Error Code description:
- Code: 0001
- Description: Transport motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized.
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized.
• The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized. - Causes: Transport motor (M1) Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. – – 2 Check M1 for proper drive coupling and correct as necessary. – – 3 Check the PRCB connector for proper connection and correct as necessary. – – 4 M1 operation check. PRCB PJ8-1 to 6 C110: C-2 C130n: C-2 5 Change PRCB. – – 6 Change DCPU. – –
- Code: 001B
- Description: Rack rotation failure
• The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning.
• The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning. - Causes: Rack motor (M2) Rack positioning sensor (PS5) Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. – – 2 Check M2 for proper drive coupling and correct as necessary. – – 3 Check the PRCB connector for proper connection and correct as necessary. – – 4 PS5 sensor check. PRCB PJ5-11 (ON) C110: C-11 to 12 C130n: C-11 to 12 5 M2 operation check. PRCB PJ5-5 to 8 C110: C-12 C130n: C-12 6 Change PRCB. – –
- Code: 004A
- Description: Duplex unit cooling fan motor malfunction
- Causes:
- Troubleshooting Guides:
- Code: 004C
- Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated. - Causes: Ozone ventilation fan motor (FM2) Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the FM2 connector for proper connection and correct as necessary. – – 2 Check the fan for possible overload and correct as necessary. – – 3 Check the PRCB connector for proper connection and correct as necessary. – – 4 FM2 operation check. PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C110: C-4 C130n: C-4 5 Change FM2. – – 6 Change PRCB. – –
- Code: 004E
- Description: Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized. - Causes: DC power supply fan motor (FM1) Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Check the FM1 connector for proper connection and correct as necessary. – – 2 Check the fan for possible overload and correct as necessary. – – 3 Check the PRCB connector for proper connection and correct as necessary. – – 4 FM1 operation check. HV CN2-1 (REM) HV CN2-3 (LOCK) C110: B-5 C130n: B-4 to 5 5 Change PRCB. – – 6 Change DCPU. – –
- Code: 0092
- Description: Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated. - Causes: Belt positioning sensor (PS6) Imaging cartridge Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. – – 2 PS6 sensor check. – – 3 Change Imaging cartridge. – – 4 Change PRCB.
- Code: 0094
- Description: 2nd image transfer pressure /retraction failure
• The state of the 2nd image transfer retraction position sensor is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive.
• The 2nd image transfer retraction position sensor is in the unblocked state even after the lapse of a predetermined period of time during predrive.
• The 2nd image transfer retraction position sensor is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started.
• The 2nd image transfer retraction position sensor is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started. - Causes: 2nd image transfer retraction position sensor (PS3) 2nd image transfer pressure/retraction solenoid (SD4) Transport motor (M1) Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. – – 2 Check M1 for proper drive coupling and correct as necessary. – – 3 Check the SD4 connector for proper connection and correct as necessary. – – 4 Check the PRCB connector for proper connection and correct as necessary. – – 5 PS3 sensor check. PRCB PJ12-3 (ON) C110: C-2 to 3 C130n: C-2 6 SD4 operation check. PRCB PJ10-6 (REM) C110: C-9 C130n: C-9 7 M1 operation check. PRCB PJ8-1 to 6 C-2 8 Change PRCB. – –
- Code: 0300
- Description: Polygon motor malfunction
• A LOW motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started.
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized. - Causes: PH unit Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. – – 2 Change PH unit. – – 3 Change PRCB. – –
- Code: 0310
- Description: Laser malfunction
• The SOS signal is not detected within a predetermined period of time after the output of a laser has been started.
