Hello Everyone,
Posting here for the 1st time and i hope i can get some help. I have a 2013 Prius V. At around 374,000 km’s, the head gasket blew. After doing some detailed research i was able to order a new engine with only 16000 kms, and installed it myself. I removed everything and installed it back without breaking anything. The good news is that my car runs like brand new and there are no issues with the engine.
The problem is that i happen to spill some coolant on the A/C compressor communication port (Pic included) in the process. I did not notice that port being wet when i was plugging everything back. After putting everything back and restarting my car, it gave me 2 codes — ‘B1498 Communication Malfunction (A/C Inverter Local)’ and ‘ P0AA6 Hybrid/EV battery Voltage system isolation fault’.
I took it to the dealer to have it diagnosed and also have them check how my DIY on engine change went. They came back to me saying «you did a perfect job» except you need a new A/C compressor to fix those 2 codes. For which they quoted me $5500 CAD for. Obviously i was not going to pay that kind of money and got lucky to find a used A/C compressor for $100. After installing this compressor with working communication port, the P0AA6 code went away and there are no signs on the dash.
The issue that still remains is with the B1498 Communication Malfunction code. From what i understand, the comm port on A/C compressor got water damaged completely which also triggered the P0AA6 code, but with the new compressor P0AA6 code went away. But it seems like there is still some issue on the harness side or whereever this harness goes which is still giving me the B1498 code. BTW the A/C compressor doesn’t come alive when i turn the AC on.
Thank you in advance,
Deep -
The compressor receives an inverter control signal from the power management ECU. I am guessing this is the communication malfunction you are experiencing. The ECU talks to the A/C amplifier assembly for data input. Check those connections and also confirm that the coolant is completely cleaned from the comm port.
-
- Joined:
- Apr 27, 2017
- 3
- 0
- 0
- Location:
- Edmonton
- Vehicle:
- 2013 Prius v wagon
- Model:
- Five
Thanks for the reply. The ports are completely dry, that is for sure. I checked the wiring harness for continuity using a multimeter and the wiring harness is good. The wiring harness from AC compressor ends in the fuse box, which is where i performed the test.
What should my next step be? Which connections are you mentioning ? Where is the ECU and AC amplifier.
I really appreciate anyone helping me out on this. Thank you.
-
- Joined:
- Apr 27, 2017
- 3
- 0
- 0
- Location:
- Edmonton
- Vehicle:
- 2013 Prius v wagon
- Model:
- Five
This is the port i am referring to on the AC compressor that i dropped coolant in. I have changed the AC compressor since. But i am still getting B1498 code. Check my above posts for more info.
Thank you
Attached Files:
-
VintageGold
Junior Member- Joined:
- May 16, 2018
- 27
- 12
- 7
- Location:
- Utah
- Vehicle:
- 2012 Prius
- Model:
- Four
I know this thread is old but were you ever able to resolve your issue? I had my engine replaced recently and I’m getting this code now.
-
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
Well, this is now another person wondering about this code…. I did a head job and during that, some coolant briefly dropped into the control connector of the A/C compressor. Now I have a 1498 error too. I never had that before. I wouldn’t think that having fluid temporarily drop into the connector would cause a problem. They are usually sealed and I definitely cleaned everything out and ensured it was dry before reassembly. But now the compressor turns on for a bit and then turns off and throws the B1498 error.
Does anyone know a way to fix this? What is the problem? Did the internal inverter board somehow get fried?
-
- Joined:
- Jan 8, 2017
- 2,515
- 3,233
- 9
- Location:
- California
- Vehicle:
- 2016 Prius
- Model:
- Three Touring
If the connector was disconnected when the spill occurred, there could be coolant residue on the connector housing, terminals, or inside the unit, causing a poor connection or intermittent terminal-to-terminal or terminal-to-ground faults. Before replacing any expensive parts, try throughly cleaning the connector.
You could also try steps 1 through 5 of the troubleshooting procedure for DTC B1498/98 in the Air Conditioning System section of the Repair Manual (more info). This procedure includes checks for CAN or hybrid control system DTCs and for wire harness faults.
-
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
Thank you for the response Elktroingenie…. I really do appreciate your taking the time you took to add some ideas….
I immediately removed the coolant that splashed in there and blew it clean. Two weeks passed while I was doing my head job, and then everything went back together. With about 2000 miles on the car, it started to get warm outside and that is when the A/C issue cropped up. I went back and confirmed all connections and did take an extra step of thoroughly cleaning the connection. I used an electronics aerosol on both the compressor and the connector, and lightly drew a needle file across the pins to break any crud that could have been there. The problem remained, but I really think the connection is fine now. I also opened the connector on the wire side to see if there were any crushed wires; there were none.
