PROGRAMMER LCD DISPLAY
CODE
EFFECT OF FAULT
18
Severe B+ Overvoltage
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
Controller Overtemp Cutback
22
Reduced drive and brake
torque.
23
B+ Undervoltage Cutback
Reduced drive torque.
24
B+ Overvoltage Cutback
Reduced brake torque.
Note: This fault is declared
only when the controller is
running in regen.
25
+5V Supply Failure
None, unless a fault action
is programmed in VCL.
26
Digital Out 6 Open/Short
Digital Output 6 driver
will not turn on.
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual,
2 4 N O V E M B E R 2 0 1 5
Table 6 TROUBLESHOOTING CHART, cont’d
POSSIBLE CAUSE
1. See Monitor menu » Battery:
Capacitor Voltage.
2. Battery menu parameters are
misadjusted.
3. Battery resistance too high for given
regen current.
4. Battery disconnected while regen
braking.
1. See Monitor menu » Controller:
Temperature.
2. Controller is performance-limited
at this temperature.
3. Controller is operating in an extreme
environment.
4. Excessive load on vehicle.
5. Improper mounting of controller.
1. Normal operation. Fault shows that
the batteries need recharging.
Controller is performance limited
at this voltage.
2. Battery parameters are misadjusted.
3. Non-controller system drain on battery.
4. Battery resistance too high.
5. Battery disconnected while driving.
6. See Monitor menu » Battery:
Capacitor Voltage.
7. Blown B+ fuse or main contactor
did not close.
1. Normal operation. Fault shows that
regen braking currents elevated the
battery voltage during regen braking. FET bridge enabled.
Controller is performance limited
at this voltage.
2. Battery parameters are misadjusted.
3. Battery resistance too high for given
regen current.
4. Battery disconnected while regen braking.
5. See Monitor menu » Battery:
Capacitor Voltage.
1. External load impedance on the
+5V supply (pin 26) is too low.
2. See Monitor menu » outputs:
5 Volts and Ext Supply Current.
1. External load impedance on Digital
Output 6 driver (pin 19) is too low.
30
os
9 — DIAGNOSTICS & TROUBLESHOOTING
SET/CLEAR CONDITIONS
Set: Capacitor bank voltage exceeded
the Severe Overvoltage limit (see page 64)
with FET bridge enabled.
Clear: Bring capacitor voltage below
Severe Overvoltage limit, and then
Set: Heatsink temperature exceeded 85°C.
Clear: Bring heatsink temperature below
85°C.
Set: Capacitor bank voltage dropped below
the Undervoltage limit (see page 64) with
the FET bridge enabled.
Clear: Bring capacitor voltage above the
Undervoltage limit.
Set: Capacitor bank voltage exceeded the
Overvoltage limit (see page 64) with the
Clear: Bring capacitor voltage below the
Overvoltage limit.
Set: +5V supply (pin 26) outside the
+5V±10% range.
Clear: Bring voltage within range.
Set: Digital Output 6 (pin 19) current
exceeded 15 mA.
Clear: Remedy the overcurrent cause
and use the VCL function
Set_DigOut()
to turn the driver on again.
137
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
Manual
DUAL DRIVE OPERATION
for Controller Models
1232E / 34E / 36E / 38E / 39E
1232SE / 34SE / 36SE
and
» Software Version OS 30.0 «
Read Instructions Carefully!
Specifications are subject to change without notice.
© 2016 Curtis Instruments, Inc. ® Curtis is a registered trademark of Curtis Instruments, Inc.
© The design and appearance of the products depicted herein are the copyright of Curtis Instruments, Inc.
Curtis Instruments, Inc.
200 Kisco Avenue
Mt. Kisco, NY 10549
www.curtisinstruments.com
/
,
53134
53133
OS30 3/1/16
DD
DD
Summary of Contents for Curtis 1232E
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
Manual
DUAL DRIVE OPERATION
for Controller Models
1232E / 34E / 36E / 38E / 39E
1232SE / 34SE / 36SE
and
» Software Version OS 30.0 «
Read Instructions Carefully!
