LMV52…

Burner management system for forced draft

burners

LMV52.4…:

— COx supervision and control

User Manual

Based on the following

software versions:

LMV50… :

V10.20

LMV51… :

V05.10

LMV51.3… :

V05.10

LMV52.2.. :

V05.10

LMV52.4… :

V10.20

Int. LR module:

V02.10

Int. VSD module:

V01.50

AZL52…:

V05.00

PLL52…:

V01.50

CC1A7550.5en

07.07.2015

The LMV5 and this User Manual are intended for OEMs which integrate the LMV5

in their products!

Note!

This documentation is only valid together with the LMV5… Basic

Documentation P7550.

Building Technologies Division

Summary of Contents for Siemens LMV52 series

12/17

Building Technologies Division

If a COx signal occurs, a notification is output on the AZL52.

The notification is automatically deleted if no further COx signals are present.

4.9 Displaying the O2 trim controller status

Also refer to the chapter Displaying the O2 trim controller status in the LMV5 Basic

Documentation (P7550).

The status of the O2 trim controller can be read out with the AZL52 via data point State

O2 Ctrl.

The O2 trim controller is not active. The system operates along the

deactivated

ratio control curves.

The manipulated variable of the O2 trim controller is held at the last

locked

value.

Locking time following startup until the O2 trim controller is initialized

LockTStart

or released. The locking time is necessary in order to ensure that the

actual O2 value is measured. The O2 trim controller is still

deactivated or locked

The O2 trim controller is initialized. The O2 trim controller is locked.

InitContr

The O2 trim controller is locked due to a load change.

LockTLoad

The O2 trim controller is active and operates to the O2 setpoint.

active

If switching functions (control interventions by the O2 trim controller)

LockTCAct

are active, the O2 trim controller is locked for 2 x Tau.

If the manipulated variable is affected due to the COx signal, the O2

LockCOx

and COx controllers are locked.

Process data

State O2 Ctrl (deactivated, locked, LockTStart, InitContr,

display values

LockTLoad, active, LockTCAct, LockCOx)

User Manual LMV5…

COx supervision and control

CC1A7550.5en

07.07.2015

Блок управления и индикации показывает на дисплее различные состояния работы горелки и обеспечивает их программирование.

Дисплейный модуль AZL52 предназначен для работы с системами управления LMV5…

Обслуживание и программирование системы управления горелками осуществляется через блок AZL5 или с помощью компьютерной программы. Пульт оператора характеризует понятный текстовый дисплей и работа с помощью меню, что обеспечивает непосредственную работу и целевую диагностику. Для упрощения диагностики на дисплее представлены рабочие состояния, тип отказа, а также точка времени, когда произошел отказ. Различные уровни доступа для изготовителя и обслуживающего инженерного персонала защищены паролем. Основные уставки, необходимые оператору оборудования, не требуют защиты паролем. Более того, AZL5 служат в качестве интерфейса к более высокому уровню системы, такому как диспетчеризация здания и система управления (BACS) или PC с установленным программным обеспечением ACS450.

Блок индикации и управления AZL5…

  • Функции настройки и индикации параметров
  • Сохранение истории неисправностей и ошибок
  • Часы реального времени с запасом хода (например, для регистрации момента обнаружения неисправностей)
  • Контрастность дисплея, регулируемая
  • Язык интерфейса (наличие нескольких языковых групп, с максимум 6 языками в каждой)
  • Отключение нажатием сочетания кнопок 
  • Деблокировка
  • Функция резервного копирования и восстановления параметров
  • Обновление программного обеспечения AZL5… 
  • 4 уровня доступа, 3 из них – с защитой паролем 
  • Индикация технического КПД пламени (если подключены датчики приточного воздуха и отработанного газа)

Интерфейс связи AZL5…

  • Интерфейс RS-232 для обслуживания с помощью ПК при использовании программы ACS450
  • Интерфейс для Modbus, eBus или вывода данных для подключения к системе автоматизации здания или для вывода данных

Применимость в горелочных устройствах:

Артикул CIB UNIGAS: 2022121

Горелки: R1025, R1030, R1040, URB15-G, URB20-G, URB25-G, URB30-G, URB35-G, URB40-G, URB45-G, URB50-G.


