Siemens ошибка 700063

Remedy

+

4.1.9

Alarm description

It is not a fault but a reminder that the time is up for the first service plan preset on the control system. You need to execute

the service plan immediately.

PLC information

PLC address: DB1600.DBX3.6

Subroutine: PI_SERVICE (SBR 46)

Remedy

1.

+

2.

3.

4.

4.1.10

Alarm 700060

Alarm description

It is not possible to change the program test state on the control system during program execution. You must first place the

control system to the reset state.

PLC information

PLC address: DB1600.DBX7.4

Subroutine: MCP_NCK (SBR 37)

Service Manual

01/2017

1.

Check the preset service maintenance plan and make the relevant preparations.

2.

Select the system data operating area.

3.

Press this key on the PPU to access the extended softkeys.

4.

Enter the main screen of service planning.

5.

Press this softkey on the PPU to cancel the alarm.

Select the system data operating area.

Press this key on the PPU to access the extended softkeys.

Enter the main screen of service planning.

Press this softkey on the PPU after executing the relevant service plan to cancel the alarm.

35

storage05

Новичок
Сообщения: 5
Зарегистрирован: 22 май 2018, 17:39
Репутация: 0
Настоящее имя: Александр
Контактная информация:

Siemens sinumeric 808D ошибка при запуске 700001

Станок токарный на выше названной стойке, после включения выдает ошибку 700001 (HHU is active —:—), информации в интернете 0, в инструкции тоже.
Станок был куплен БУ в рабочем состоянии, первый запуск на новом месте.

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 18:43

storage05, не нужно кучу тем плодить. У тебя есть тема про обучение, там бы и продолжал.
Я так понимаю стойка у тебя не руссифицирована?

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 19:14

storage05 писал(а): Нет стойка английская.

Если хош учиться, нужно смотреть видео, качать мануалы и читать.

1. Идем сюды https://cache.industry.siemens.com/dl/f … _ru-RU.pdf
2. Листаем до стр 15
3. Если этого нет то пишем письмо сюды https://www.siemens.com/ru/ru/home.html с просьбой обновить стойку. Перед обновлением, сохранить архив(как это делается есть в мануале).
Тогда тебе стойка будет писать по русский что ей не нравиться ;)

storage05 писал(а):
(HHU is active —:—), информации в интернете 0, в инструкции тоже.

Если в инете в поисковике набрать HHU Siemens то находим мануал на какой то станок https://flintmachine.com/images/uploads … Manual.pdf где на 15стр есть картинка что такое HHU И ошибка тебе пишет что активен HHU, а ты тыкаешь в клаву на стойке ;)

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 19:15

storage05 писал(а):Ту тему закинули в ветку с объявлениями предложения услуг, я не понял зачем.

Ты же ищешь кто тебе за деньги научит станком пользоваться. Вот в услуги и снесли.
Кстати, а почему не заплатить тому оператору который работал на этом станке чтоб он обучил работе ?

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

storage05

Новичок
Сообщения: 5
Зарегистрирован: 22 май 2018, 17:39
Репутация: 0
Настоящее имя: Александр
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

storage05 » 23 май 2018, 19:26

Я пытаюсь научится работать, для себя, что бы понимать все процессы производства. Что бы не приходили ко мне звездные сотрудники и не впаривали мне всякую хрень выгибая пальцы веером. Когда сам знаешь все процессы гораздо проще))

Расскажи пожалуйста подробнее как обновлять? не понял, нужно писать письмо в сименс?

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 19:32

storage05 писал(а):Расскажи пожалуйста подробнее как обновлять?

Что сложного?
1. Открываем мануал по ссылке: https://cache.industry.siemens.com/dl/f … _ru-RU.pdf
2. Идем на стр 15
3. Там видим картинку

02.png (9137 просмотров) <a class='original' href='./download/file.php?id=139637&sid=e06888a5e8783626c033162d3a9106e1&mode=view' target=_blank>Загрузить оригинал (138.78 КБ)</a>

На картинке все четко нарисовано как и что жать. Куда проще?

storage05 писал(а):не понял, нужно писать письмо в сименс?

Если нет в списке русского языка, тогда нужно обновлять стойку, а для этого обращаться в Сименс.

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

storage05

Новичок
Сообщения: 5
Зарегистрирован: 22 май 2018, 17:39
Репутация: 0
Настоящее имя: Александр
Контактная информация:

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 19:39

storage05 писал(а):Это я читал ,у меня только англ и китайский.

Выдать обновление может Сименс, после проверки серийников стойки. После этого появляется русский язык. Стойка у вас видать старая, в новых стойках русский уже вшит.

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

storage05

Новичок
Сообщения: 5
Зарегистрирован: 22 май 2018, 17:39
Репутация: 0
Настоящее имя: Александр
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

storage05 » 23 май 2018, 20:03

Будем побеждать английский)) с HH разобрался.
Еще две ошибки выходит:
700026 Not able to find expected tool in monitor time — при смене инструмента
700013 Operation while chuck is not locked — при включении шпинделя
Только не кидай мне ссылку на переводчик )))))))))))))))))))
Я так понимаю что надо где-то заблокировать шпидиль, а вот с инструментом не совсем.

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 20:07

storage05 писал(а):700026 Not able to find expected tool in monitor time — при смене инструмента

Начинает вращать револьверку и потом ошибка?

storage05 писал(а):Operation while chuck is not locked — при включении шпинделя

Надо видеть фото станка что на нем стоит.
Наверно говорит что патрон не зажат, а вращать не зажатый патрон не есть хорошо.

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

storage05

Новичок
Сообщения: 5
Зарегистрирован: 22 май 2018, 17:39
Репутация: 0
Настоящее имя: Александр
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

storage05 » 23 май 2018, 20:16

aftaev писал(а):

storage05 писал(а):700026 Not able to find expected tool in monitor time — при смене инструмента

Начинает вращать револьверку и потом ошибка?

storage05 писал(а):Operation while chuck is not locked — при включении шпинделя

Надо видеть фото станка что на нем стоит.
Наверно говорит что патрон не зажат, а вращать не зажатый патрон не есть хорошо.

Она на месте стоит, но звук есть. (хотя когда покупал он вращался) мне демонстрировали

Вложения
IMG_2751-23-05-18-08-11.jpeg (9087 просмотров) <a class='original' href='./download/file.php?id=139642&sid=e06888a5e8783626c033162d3a9106e1&mode=view' target=_blank>Загрузить оригинал (679.9 КБ)</a>

Аватара пользователя

N1X

Мастер
Сообщения: 3647
Зарегистрирован: 16 фев 2015, 21:19
Репутация: 1645
Настоящее имя: Владимир
Откуда: Беларусь, Гомель
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

N1X » 23 май 2018, 20:20

Все ошибки выше 700000 — это ошибки производителя станка, т.е. в мануале на станок, а не на ЧПУ смотреть нужно…
А так да, google translate в помощь :)
Афтаев выше верно расшифровал… Патрон обычно после включения станка считается не зажатым, даже если и зажат. Его разжать/зажать нужно…

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 20:40

storage05 писал(а):Она на месте стоит, но звук есть. (хотя когда покупал он вращался) мне демонстрировали

Когда демонстрируют работу оборудования, нужно брать камеру и снимать этот процесс, чтобы хотябы стандартные шаги показали. Как включить, выгнать в НОМЕ и тд…

Мож при транспортировке где нибудь проводок отвалился и нет одной фазы на двиг револьверки, вот он урчит, но не шевелиться. ЧПУ ждет когда револьверка повернется на нужный инструмент. Проверять все разъемы. Выдернуть разъем, и обратно воткнуть. Куча разъемов находиться сзади стойки 808D
:attention: Выдергивать разъемы только при обесточенном станке.