Specifications are subject to change without notice.
© 2016 Curtis Instruments, Inc. ® Curtis is a registered trademark of Curtis Instruments, Inc.
© The design and appearance of the products depicted herein are the copyright of Curtis Instruments, Inc.
Curtis Instruments, Inc.
200 Kisco Avenue
Mt. Kisco, NY 10549
www.curtisinstruments.com
/
,
53134
53133
OS30 3/1/16
DD
DD
Summary of Contents for Curtis 1232E
Реклама:
Хочешь стать куратором любимой темы?
- Электротранспорт »
- Ездим на батарейках! »
- Электромобили (Модераторы: oldpilot, Surf_el, stels) »
- Все о контроллерах curtis
Комментарии к новостям
Тема: Все о контроллерах curtis
Прочитано 55507 раз
0 Пользователи и 1 Гость просматривают эту тему.
03 Ноя 2020 в 13:34
Ответ #90
Otard
Russia, Krasnodar
Сообщений: 1
Есть гольфмобиль на контроллере 1236-5401.
У него проблема — самопроизвольно едет вперёд. Даже удерживая педаль тормоза он пытается двигаться, причём амперметр на приборной панели показывает всё больше увеличивающийся ток.
Ошибок нет.
Контроллер помирает?
09 Июл 2021 в 18:57
Ответ #91
Гольфкар Russia
Москва — Московская область — Россия
Сообщений: 4
Здравствуйте…есть программа и переходник…всегда подключался к контроллерам куртис 1266,1232,1236,1520., и другим но тут не смог подключиться к 1243 причём к нескольким….версия программы старая может быть
« Последнее редактирование: 10 Июл 2021 в 11:10 от Гольфкар Russia »
10 Июл 2021 в 11:23
Ответ #92
Гольфкар Russia
Москва — Московская область — Россия
Сообщений: 4
Evares, Здравствуйте…есть программа и переходник…по куртису….всегда подключался к разным контроллерам 1266,1236,1520 и т.д. Но вчера не смог подключиться к нескольким 1243 грузит подключение бесконечность
16 Мар 2022 в 16:07
Ответ #93
alchemistt
43rus, Киров
Сообщений: 1
всем привет
подскажите, на радиатор наносится что-то под корпуса транзисторов и диодов? Там как будто остатки какой-то смазки, похожей на ЦИАТИМ, например
Модель 1221-7405 (хотя это сути не меняет, я думаю)
16 Мар 2022 в 21:39
Ответ #94
Владимир_87
Владикавказ — Северная Осетия — Россия
Сообщений: 155
радиатор наносится что-то под корпуса транзисторов и диодов
Привет, термопаста
09 Июл 2022 в 09:31
Ответ #95
jonn2096
Волгоград — Волгоградская область — Россия
Сообщений: 2
Здравствуйте. Нужна помощь в оживлении контроллера Curtis 1234-5371 . Установлен на электропогрузчике TFN. На дисплее ошибка, на самом контроллере мигают светодиоды, по мограниям коды 5.2 и 5.1, в дисплее читал ошибки контроллера : Can communications fault, и Pdo fault. На нажатия педали не реагирует.
21 Июл 2022 в 23:37
Ответ #96
jonn2096
Волгоград — Волгоградская область — Россия
Сообщений: 2
Здравствуйте. Нужна помощь в оживлении контроллера Curtis 1234-5371 . Установлен на электропогрузчике TFN. На дисплее ошибка, на самом контроллере мигают светодиоды, по мограниям коды 5.2 и 5.1, в дисплее читал ошибки контроллера : Can communications fault, и Pdo fault. На нажатия педали не реагирует.