• The SOS signal is never detected in the image area. - Causes: PH Unit Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. – – 2 Change PH unit. – – 3 Change PRCB. – –
- Code: 0500
- Description: Fuser warm-up failure
• The thermistor does not detect a predetermined temperature value even after the lapse of a predetermined period of time after the current warm-up cycle has been started and the current warm-up cycle is thus not completed. - Causes: Fuser unit Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Change fuser unit. – – 2 For C110: 1. Main switch is turned ON. 2. Open the top cover. 3. Press the following keys in this order. ROTATE TONER key -ATTENTION key – ATTENTION key – ROTATE TONER key. 4. Main switch is turned OFF/ON. For C130n: 1. Main switch is turned ON. 2. Execute [SERVICE MENU] – [FUSER UNLOCK]. See P.103 – – 3 Change PRCB. – – 4 Change DCPU. – –
- Code: 0502
- Description: Thermistor open-circuit failure
• The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started. - Causes: Fuser unit Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). – – 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary. – – 3 Change fuser unit. – – 4 Change PRCB. – – 5 Change DCPU.
- Code: 0503
- Description: Thermistor resistance failure
• The heater lamp remains ON for a predetermined consecutive period of time. - Causes: Fuser unit Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Change fuser unit. – – 2 For C110: 1. Main switch is turned ON. 2. Open the top cover. 3. Press the following keys in this order. ROTATE TONER key -ATTENTION key – ATTENTION key – ROTATE TONER key. 4. Main switch is turned OFF/ON. For C130n: 1. Main switch is turned ON. 2. Execute [SERVICE MENU] – [FUSER UNLOCK]. See P.103 – – 3 Change PRCB. – – 4 Change DCPU. – –
Solve OKI C110 Error codes
- Code: 0510
- Description: Abnormally low fuser temperature
• The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time. - Causes: Fuser unit Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). – – 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary. – – 3 Change fuser unit. – – 4 Change PRCB. – – 5 Change DCPU.
- Code: 0520
- Description: Abnormally high fuser temperature
• The temperature detected by the thermistor is a predetermined value or higher for a predetermined period of time. - Causes: Fuser unit Printer control board (PRCB) DC power supply (DCPU)
- Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). – – 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary. – – 3 Change fuser unit. – – 4 Change PRCB. – – 5 Change DCPU.
- Code: 0F51
- Description: Waste toner full sensor trouble
• Waste toner full sensor detects abnormal situation - Causes: Waste toner full sensor (PS7) Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. – – 2 PS7 sensor check. – – 3 Change PRCB.
- Code: 13C0
- Description: Printer control board malfunction
• Communications with the M/C expansion IO G/A (IC on the printer control board) are not properly carried out. - Causes: Printer control board (PRCB)
- Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. – – 2 Change PRCB.
- Code: 13DD
- Description: Backup data error
• The printer determines that EEPROM is yet to be mounted when the main power switch is turned ON. - Causes: Printer control board (PRCB)
- Troubleshooting Guides: 1 Confirm mounting status of EEPROM on the printer control board, and make modification if necessary. – – 2 Change PRCB.
- Code: 13E2
- Description: Flash ROM write error
• Flash ROM writing is found faulty during a check. - Causes: Printer control board (PRCB) MFP board (MFPB)
- Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. – – 2 Change PRCB. – – 3 Change MFPB.
- Code: 13F0
- Description: Engine control failure
• An undefined malfunction occurs in the engine section (PRCB, etc.). - Causes: Printer control board (PRCB) MFP board (MFPB)
- Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. – – 2 Change PRCB. – – 3 Change MFPB.
- Code: 3C00
- Description: EEPROM installation error
• Contact the responsible people of OKI when not returning in power switch OFF/ON. - Causes:
- Troubleshooting Guides: • Contact the responsible people of OKI when not returning in power switch OFF/ON.
- Code: 3C10
- Description: EPROM data error
• Contact the responsible people of OKI when not returning in power switch OFF/ON. - Causes:
- Troubleshooting Guides: • Contact the responsible people of OKI when not returning in power switch OFF/ON.
– Get more information about Epson XP 15000 troubleshooting, click here
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
Waste Ink Pad Counter Utility Functions:
– Cleaning printhead.
– Ink charge.
– Fix Epson red lights blinking Error
– Fix Epson Service Required Error: A printer’s ink pad at the end of its service life Please contact Epson Support.
– Check the current value of waste ink counters and ink level counters.