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

Аватара пользователя

Lexxa

Мастер
Сообщения: 2702
Зарегистрирован: 16 дек 2011, 16:48
Репутация: 319
Настоящее имя: Алексей
Откуда: ryazan
Контактная информация:

Аватара пользователя

Lexxa

Мастер
Сообщения: 2702
Зарегистрирован: 16 дек 2011, 16:48
Репутация: 319
Настоящее имя: Алексей
Откуда: ryazan
Контактная информация:

aftaev

Зачётный участник
Зачётный участник
Сообщения: 34042
Зарегистрирован: 04 апр 2010, 19:22
Репутация: 6186
Откуда: Казахстан.
Контактная информация:

Re: Siemens sinumeric 808D ошибка при запуске 700001

Сообщение

aftaev » 23 май 2018, 21:19

Lexxa писал(а):тогда как то надо продавать станок…

чур я первый в очереди, я знаю где ПЛС смотреть :)

Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.

Только что, David123 сказал:

Уважаемый @nein !

1) Насколько я понял, Вы умеете обращаться с архивами, первым делом сохраните текущий архив NC.

2) Ошибку 700004 — выдает электроавтоматика станка. Она должна быть описана в Руководстве по станку. Что там сказано?

3)  Эта ошибка всегда выводится или ранее станок работал, выдавал готовую продукцию, но произошли какие-то обстоятельства, после чего происходит описываемое.

4) Эта ошибка выводится сразу после первоначальной загрузки системы или какие-то действия производятся на станке? Нет ли в строке вывода ошибки, сразу после номера 700004 символа «стрелка вниз». Это признак — одновременно появились несколько ошибок или сообщений. В области ДИАГНОСТИКА можно найти полный их список. Сделайте их фото.

5) Есть ли у Вас проект (не архив) электроавтоматики станка?

Уважаемый@David123 , большое спасибо, что пытаетесь помочь.

1) Текущий архив NC я сразу сохранил.

2) Там сказано — замените предохранитель или включите автомат.

3) Начну с самого начала. Мы купили станок в Турции. Когда он приехал, он включился, но выдавал другие ошибки. Включался свет в рабочей зоне от кнопки. Выяснилось, что там не было заглушки на разъёме подключения податчика прутка. Я стал ставить заглушку, но в процессе перевозки или погрузки станка этот разъём был сломан. В результате там что-то перемкнулось, и теперь выпадает такая ошибка про предохранитель. Разъём мы заменили, цепи прозвонили — всё нормально. Но теперь ошибка не уходит. Свет не включается.

Теперь вернусь к автоматам. Все цепочки — нормальные. На фотографии 1 на модуле 9А3 горят светодиоды B2.7 и B3.0 — т.е. все автоматы нормальные. На фотографии 2 на блоке питания 9А1 постоянно горит красный светодиод FAULT. На фотографии 1 видно, что горят светодиоды на модулях 9А3 и 9А4 (это если мы правильно понимаем, входные цепи для 9А1) и не горят на выходном модуле 9А5. Сам блок 9А1 мы меняли (брали точно такой же с соседнего рабочего станка) — ничего не менялось. X3/IN — это связь с PLC.

4) Ошибка выпадает сразу при загрузке. Я разговаривал с сервисником Шпиннера из Болгарии, он сказал, что все остальные ошибки — это производные от 700004. Завтра сделаю фото области «диагностика».

5) Нет, проекта у меня нет.

1.jpg

2.jpg

ошибки.jpeg

В процессе эксплуатации бытовые приборы могут часто приходить в неисправность. Стиральные машины Siemens не являются исключением. Программное обеспечение данных устройство позволяет сообщать владельцу, в чем заключается проблема поломки.

Если стиральная машина отказывается нормально работать и выводит на экран определенный код ошибки, нужно выяснить, что он означает. Если руководство к машинке Siemens утеряно, то вам потребуется детальная расшифровка всех проблем, которая наведена ниже.

Коды ошибок в стиральных машинах Сименс

Программное обеспечение стиральных машин позволяет довольно точно информировать владельца о причине неисправности. Поломки могут носить самый разнообразный характер, начиная от износа деталей и заканчивая сбоями в электронике. Это дает возможность владельцу или мастеру быстро и точно провести восстановительные работы устройства.

В стиральных машинах Siemens выделяют два основных типа кодов:

  • Exx – информируют о сбоях в работе электродвигателя или контроллера управления.
  • Fxx – связаны с проблемами подогрева, подачи и слива воды.

 

Список ошибок стиральных машин Сименс

Ошибка E02 – сигнализирует владельцу о проблеме с электрическим мотором стиральной машины. Проблема может заключаться в нарушении контактов или отсутствии сопротивления.

Ошибка E17 – появляется на экране, если вода не поступает в машину. Соответственно, процесс стирки не может быть начат. Как правило, проблема заключается в перекрытом кране, засоре очистной сетки или низком давлении воды в системе. В некоторых случаях причиной неисправности служит поломка заливного клапана или обрыв проводов.

Ошибка E18 – говорит о проблеме со сливом. Если в течение 10 минут не произошел запрограммированный слив, устройство диагностирует именно эту ошибку. Причин может быть много: засор в системе, поломка помпы или нарушение проводки. Также не нужно исключать проблем с электронным контроллером.

Ошибка E21 – барабан не вращается, машинка не начинает выполнение заданной программы. Проблема может заключаться в повреждении электропроводки двигателя или коротком замывании реле реверса. В некоторых ситуациях ошибка может говорить о слете ремня привода со шкива. Еще как вариант износ щеток электродвигателя.

Ошибка E22 – данная ошибка свидетельствует о том, что устройство включило автоматическую систему защиты от протечки воды. Первое, что нужно выявить – течь и постараться устранить ее. Если вытекание отсутствует, то поломка заключается в неисправности самого датчика защиты.

Ошибка E26 – аварии в работе датчика воды (переостате). Машина не будет сливать или набирать воду. В большинстве случаев, это связано с обрывом в электрической цепи или поломке самого датчика.

Ошибка E29 – такая информация на экране говорит владельцу стиральной машине о слабом напоре воды в системе. Иногда это может быть вызвано перегибом шланга подключения. Не лишним будет проверить и сетчатый фильтр в месте подвода.

Ошибка E32 – проблемы с датчиком температуры. Машина не способна осуществить контролированный нагрев до нужно отметки. Скорее всего, проблема в самом датчике или эго электрической цепи питания.

Ошибка E36 – при данной ошибке на экране дверь машинки не может полноценно закрыться. Причиной неисправности может быть поломка модуля управления, обратной части замка двери или повреждение проводов.

Ошибка E43 – это сигнализация о поломке замка двери стиральной машины. Поломка связана с управлением симистора.