Есть изменения. По кан связи с дисплеем не было из-за неисправной микросхемы — кан транслятора. Заменил, связь появилась, но только погрузчик всё равно не ехал. Покопавшись в настройках добился, чтобы погрузчик поехал, но вот только мотор раскручивается на максимум, и не останавливается пока не выключишь питание, также он раскручивается, если вывешенное колесо раскрутить, причём не нажимая педаль акселератора, и рычаг направления в нейтральном положении. Заметил, что мотор поддаётся управлению, только если очень — очень плавно нажимать педаль, а также её отпускать тоже плавно, чуть быстрее нажмёшь или отпустишь и мотор выходит из под контроля. Что это может быть?
23 Авг 2022 в 09:31
Ответ #97
Виталий13
Сообщений: 1
Всем доброго времени суток. ОЧЕНЬ нужен ваш совет!)
Я приобрёл технику с установленным в ней контроллером Curtis 1740-2201.
Есть задача добавить к уже имеющемуся пульту 1742, простые(замыкание контактов) кнопки (вперёд, назад, лево, право. С возможностью их совмещения).
Скажите пожалуйста, возможно ли это сделать?
ссылка
- Электротранспорт »
- Ездим на батарейках! »
- Электромобили (Модераторы: oldpilot, Surf_el, stels) »
- Все о контроллерах curtis
Автор | Сообщение | ||
Асен Стаменов |
|
||
Зарегистрирован: 25 окт 2016, 14:23
|
|||
|
|||
Admin |
|
||
Зарегистрирован: 02 окт 2010, 11:36
|
Асен, мы рады, что Вы и Ваша команда приняли участие в работе форума. Надеемся на плодотворное сотрудничество в развитии и продвижении электротранспорта. _________________ |
||
|
|||
LICC |
|
||
Форумчанин
Зарегистрирован: 25 сен 2011, 12:43
|
Привет, Асен. Вопрос такого плана: |
||
|
|||
Асен Стаменов |
|
||
Зарегистрирован: 25 окт 2016, 14:23
|
|||
|
|||
ЛСН |
|
||
Гуру
Зарегистрирован: 09 окт 2012, 23:03
|
Вопросы по контроллеру Curtis 1232 SE можно здесь задавать или со временем будет открыта отдельная тема? |
||
|
|||
Dyunov |
|
||
Гуру
Зарегистрирован: 02 окт 2010, 12:37 Cпасибо сказано: 950
|
На форуме электротранспорт.ru сложилось устойчивое мнение, что контроллеры Curtis вычисляют вращающий момент с очень низкой точностью не выше +-50%. |
||
|
|||
Асен Стаменов |
|
||
Зарегистрирован: 25 окт 2016, 14:23
|
Здравствуйте, |
||
|
|||
Dyunov |
|
||
Гуру
Зарегистрирован: 02 окт 2010, 12:37 Cпасибо сказано: 950
|
Асен, возможна ли реализация алгоритма взаимодействия контроллера с БМС (блоком мониторинга состояния ячеек аккумуляторной батареи), приведенного в прикреплённом файле. Вложение:
|
||
|
|||
Асен Стаменов |
|
||
Зарегистрирован: 25 окт 2016, 14:23
|
Привет, |
||
|
|||
Dyunov |
|
||
Гуру
Зарегистрирован: 02 окт 2010, 12:37 Cпасибо сказано: 950
|
Его можно было бы не интегрировать, а подключать через USB разъём адаптера? |
||
|
|||
|
Кто сейчас на конференции
Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 1 |
Вы не можете начинать темы |
Неисправность плавающая . При повороте ручки руля в крайнее левое или правое положение штабелер резко стопорит . В ходе
программной диагностики контроллера CURTIS 1232 и электропроводки , выявлено ошибка внутреннего софта контроллера и ошибка энкодера . Ошибки были
удалены после чего штабелер опять был запущен. И те же самые симптомы и ошибки . Предварительно клиенту было рекомендовано
заменить энкодер двигателя .
