9-2-2
Error
code
(Hex)
0001
CPU Unit watchdog timer error
0002
CPU Unit service monitoring error (Servicing
from the CPU Unit is not performed at fixed
intervals.)
0006
Other CPU error
000F
CPU Unit initialization error
0011
Event timeout
0012
CPU Unit memory error
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Error
00 Hex
Monitoring time (ms)
Bit 14 ON:
Bit 11 ON:
Other bits:
00 Hex
MRC
01 Hex: Read error
02 Hex: Write error
9 Troubleshooting and Maintenance
Detail code
First byte
Second byte
00 Hex
Duplicate unit number setting
Unit not in registered Unit
Configuration in the CPU Unit
Reserved by system
00 Hex
SRC
03 Hex: Routing table
04 Hex: CPU Bus Unit
system settings error
05 Hex: Special Unit CIO
or DM allocation
Record
stored in
EEPROM
Yes
Yes
Yes
Yes
Yes
Yes
9
9-29
Автор: | uralmaster [ Ср ноя 14, 2012 08:32 ] |
Заголовок сообщения: | Модуль DRM21 (DRM21-V1) |
Доброго времени суток! Подскажите пожалуйста, как правильно подключить и запустить модуль DRM21 (DRM21-V1). Интегратор пишет «Device Type of #60 is different». И в дереве рядом с девайснетом рисует квадратик с молнией. На самом модуле мигают «60» Е0″ по очерёдно, MS мигает зелёным. На подключенный блок DRT1-TSO4T не реагирует. Проц CS1G-CPU45H не в аларме, стабильно в руне. В программере вроде всё нормально IO Table вроде правильно прописал. OMRONами занимаюсь давно, но прогить стал только начинаю. |
Автор: | Олег [ Ср ноя 14, 2012 08:55 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
В инструкции ошибки расписаны, на русском. |
Автор: | uralmaster [ Ср ноя 14, 2012 09:04 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
Пожалуйста дайте ссылку на инструкцию на русском, я так и не нашёл. А питалово всё подключено. всё по феншую… |
Автор: | uralmaster [ Ср ноя 14, 2012 12:06 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
Не помогло… не горит светодиод NS, а MS горит стабильно |
Автор: | Олег [ Ср ноя 14, 2012 12:20 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
если память не изменяет DRT1-TSO4T с питанием от сети, т.е. если питание в сеть подали на модуле хоть что-то должно загорется. |
Автор: | uralmaster [ Ср ноя 14, 2012 12:34 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
DRT1-TSO4T запитан от внешнего 24V на нём тоже MS зелёная а NS не горит. А что такое терминатор? |
Автор: | Олег [ Ср ноя 14, 2012 13:23 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
терминатор, сопротивление кажется на 120 ом, но на него другая ошибка. |
Автор: | Andy [ Ср ноя 14, 2012 14:41 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
Не горящий индикатор NS при зеленом MS на слэйве так же говорит о косяке с адресом слэйва данного слэйва. Адрес мастера какой? А адрес слэйва? Используется ли автоопределение? |
Автор: | uralmaster [ Чт ноя 15, 2012 10:30 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
Всем огромное спасибо! сетка встала на место (по крайней мере визуально). Только CX-интегратор всё равно ругается, буду продолжать дальше… |
Автор: | AnV [ Чт сен 17, 2020 09:39 ] |
Заголовок сообщения: | Re: Модуль DRM21 (DRM21-V1) |
Здравствуйте! Такая проблема-купили модули DRM21 ver1.1 (версия указана на корпусе модуля), однако программно версия определяется как ver0.0. Модули были куплены для резерва ПЛК, чтобы скомпоновать новый ПЛК и сделать полную копию ПЛК, который сейчас в работе. Однако я не могу сделать Backup ПЛК, т.к. версия модуля DRM21 в файле Backup — v1.1, а версия, считываемая из модуля — v0.0. Соответственно Backup я выполнить не могу. Что это? Поддельные модули? Можно ли обновить версию модуля? |
Страница 1 из 1 | Часовой пояс: UTC + 3 часа (Russia: MSK) |
Powered by phpBB © 2000, 2002, 2005, 2007 phpBB Group http://www.phpbb.com/ |
Reason: registered in the scan list from the station does not exist or is a local master node number is registered in the scan list of the master station.
Countermeasures:
① initial commissioning or increase / decrease the slave node:
a. Check the baud rate from the master station, you need to set the same;
b. Using CX-Integrator software scans the table to re-register the master module.
② device was originally normal communication is done without any changes, the sudden appearance of an error message D5:
a. Check the wiring of the communication cable is loose;
b. In the two terminals of the network whether the terminating resistor;
c. Check the current speed and distance network, consider reducing the baud rate of the network, using 125Kbps baud rate for communication;
d. DeviceNet special cable network recommended;
e. Check around whether the communication device has a signal interference.
|
#1 |
Member
Join Date: Nov 2013 Location: Ayutthaya Posts: 19 |
Omron DRM21 error code Dear : every one |
|
|
|
#2 |
Member
Join Date: Feb 2005 Location: Grand Rapids, MI Posts: 1,309 |
You need to download the W380 manual. E2 is a timeout error. Have you set up the scan list for the DRM21? Hope this helps. |
|
|
|
#3 |
Member
Join Date: Nov 2013 Location: Ayutthaya Posts: 19 |
Thank you so much for your reply. I already set devicenet now ok. |
|
|
|
#4 |
Member
Join Date: Feb 2005 Location: Grand Rapids, MI Posts: 1,309 |
You can find the answers in the Z278 manual. |
|
|
|
#5 |
Member
Join Date: Nov 2013 Location: Ayutthaya Posts: 19 |
Quote:
Originally Posted by gtsuport You can find the answers in the Z278 manual. Thank you so much… I just try it. |
|
|
MrPLC.com sells used surplus products. MrPLC.com is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by MrPLC.com come with MrPLC.com’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.
Rockwell Disclaimer: The product is used surplus. MrPLC.com is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because MrPLC.com is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, MrPLC.com makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. MrPLC.com also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. MrPLC.com also makes no representations as to your right to install any such firmware on the product. MrPLC.com will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.