Ошибка E61 – некорректная работа замка двери. Причиной может служить как неисправность ответной части защелки, так и более серьезные повреждения платы или программный сбой.

Ошибка F04 – неработоспособность связанна с разгерметизацией системы. Под стиральной машиной может образоваться лужа воды. В некоторых случаях она может скопиться в поддоне. В любом из вариантов нужно локализовать и устранить течь.

Ошибка F12 – данная ошибка свидетельствует о сбое в работе двигателя. Сама машина может гудеть, но барабан вращаться не будет. Проблема заключается в поломке двигателя или его элементов.

Ошибка F16 – после выбора программы и нажатия кнопки старт, процесс стирки не начинается. Из-за этого может высветиться данная ошибка. Она может говорить владельцу о том, что дверь не закрыта. Иногда это может быть вызвано временным программным сбоем.

Ошибка F17 – при появлении данной ошибки машина очень медленно, или вовсе не набирает воду. Причина кроется в низком давлении воды или засоре системы. Нужно внимательно пересмотреть шланги подключения на предмет перегиба или засора. Отметим, что оптимальное давление для нормальной работы должно составлять не менее 1 Бара.

Ошибка F18 – с появлением ошибки машина будет неспешно сливать воду. Вместе с тем машина в автоматическом режиме может перевести любую программу в режим «важная неисправность». Проблемы связаны с поломкой сливного насоса или сбоем контроллера уровня воды.

Ошибка F21 – полная остановка барабана или неравномерное вращение. Возможные неисправности: поломка реле реверса, поломка тахогенератора или короткое замыкание симистора.

Ошибка F23 – код говорит об активизации системы защиты «Аквастоп». Программное обеспечение сигнализирует о наличии течи в системе.

Ошибка F43 – это критическая ошибка, при которой барабан не будет вращаться, а сама машина не будет откликаться на команды. Проблема может свидетельствовать о заклинивании барабана, поломке тахогенератора или сбои блока управления.

Ошибка А02 – машина говорит об отсутствии воды. Это может быть вызванным слабым напором, засорением шланга или сетки очистки.

Что делать и как устранить ошибки в СМА Siemens?

Рассмотрим наиболее распространенные признаки поломок и как их можно устранить:

  • Мигает ключ блокировки двери – проблема заключается в поломке замка двери, проблеме с двигателем или модулем управления. Так же это может свидетельствовать о сбое в прошивке. Нужна комплексная диагностика системы.
  • Ошибка горят галочки – ситуация говорит о системном сбое программного обеспечения. Если перезагрузка не принесла положительного результата, потребуется диагностика.
  • Не нагревает воду – нужна замена нагревательного элемента.
  • Не сливает воду с барабана – потребуется обследование работоспособности сливного насоса. Важно провести качественную очистку. При необходимости проводят помпы.
  • Машина не может полноценно набрать обороты при отжиме – потребуется ремонт мотора – замена щеток.
  • Блок управления выдает множество ошибок и не может полноценно выполнить поставленную задачу – нужна комплексная диагностика системы. Возможно, необходима новая прошивка или замена блока.
  • Протекание – чаще всего это связано с трещинами резинового манжета люка. Решить проблему можно заменой элемента.
  • Сильные стуки и грохот в работе – износ подшипников барабана – потребуется их замена вместе с сальниками.

 

Все эти ошибки и неисправности могут проявляться в таких моделях стиральных машин:

  1. Siemens iq700
  2. Siemens iq500
  3. Siemens iq300
  4. Siemens ws10k2400e

 

Это далеко не полный список, поскольку все машины данного бренда имеют общее программное обеспечение с идентичными сигналами.

Анатолий Д.

Рекомендуемые сообщения

  •  #1

:help: Доброго времени суток..!

Может кто плотно знаком с системой ЧПУ SIЕMENS на станке РТ772Ф311.

При запуске станка выдаёт ошибку 700009 — Аварийное сообщение пользователя 10 — это пишется на экране, а по описанию ошибок от завода — перегрузка охлаждения. :unknw: . Оборудование холодное не работало же вообще :rolleyes: ?

И 700002 — револьверный станок не зажат — а производитель пишет про это = нет готовности блока питания.. Внешне осмотрел нит какого «криминала» не обнаруживается…………….

Поделиться сообщением


Ссылка на сообщение

  •  #2

надо смотреть питание после транса 24в и 110в , ещё доп контакты на автоматах!

Поделиться сообщением


Ссылка на сообщение

  •  #3

mechanic25, 24 в идёт на питание релюшек и освещения местного, изменения в яркости фонаря нет! Если перегруз охлаждения где-то же наверно теплушка стоит!?

Поделиться сообщением


Ссылка на сообщение
  •  #4

Надо электросхему изучать — смотрите входные сигналы и разбирайтесь откуда они приходят.

Возможно это где-то защита сработала.

нет готовности блока питания

Возможно, это имеется в виду блок питания приводов. Какие привода?


Изменено 06.11.2013 15:19 пользователем tmpr

Поделиться сообщением


Ссылка на сообщение

  •  #5

Ошибка появляется при включении циркуляционной системы смазки……… по току ни где ни чего не предусмотрено перегруз контролировать.

Поделиться сообщением


Ссылка на сообщение

  •  #6

Тогда у меня есть подозрение, что всё это относится к блоку питания приводов.

Он тоже сименс?

по току ни где ни чего не предусмотрено перегруз контролировать.

Автоматы-то есть? С ними всё нормально?


Изменено 06.11.2013 15:29 пользователем tmpr

Поделиться сообщением


Ссылка на сообщение

  •  #7

На контроллере нет индикации входов и выходов :unknw: — хотя в РЭ я нашёл описание входов и вых контроллера электоавтоматики. Завтра надо прозванивать релюшки. Знать хотя бы как организованна система опроса оборудования ……..

Поделиться сообщением


Ссылка на сообщение

  •  #8

Какая модель ЧПУ?

В разделе «диагностика-состояние PLC» можно увидеть состояние входов/выходов.

хотя в РЭ я нашёл описание входов и вых контроллера электоавтоматики

вот это полезно, надо сначала посмотреть всё ли в порядке перед включением.


Изменено 06.11.2013 15:36 пользователем tmpr

Поделиться сообщением


Ссылка на сообщение

  •  #9

Модуль управления тоже Siemens. Там тоже ни индикации ошибки, ни каких либо признаков неисправности. Фильтра подозрительно шумят, хотя на втором станке аналогичный шум чуть потише.

Поделиться сообщением


Ссылка на сообщение

  •  #10

Ф311 наверно! или это наша маркировка!?

Поделиться сообщением


Ссылка на сообщение

  •  #11

Модуль управления тоже Siemens.

вы на бирке посмотрите номер (типа 6SNхххх-хххх-хххх), будет понятнее, что у вас за техника

На блоке питания есть шесть цветных диодов — что они показывают?

Ф311 наверно! или это наша маркировка!?

нет, это маркировка станка по советской системе. На самом сименсе надо смотреть бирки или в интерфейсе, где-то есть экран.