- Home
- Brands
- Curtis
- Controller
- 1232E
- Manual
Manual for Curtis 1232E Controller (30 pages)
Specifications:1884/1884659-1232e.pdf file (07 Mar 2023) |
Read Curtis 1232E PDF Manual Online:
Accompanying Data:
Curtis 1232E Controller PDF Manual (Updated: Tuesday 7th of March 2023 04:27:17 AM)
Rating: 4.8 (rated by 59 users)
Compatible devices: 1253, 1222, MultiMode 1228, 1226, 1313, 1212, 1355, MultiMode 1214-8.
Recommended Documentation:
Text of Manual
(Ocr-Read Version Summary of Contents, UPD: 07 March 2023)
-
22, 7 — TROUBLESHOOTING Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC pg. 20 Table 2 DUAL DRIVE TROUBLESHOOTING CHART CODE PROGRAMMER LCD DISPLAY EFFECT OF FAULT POSSIBLE CAUSE SET / CLEAR CONDITIONS 12 Controller Overcurrent ShutdownMotor; ShutdownMainContactor; ShutdownEMBrake; ShutdownThrottle; FullBrake. Other controller: Same …
-
14, 5 — DUAL DRIVE SETUP Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC pg. 12 5 — DUAL DRIVE SETUP First you should complete the setup procedures for the two controllers you are using as outlined in the 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE os31 manuals.. en proceed with these Dual Drive setup procedures. Bef…
-
12, 4 — DETERMINING CRITICAL ANGLE AND INNER WHEEL SPEED Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC pg. 10 Figure 3 Typical 3-wheel Dual Drive vehicle geometry. W T T W A Figure 4 Typical articulated steering Dual Drive vehicle geometry. W T T W A
… -
25, 7 — TROUBLESHOOTING pg. 23 Return to TOC Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 CODE PROGRAMMER LCD DISPLAY EFFECT OF FAULT POSSIBLE CAUSE SET / CLEAR CONDITIONS 35 PD Open/Short ShutdownPD. Other controller: Same effects as this controller. 1. Open or short on driver load. 2. Dirty connector pins. 3. Bad crimps or faulty wiring. Set: …
-
11, 4 — DETERMINING CRITICAL ANGLE AND INNER WHEEL SPEED pg. 9 Return to TOC Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 4 — DETERMINING CRITICAL ANGLE AND INNER WHEEL SPEED e rst step in setting up the Dual Drive feature is to determine the values of two parameters: Critical Angle, the angle at which the vehicle pivots with its inner whee…
-
30, 7 — TROUBLESHOOTING Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC pg. 28 CODE PROGRAMMER LCD DISPLAY EFFECT OF FAULT POSSIBLE CAUSE SET / CLEAR CONDITIONS 89 Motor Type Fault ShutdownMotor; ShutdownMainContactor; ShutdownEMBrake; ShutdownThrottle; FullBrake. Other controller: Same effects as this controller. 2. The Motor_Type pa…
-
8, Curtis 1232E 3 — PROGRAMMABLE PARAMETERS Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC pg. 6 DUAL DRIVE MENU PARAMETER ALLOWABLE RANGE DESCRIPTION Dual Motor Enable |Dual_Motor_Enable |OptionBits4 [Bit 2] 0x306D 0x00 On / Off On / Off To turn on the Dual Drive feature, set this parameter On in both controllers. Dual Motor S…
-
13, Curtis 1232E 4 — DETERMINING CRITICAL ANGLE AND INNER WHEEL SPEED pg. 11 Return to TOC Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 e inner wheel speed is determined by the outer wheel speed, as shown in Figure 5. It decreases from 100% of the outer wheel speed to zero at the programmed critical angle, and then from zero to the programmed Inner W…
-