I do have a little more information though. I’ve been trying to correlate what might trigger the problem or be related. This morning (very cool), the A/C worked perfect and the sight glass shows proper level (that was confirmed by an independent shop, by the way… they said there is no leaks and it is all charged). I jostled the wires around to see if there was a position where everything stopped… Again, no problems; it blew fine.
Now the observation. Yesterday when it was hot, I noticed that the pump was on when the fans were on, and the opposite was also true. As soon as the fans stopped, the pump stopped (or shortly thereafter). This morning it was very cold and the fans were on the whole time the pump was on (after 5 minutes of having it on, I gave up… never did fail). Part of me is wondering if I’m on a wild goose chase. Maybe this B1498 (which I’ve not seen on my cheesy FixD OBD reader, the independent shop told me about that… oh, and yes, I’m getting a better reader) is tangential. Maybe the lack of a fan causes the pump to heat up and go into a thermal shutdown. That would then cause the communications to stop and, therefore, the B1498. I’m wondering if that is possible… Thoughts?
I do know that this morning, the vertical aluminum bulb that is in the compressor line (not sure what this is… an expansion chamber) was *very* warm, along with the pump. But this morning, all of that was very cool. Now, it is true that the temperature outside was warm and it was, as stated, cool out this morning, but the mechanical compressing of the freon will generate a lot of heat. If the evaporator coil isn’t getting air drawn through it to cool the freon down, then that heat is going to stay in the system.
Assuming this seems like a plausible scenario, I’d love to hear how one might diagnose the root cause of why the fans would not come on when the A/C pump is on. Sadly, I suspect the opposite is also true though. The ECU may shut the fans off if it detects a communications issue (B1498). I am aware that this whole vein of thought has two avenues of what is affecting what.
P.S. Thank you for the suggestion on the diagnosis steps and such. I became aware of the temporary TIS subscription just recently and I very well will try that route. Because it is time limited, I need to be sure I’ll have a block of time to make use of the resource before it expires. But that is on the agenda if I cannot otherwise figure this thing out.
-
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
Slight update…. I’m working at home for my real job now, which gives me the opportunity to run out between meetings and to see if I can draw some conclusions about when the A/C works and when it does not…..
As I mentioned before, the compressor worked perfectly this morning when it was very cold. As such, I was very curious to see what would happen as the weather started to warm up. Sure enough, I pressed ON and the the engine, fans and A/C all came on. Eventually, the engine turned off (normal) and the radiator fans continued to run, as did the AC compressor. I could see fluid passing the sight glass and the low side was crispy cold…
And then….. The fans turned off! I could immediately hear the compressor turn off, and a visual inspection of the sight glass no longer showed fluid moving past. For a very brief moment, the fans came on again (and the fluid flowed in the sight glass), then the fans turn off, yada yada yada.
So, the conclusion is that when the fans are on, the pump is on. What I don’t know is which behavior is causing no A/C. Is it an issue with the A/C compressor (B1498?) that turns off the compressor *and* thus the fans? Or is it the fans turning off for some reason that causes the ECU to say «wow! we don’t run the A/C without the fans running, so I’m turning off the compressor»…. Or, is there some electrical issue (relay, wiring, etc) which is influencing/causing all of this?
I can say that I’ve moved the wires around along the length of the harness to feel pretty confident in saying that I don’t think there is an issue with the wiring (yes, I know this is not definitive and I will eventually check the continuity when I get time and if there is no other resolution).
Again, one final consideration here that I mentioned before. I have not personally seen the B1498 error. Further, when I press REC plus AUTO and START (no foot on brake), I get a flashing ’00’ on the temperature temp control. I understand that this means I have *no* codes. I was only told about the B1498 by a competent independent mechanic to whom I gave the car in an attempt to resolve the A/C issue. He eventually said that he could not figure out what was going on, but he was confident that the pump was working (although that doesn’t mean there isn’t an intermittent issue in the pump’s inverter control board) and, more importantly, that the system was charged and not leaking. But the point is that I don’t want to draw too much focus on the B1498. I think that my last scenario where a thermal overload within the pump could very well be true….