Изменено 06.11.2013 15:42 пользователем tmpr

Поделиться сообщением


Ссылка на сообщение

  •  #12

В подминю видел диагностика PLC» но не полез туда, у меня в принципе нет особого образования. Если что где прописано могу пошагово разобраться :rolleyes: . Так станки у нас пропохали с 08.2005 практически в две смены без особых проблем. Ну вылазили мелочи по некорректной работе микриков, да проподанию контакта в соединениях разъёмов. А сегодня всё пролез и ни хр=на тишина :80:

Поделиться сообщением


Ссылка на сообщение

  •  #13

tmpr,post-15251-027460800 1383796590_thumb.jpg

Вот фото

Ни каких различий между индикацией с работающим станком………………….

Все остальные ошибки понятны но Почему перегруз охлаждения,,,,?:(


Изменено 07.11.2013 04:18 пользователем Анатолий Д.

Поделиться сообщением


Ссылка на сообщение
  •  #14

о Почему перегруз охлаждения,,,,?:(

эту ошибку программировал производитель станка, что он имел ввиду — это у него надо спрашивать. В вашем случае, нужно разбираться со всеми входами/выходами — какого-то явно не хватает. Это можно определить только на станке, имея электросхему.

Поделиться сообщением


Ссылка на сообщение

  •  #15

tmpr,

:yahoo:Нашли.! Сработала теплушка насоса подачи СОЖ. А на неё заведены контакты подготовки готовности оборудования, и при опросе контроллер находил неисправность цепи и не давал готовности.=Ну вот как то так мы разложили эту организацию управления. :rolleyes:=

Спасибо за участие в поиска проблемы :hi:

Поделиться сообщением


Ссылка на сообщение

  •  #16

Может и мне кто подскажет. При работе токарного  станка на стойке синусному 808 выскакивает ошибка 700000 аварийное сообщение пользователя 01

Поделиться сообщением


Ссылка на сообщение

  •  #17

19 часов назад, Alex9119 сказал:

аварийное сообщение пользователя 01

Пользователь в данной ситуации это производитель станка. Описание ошибки  в его документации, а не  Сименса.

Поделиться сообщением


Ссылка на сообщение

  •  #18

В 26.08.2022 в 12:53, Вал сказал:

Пользователь

Но в этот момент на частотнике появляется ошибка err 06, ее прям на нем сбрасываешь, потом на пульте сбрасываешь ошибку и все работает. Ошибка возникает при торможении, т.е смене оборотов на более низкие или выключении оборотов

В 26.08.2022 в 12:53, Вал сказал:

ошибки

Завод отвечает, что это отказ шпинделя, просят снять кучу разных видео с ошибкой и без и ждать

Поделиться сообщением


Ссылка на сообщение

  •  #19

13 часов назад, Alex9119 сказал:

на частотнике появляется ошибка

Намекает на изучение инструкции к частотнику.

Поделиться сообщением


Ссылка на сообщение

Для публикации сообщений создайте учётную запись или авторизуйтесь

Вы должны быть пользователем, чтобы оставить комментарий

Войти

Уже есть аккаунт? Войти в систему.

Войти


  • Последние посетители

      0 пользователей онлайн

    Ни одного зарегистрированного пользователя не просматривает данную страницу

Myp1cBel_ru

%_N_MYPLC_UK_COM

;$PATH=/_N_MB_DIR

700000
0 0 «Приводы станка не
готовы»

700001
0 0 «Выключился защитный
автомат двигателя гидравлики»

700002
0 0 «Выключился некоторый
защитный автомат асинхронных двигателей»

700003
0 0 «Ошибка смазки
направляющей нижнего суппорта
«

700004
0 0 «Ошибка смазки
направляющей задней бабки»

700005
0 0 «Ошибка смазки
направляющей верхнего суппорта»

700006
0 0 «Ошибка смазочной
константы 14510[0] <200-990>»

700007
0 0 «Количество смазочных
впрысков вне диапазона 14510[1]
<1-5>»

700008
0 0 «Ошибка смазки блоков
люнета»

700009
0 0 «Ошибка смазочной
константы 14510[4] <60 — 990>»

700010
0 0 «Перемена зажимного
режима при M3/M4»

700011
0 0 «Старт главного
шпинделя и деталь не зажата»

700013
0 0 «Ошибка положения
зажимного цилиндра патрона при M3/M4»

700014
0 0 «Ошибка давления
зажимного цилиндра патрона при M3/M4»

700020
0 0 «Ошибка положения
пиноли задней бабки при M3/M4»

700021
0 0 «Ошибка давления
пиноли задней бабки при M3/M4»

700022
0 0 «Задняя бабка в левом
лимитном положении»

700023
0 0 «M62/M63/M64 и пиноль
задней бабки не задвинута»

700024
0 0 «Временной контроль
за функцией M62/M63/M64»

700025
0 0 «M66 — а шпиндель
работает»

700027
0 0 «Временной контроль
функции M65 или M66»

700032
0 0 «Сжатая кнопка C-STOP»

700033
0 0 «Станок выключен»

700034
0 0 «Аварийные выключатели
шунтированы»

700035 0 0 «Аварийное положение оси +X»

700036 0 0 «Аварийное положение оси -X»

700037 0 0 «Аварийное положение оси +Z»

700038 0 0 «Аварийное положение оси -Z»

700039 0 0 «Аварийное положение оси +W»

700040 0 0 «Аварийное положение оси -W»

700041
0 0 «Приводы блокированы
открытым кожухом»

700042
0 0 «Низкий уровень
гидравлического масла»

700043
0 0 «Загрязненный фильтр
гидравлического масла»

700044
0 0 «Низкий уровень
смазочного масла»

700045
0 0 «Низкий уровень
смазочного масла блоков люнета»

700046
0 0 «CNC не готова»

700047 0 0 «Корпус люнета не выдвинут
относительно обрабатываемой детали»

700048
0 0 «Сухари люнета
несовершенно разжаты»

700049
0 0 «Низкое зажимное
давление люнета»

700050
0 0 «Зажимной цилиндр
патрона в крайнем положении»

700051
0 0 «Низкое давление в
зажимном цилиндре патрона»

700052
0 0 «Пиноль задней бабки
в левом лимитном положении»

700053
0 0 «Низкое давление
пиноли задней бабки»

700054
0 0 «Корпус задней бабки
в левом крайнем положении»

700055
0 0 «Пиноль не задвинута
— корпус задней бабки нельзя перемещать»

700056
0 0 «Эталонируй оси или
после RESET позволено движение осей»

700059
0 0 «Старт цикла блокирован
положением зам. кнопки кожуха»

700060
0 0 «Инструментальная
головка не вышла в позицию»

700100
0 0 «Ошибка четности
кода позиции инструментальной головки»

700101
0 0 «Заданная позиция
инструментальной головки вне диапазона»

700103
0 0 «Функция люнета
ошибочная в отношении к его состоянию»

700104
0 0 «Ошибка давления
сухарей люнета при M3/M4»

700105
0 0 «Временной контроль
за арретированием инструментальной
головки»

700106
0 0 «Временной контроль
за вращением инструментальной головки»

700108
0 0 «Временной контроль
за функцией люнета «

700109
0 0 «M79, a шпиндель работает»

700110 0 0 «Ошибка управления кожухом»

700111
0 0 «Защитные рейки
кожуха были нажаты»

700112
0 0 «Временной контроль
за функцией M51 или M52»