16, Curtis 1232E 6 — VEHICLE CONTROL LANGUAGE & CAN Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC pg. 14 6 — VEHICLE CONTROL LANGUAGE & CAN e motor command diagrams for the Dual Drive controllers are shown in Figure 7a (for the master controller, which controls the Le traction motor) and Figure 7b (for the slave controller, w…
-
5, 2 — WIRING pg. 3 Return to TOC Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 e master controller is wired to all the components except those related to the Right motor and the steering pot. Figure 2b Basic wiring diagram for master controller, Dual Drive operation. SWITCH 16 J1-14 SWITCH 8 J1-33 REVERSE SWITCH 7 J1-22 FORWARD SWITCH 6 J1-12 SWI…
-
9, 3 — PROGRAMMABLE PARAMETERS pg. 7 Return to TOC Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 DUAL DRIVE MASTER MENU PARAMETER ALLOWABLE RANGE DESCRIPTION Steer Angle Max (deg) Dual_Steer_Angle_Max 0x38A3 0x00 45 – 90 deg 45 – 90 Set this to the maximum steer angle that is physically possible on the vehicle. (Steer Angle is the…
-
Curtis 1232E User Manual
-
Curtis 1232E User Guide
-
Curtis 1232E PDF Manual
-
Curtis 1232E Owner’s Manuals
Curtis 1232E Recommended Instructions:
HX-Z10C, QB325W, NN-830012-S2, FM CORDLESS SPEAKER BC8210, KMR 330 — Marine CD Receiver
-
Renesas
TPS-1
All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp. through various means, including the Renesas Electronics Corp …
TPS-1 91
-
Siemens
SINUMERIK 840D sl
Valid forControlSINUMERIK 840D slSINUMERIK 840D sl (export version)DriveSINAMICS S120Software version1.3.203.06 EditionSINUMERIK Safety IntegratedSINUMERIK 840D sl/SINAMICS S120Function ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction ManualFunction …
SINUMERIK 840D sl 508
-
Mitsubishi Electric
MELSEC FX Series
MELSEC FX SeriesProgrammable Logic ControllersUser’s ManualCommunications ModulesRS-232C, RS-485, RS-422INDUSTRIAL AUTOMATIONMITSUBISHI ELECTRICMITSUBISHI ELECTRICArt. no.: 07014315 04 2003JY992D69901Version E …
MELSEC FX Series 162
-
Texmate
Tiger 380 Series
1PROGRAMMING CODE SHEETTTiiggeerr 338800 SSeerriieessCode blankingCode blanking blanks out all function codesnot required by the application. This meansthat specific procedures such as recalibra-tion and setpoint reprogramming can beachieved in a few simple steps from thefront panel buttons.To turn code blanking and macro settingsOFF, carry out the Code Blanking andMacro Check on Page 3.Dis …
Tiger 380 Series 22
-
Danfoss
FCM305 56
FCM 300 SeriesMG.03.B6.2G — VLT is a registered Danfoss trademarkTable of ContentsChapter 1 SafetyChapter 1 SafetyChapter 1 SafetyChapter 1 SafetyChapter 1 Safety……………………………………………………………………………………………………………………………………………………………………………………… …
FCM305 56 132
-
Emerson
Fisher FIELDVUE DVC6200 SIS
www.Fisher.comUse these instructions to mount a FisherR FIELDVUEtDVC6200 or DVC2000 digital valve controller on Fisher585C/585CR size 25 actuators with or without handjackactuators.WARNINGAvoid personal injury or propertydamage from sudden release of processpressure or bursting of parts. Beforeperforming any maintenance operations:D Always wear protective clothing,gloves, and eyewear.D Do not rem …
Fisher FIELDVUE DVC6200 SIS 2
-
Kelly
KLS4840D