So, that is about it for now…. I am curious to hear if it is normal for the A/C to come on/off (as well as the fans) when the A/C is set to AUTO and LO. What I’m getting at here is… Maybe I really did have a connector issue and I’ve resolved that, and now the system is just behaving normally? I’ve owned the car since new (10 years), but I’ve never paid attention to the nuances of the A/C compressor.
-
VintageGold
Junior Member- Joined:
- May 16, 2018
- 27
- 12
- 7
- Location:
- Utah
- Vehicle:
- 2012 Prius
- Model:
- Four
Man, I did that thing that drives me crazy: people find a solution and don’t post back about it.
Sorry about that.
In my case, the compressor didn’t work at all and it had to be replaced. At the time (Aug 2018), it was about $125.
-
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
Thanks for posting!
Man, if I could a compressor replaced for $125 I’d do it just to see if it worked. But the compressor now is about $1300 (new…. $500 remanufactured, $150 as a gamble from a junk yard), $300 for Toyota’s oil, and about $40 for an equivalent, and about $125 for the charging of the system. That adds up to enough that I want to be sure I really need to replace it first.
-
Ah. Yes, that can be normal behavior. It’s more normal when set for AUTO and a temperature than when set for AUTO and LO, though.
The compressor is variable speed. Depending on how hot it is outside and how much cooling you’re asking for, if you have a scan tool to watch the «AC watts» parameter, you could see the compressor running at over two thousand watts full out, all the way down to maybe 250 or 300 watts when only a little cooling is needed. If less cooling is needed than that, it will cycle off and on (so, between 0 watts and 350, 450 or so).
If the fans aren’t needed for engine or inverter cooling, they will also cycle off when the compressor does.
I am a little more puzzled that the compressor would be cycling off when the temp is set for LO. But this could happen if the evaporator temperature (another parameter you can watch with a scan tool) gets down to the range for potential icing, or if the liquid-line pressure (another watchable one!) goes out of bounds.
-
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
Fantastic information, Chapman. Thank you!
I don’t have a scan tool, unfortunately, but I do have one on order. Because I’m not a professional mechanic, I cannot really justify a commercial grade unit. I currently have a FixD type which is completely inadequate for higher level stuff like what we are talking about. However, it works *really* well for increasing confidence for when my daughter or wife are using the car. They know/care little about mechanics, and if the service light goes on, this way it will immediately alert me wherever I am. I can see it and tell them that they really do need to get off the road because the water pump failed (type of thing).I have an OBDLink MX+ on order, and it should be here in a few days. That should allow me to do some ‘live’ testing as you are suggesting. This is actually where I am going with it all too. I think I may really have had a poor connection in the connector before, but everything might be working perfectly now. My wife drove the car to school yesterday with LO and full fan. On the trip to school, the A/C was on and cranking cold air like there was no tomorrow; that trip was about 13 minutes. On the way back, however, the A/C stopped and she had to open the windows. That still doesn’t feel «correct» to me, but I do have to note that the car was in ECO mode too. I have learned that this can affect the A/C compressor «on» times too.
I have yet to see the B1498 myself. I suspect the FixD is not capable of showing those, and my other OBD units are all pretty sketchy. The MX+ will hopefully resolve that hole. But I *would* expect a 14 and 98 to show up on the temperature display, assuming the REC + AUTO trick works on a 2012 Prius V heating system.
-
As I understand it, ECO mode puts a cap on the top power the A/C will run at. So in ECO mode, instead of running flat out under high demand, it will run up to around two thousand watts or so. I don’t think ECO mode does anything directly with cycle times.You shouldn’t expect a 14 and a 98, just a 98. The display shows two-digit abbreviated versions of DTCs. For the HVAC, they all happen to be the xy digits of a corresponding B14xy DTC (I think). So if you ever saw a 14 and a 98, that would mean you also had a B1414 code (which isn’t a thing … at least in my Gen 3 liftback manual).
One thing not to get too excited over, if you ever see it, is 21 (B1421) … that just means there’s not much light shining on the dash top photosensor at the time you ask for codes.
Be thankful you’re not working on one of the other systems, like the brakes, where the two digit abbreviations are not just the last two of the DTC, or sometimes are and sometimes aren’t (like C1336 has blink code 98)!
Reading parameters like liquid pressure, AC watts, and so on, doesn’t necessarily take a fancy scan tool, just one that you can teach the corresponding PIDs to. The smartphone app Torque is an example. You can find files with the Prius-specific PIDs in Torque’s import format.