Производитель: SIEMENS AG

Сименс

Производитель Германия
Сборка Германия (DE)
Место установки Горелочные устройства
Количество фаз: 1
Класс защиты IP54
Напряжение, В 24

SIEMENS AG

Siemens AG — немецкий концерн, работающий в области электротехники, электроники, энергетического оборудования, транспорта, медицинского оборудования и светотехники, а также специализированных услуг в различных областях промышленности, транспорта и связи. Штаб-квартиры находятся в Берлине и Мюнхене.

Направления деятельности конгломерата Сименс АГ

  • Промышленная автоматизация
  • Автоматизация и безопасность зданий
  • Технологии приводов
  • Энергетика
  • Финансы и лизинг
  • Здравоохранение
  • Мобильность
  • Потребительские товары

Концерн Siemens AG представлен более чем в 190 странах мира, что делает его, наряду с FIFA (208 национальных ассоциаций) и The Coca-Cola Company (свыше 200) одним из лидеров среди компаний и организаций по географии присутствия. По результатам 2009/2010 финансового года (с 1 октября 2008 по 30 сентября 2009 года) оборот компании составил 75,978 млрд евро. Число сотрудников на 30 сентября 2010 года составило 405 000 человек.

Структура компании

Структурно в Siemens AG выделены следующие направления деятельности (на 1 октября 2011 года):

  • Сектор Energy
    • Департамент Fossil Power Generation
    • Департамент Wind Power
    • Департамент Solar & Hydro
    • Департамент Oil & Gas
    • Департамент Energy Service
    • Департамент Power Transmission
  • Сектор Healthcare
    • Департамент Imaging & Therapy Systems
    • Департамент Clinical Products
    • Департамент Diagnostics
    • Департамент Customer Solutions
    • Siemens Audiologische Technik GmbH
  • Сектор Industry
    • Департамент Industry Automation
    • Департамент Drive Technologies
    • Департамент Customer Services
    • Бизнес-единица Metals Technologies
  • Сектор Infrastructure & Cities
    • Департамент Rail Systems
    • Департамент Mobility and Logistics
    • Департамент Low and Medium Voltage
    • Департамент Smart Grid
    • Департамент Building Technologies
    • Департамент OSRAM
  • Кросс-секторные подразделения
    • Siemens Financial Services
  • Siemens Real Estate
  • Стратегические вложения Strategic Equity Investments
    • BSH Bosch und Siemens Hausgeräte GmbH
    • Nokia Siemens Networks BV
    • Siemens Enterprise Communications
  • корпоративные подразделения, региональные офисы, дочерние фирмы.

SIEMENS AZL52.09B1 Жидкокристаллический дисплейный блок

Блок управления и индикации показывает на дисплее различные состояния работы горелки и обеспечивает их программирование.

Дисплейный модуль AZL52 предназначен для работы с системами управления LMV5…

Обслуживание и программирование системы управления горелками осуществляется через блок AZL5 или с помощью компьютерной программы. Пульт оператора характеризует понятный текстовый дисплей и работа с помощью меню, что обеспечивает непосредственную работу и целевую диагностику. Для упрощения диагностики на дисплее представлены рабочие состояния, тип отказа, а также точка времени, когда произошел отказ. Различные уровни доступа для изготовителя и обслуживающего инженерного персонала защищены паролем. Основные уставки, необходимые оператору оборудования, не требуют защиты паролем. Более того, AZL5 служат в качестве интерфейса к более высокому уровню системы, такому как диспетчеризация здания и система управления (BACS) или PC с установленным программным обеспечением ACS450.

Блок индикации и управления AZL5…

  • Функции настройки и индикации параметров
  • Сохранение истории неисправностей и ошибок
  • Часы реального времени с запасом хода (например, для регистрации момента обнаружения неисправностей)
  • Контрастность дисплея, регулируемая
  • Язык интерфейса (наличие нескольких языковых групп, с максимум 6 языками в каждой)
  • Отключение нажатием сочетания кнопок 
  • Деблокировка
  • Функция резервного копирования и восстановления параметров
  • Обновление программного обеспечения AZL5… 
  • 4 уровня доступа, 3 из них – с защитой паролем 
  • Индикация технического КПД пламени (если подключены датчики приточного воздуха и отработанного газа)

Интерфейс связи AZL5…

  • Интерфейс RS-232 для обслуживания с помощью ПК при использовании программы ACS450
  • Интерфейс для Modbus, eBus или вывода данных для подключения к системе автоматизации здания или для вывода данных

Применимость в горелочных устройствах:

Артикул CIB UNIGAS: 2022121

Горелки: R1025, R1030, R1040, URB15-G, URB20-G, URB25-G, URB30-G, URB35-G, URB40-G, URB45-G, URB50-G.