– Clear Waste Ink Counters.
– Read and write serial number.
– Read and write USB ID.
– Read and write HEAD ID.
– Make EEPROM dump, backup.
– Paper feed test.
– Nozzle check.
– Color check pattern.
– Initialize (disable) PF deterioration offset.
– Retrieve device information
Contact us to get support with OKI C110 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.
Обращаю внимание, что ошибки с номерами 300-600 являются пользовательскими ошибками, которые кроме номера содержат довольно подробное описание самой ошибки, а при нажатии на кнопку HELP можно получить подробное описание того, как эти ошибки разрешить.*Некоторые из этих ошибок приведены ниже
Пользовательские ошибки
Сигнализация индикаторов
Сообщения об ошибках
Сообщения об ошибках сигнализируют наличие неполадок которые необходимо устранить В противном случае принтер не сможет продолжить обработку задания или перейти в режим готовности.
Индикатор
Статус
Что надо делать
Ready (зеленый)
Attention (оранж.)
Toner (оранж.)
Не горит
Быстро мигает
Горит
Кончился тонер
Данное сообщение появится в случае если параметр «Кончился тонер – стоп» в утилите Удаленная панель настроен на Вкл.
Замените тонер-картридж.
В случае если параметр «Кончился тонер – стоп» в утилите Удаленная панель настроен на Выкл то печать может продолжаться Однако качество печати не гарантируется
Не горит
Горит
Горит
Не установлен тонер-картридж.
Установите все тонер-картриджи.
Кончился тонер
Замените тонер-картридж.
Медленно мигает
Медленно мигает
Кончились носители
Зарядите носители в Лоток 1.
88 — C110 User’s Guide
Error Messages
These messages indicate errors which you must correct before a print job
can continue or the printer status return to “Ready”.
Ready
indicator
(green)
Attention
indicator
(orange)
Toner
indicator
(orange)
Condition
Action
Off
Rapid
blinking
On
Toner out
» Note:
This
message
appears when
the Toner Out
Stop in the
Remote Panel
Utility is set to
On.
Replace the toner cartridge.
» Note:
If Toner Out
Stop in the Remote
Panel Utility is set to
Off, printing can
continue.
However, the printing
results are not
guaranteed.
Off
On
On
The toner cartridge is
not installed.
Install the all toner
cartridges.
Toner empty
Replace the toner cartridge.
Slow
blinking
Slow
blinking
*
Media empty
Load media into Tray 1.
Slow blinking
alternately
*
Media size error
The size of paper
being printed on is
different from the
size of paper
specified in the
printer driver.
Press the Cancel key to
cancel the error.
To print on paper of the size
specified in the printer
driver, load paper of the
correct size into Tray 1, and
then try performing the print
job again.
Off
Slow
blinking
*
Memory full
Press the Cancel key.
If the error is not corrected,
turn off the printer. After a
few seconds, turn on the
printer.
Off
Blinking
*
Front cover or top
cover is open.
Close the front cover and
top cover.
*
The imaging
cartridge is not
installed.
Install the imaging
cartridge.
The most common error codes.
Error | |
---|---|
0502 | Description: Thermistor open-circuit failure • The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started. |
0001 | Description: Transport motor malfunction • The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized. • The rack positioning sensor is in the blocked state when the rack motor remains de |
0503 | Description: Thermistor resistance failure • The heater lamp remains ON for a predetermined consecutive period of time. |
001B | Description: Rack rotation failure • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning. • The count value of the e |
0510 | Description: Abnormally low fuser temperature • The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time. |
0502 | Description: Thermistor open-circuit failure • The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started. |
0001 | Description: Transport motor malfunction • The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized. • The rack positioning sensor is in the blocked state when the rack motor remains de |
0503 | Description: Thermistor resistance failure • The heater lamp remains ON for a predetermined consecutive period of time. |
001B | Description: Rack rotation failure • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning. • The count value of the e |
0510 | Description: Abnormally low fuser temperature • The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time. |