700115 0 0 «Временной
контроль за функцией SPOS — установка
позиции главного шпинделя
«

700116 0 0 «Функции
М3 / М4 и режим оси С — активный»

700117
0 0 «Временной контроль
за функцией М14 или M15»

700118
0 0 «М14 — а ось С не
находится в эталонном положении»

700119
0 0 «M14 — а шпиндель не
ориентирован «

700120 0 0 «Временной контроль за
переключением — функция M41/M42»

700121
0 0 «M41/M42 — а главный
шпиндель находится в режиме оси C»

700125
0 0 «Временной контроль
за ориентацией инструментального
шпинделя»

700126
0 0 «Перегрузка двигателя
транспортера стружки»

700127
0 0 «Ошибка измерительного
щупа»

700132
0 0 «Слабая батарея щупа»

700134
0 0 «Стоп перемещения
осей переключателем»

700135
0 0 «Стоп перемещения
осей и шпинделя переключателем»

700136
0 0 «Действительная
скорость вращения главного шпинделя
слишком высока»

700138
0 0 «Не достигнуто
заданное число оборотов главного
шпинделя»

700139
0 0 «Действительные
обороты инструментального шпинделя
слишком высоки»

700141
0 0 «Заданная скорость
вращения инструментального шпинделя
не достигнута»

700143
0 0 «Стоп оборотов с
ручного переносного пульта»

700144
0 0 «Стоп подач с ручного
переносного пульта»

700145
0 0 «Двигатель оси С — в
промежуточном положении»

700146
1 0 «Не установлена
ступень переключения для главного
шпинделя»

700149
0 0 «Функция M2=3/M2=4 и
T-функции программированы в одном блоке»

M02

Соседние файлы в папке RUSTINA

  • #
  • #

Только что, David123 сказал:

Уважаемый @nein !

1) Насколько я понял, Вы умеете обращаться с архивами, первым делом сохраните текущий архив NC.

2) Ошибку 700004 — выдает электроавтоматика станка. Она должна быть описана в Руководстве по станку. Что там сказано?

3)  Эта ошибка всегда выводится или ранее станок работал, выдавал готовую продукцию, но произошли какие-то обстоятельства, после чего происходит описываемое.

4) Эта ошибка выводится сразу после первоначальной загрузки системы или какие-то действия производятся на станке? Нет ли в строке вывода ошибки, сразу после номера 700004 символа «стрелка вниз». Это признак — одновременно появились несколько ошибок или сообщений. В области ДИАГНОСТИКА можно найти полный их список. Сделайте их фото.

5) Есть ли у Вас проект (не архив) электроавтоматики станка?

Уважаемый@David123 , большое спасибо, что пытаетесь помочь.

1) Текущий архив NC я сразу сохранил.

2) Там сказано — замените предохранитель или включите автомат.

3) Начну с самого начала. Мы купили станок в Турции. Когда он приехал, он включился, но выдавал другие ошибки. Включался свет в рабочей зоне от кнопки. Выяснилось, что там не было заглушки на разъёме подключения податчика прутка. Я стал ставить заглушку, но в процессе перевозки или погрузки станка этот разъём был сломан. В результате там что-то перемкнулось, и теперь выпадает такая ошибка про предохранитель. Разъём мы заменили, цепи прозвонили — всё нормально. Но теперь ошибка не уходит. Свет не включается.

Теперь вернусь к автоматам. Все цепочки — нормальные. На фотографии 1 на модуле 9А3 горят светодиоды B2.7 и B3.0 — т.е. все автоматы нормальные. На фотографии 2 на блоке питания 9А1 постоянно горит красный светодиод FAULT. На фотографии 1 видно, что горят светодиоды на модулях 9А3 и 9А4 (это если мы правильно понимаем, входные цепи для 9А1) и не горят на выходном модуле 9А5. Сам блок 9А1 мы меняли (брали точно такой же с соседнего рабочего станка) — ничего не менялось. X3/IN — это связь с PLC.

4) Ошибка выпадает сразу при загрузке. Я разговаривал с сервисником Шпиннера из Болгарии, он сказал, что все остальные ошибки — это производные от 700004. Завтра сделаю фото области «диагностика».

5) Нет, проекта у меня нет.

1.jpg

2.jpg

ошибки.jpeg

  • 8 Июн 2021

Здравствуйте Всем. Появилась очередная проблема на этом станке при выводе в референсные точки пишет ошибки 700032 и 700037 что может быть и куда копать?

  • 9 Июн 2021

igorin5, ошибки 700XXX — это ошибки прописанные изготовителем станка. Для каждого станка они разные. Описание этих ошибок у вас есть?

  • 9 Июн 2021

Всем спасибо. Разобрались сами кому интересно неисправен был блок безопасности XPS-AT5110. Тему закрываю.

  • 8 Окт 2021

igorin5, У нас на станке TUR630MN слетели системные файлы до заводских настроек. Ищу архивные файлы NC и PLC для восстановления. Сможете чем-то помочь?

  • 20211005_170758.jpg

    20211005_170758.jpg

    615,9 КБ

    · Посмотрено: 52

  • 20211005_202614.jpg

    20211005_202614.jpg

    312,7 КБ

    · Посмотрено: 50

  • TUR630MN_60129.jpg

    TUR630MN_60129.jpg

    366,4 КБ

    · Посмотрено: 47

  • 8 Окт 2021

Sergey_Ka сказал(а):

igorin5, У нас на станке TUR630MN слетели системные файлы до заводских настроек. Ищу архивные файлы NC и PLC для восстановления. Сможете чем-то помочь?

Вы не могли бы выразится поточнее что не так? PLC у вас точно работает, только самих текстов ошибок 700002 и 700048 не видно

  • 12 Окт 2021

Lucky сказал(а):

Sergey_Ka сказал(а):

igorin5, У нас на станке TUR630MN слетели системные файлы до заводских настроек. Ищу архивные файлы NC и PLC для восстановления. Сможете чем-то помочь?

Вы не могли бы выразится поточнее что не так? PLC у вас точно работает, только самих текстов ошибок 700002 и 700048 не видно

Да, PLC работает. Включает гидравлику, СОЖ, смазку направляющих и стружкоуборщик. Но слетела конфигурация. Появилась Ось Y и показания номера инструмента «Т» постоянно хаотически изменяются сами собой.

  • 12 Окт 2021

Sergey_Ka сказал(а):

Да, PLC работает. Включает гидравлику, СОЖ, смазку направляющих и стружкоуборщик. Но слетела конфигурация. Появилась Ось Y и показания номера инструмента «Т» постоянно хаотически изменяются сами собой.

Ось Y легко убрать параметрами. А вот с номером инструмента разбирайтесь — ищите пропадающие или лишние контакты из-за СОЖ

Remedy

Check whether the chuck control key on the MCP is activated (the indicator is

lit).

Check whether the workpiece is clamped in the chuck on the machine.

Check the interface X102 on the back of the PPU for the following:

Whether the connection of pin 5 is loose/broken

Whether pin 10 is connected to 0 V properly

4.3.2

Alarm description

No chuck operation is allowed when the spindle or the part program is running.

PLC information

PLC address: DB1600.DBX2.1

Subroutine: MAIN (OB1)

Remedy

Press this key on the PPU to cancel the alarm, and the program will continue.