Артикул OILON: 36106031 (WD100 and WD200 Russia)


Производитель: SIEMENS AG

Сименс

Производитель Германия
Сборка Германия (DE)
Место установки Горелочные устройства
Количество фаз: 1
Класс защиты IP54
Напряжение, В 24

SIEMENS AG

Siemens AG — немецкий концерн, работающий в области электротехники, электроники, энергетического оборудования, транспорта, медицинского оборудования и светотехники, а также специализированных услуг в различных областях промышленности, транспорта и связи. Штаб-квартиры находятся в Берлине и Мюнхене.

Направления деятельности конгломерата Сименс АГ

  • Промышленная автоматизация
  • Автоматизация и безопасность зданий
  • Технологии приводов
  • Энергетика
  • Финансы и лизинг
  • Здравоохранение
  • Мобильность
  • Потребительские товары

Концерн Siemens AG представлен более чем в 190 странах мира, что делает его, наряду с FIFA (208 национальных ассоциаций) и The Coca-Cola Company (свыше 200) одним из лидеров среди компаний и организаций по географии присутствия. По результатам 2009/2010 финансового года (с 1 октября 2008 по 30 сентября 2009 года) оборот компании составил 75,978 млрд евро. Число сотрудников на 30 сентября 2010 года составило 405 000 человек.

Структура компании

Структурно в Siemens AG выделены следующие направления деятельности (на 1 октября 2011 года):

  • Сектор Energy
    • Департамент Fossil Power Generation
    • Департамент Wind Power
    • Департамент Solar & Hydro
    • Департамент Oil & Gas
    • Департамент Energy Service
    • Департамент Power Transmission
  • Сектор Healthcare
    • Департамент Imaging & Therapy Systems
    • Департамент Clinical Products
    • Департамент Diagnostics
    • Департамент Customer Solutions
    • Siemens Audiologische Technik GmbH
  • Сектор Industry
    • Департамент Industry Automation
    • Департамент Drive Technologies
    • Департамент Customer Services
    • Бизнес-единица Metals Technologies
  • Сектор Infrastructure & Cities
    • Департамент Rail Systems
    • Департамент Mobility and Logistics
    • Департамент Low and Medium Voltage
    • Департамент Smart Grid
    • Департамент Building Technologies
    • Департамент OSRAM
  • Кросс-секторные подразделения
    • Siemens Financial Services
  • Siemens Real Estate
  • Стратегические вложения Strategic Equity Investments
    • BSH Bosch und Siemens Hausgeräte GmbH
    • Nokia Siemens Networks BV
    • Siemens Enterprise Communications
  • корпоративные подразделения, региональные офисы, дочерние фирмы.

12/17

Building Technologies Division

If a COx signal occurs, a notification is output on the AZL52.

The notification is automatically deleted if no further COx signals are present.

4.9 Displaying the O2 trim controller status

Also refer to the chapter Displaying the O2 trim controller status in the LMV5 Basic

Documentation (P7550).

The status of the O2 trim controller can be read out with the AZL52 via data point State

O2 Ctrl.

The O2 trim controller is not active. The system operates along the

deactivated

ratio control curves.

The manipulated variable of the O2 trim controller is held at the last

locked

value.

Locking time following startup until the O2 trim controller is initialized

LockTStart

or released. The locking time is necessary in order to ensure that the

actual O2 value is measured. The O2 trim controller is still

deactivated or locked

The O2 trim controller is initialized. The O2 trim controller is locked.

InitContr

The O2 trim controller is locked due to a load change.

LockTLoad

The O2 trim controller is active and operates to the O2 setpoint.

active

If switching functions (control interventions by the O2 trim controller)

LockTCAct

are active, the O2 trim controller is locked for 2 x Tau.

If the manipulated variable is affected due to the COx signal, the O2

LockCOx

and COx controllers are locked.

Process data

State O2 Ctrl (deactivated, locked, LockTStart, InitContr,

display values

LockTLoad, active, LockTCAct, LockCOx)

User Manual LMV5…

COx supervision and control

CC1A7550.5en

07.07.2015

В процессе эксплуатации бытовые приборы могут часто приходить в неисправность. Стиральные машины Siemens не являются исключением. Программное обеспечение данных устройство позволяет сообщать владельцу, в чем заключается проблема поломки.