-
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
Thanks for the info on the expected digit display on the temp control. I had assumed that I’d see a fast flash of 14 and 98, then a long pause, repeat. But it makes sense that that they’d leave off the 14, I guess. At any rate, all I’ve seen is 00. I don’t know if/how those codes get reset through the approach we are discussing for viewing. Maybe it is just when you turn the car off again?
I think you can get Torque to work on the FixD, but I don’t have that app yet. It is good to know that a fairly inexpensive OBD will work with a more capable program though. I’ve gone through my share of ELM type OBD and I’m pretty fed up with them. Some may work fine, but I’ve not had good luck. This is why I bit the bullet and decided to get a MX+. They seem to have a fairly decent set of reviews on different sites, and at least I’m buying something from a «real» company. Most of the ELM guys are all weakly rebranded products from some shop in China for which there is no/little traceability. Been there, done that….
-
- Joined:
- Jul 17, 2018
- 1,499
- 504
- 3
- Location:
- SE Texas
- Vehicle:
- 2011 Nissan LEAF
- Model:
- —-USA—-
Tech stream with cable. Check ebay.
It the toy software toy dealerships use. Under $50 -
- Joined:
- Oct 20, 2011
- 123
- 52
- 0
- Location:
- Sunnyvale, CA
- Vehicle:
- 2012 Prius v wagon
- Model:
- Five
I wanted to give a quick update….checked for broken wires and could find none. After cleaning the contacts, things worked better, and that is a tell. Given this experience, and that of the original poster to this thread, I have come to what I believe is the likely problem.
The compressor is actually a neat device. It has a variable frequency drive (VFD) board inside it so that the ECU can control the amount of power being used by the compressor. That is cool, but the problem is that the idiots at Denso appear to have used a connector that doesn’t have the pins molded into the plastic (my theory). In addition, the connector is upwards facing. This means that *any* fluid that happens to drop on the connector can leak into the top part of the compressor where the VFD is located. That is an inexcusable weak point, in my honest opinion. Sure, you shouldn’t be splashing coolant around, but you also build something with a defensive posture in mind (or you should).
Anyhow, I believe that coolant is not a very good dielectric and I suspect that even a small amount of coolant will drop onto the board and cause issues. Now comes the interesting thing… How to fix this (again, assuming I’m right).
The *best* solution would be to remove the top cover and you could easily clean the board. Unfortunately, although the VFD board is clearly not pressurized, the connections to the 3 phase motor have a rubber seal around them that press against the board. Without having taken a compressor apart, I am guessing that when you take off the cover, you’ll relax the pressing of that seal, and all your R134a will quickly escape (and cause havoc on the environment, so don’t do it!). So, the only option is to try to dilute/clean the board by introducing more fluid. Therein lies the conundrum. The best thing to do is to use a PCB or contact cleaner. But these are high VOC fluids, which means that they are flammable. Because they are being introduce into a closed cavity, they likely won’t flash off very much, so the VOCs will remain. Technically this could even be a tiny bomb if you filled the thing up; however, I’m guessing we are talking about literally a tiny drop, which I seriously doubt could blow off the cover at all (worst case scenario).
Probably the best thing would be to evacuate the system, remove the cover (spoiler: you need to figure out how to remove the special bolts), clean everything, reassembly and then charge again. But, the reality is that I’m not even positive that the fluid can leak through the pins. Therefore, I went ahead with the «fill the connector with contact cleaner, wait 10 seconds, then gently blow out the remaining fluid into a ran (careful… don’t want it in your eyes, etc). At the very least, this helped clean the contacts (I also used a tiny file to draw across the pins… not to file but to break any corrosion that might be there). If the pins are embedded, then nothing got into the cavity. If not, then a tiny amount did. And, if by chance my compressor fries, well, I’ll have to get a new one and recharge anyhow. There isn’t a huge downside to the experiment.
So, what are the results? So far, the car seems to no longer have an issue with the AC. It hasn’t been driven extensively, and the weather has gotten a lot cooler more recently so the need for AC has been reduced. But, while I was using the AC, it didn’t stop at all. Previously, I would run into problems within 15 to 30 seconds (or the compressor wouldn’t even come on). Is this success then? I don’t know… ONly time will tell.
Finally, there is near zero information out there about the Denso pumps. There is a single, and interesting, video of a guy taking apart a Denso AC pump on YouTube but, sadly, he doesn’t really show much of the VFD board.
Full disclosure: I am an amateur and a flaming idiot. Don’t trust anything I say or use this as a recommendation… If you decide to review my thoughts and take action on them, you do so at your own risk. I assume absolutely no responsibility or liability. I’m just an amateur bloke that is postulating how some of this MIGHT work.