You can also press this key on the MCP to cancel the alarm.

Note: The program execution is also reset in this case.

4.3.3

Alarm 700022

Alarm description

This alarm appears because the turret motor is overloaded, and the turret function cannot be used normally. In this case, all

operations are not available.

PLC information

PLC address: DB1600.DBX2.6

Subroutine: MAIN (OB1)

Remedy

● Check whether the overload protection switch of the turret motor works.

● Check the interface X102 on the back of the PPU for the following:

Whether the connection of pin 2 is loose/broken

Whether pin 10 is connected to 0 V properly

Service Manual

01/2017

41

  • 16000 Channel %1 block %2 invalid value for lifting direction
  • 16005 Channel %1 block %2 invalid value for lifting distance
  • 16010 Channel %1 block %2 machining stop after lift fast
  • 16015 Channel %1 block %2 wrong axis identifier %3
  • 16016 Channel %1 block %2 no retraction position programmed for axis %3
  • 16020 Channel %1 repositioning in block %2 is not possible
  • 16100 Channel %1 block %2 spindle %3 not available in the channel
  • 16105 Channel %1 block %2 spindle %3 cannot be assigned
  • 16110 Channel %1 block %2 spindle %3 for dwell time not in control mode
  • 16120 Channel %1 block %2 invalid index for tool fine compensation
  • 16130 Channel %1 block %2 instruction not allowed with FTOCON
  • 16140 Channel %1 block %2 FTOCON not allowed
  • 16150 Channel %1 block %2 invalid spindle number with PUTFTOCF
  • 16200 Channel %1 block %2 spline and polynominal interpolation not available
  • 16300 Channel %1 block %2 denominator polynominal with zero places within parameter range not allowed
  • 16400 Channel %1 block %2 positioning axis %3 cannot participate in spline
  • 16410 Channel %1 block %2 axis %3 is not a geometry axis
  • 16420 Channel %1 block %2 axis %3 programmed repeatedly
  • 16421 Channel %1 block %2 angle %3 programmed repeatedly in the block
  • 16422 Channel %1 block %2 angle %3 programmed repeatedly in the block
  • 16423 Channel %1 block %2 angle %3 programmed repeatedly in the block
  • 16424 Channel %1 block %2 coordinate %3 programmed repeatedly in the block
  • 16430 Channel %1 block %2 geometry axis %3 cannot traverse as positioning axis in rotated coordinate system
  • 16440 Channel %1 block %2 rotation programmed for non-existent geometry axis
  • 16500 Channel %1 block %2 chamfer or rounding negative
  • 16510 Channel %1 block %2 no facing axis available
  • 16700 Channel %1 block %2 axis %3 invalid feed type
  • 16710 Channel %1 block %2 axis %3 master spindle not programmed
  • 16715 Channel %1 block %2 axis %3 spindle not in standstill
  • 16720 Channel %1 block %2 axis %3 thread lead is zero
  • 16730 Channel %1 block %2 axis %3 wrong parameter
  • 16740 Channel %1 block %2 no geometry axis programmed
  • 16750 Channel %1 block %2 axis %3 SPCON not programmed
  • 16751 Channel %1 block %2 spindle/axis %3 SPCOF not executable
  • 16755 Channel %1 block %2 no stop required
  • 16760 Channel %1 block %2 axis %3 S value missing
  • 16761 Channel %1 block %2 axis/spindle %3 not programmable in the channel
  • 16762 Channel %1 block %2 spindle %3 thread function is active
  • 16763 Channel %1 block %2 axis %3 programmed speed is illegal (zero or negative)
  • 16770 Channel %1 block %2 axis %3 no measuring system available
  • 16771 Channel %1 following axis %2 overlaid movement not enabled
  • 16776 Channel %1 block %2 curve table %3 does not exist for axis %4
  • 16777 Channel %1 block %2 coupling: following axis %3 for lead axis %4 not available
  • 16778 Channel %1 block %2 coupling: Ring coupling at following axis %3 and leading axis %4 impermissible
  • 16779 Channel %1 block %2 coupling: too many couplings for axis %3, see active leading axis %4
  • 16780 Channel %1 block %2 following spindle/axis missing
  • 16781 Channel %1 block %2 master spindle/axis missing
  • 16782 Channel %1 block %2 following spindle/axis %3 not available
  • 16783 Channel %1 block %2 master spindle/axis %3 not available
  • 16785 Channel %1 block %2 identical spindles/axes %3
  • 16787 Channel %1 block %2 coupling parameter not changeable
  • 16788 Channel %1 block %2 cyclic coupling
  • 16789 Channel %1 block %2 multiple link
  • 16790 Channel %1 block %2 Parameter is zero or missing
  • 16791 Channel %1 block %2 parameter is not relevant
  • 16792 Channel %1 block %2 too many couplings for axis/spindle %3
  • 16793 Channel %1 block %2 coupling of axis %3 prohibits transformation change
  • 16794 Channel %1 block %2 coupling of axis/spindle %3 prohibits reference point approach
  • 16795 Channel %1 block %2 string cannot be interpreted
  • 16796 Channel %1 block %2 coupling not defined
  • 16797 Channel %1 block %2 coupling is active
  • 16798 Channel %1 block %2 axis %3 is following axis and prohibits axis container rotation
  • 16799 Channel %1 block %2 axis %3 is master axis and prohibits axis container rotation
  • 16800 Channel %1 block %2 traverse instruction DC/CDC for axis %3 not allowed
  • 16810 Channel %1 block %2 traverse instruction ACP for axis %3 not allowed
  • 16820 Channel %1 block %2 traverse instruction ACN for axis %3 not allowed
  • 16830 Channel %1 block %2 incorrect position programmed for axis/spindle %3
  • 16903 Channel %1 program control: action %2 not allowed in the current state
  • 16904 Channel %1 program control: action %2 not allowed in the current state
  • 16905 Channel %1 program control: action %2 not allowed
  • 16906 Channel %1 program control: action %2 is aborted due to an alarm
  • 16907 Channel %1 action %2 only possible in stop state
  • 16908 Channel %1 action %2 only possible in reset state or at the block end
  • 16909 Channel %1 action %2 not allowed in current mode
  • 16911 Channel %1 mode change is not allowed
  • 16912 Channel %1 program control: action %2 only possible in reset state
  • 16913 Mode group %1 channel %2 mode change: action %3 not allowed
  • 16914 Mode group %1 channel %2 mode change: action %3 not allowed
  • 16915 Channel %1 action %2 not allowed in the current block
  • 16916 Channel %1 repositioning: action %2 not allowed in the current state
  • 16918 Channel %1 for action %2 all channels must be in reset state
  • 16919 Channel %1 action %2 is not allowed due to a pending alarm
  • 16920 Channel %1 action %2 is already active
  • 16921 Channel %1 mode group %2 machine data: channel/mode group assignment not allowed or assigned twice
  • 16922 Channel %1 subprograms: action %2 maximum nesting depth exceeded
  • 16923 Channel %1 program control: action %2 not allowed in the current state
  • 16924 Channel %1 caution: program test modifies tool management data
  • 16925 Channel %1 program control: action %2 not allowed in the current state, action %3 active