Если стиральная машина отказывается нормально работать и выводит на экран определенный код ошибки, нужно выяснить, что он означает. Если руководство к машинке Siemens утеряно, то вам потребуется детальная расшифровка всех проблем, которая наведена ниже.

Коды ошибок в стиральных машинах Сименс

Программное обеспечение стиральных машин позволяет довольно точно информировать владельца о причине неисправности. Поломки могут носить самый разнообразный характер, начиная от износа деталей и заканчивая сбоями в электронике. Это дает возможность владельцу или мастеру быстро и точно провести восстановительные работы устройства.

В стиральных машинах Siemens выделяют два основных типа кодов:

  • Exx – информируют о сбоях в работе электродвигателя или контроллера управления.
  • Fxx – связаны с проблемами подогрева, подачи и слива воды.

 

Список ошибок стиральных машин Сименс

Ошибка E02 – сигнализирует владельцу о проблеме с электрическим мотором стиральной машины. Проблема может заключаться в нарушении контактов или отсутствии сопротивления.

Ошибка E17 – появляется на экране, если вода не поступает в машину. Соответственно, процесс стирки не может быть начат. Как правило, проблема заключается в перекрытом кране, засоре очистной сетки или низком давлении воды в системе. В некоторых случаях причиной неисправности служит поломка заливного клапана или обрыв проводов.

Ошибка E18 – говорит о проблеме со сливом. Если в течение 10 минут не произошел запрограммированный слив, устройство диагностирует именно эту ошибку. Причин может быть много: засор в системе, поломка помпы или нарушение проводки. Также не нужно исключать проблем с электронным контроллером.

Ошибка E21 – барабан не вращается, машинка не начинает выполнение заданной программы. Проблема может заключаться в повреждении электропроводки двигателя или коротком замывании реле реверса. В некоторых ситуациях ошибка может говорить о слете ремня привода со шкива. Еще как вариант износ щеток электродвигателя.

Ошибка E22 – данная ошибка свидетельствует о том, что устройство включило автоматическую систему защиты от протечки воды. Первое, что нужно выявить – течь и постараться устранить ее. Если вытекание отсутствует, то поломка заключается в неисправности самого датчика защиты.

Ошибка E26 – аварии в работе датчика воды (переостате). Машина не будет сливать или набирать воду. В большинстве случаев, это связано с обрывом в электрической цепи или поломке самого датчика.

Ошибка E29 – такая информация на экране говорит владельцу стиральной машине о слабом напоре воды в системе. Иногда это может быть вызвано перегибом шланга подключения. Не лишним будет проверить и сетчатый фильтр в месте подвода.

Ошибка E32 – проблемы с датчиком температуры. Машина не способна осуществить контролированный нагрев до нужно отметки. Скорее всего, проблема в самом датчике или эго электрической цепи питания.

Ошибка E36 – при данной ошибке на экране дверь машинки не может полноценно закрыться. Причиной неисправности может быть поломка модуля управления, обратной части замка двери или повреждение проводов.

Ошибка E43 – это сигнализация о поломке замка двери стиральной машины. Поломка связана с управлением симистора.

Ошибка E61 – некорректная работа замка двери. Причиной может служить как неисправность ответной части защелки, так и более серьезные повреждения платы или программный сбой.

Ошибка F04 – неработоспособность связанна с разгерметизацией системы. Под стиральной машиной может образоваться лужа воды. В некоторых случаях она может скопиться в поддоне. В любом из вариантов нужно локализовать и устранить течь.

Ошибка F12 – данная ошибка свидетельствует о сбое в работе двигателя. Сама машина может гудеть, но барабан вращаться не будет. Проблема заключается в поломке двигателя или его элементов.

Ошибка F16 – после выбора программы и нажатия кнопки старт, процесс стирки не начинается. Из-за этого может высветиться данная ошибка. Она может говорить владельцу о том, что дверь не закрыта. Иногда это может быть вызвано временным программным сбоем.

Ошибка F17 – при появлении данной ошибки машина очень медленно, или вовсе не набирает воду. Причина кроется в низком давлении воды или засоре системы. Нужно внимательно пересмотреть шланги подключения на предмет перегиба или засора. Отметим, что оптимальное давление для нормальной работы должно составлять не менее 1 Бара.