-
I am pretty sure there’s a thread here where somebody worked on that. If I remember right, there was frustration involved with the slack available between the connector and board, or board and motor, or something; anyway, a challenge to usefully disassembling without cutting or desoldering something.
Sometimes, another pair of eyes can help. After all, they had to have a way of assembling the thing.
Найдена следующая информация по ошибке B1498 для автомобиля TOYOTA PRIUS (2015-201_) XW50:
На русском языке:
Короткое замыкание на датчик удара крышки багажника
На английском языке:
Decklid Punch-Out Sensor Ground Short
Вы можете задать вопрос или поделиться опытом устранения ошибки B1498 на автомобиле TOYOTA с другими пользователями.
Возможную причину возникновения и советы по устранению можно найти в каталоге причин и советов:
Найти причину >>>
Ошибки (коды ошибок) полученные от прибора, сканера требуют правильной интерпретации информации, дабы не тратить время и деньги на замену работающих элементов автомобиля.
Проблема зачастую кроется намного глубже чем кажется на первый взгляд. Это& вызвано теми обстоятельствами, что информационные сообщения содержат, как было выше сказано, косвенную информацию о нарушении работы системы.
Может быть полезным для решения вопроса по устранению неисправности у Toyota Prius:
Возможные симптомы — Подсветка двигателя включена (или предупреждающая лампа обслуживания двигателя).
Короткое замыкание датчика пробоя Decklid — это общее описание кода B1498, но у производителя может быть другое описание. В настоящее время у нас нет дополнительной информации о коде B1498 OBDII.
Ошибки полученные от прибора (сканера) требуют правильной интерпретации полученной от него информации, дабы не тратить время и деньги на замену работающих элементов автомобиля.
Вам может быть полезна информация для устранения неисправности:
Возможные симптомы — Подсветка двигателя включена (или предупреждающая лампа обслуживания двигателя).
Короткое замыкание датчика пробоя Decklid — это общее описание кода B1498, но у производителя может быть другое описание. В настоящее время у нас нет дополнительной информации о коде B1498 OBDII.
Сезон на носу, а у вас в салоне едва дует прохладой. Вашему вниманию ниже подробный гайд. Для начала проведем диагностику, чтобы понять, что неисправно. Какие детали необходимо поменять, например, в случае механической поломки компрессора? На этот случай есть бюллетень за 13 мая 2015 T-SB-0083-13 A/C System Diagnosis After Component Failure, в котором описан алгоритм отсеивания пригодных компонентов. Известно о нескольких производственных дефектах системы кондиционирования и отопления, а именно:
— плохочитаемая панель управления — бюллетень за 23 ноября 2009 T-SB-0387-09 A/C Control Display Difficult to Read,
— дефектный компрессор (описано в отдельной записи по его выбору), еще известны случаи попадания влаги в инвертор компрессора;
— сливной шланг испарителя забивается насекомыми, решение описано в TSB за 3 декабря 2018 T-SB-0033-14 HVAC Evaporator Drain Hose Clogged Due to Insect Intrusion.
Последовательный алгоритм, начиная от обычной заправки, разгерметизации после ДТП и до подозрения на неисправность компрессора:
1. Хладагент (хладон, «фреон») R-134a. Заправляем по весам, 470 г, например, Honeywell или DuPont, с вакуумировкой не менее 40 минут.
a) Проверка.
Этот документ поможет в поиске утечек:
BE-8122T-TMC Порядок проверки соединения линии хладагента системы кондиционирования.
b) Процедура замены.
Инструмент.
Заправлять с помощью станции, работающей именно с POE маслом или обоими типами. Или вручную.
2. Масло на основе POE. Выбор масла вынес в отдельную запись.
При замене конденсатора необходимо 40 мл.
При одновременной замене конденсатора и компрессора на б/у нужно залить до 130 мл в последний.
В новый конденсатор иногда кладут 40 мл. Новый компрессор поставляется уже заполненным для всей системы (130 мл).
3. Осушитель (фильтр-осушитель) 8474 DRYER, COOLER. Менять обязательно на новый при разгерметизации системы. Уже установлен в новый конденсатор, но можно купить отдельно. Оригинальный (88474-47030) стоит запредельно. Нужна помощь с аналогами. AVA TOD349 не подходит (меньше по размеру, фильтр-пробка без резьбы, кольца иного размера).
