PURPOSE
Programmable control timer is used to time control the devices in home or
industrial automation systems according to an individual time program set by
the user.
OPERATION
Timer activates and deactivates the device or electrical circuit on the
programmed hours in cycles: daily, weekly, working days (Mon-Fri)
or weekend (Sat, Sun). The timer has two independently programmable
channels.
OPERATING MODES AND FUNCTIONS
CHANNEL – program line with individual entries for ON-OFF COMMANDS,
which controls its own contact for enabling the receiver.
ON-OFF COMMAND – program entry for enabling or disabling the receiver.
500 MEMORY CELLS – memory for individual program entries that allows to
program 250 pairs of ON-OFF COMMANDS.
AUTOMATIC MODE — operation by ON-OFF COMMANDS programmed by the
user in the timer memory [highlighted
icon on display]
MANUAL MODE — [ON] permanently closed contact (position 1-5) or [OFF]
permanently open contact (position 1-6) when the AUTOMATIC MODE is off
[no
icon on display]
CYCLE — adjustable, weekly cycle (7 days from Monday to Sunday) of the
receiver switching in accordance with the programmed ON-OFF COMMANDS:
* single day of the week: Mo; Tu; We; Th; Fr; Sa or Su.
* working days: Mo Tu We Th Fr (Monday to Friday).
* weekend: Sa Su (Saturday and Sunday)
* daily: Mo Tu We Th Fr Sa Su (Monday to Sunday).
AUTOMATIC TIME CHANGE — change from winter time to summer time with
options to change automatically or not. User can set the time zone so that the
switching time is consistent with the local time
DATE PREVIEW — the ability to preview the set date (OK.)
CURRENT PROGRAM PREVIEW – pressing the +/- keys in the date preview
mode displays information about the number and details of the current
program.
NFC WIRELESS COMMUNICATION — wirelessly read and write timer
configuration from an Android phone equipped with the NFC module.
PCZ Konfigurator APP — free application for Android mobile phones and
tablets equipped with the NFC module for wireless communication.
Features: · timer configuration in Offline mode (without the connection with
the PCZ-521 timer);
· read and write the configuration of the controller;
· quick programming of multiple controllers using a single configuration;
· read and write the configuration from and to a file;
· sharing the configuration via e-mail, Bluetooth, network drives…
· identification of the connected timer and the ability to name individual
devices;
· automatic backups of the configuration. Along with a unique identifier for
each timer, user can easily restore previous configuration;
· set the time and date according to the clock in mobile phone;
The app is available on Google Play!
CLOCK TIME CORRECTION – set monthly adjustment of the seconds of the
system clock.
BATTERY INDICATOR — the controller comes with built-in control system of the
backup timer battery used in case of main power supply failure. If the battery
is low, user will receive information that the battery needs to be replaced.
Battery life depends on the ambient temperature and the degree of the
battery wear.
-1-
LCD BRIGHTNESS ADJUSTMENT — change the contrast of the display to get
aclear LCD read-out from different viewing angles.
POLAND
RELAY STATE MEMORY — the relay state in manual mode will be remembered
even after power supply failure.
DISPLAY AND CONTROL PANEL DESCRIPTION
Mo T
W
T
F
R
S
A
S
U
E
H
DATE AND TIME /
/ PROGRAM ENTRIES
ş
ş
1
ON
2
OFF
MODE INDICATOR /
/ AUTOMATIC MODE
OK
MENU
+
Mo – Monday; Tu – Tuesday; We – Wednesday; Th – Thursday; Fr – Friday;
Sa – Saturday; Su – Sunday.
FUNCTION KEYS DESCRIPTION
MENU:
— enter the program menu
— return to the previous position (back).
OK:
— move to the next setting
— accept setting
— preview of the date
+ [Plus]:
— change the setting by one position up for the selected programming option
(holding down the button continuously changes the setting by one position
up in a loop)
— in MANUAL MODE: permanent ON and OFF contact switching
— [Minus]:
— change in the setting by one position down for the selected programming
option (holding down the button continuously changes the setting by one
position down in a loop)
— in MANUAL MODE: permanent ON and OFF contact switching
PROGRAMMING
1. START
1.1 Connect the power supply.
1.2 The timer will start at the root level and the display will show selected
hour.
Mo
T
U
W
E
T
H
F
R
S
A
S
U
1
OFF
In the absence of any program entries, timer will automatically run in manual
mode. If the previous entries are present, timer will execute the program.
To erase all previous settings, see section 5.6.
1.3 Set individual timer program with internal configuration menu or by using
the «PCZ Konfigurator» app for mobile devices.
2. DATE
Press MENU. The timer will enter program menu. Using the +/- buttons
select the date setting mode [date]
Confirm with OK.