Ошибка F18 – с появлением ошибки машина будет неспешно сливать воду. Вместе с тем машина в автоматическом режиме может перевести любую программу в режим «важная неисправность». Проблемы связаны с поломкой сливного насоса или сбоем контроллера уровня воды.

Ошибка F21 – полная остановка барабана или неравномерное вращение. Возможные неисправности: поломка реле реверса, поломка тахогенератора или короткое замыкание симистора.

Ошибка F23 – код говорит об активизации системы защиты «Аквастоп». Программное обеспечение сигнализирует о наличии течи в системе.

Ошибка F43 – это критическая ошибка, при которой барабан не будет вращаться, а сама машина не будет откликаться на команды. Проблема может свидетельствовать о заклинивании барабана, поломке тахогенератора или сбои блока управления.

Ошибка А02 – машина говорит об отсутствии воды. Это может быть вызванным слабым напором, засорением шланга или сетки очистки.

Что делать и как устранить ошибки в СМА Siemens?

Рассмотрим наиболее распространенные признаки поломок и как их можно устранить:

  • Мигает ключ блокировки двери – проблема заключается в поломке замка двери, проблеме с двигателем или модулем управления. Так же это может свидетельствовать о сбое в прошивке. Нужна комплексная диагностика системы.
  • Ошибка горят галочки – ситуация говорит о системном сбое программного обеспечения. Если перезагрузка не принесла положительного результата, потребуется диагностика.
  • Не нагревает воду – нужна замена нагревательного элемента.
  • Не сливает воду с барабана – потребуется обследование работоспособности сливного насоса. Важно провести качественную очистку. При необходимости проводят помпы.
  • Машина не может полноценно набрать обороты при отжиме – потребуется ремонт мотора – замена щеток.
  • Блок управления выдает множество ошибок и не может полноценно выполнить поставленную задачу – нужна комплексная диагностика системы. Возможно, необходима новая прошивка или замена блока.
  • Протекание – чаще всего это связано с трещинами резинового манжета люка. Решить проблему можно заменой элемента.
  • Сильные стуки и грохот в работе – износ подшипников барабана – потребуется их замена вместе с сальниками.

 

Все эти ошибки и неисправности могут проявляться в таких моделях стиральных машин:

  1. Siemens iq700
  2. Siemens iq500
  3. Siemens iq300
  4. Siemens ws10k2400e

 

Это далеко не полный список, поскольку все машины данного бренда имеют общее программное обеспечение с идентичными сигналами.

Студворк — интернет-сервис помощи студентам

Уважаемые форумчане, вижу, что форум тяготеет, скорее, к программной составляющей АСУ, но может быть кто-то уже сталкивался с подобным.

Газовая горелка управляется автоматом горения Siemens LMV 52.200B2. Не часто, примерно, через каждые месяц-полтора, возникает ошибка, сохраненная в списке аварий, как
C=A1 D=05 P=? (не записал фазу) «Мало времени для рампы привода воздуха»
После сброса аварии горелка запускалась.

В инструкции cc1p7550ru (перевод cc1p7550en от 13.08.2004) для этого кода просто дублируется текстовое сообщение с AZL.
Жалюзи (нагрузка привода) при выключенном вентиляторе и снятом приводе поворачиваются легко.
С пульта AZL привод управляется (для проверки изменяли уставку положения покоя).

Где-то полгода-год назад заменили сам привод на идентичный из ЗИП — ошибки (повторюсь, редкие) вроде бы прекратились, но и вскоре котёл был выведен из эксплуатации за ненадобностью, в мае снова введён в строй. В июне ошибка опять возникла (точную дату не назову — авария имеет номер 10, а девятая датирована серединой июня).

Обратил внимание, что время полного хода различно для разных приводов
1) Воздух
SQM48.697A9 >60s/90° 35Nm
2) Газ, Ж/Т
SQM48.497A9 >30s/90° 20Nm

Когда «лазил» по менюшкам этого и других LMV без пароля и с паролем HF не находил каких-либо настроек для приводов кроме настройки адресов и «минимальный шаг приводов» (=1,0%).

Что может быть причиной такой периодической аварии?

Понравилась статья? Поделить с друзьями:
  • Siemens a02 ошибка iq500
  • Siemens 808d ошибка 014011
  • Siege ошибка соединения
  • Sideloadly ошибка guru meditation
  • Sideloadly ошибка 36607