4. Конденсатор (конденсер, теплообменник, радиатор конденсатора) 88450 CONDENSER ASSY, W/RECEIVER (с установленным осушителем). Выбор конденсатора вынес в отдельную запись.
a) Проверка без снятия с авто. Если поврежден, то меняем на новый.
b) Снятие (EU 2012-10 — 2014-05).
c) Разборка для замены осушителя.
d) Повторная сборка после этого.
e) Установка (EU 2012-10 — 2014-05).
5. Компрессор 88370 COMPRESSOR ASSY, W/MOTOR. Выбор компрессора здесь.
a) Проверка старого и купленного на замену б/у компрессора Меняем только, если не подлежит ремонту.
b) Снятие (EU 2012-10 — 2014-05).
С б/у компрессора сливаем всё старое масло и утилизируем! Промываем сольвентом, инертным к обмоткам статора. Во всасывающий коллектор (туда вставляется шланг низкого давления на картинке) заливаем такое же количество нового масла, что и слили (в случае герметичности остальных компонентов).
c) Установка (EU 2012-10 — 2014-05).
Руководство по установке от Denso.
6. Кольца уплотнительные:
(2) O-RING Toyota 90099-14119, 1 шт. в случае замены конденсатора,
(1) O-RING Toyota 90099-14120, 1 шт. в случае замены конденсатора (+1 шт. — компрессора),
(3) O-RING Toyota 90099-14121, 1 шт. в случае замены компрессора.
7. Крепеж. Возможно кому-то понадобятся:
a) Болты, скрепляющие конденсер с радиатором инвертора, 90091-40641 или 90105-06346 (новая ревизия), требуется 4 шт.
b) Болты крепления трубок непосредственно к конденсеру 91551-80625 или 90105-T0052 (азиатский завод) или 90105-C0043 (китайский завод), 2 шт.
8. Фильтр салона:
— Toyota 87139-50100 (DPF — DEODORANT & POLLEN FILTER — угольный),
— Toyota 87139-76010 (MICRO DUST FILTER — обычный).
Рекомендую не гнаться за оригиналом, а взять качественный аналог.
© Max Kaminsky. При копировании указывайте ссылку на автора.
Все купили? Осталось установить и заправить у профессионалов.
Слово предоставляется ofrost (известный специалист по холодильным установкам):
«Не вздумайте шутить с маслом, попадете на компрессор.
Причины поломки спирального компрессора следующие:
— перезаправка и, как следствие, высокие давления нагнетания и возможность гидравлического удара на влажном ходу;
— неконденсируемые примеси, а именно воздух и влага в системе;
— забитый теплообменник конденсатора и, как следствие, высокие давления конденсации;
— вынос продуктов износа в систему, что требует регулярного контроля и замены патрона-осушителя в коллекторе конденсатора.
Но основная причина неакуратность и раздолбайство при обслуживании и заправке системы хладагентом.
Сейчас разучились заправлять и настраивать систему кондиционера вручную. А ручная работа всегда ценилась выше. Процедура заправки сейчас свелась к банальному присоединению к заправочной станции, а кто, и сколько раз, каким маслом, каким фреоном и т. п. заправлялись до Вас, только на понятиях сервисменов. А в заправочных станциях ещё и фильтры надо менять, о чём многие и не подозревают. И вырисовывается следующая картина, приезжаешь на такую заправочную станцию, а перед тобой перезаправляли старую шулалайку с аксиально-поршневым компрессором. Принцип работы заправочной станции в том, что она отсасывает фреон, сепарирует масло и потом заливает нужное количество фреона и свежее (или отфильтрованное) масло. Для спирального компрессора с электроприводом нужно СВОЁ масло и мешать его с другими видами не комильфо. В заправочной станции фреоно-масляные смеси циркулируют по одним трассам и, хорошо если не грязь предыдущей машины, то уж часть масла точно достанется Вашей. Поэтому заправляйтесь только на заправочной станции, которая заправляет только гибриды с электроприводом компрессора, или вручную, старым дедовским способом.
Лучше недозаправить, чем перезаправить.
Тогда по крайне мере смогут сработать аварийные защиты реле давления по низкому давлению и тепловое реле компрессора. Но компрессор останется жить.
Наличие пены в глазке не всегда говорит об отсутствии хладона. Пена говорит об недостаточной конденсации газообразного хладона в жидкую фазу, а это часто бывает при загрязнении оребрения теплообменника конденсатора, при позднем срабатывании вентилятора конденсатора, при наличии неконденсируемых примесей и много ещё причин, начиная от некорректной работы терморегулирующего вентиля до объёмных потерь на компрессоре. Поэтому просто доливать хладон «по глазку» по крайне мере пошло.