-2-
Timer will show settings for the next parameters: year, month, and day. Use
the +/- keys to set the parameters; move to the next parameter with the OK
button. Go back to the previous item by pressing MENU.
Press OK to accept date setting. The timer will automatically exit from the
DAYS OF THE WEEK /
U
/ CYCLE
date setting mode and go to the program menu.
CHANNEL NUMBER
The date setting is tantamount to time determination: winter or summer.
In Poland, the time change from winter to summer is done automatically at
ON
OFF
night, on the last Sunday of March at 2.00 AM (by adding one hour to the
current time). Time change from summer to winter is done automatically at
INDICATION OF CONTACT
night, on the last Sunday of October at 3.00 AM (by subtracting one hour
POSITION
from the current time).
PLEASE NOTE!
The automatic time change can be turned off (see section 5.1).
3. TIME
Press MENU. The timer will enter the program menu. Using the +/- buttons
select the mode for time setting [hour]
Timer will show settings for the next parameters: hour and minutes. Set the
parameters with the +/- buttons. Move to the next parameter with the OK
button. Go back to the previous item by pressing MENU.
Press OK to accept time entry. The timer will automatically exit from the date
setting mode and go to the program menu.
4. CHANNEL – Selecting a channel number and setting its parameters
Press MENU. The clock will enter the program menu. Using +/- buttons select
the mode for the date setting: «Chn 1» or «Chn 2».
Select channel 1 or 2, and accept with OK button.
Timer will show the submenu of the selected channel parameter settings:
on-off commands, edit, delete and mode select.
Select the desired entry with the +/- buttons. Open the desired item with OK
button.OK. Press MENU button to return to the main MENU.
4.1 ON-OFF COMMAND — setting the parameters
Using the +/- buttons select the mode for the date setting [prog].
Press OK to accept. The clock will enter the memory cell number selecting
mode. The display will automatically show the number of the first empty
memory cell.
Press OK to accept (or select another number using the +/- keys). Clock will
enter the single ON-OFF COMMAND parameters setting mode.
A. Operation cycle
Set OPERATION CYCLE using the +/- keys:
* single day of the week: Mo; Tu; We; Th; Fr; Sa or Su.
* working days: Mo Tu We Th Fr (Monday to Friday).
* weekend: Sa Su (Saturday and Sunday)
* daily: Mo Tu We Th Fr Sa Su (Monday to Sunday)
Press OK to accept.
B. Hour and minutes
Timer will show setting for the next parameters: hour and minutes. Set the
values using +/- keys; move to the next parameter with the OK button. Go
back to the previous item by pressing MENU.
Mo T
U
ş
1
ON
OFF
C. ON / OFF
Timer will allow to choose [ON] or [OFF] option.
Set ON or OFF using +/- keys; confirm with OK. Timer will automatically enter
the next ON-OFF COMMAND parameter input mode. Go back to the previous
item by pressing MENU.
PLEASE NOTE!
* The registered ON-OFF commands do not constitute solid pairs of
commands for a contact opening and closing. They are treated as individual
commands and executed in accordance with the specified time chronology.
Cases of overlapping contact closing times from two pairs of ON-OFF
commands are illustrated in the following diagrams:
entry 1
entry 2
contacts 1-5
entry 1
entry 2
contacts 1-5
* Time of contact closing established by a pair of ON-OFF commands can be
longer than 24 hours, which means that [ON] command can be set to any
time and any day of the week (e.g. Tuesday, 1:45 PM) and [OFF] command to
any hour of any other day of the week (e.g. Thursday, 5.05 PM).
4.2 EDITION OF ON / OFF COMMANDS PARAMETERS
Using the +/- keys select the parameter edit mode «edit»
1
Press OK to accept. The timer will enter the memory cell number selecting
mode. Select the cell to edit and accept by pressing OK.
Mo
T
W
T
F
S
S
U
E
H
R
A
U
Proceed as with ON-OFF COMMAND parameters setting (see section 5.1).
ş
1
ON
OFF
-3-
Mo T
W
T
F
S
S
Mo T
W
T
F
S
S
W
E
T
H
F
R
S
A
S
U
U
E
H
R
A
U
U
E
H
R
A
U
ş
ş
1
ON
1
ON
OFF
OFF
Mo T
W
T
F
S
S
U
E
H
R
A
U
ş
1
ON
OFF
entry 1
entry 2
contacts 1-5
ON 1
OFF 1
ON 2
OFF 2
entry 1
entry 2
contacts 1-5
ON 1
OFF 1
ON 1
OFF 1
ON 2
ON 2
entry 1
entry 2
contacts 1-5
ON 1
OFF 1
ON 1
OFF 1
OFF 2
OFF 2
Mo T
W
T
F
S
S
U
E
H
R
A
U
ş
1
ON
1
OFF
Continued on page 5
-4-
К сравнению
Изготовитель: | F&F (Беларусь) |
Артикул: | EA02.002.002 |
Максимальный ток, А: | 2х16 |
Потребляемая мощность, Вт: | 1.5 |
Напряжение питания, В: | 24-264 AC/DC |
Тип контактов: | 2 переключающих |
Количество программ: | 2х125 |
Запас хода, не менее: | 2 года |
Диапазон рабочих температур, ⁰С: | от -25 до +50 |
Габаритные размеры, мм: | 35х90х65 |
Подробнее
- Описание
- Характеристики
- Оплата
- Доставка
- Гарантии
- Документы
- Отзывы
НАЗНАЧЕНИЕ:
Для включения-выключения различных электрических приборов и электроустановок по предварительно установленной программе.