Kelly KLS-D Brushless Motor Controller User’s Manual V1.5.02Kelly KLS-D Brushless MotorController User’s ManualDevices Supported:Rev.1.5.02October.2015KLS4840DKLS7240DKLS4850DKLS7250DKLS6040DKLS7275DKLS6050D …
KLS4840D 22
-
ComAp
InteliLite NT MRS19
InteliLite NT MRS19 Quick Start Guide This guide was created to provide instruction on some of the most common tasks involved when working with the IL-NT-MRS19. This Guide includes information on; 1. Where to get the Correct Software and Manuals? 2. How to Connect and Save the Archive? 3. Procedure for Replacing a Controller 4. Upgrading Controller F …
InteliLite NT MRS19 14
-
Calsense
400 Series
® WIND GAGE SETUP making since 1986 water work WIND GAGE ET2000 (400 SERIES) WIND GAGE 110 984856732 1 STOP – The STOP key will stop any currently running Scheduled watering Cycle, Manual Cycle, T …
400 Series 4
-
Carel
DN33 Universale Series
220240VOUT 1PROBEDIG.2 COM. DIG.10POWER24V1 2 39 8 7SERIALLINKc~~NTCp2 p1220240V024V1 2 312 11 10 9 8 7c~~cNTCp2 p1POWERPROBEOUT 2OUT 1SERIALLINKDIG.2 COM. DIG.1OUT 1OUT 3OUT 2OUT 4PROBEPOWERDIG.2 COM. DIG.112-24 V3 VA1 2 313 145 6 7 8 9 10 11 12SERIALLINK- ++ -+ — + -+ -com. NTCp2 p1OUT 1OUT 3OUT 2OUT 4PROBEPOWERDIG.2 COM. …
DN33 Universale Series 2
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
- Home
- Forums
- Design & Engineering
if someone had a this problem, I read the manual and did not understand how handle this, ask for help, explain please in simple language how to eliminate it.
Any help
- Posted
11 Apr 2016 05:24 - Discussion started by
alexandr_k - Ukraine, Ukraine
Showing items 1 — 3 of 3 results.
Sort messages by:
Thank you for helps but I do not understand up to the end,
possible each manufacturer for yourself has written its own code
hyster P2,0 SE serial B978T01867M
AC Motor Controller 24v
part num. 8815222
model 1232E-2223
serial n. 14106c 024241
- Posted
11 Apr 2016 23:39 - Modified
12 Apr 2016 04:54
by
poster - Reply by
alexandr_k - Ukraine, Ukraine
these are often codes like the brush wear indicators, or motor over heat indicators. but Stam is correct, they are inputs supplied by the customer.
- Posted
11 Apr 2016 21:35 - Reply by
edward_t - South Carolina, United States
«it’s not rocket surgery»
Mfg. Specific codes
Need the model and serial from the truck it is out of. Trucks book will tell you not curtis book.
- Posted
11 Apr 2016 19:38 - Modified
11 Apr 2016 19:39
by
poster - Reply by
stam - Ontario, Canada
Having trouble using the Discussion Forums? Contact us for help.
Forkliftaction.com accepts no responsibility for forum content and requires forum participants to adhere to the rules. Click here for more information.
Реклама:
Хочешь стать куратором любимой темы?
- Электротранспорт »
- Ездим на батарейках! »
- Электромобили (Модераторы: oldpilot, Surf_el, stels) »
- Все о контроллерах curtis
Комментарии к новостям
Тема: Все о контроллерах curtis
Прочитано 58039 раз
0 Пользователи и 1 Гость просматривают эту тему.
03 Ноя 2020 в 13:34
Ответ #90
Otard
Russia, Krasnodar
Сообщений: 1
Есть гольфмобиль на контроллере 1236-5401.
У него проблема — самопроизвольно едет вперёд. Даже удерживая педаль тормоза он пытается двигаться, причём амперметр на приборной панели показывает всё больше увеличивающийся ток.
Ошибок нет.
Контроллер помирает?