При высоком давлении конденсации в смотровом окне появляется пена. Т.е. или не работает вентилятор обдува конденсатора или засор теплообменника конденсатора.
При заливе масла со стороны напорной магистрали приведёт к гидравлическому клину в спирали и поломке последней. Представьте машину на конвейре, система новая сухая. Поставили компрессор со 130 мл масла, плеснули 470 г фреона и поехали. В процессе масло размазалось по всей системе. Потом меняете конденсатор, старый с «расмазанным» маслом убираете, ставите новый, сухой. Исходя из опыта и добавляют 40 мл чтобы общее количество масла в системе осталось неизменным. Если меняете компрессор на новый с маслом, то в системе может образоваться переизбыток масла, однако, как правило, излишки залегают в жидкой фазе, т.е. в конденсаторе, т.к. растворимость масла в среде фреона есть величина постоянная и на работу компрессора в газовой фазе не влияет. Полная промывка системы процедура сложная и недешёвая. Принцип её заключается в том, что из системы убирается ТРВ (терморегулирующий вентиль), вместо него ставится байпасc (а это разборка панели в салоне), и на специальной установке с фильтрами через систему прокачивается сольвент или фреон R-141b. Все остальные полумеры, как правило, полностью систему не очищают. Однако к такому координальному процессу прибегают при выносе продуктов износа в систему или при длительной разгерметизации системы. Понять необходимость промывки можно по смотровому стеклу. Если стекло прозрачное и с внутренней стороны нет следов алюминиевой пудры и грязи, то необходимости в промывке нет, т. к. вся грязь задержалась в теплообменнике конденсатора и фильтре. Поэтому если меняете компрессор, то, из личного опыта на Приусе, рекомендую сразу поменять теплообменник конденсатора в сборе с фильтром. Остаётся проверить трубку от компрессора к конденсатору и, в случае необходимости промыть и продуть сухим азотом (не воздухом). Воздух и влага антогонисты системе кондиционирования. Конденсатор, если он совсем не «китайский», всегда идёт в сборе с фильтром-осушителем и заправлен сухим азотом под давлением.»
После заправки рекомендую для избавления от запахов и бактерий очистить испаритель и поставить угольный фильтр. Процедура описана в TSB за 10 ноября 2016 T-SB-0142-13 HVAC Odor Maintenance.
____________________________________________
Далее и до конца необязательная информация для общего развития:
Распределение масла по системе.
Нарушение герметичности инвертора компрессора и выход его из строя.
Схемы узла 87-18 HEATING & AIR CONDITIONING — COOLER PIPING:
Европа, ВБ, Австралия, Тайланд. Крепеж может быть местный:
Полный размер
Япония, Сев. Америка:
Полный размер
Новый Plug-In, обновилось два вида болтов и изменилась траектория пунктирной линии, видимо это самая свежая схема:
Полный размер
Китай, как видим, крепеж полностью другой:
Полный размер
Старый Plug-In с тепловым насосом:
Полный размер
Схема узла 87-19 HEATING & AIR CONDITIONING — COMPRESSOR:
maslyakr написал: fermer написал: maslyakr написал: fermer написал: maslyakr написал: Сейчас поеду на скан… Это самое правильное решение Выдало ошибку P0aa6, перд этим помыл салон откручивал ввб что под ней пыль протереть(( и мыл подкапотное У вас идет утечка высокого напряжения на корпус. Чтобы локализовать (хоть примерно) место утечки надо считать подкод к этой ошибке. Если это будет 611 подкод — то проблема в компрессоре, если 612 — то в ВВБ, а если 526, то искать придется долго. Я это уже понял((, подскажите сканер Bosch считает подкод или только тойотовский, а вообще какой может? Вчера разбирал ВВб, зачищал все контакты, не помогло. А где стоит компрессор? Я думаю просто где то вода в фишку попала и плохой контакт…
1. БОШ не считает. |
|
с уважением, Сергей Николаевич. |
fermer написал: maslyakr написал: fermer написал: maslyakr написал: fermer написал: maslyakr написал: Сейчас поеду на скан… Это самое правильное решение Выдало ошибку P0aa6, перд этим помыл салон откручивал ввб что под ней пыль протереть(( и мыл подкапотное У вас идет утечка высокого напряжения на корпус. Чтобы локализовать (хоть примерно) место утечки надо считать подкод к этой ошибке. Если это будет 611 подкод — то проблема в компрессоре, если 612 — то в ВВБ, а если 526, то искать придется долго. Я это уже понял((, подскажите сканер Bosch считает подкод или только тойотовский, а вообще какой может? Вчера разбирал ВВб, зачищал все контакты, не помогло. А где стоит компрессор? Я думаю просто где то вода в фишку попала и плохой контакт…
1. БОШ не считает.