ОТЛИЧИТЕЛЬНЫЕ ОСОБЕННОСТИ:
— напряжение питания 24 — 264 В AC/DC;
— двухканальное;
— суточный и недельный циклы;
— контакт 2NO/NC;
— максимальный ток 16 А;
— функция NFC;
— индикация текущего времени, дня недели и режима работы;
— встроенная Li-ионная батарея, поддерживающая работу программы в течение не менее 2-х лет после отключения напряжения питания;
Изготовитель: | F&F (Беларусь) |
Артикул: | EA02.002.002 |
Максимальный ток, А: | 2х16 |
Потребляемая мощность, Вт: | 1.5 |
Напряжение питания, В: | 24-264 AC/DC |
Тип контактов: | 2 переключающих |
Количество программ: | 2х125 |
Запас хода, не менее: | 2 года |
Диапазон рабочих температур, ⁰С: | от -25 до +50 |
Габаритные размеры, мм: | 35х90х65 |
Способ монтажа: | на DIN-рейку |
Тип подключения: | винтовые зажимы 2,5 мм² |
Гарантия производителя, лет: | 3 |
- наличными или банковской картой при получении товара в пунктах выдачи СДЭК, при условии наличия в них терминала.
- через банк перечислением на наш расчетный счет по выставленному счету.
- по безналичному расчету для юридических лиц.
подробнее
Пункты выдачи в Москве и МО Пункты выдачи в других городах России
Курьерская доставка:
Доставка до адреса осуществляется курьерской службой ежедневно, кроме выходных и праздничных дней.
Стоимость доставки для физических лиц:
До адреса в пределах МКАД – 350р
До адреса за МКАД и по Московской области 500р
В пункты выдачи в пределах МКАД – 150р
В пункты выдачи, расположенные за МКАД и по Московской области -200р
В остальные регионы – по согласованию с менеджером, в зависимости от тарифов курьерской службы.
Стоимость доставки для юридических лиц:
До адреса в пределах МКАД – 600р
До адреса за МКАД и по Московской области 700р
В пункты выдачи в пределах МКАД – 200р
В пункты выдачи, расположенные за МКАД и по Московской области -300р
В остальные регионы – по согласованию с менеджером, в зависимости от тарифов курьерской службы.
ГАРАНТИЯ ПРОИЗВОДИТЕЛЯ:
-
В соответствие с законом «О защите прав потребителя» предоставляется производителем товара, а по всем вопросам гарантийного обслуживания покупатель обращается в сервисный центр производителя.
-
По согласованию возможна отправка товара в сервисный центр через нашу компанию. Все транспортные расходы в этом случае несет покупатель, а сроки исполнения гарантийных обязательств увеличиваются в 1,5-2 раза.
-
Возврат товара надлежащего качества при дистанционной торговле возможен в течение 7 дней после передачи товара. Потребитель обязан в таком случае оплатить стоимость доставки товара до продавца. (п.4 ст.26.1).
-
Обмен товара надлежащего качества в случае, если он не подошел по какой-либо из причин, на аналогичный товар возможен в течение 14 дней после передачи товара. (п.1 ст.25)
-
Возврат и обмен товара возможен, если товар не был в употреблении, сохранены его товарный вид, потребительские свойства, пломбы, а также имеется кассовый чек на приобретение товара. (п.1 ст.25)
-
Потребитель не вправе отказаться от товара, имеющего индивидуально-определенные свойства(товары изготавливаемые и поставляемые под заказ)(п.4 ст.26.1).
Specifications:1436/1436349-pcz5223.pdf file (11 Apr 2023) |
Accompanying Data:
F&F PCZ-522.3 Timer PDF Manual (Updated: Tuesday 11th of April 2023 10:56:28 AM)
Rating: 4.5 (rated by 7 users)
Compatible devices: Limitimer PRO-2000, LST200, T28440, AS-223, UTTND002, DZK 20-A DE 3655, TS631, AS-212.