  • 16926 Channel %1 channel coordination: action %2 not allowed in block %3, marker %4 is already set
  • 16927 Channel %1 action %2 at active interrupt treatment not allowed
  • 16928 Channel %1 interrupt treatment: action %2 not possible
  • 16930 Channel %1: preceding block and current block %2 must be separated through an executable block
  • 16931 Channel %1 subprograms: action %2 maximum nesting depth exceeded
  • 16932 Channel %1 conflict when activating user data type %2
  • 16933 Channel %1 interrupt treatment: action %2 not allowed in the current state
  • 16934 Channel %1 interrupt treatment: action %2 not possible due to stop
  • 16935 Channel %1 action %2 not possible due to search run
  • 16936 Channel %1 action %2 not possible due to active dry run
  • 16937 Channel %1 action %2 not possible due to program test
  • 16938 Channel %1 action %2 aborted due to active gear change
  • 16939 Channel %1 action %2 rejected due to active gear change
  • 16940 Channel %1 action %2 wait for gear change
  • 16941 Channel %1 action %2 rejected because no program event has been executed yet
  • 16942 Channel %1 start program command action %2 not possible
  • 16943 Channel %1 action %2 not possible due to ASUP
  • 16944 Channel %1 action %2 not possible due to active search blocks
  • 16945 Channel %1 action %2 delayed up to the block end
  • 16946 Channel %1 start via START is not allowed
  • 16947 Channel %1 start via PLC is not allowed
  • 16948 Channel %1 dependent channel %2 still active
  • 16949 Correspondence between marker of channel %1 and channel %2 is invalid.
  • 16950 Channel %1 search run with hold block
  • 16951 Channel %1 search run in a program section that cannot be searched
  • 17000 Channel %1 block %2 maximum number of symbols exceeded
  • 17001 Channel %1 block %2 no memory left for tool/magazine data
  • 17010 Channel %1 block %2 no memory left
  • 17020 Channel %1 block %2 illegal array index 1
  • 17030 Channel %1 block %2 illegal array index 2
  • 17040 Channel %1 block %2 illegal axis index
  • 17050 Channel %1 block %2 illegal value
  • 17055 Channel %1 block %2 GUD variable not existing
  • 17060 Channel %1 block %2 requested data area too large
  • 17070 Channel %1 block %2 data is write-protected
  • 17080 Channel %1 block %2 %3 value below lower limit
  • 17090 Channel %1 block %2 %3 value exceeds upper limit
  • 17095 Channel %1 block %2 invalid value
  • 17100 Channel %1 block %2 digital input/comparator no. %3 not activated
  • 17110 Channel %1 block %2 digital output no. %3 not activated
  • 17120 Channel %1 block %2 analog input no. %3 not activated
  • 17130 Channel %1 block %2 analog output no. %3 not activated
  • 17140 Channel %1 block %2 NCK output %3 is assigned to a function via machine data
  • 17150 Channel %1 block %2 maximum of %3 NCK outputs programmable in the block
  • 17160 Channel %1 block %2 no tool selected
  • 17170 Channel %1 block %2 number of symbols too large
  • 17180 Channel %1 block %2 illegal D number
  • 17181 Channel %1 block %2 T no.= %3, D no.= %4 not existing
  • 17182 Channel %1 block %2 illegal sum correction number
  • 17188 Channel %1 D number %2 defined in tool T no. %3 and %4
  • 17189 Channel %1 D number %2 of tools defined on magazine/location %3 and %4
  • 17190 Channel %1 block %2 illegal T number
  • 17191 Channel %1 block %2 T= %3 not existing, program %4
  • 17192 TO unit %1 invalid tool designation of ‘%2’, duplo no. %3. No more replacement tools possible in ‘%4’.
  • 17193 Channel %1 block %2 the active tool is no longer on toolholder no./spindle no. %3, program %4
  • 17194 Channel %1 block %2 no suitable tool found
  • 17200 Channel %1 block %2 deleting tool data not possible
  • 17202 Channel %1 block %2 deleting magazine data not possible
  • 17210 Channel %1 block %2 access to variable not possible
  • 17212 Channel %1 tool management: Load manual tool %3, duplo no. %2 onto spindle/ toolholder %4
  • 17214 Channel %1 tool management: remove manual tool %3 from spindle/toolholder %2
  • 17216 Channel %1 tool management: remove manual tool from spindle/toolholder %4 and load manual tool %3, duplo no. %2
  • 17220 Channel %1 block %2 tool not existing
  • 17230 Channel %1 block %2 Duplo no. already assigned
  • 17240 Channel %1 block %2 illegal tool definition
  • 17250 Channel %1 block %2 illegal magazine definition
  • 17260 Channel %1 block %2 illegal magazine location definition
  • 17262 Channel %1 block %2 illegal tool adapter operation
  • 17270 Channel %1 block %2 call-by-reference: illegal variable
  • 17500 Channel %1 block %2 axis %3 is not an indexing axis
  • 17501 Channel %1 block %2 indexing axis %3 with Hirth tool system is active
  • 17502 Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed
  • 17503 Channel %1 block %2 indexing axis %3 with Hirth tooth system and axis not referenced
  • 17510 Channel %1 block %2 invalid index for indexing axis %3
  • 17600 Channel %1 block %2 preset on transformed axis %3 not possible
  • 17605 Channel %1 block %2 axis %3 transformation active: inhibits rotation of axis container
  • 17610 Channel %1 block %2 axis %3 involved in the transformation, action cannot be carried out
  • 17620 Channel %1 block %2 approaching fixed point for transformed axis %3 not possible
  • 17630 Channel %1 block %2 referencing for transformed axis %3 not possible
  • 17640 Channel %1 block %2 spindle operation for transformed axis %3 not possible
  • 17650 Channel %1 block %2 machine axis %3 not programmable
  • 17800 Channel %1 block %2 illegally coded position programmed
  • 17900 Channel %1 block %2 axis %3 is no machine axis
  • 18000 Channel %1 block %2 NCK-specific protection zone %3 wrong. Error code %4
  • 18001 Channel %1 block %2 channel-specific protection zone %3 incorrect. Error code %4
  • 18002 Channel %1 block %2 NCK protection zone %3 cannot be activated. Error code %4
  • 18003 Channel %1 block %2 NCK protection zone %3 cannot be activated.Error code %4
  • 18004 Channel %1 block %2 orientation of workpiece-related protection zone %3 does not correspond to the orientation of tool-related protection zone %4
  • 18005 Channel %1 block %2 serious error in definition of NCK-specific protection zone %3
  • 18006 Channel %1 block %2 serious error in definition of channel-specific protection zone %3
  • 18100 Channel %1 block %2 invalid value assigned to FXS[]
  • 18101 Channel %1 block %2 invalid value assigned to FXST[]
  • 18102 Channel %1 block %2 invalid value assigned to FXSW[]
  • 18200 Channel %1 block %2 curve table: block search stop not allowed with definition CTABDEF
  • 18201 Channel %1 block %2 curve table: table %3 does not exist
  • 18202 Channel %1 block %2 curve table: instruction CTABEND without CTABDEF not allowed
  • 18300 Channel %1 block %2 frame: fine shift not possible
  • 18310 Channel %1 block %2 frame: illegal rotation