09 Июл 2021 в 18:57
Ответ #91
Гольфкар Russia
Москва — Московская область — Россия
Сообщений: 4
Здравствуйте…есть программа и переходник…всегда подключался к контроллерам куртис 1266,1232,1236,1520., и другим но тут не смог подключиться к 1243 причём к нескольким….версия программы старая может быть
« Последнее редактирование: 10 Июл 2021 в 11:10 от Гольфкар Russia »
10 Июл 2021 в 11:23
Ответ #92
Гольфкар Russia
Москва — Московская область — Россия
Сообщений: 4
Evares, Здравствуйте…есть программа и переходник…по куртису….всегда подключался к разным контроллерам 1266,1236,1520 и т.д. Но вчера не смог подключиться к нескольким 1243 грузит подключение бесконечность
16 Мар 2022 в 16:07
Ответ #93
alchemistt
43rus, Киров
Сообщений: 1
всем привет
подскажите, на радиатор наносится что-то под корпуса транзисторов и диодов? Там как будто остатки какой-то смазки, похожей на ЦИАТИМ, например
Модель 1221-7405 (хотя это сути не меняет, я думаю)
16 Мар 2022 в 21:39
Ответ #94
Владимир_87
Владикавказ — Северная Осетия — Россия
Сообщений: 155
радиатор наносится что-то под корпуса транзисторов и диодов
Привет, термопаста
09 Июл 2022 в 09:31
Ответ #95
jonn2096
Волгоград — Волгоградская область — Россия
Сообщений: 2
Здравствуйте. Нужна помощь в оживлении контроллера Curtis 1234-5371 . Установлен на электропогрузчике TFN. На дисплее ошибка, на самом контроллере мигают светодиоды, по мограниям коды 5.2 и 5.1, в дисплее читал ошибки контроллера : Can communications fault, и Pdo fault. На нажатия педали не реагирует.
21 Июл 2022 в 23:37
Ответ #96
jonn2096
Волгоград — Волгоградская область — Россия
Сообщений: 2
Здравствуйте. Нужна помощь в оживлении контроллера Curtis 1234-5371 . Установлен на электропогрузчике TFN. На дисплее ошибка, на самом контроллере мигают светодиоды, по мограниям коды 5.2 и 5.1, в дисплее читал ошибки контроллера : Can communications fault, и Pdo fault. На нажатия педали не реагирует.
Есть изменения. По кан связи с дисплеем не было из-за неисправной микросхемы — кан транслятора. Заменил, связь появилась, но только погрузчик всё равно не ехал. Покопавшись в настройках добился, чтобы погрузчик поехал, но вот только мотор раскручивается на максимум, и не останавливается пока не выключишь питание, также он раскручивается, если вывешенное колесо раскрутить, причём не нажимая педаль акселератора, и рычаг направления в нейтральном положении. Заметил, что мотор поддаётся управлению, только если очень — очень плавно нажимать педаль, а также её отпускать тоже плавно, чуть быстрее нажмёшь или отпустишь и мотор выходит из под контроля. Что это может быть?
23 Авг 2022 в 09:31
Ответ #97
Виталий13
Сообщений: 1
Всем доброго времени суток. ОЧЕНЬ нужен ваш совет!)
Я приобрёл технику с установленным в ней контроллером Curtis 1740-2201.
Есть задача добавить к уже имеющемуся пульту 1742, простые(замыкание контактов) кнопки (вперёд, назад, лево, право. С возможностью их совмещения).
Скажите пожалуйста, возможно ли это сделать?
ссылка
29 Янв 2023 в 20:41
Ответ #98
Mobimaster
Сообщений: 1
Приветствую, нужна помощь с curtis 1243 нет хода ни вперед ни назад, ошибка 2.3 подскажите пожалуйста возможные причины неисправности.
- Электротранспорт »
- Ездим на батарейках! »
- Электромобили (Модераторы: oldpilot, Surf_el, stels) »
- Все о контроллерах curtis