Recommended Documentation:
Text of Manual
(Ocr-Read Version Summary of Contents, UPD: 11 April 2023)
-
1, F&F Filipowski sp. j. Konstantynowska 79/81 tel/fax +48 42 2152383; 2270971 e-mail: [email protected] 95-200 Pabianice POLAND http:/www.fif.com.pl PROGRAMMABLE CONTROL TIMER dual-channel PCZ-522.3 PURPOSE OPERATION Programmable control timer is used to time control the devices in home or industrial automation systems according to an individual time program set by …
-
2, F&F PCZ-522.3 Continued from page 4 -8- -6—5- -7- 4.3 DELETION – removing entries Confirm by pressing OK. The cell will be deleted. The timer will display the next programmed cell number. Pressing MENU will take you to the root level. PLEASE NOTE! To erase all previous ON-OFF COMMANDS settings see section 5.6. Accept by pressing OK. The timer will enter work mode menu (auto – hand). W…
-
3, Programming scheme MENU 8a8E DATE OPERATION MODE + OK 00 00 i4 YEAR : 00 i400 MONTH : OK 00 07 i4 DAY : OK +1 -1 +1 -1 +1 -1 OK MENU AUTOMATIC MANUAL a088 hah8 + + OK OK SYSTEM SETTINGS In MANUAL operation mode the contact is switched on the main level. i3 : 48 08 PROG Mo TU WE TH FR ş 1 ON i3 : 48 08 PROG Mo TU WE TH FR ş 1 ON OFF PROGRAM pf66 OK 00 00 MINUTES : 00 i5 HOUR : OK …
-
4, Adding and editing programs žAdd or edit program displays a window with following options: ž Operation – selects whether the program will turn the relay on or off . ž Day – selects the days of program execution. You can select a single day, Monday — Friday, Saturday — Sunday, all week. ž Time – selects the time of program execution. Main window 1) …
F&F PCZ-522.3 Recommended Instructions:
A040, BOXWOOD, M2, 324R X-Series
-
ACU-RITE
00534
Digital Timer#00534Instruction ManualINST — 00534 0909091 • OVERVIEW OF FEATURESThank You for purchasing this ACURITE® product. Please read this manual in it’s entirety to fully enjoy the benefits and features of this product. Please keep this manual for future reference.NOTE: A clear film is applied to the display at the factory that must be removed prior to using thi …
00534 2
-
Stanley
TIMERMAX WEEKLY TWIN
TIMERMAX™ WEEKLY TWINCustomer Service / Servicio al Cliente / Service à la Clientèle 1-800-730-3707 • 10AM — 6PM, ESTMonday to Friday / Lunes a Viernes / Lundi au VendrediModel/Modelo/Modele# TM-266QUICK START GUIDEGUÍA DE INICIO RÁPIDOGUIDE DE DÉMARRAGE RAPIDE …
TIMERMAX WEEKLY TWIN 12
-
Melnor
AquaTimer 1 76015
SET CLOCKWATER DAY START WATERHOW LONG AUTOOFFRAIN DELAY, HOLDOKON/OFFMANUALCYCLEA B C DCYCLEHRSDAYMINRESETMANUALAMPMTODAYTIMEWATER EVERYSUFRSATHWETUMOABC DDAYNEXT STARTDELAYCODE:Manual Watering ButtonCycle ButtonBattery IndicatorToggle Button+/- Buttons OK ButtonSET CLOCKWATER DAY START WATERHOW LONG AUTOOFFRAIN DELAY, HOLDOKON/OFFMANUALCYCLEA B C DCYCLEHRSDAYMINRES …
AquaTimer 1 76015 2
-
PowerTran
X 8018
POWERTRAN X 8018 DIGITAL MAINS TIMER INSTRUCTIONSPlease read instructions carefully before connecting timer to mains power source or appliance. IMPORTANT NOTE: Do not plug in an appliance where the load exceeds 10A. Do not spill liquid on the timer or immerse in water. Heaters and similar appliances should never be left running whilst unattended. We recommend not u …
X 8018 2
-
Gira
0385
GIRA Info Electronic Timer Installation Instructions Electronic Timer 12/96 Page 1 of 8 Electronic Timer Order No.: 0385 .. Einstellen EnterMan/AutoAutoManuell Zufall AstroTag ProgDiMiDoFrSaSoMoWocheEINAUSONOFF 1. Description of Functions The Electronic Timer supported by a Microprocessor is placed into a 58 mm recessed box and free of maintenance. A reted load of max …
0385 8
-
Intermatic
DT121C
::BATTERYHOLDERDOORPULLTABFIG. 1FIG. 2FIG. 3 FIG. 4DT121C DIGITAL TIMER INSTRUCTIONSManual Override:To override the ON or OFF settings, press ON/OFF button. The override setting willchange at the next timed event.Battery Replacement (See Fig 5 and 6):When the batteries are running out, LO will be displayed.1) Remove the timer from the wall socket.2) Using a small flat screwdriver, pry the …
DT121C 2