1.А какой нибудь может кроме Тойоты считать?? |
|
|
maslyakr написал:
1.А какой нибудь может кроме Тойоты считать??
Течстрим и шнурок. |
|
с уважением, Сергей Николаевич. |
fermer написал: maslyakr написал:
1.А какой нибудь может кроме Тойоты считать??
Течстрим и шнурок. Сделал скан тойота-центре, как я и думал подкод 526((( После этого, скинул разъем с кондера — ошибка висит. отключил контакты с инвертора — ошибка ушла!!)) |
|
|
maslyakr написал: fermer написал: maslyakr написал:
1.А какой нибудь может кроме Тойоты считать??
Течстрим и шнурок. Сделал скан тойота-центре, как я и думал подкод 526((( После этого, скинул разъем с кондера — ошибка висит. отключил контакты с инвертора — ошибка ушла!!))
С 526 подкодом без хорошего мегомметра проблему не найти |
|
с уважением, Сергей Николаевич. |
fermer написал: maslyakr написал: fermer написал: maslyakr написал:
1.А какой нибудь может кроме Тойоты считать??
Течстрим и шнурок. Сделал скан тойота-центре, как я и думал подкод 526((( После этого, скинул разъем с кондера — ошибка висит. отключил контакты с инвертора — ошибка ушла!!))
С 526 подкодом без хорошего мегомметра проблему не найти Как понять тогда что ошибка ушла?? |
|
maslyakr написал: Как понять тогда что ошибка ушла?? Очень просто: P0AA6 больше не будет появляться |
|
с уважением, Сергей Николаевич. |
сегодня заехала машинка с ошибкой Р0А84-123. |
|
olegx5555 написал: сегодня заехала машинка с ошибкой Р0А84-123.
Если вентилятор наглухо не забит грязью (а это сразу чувствуется по специфическому запаху в машине), то он тут абсолютно ни при чем |
|
с уважением, Сергей Николаевич. |
30. |
|
olegx5555 написал: 30. Суть фразы в том, что приговаривают исправный вентилятор на замену. |
|
с уважением, Сергей Николаевич. |
Время покажет. Вернется — отпишусь |
|
Чтоб не создавать новую тему — отпишусь тут. Приус 30. 10 год, правый руль. |
|
energy_6041 написал: Чтоб не создавать новую тему — отпишусь тут. Приус 30. 10 год, правый руль.
Не обижайтесь, но меня до глубины души удивляют такие, как вы владельцы машин! |
|
с уважением, Сергей Николаевич. |
fermer написал: energy_6041 написал: Чтоб не создавать новую тему — отпишусь тут. Приус 30. 10 год, правый руль.
Не обижайтесь, но меня до глубины души удивляют такие, как вы владельцы машин! Спасибо уважаемый ответчик. Я разделяю с Вами Ваше недоумение, но вы же знаете нашего человека. Надежда на чудо в нас не умирает. В ближайшее время сделаю диагностику и отпишусь. Мне просто было интересно, бывали ли у кого-то такие выкрутасы с поднятием оборотов. |
|
energy_6041 написал: Спасибо уважаемый ответчик. Я разделяю с Вами Ваше недоумение, но вы же знаете нашего человека. Надежда на чудо в нас не умирает. В ближайшее время сделаю диагностику и отпишусь. Мне просто было интересно, бывали ли у кого-то такие выкрутасы с поднятием оборотов. Можно процентов на 80 сказать, что у вас неисправна ВВБ. |
|
с уважением, Сергей Николаевич. |
добрый день. забыл отписатся по ошибке P0A84. |
|
Всем привет! |
|
По моему вышел с ключом в кармане а зажигание не выключил |
|
Спасибо сказали: лелик |
лелик написал: Всем привет! Вы вышли с ключом из заведенной машины. Она сигналом напоминает вам, что ее нужно заглушить. |
|
с уважением, Сергей Николаевич. Спасибо сказали: лелик |