  • 18311 Channel %1 block %2 frame: illegal instruction
  • 18312 Channel %1 block %2 frame: fine shift not configured
  • 18313 Channel %1 block %2 frame: illegal switchover of geometry axes
  • 18314 Channel %1 block %2 frame: type conflict
  • 18400 Channel %1 block %2 language change not possible:
  • 20000 Channel %1 axis %2 reference cam not reached
  • 20001 Channel %1 axis %2 no cam signal present
  • 20002 Channel %1 axis %2 zero mark not found
  • 20003 Channel %1 axis %2 measuring system error
  • 20004 Channel %1 axis %2 reference mark missing
  • 20005 Channel %1 axis %2 reference point approach aborted
  • 20006 Channel %1 axis %2 reference point creep velocity not reached
  • 20007 Channel %1 axis %2 reference point approach requires 2 measuring systems
  • 20008 Channel %1 axis %2 reference point approach requires second referenced measuring system
  • 20050 Channel %1 axis %2 handwheel mode active
  • 20051 Channel %1 axis %2 handwheel mode not possible
  • 20052 Channel %1 axis %2 already active
  • 20053 Channel %1 axis %2 DRF, FTOCON, external zero point offset not possible
  • 20054 Channel %1 axis %2 wrong index for indexing axis in JOG mode
  • 20055 Channel %1 master spindle not present in JOG mode
  • 20056 Channel %1 axis %2 no revolutional feedrate possible. Axis/spindle %3 stationary
  • 20057 Channel %1 block %2 revolutional feedrate for axis/spindle %3 is <= zero
  • 20058 Channel %1 axis %2 revolutional feedrate: illegal feed source
  • 20060 Channel %1 axis %2 cannot be traversed as geometry axis
  • 20061 Channel %1 axis %2 cannot be traversed as orientation axis
  • 20062 Channel %1 axis %2 already active
  • 20063 Channel %1 axis %2 orientation axes cannot be traversed without transformation
  • 20065 Channel %1 master spindle not defined for geometry axes in JOG mode
  • 20070 Channel %1 axis %2 programmed end position is behind software limit switch %3
  • 20071 Channel %1 axis %2 programmed end position is behind working area limit %3
  • 20072 Channel %1 axis %2 is not an indexing axis
  • 20073 Channel %1 axis %2 cannot be repositioned
  • 20074 Channel %1 axis %2 wrong index position
  • 20075 Channel %1 axis %2 can currently not oscillate
  • 20076 Channel %1 axis %2 oscillating – mode change not possible
  • 20077 Channel %1 axis %2 programmed position is behind software limit switch %3
  • 20078 Channel %1 axis %2 programmed position is behind working area limit %3
  • 20079 Channel %1 axis %2 oscillation path length %3 <= 0
  • 20080 Channel %1 axis %2 no handwheel assigned for overlaid motion
  • 20085 Channel %1 contour handwheel: traverse direction or overtravel of beginning of block not allowed
  • 20090 Axis %1 travel to fixed stop not possible. Check programming and axis data.
  • 20091 Axis %1 has not reached fixed stop
  • 20092 Axis %1 travel to fixed stop still active
  • 20093 Axis %1 standstill monitoring at fixed-stop end point has been triggered
  • 20094 Axis %1 function has been aborted
  • 20095 Axis %1 illegal torque, current torque %2
  • 20096 Axis %1 brake test aborted, additional information %2
  • 20100 Channel %1: invalid configuration for digitizing function
  • 20101 Communication with the digitizer not possible
  • 20102 Channel %1: No or invalid trafo at digitizing active
  • 20103 Channel %1: digitizing module does not support 3+2 axis digitizing
  • 20105 Channel %1: axes stopped by digitizer. Error code: %2
  • 20106 Emergency stop set by the digitizer
  • 20108 Invalid data package received from the digitizer. Error codes: %1, %2
  • 20109 Error in communication with the digitizer: status code of com-circuit: %1
  • 20120 Axis %1: too many compensation relations
  • 20121 Axis %1: Configuration error in compensation table %2
  • 20122 Compensation table %1: invalid axis assignment
  • 20123 Axis %1: different output assignment of multiplied tables
  • 20124 Axis %1: sum of compensation values too large
  • 20125 Axis %1: change of compensation value is too rapid
  • 20130 Channel %1 contour tunnel monitoring
  • 20140 Channel %1 motion synchronous action: traversing of command axis %2 see NC alarm %3
  • 20141 Channel %1 motion synchronous action: illegal axis type
  • 20142 Channel %1 command axis %2: rotation of axis container already enabled
  • 20143 Channel %1 axis %2 command axis cannot be started as it is controlled by the PLC
  • 20144 Channel %1 block %2 motion synchronous action: system variable access not possible
  • 20145 Channel %1 block %2 motion synchronous action: arithmetic error
  • 20146 Channel %1 block %2 motion synchronous action: nesting depth exceeded
  • 20147 Channel %1 block %2 motion synchronous action: command not executable
  • 20148 Channel %1 block %2 motion synchronous action: internal error %3
  • 20149 Channel %1 block %2 motion synchronous action: illegal index
  • 20150 Channel %1 tool management: PLC terminates interrupted command
  • 20160 Channel %1 tool management: PLC can terminate only incorrectly aborted commands
  • 20170 Channel %1 machine data $AC_FIFO invalid
  • 20200 Channel %1 invalid spindle number %2 with tool fine compensation
  • 20201 Channel %1 spindle %2 no tool assigned
  • 20203 Channel %1 no active tool
  • 20204 Channel %1 PUTFTOC command not allowed with FTOCOF
  • 20210 Channel %1 block %3 spindle %2 wrong values for centerless grinding
  • 20211 Channel %1 block %3 spindle %2 support point beyond range limits
  • 21600 Monitoring for ESR active
  • 21610 Channel %1 axis %2 encoder %3 frequency limit exceeded
  • 21611 Channel %1 NC-controlled Extended Stop/Retract triggered
  • 21612 Channel %1 axis %2 VDI signal ‘Servo enable’ reset during motion
  • 21613 Axis %1 measuring system changing
  • 21614 Channel %1 axis %2 hardware limit switch %3
  • 21615 Channel %1 axis %2 taken from traverse mode to follow-up mode
  • 21616 Channel %1 block %2 overlaid motion active at transformation switchover
  • 21617 Channel %1 block %2 transformation does not allow to traverse the pole
  • 21618 Channel %1 as from block %2 transformation active: overlaid motion too great
  • 21619 Channel %1 block %2 transformation active: motion not possible
  • 21650 Channel %1 axis %2 overlaid motion not allowed
  • 21660 Channel %1 block %2 axis %3 conflict between SYNACT: $AA_OFF and CORROF
  • 21665 Channel %1 $AA_TOFF cleared
  • 21670 Channel %1 block %2 illegal change of tool direction with $AA_TOFF active
  • 21700 Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible
  • 21701 Channel %1 block %3 axis %2 measurement not possible
  • 21702 Channel %1 block %3 axis %2 measurement aborted
  • 21703 Channel %1 block %3 axis %2 touch probe not deflected, illegal edge polarity
  • 21740 Output value at analog output no. %1 has been limited
  • 21750 Error during output of cam signals via timer
  • 21760 Channel %1 block %2 too many auxiliary functions programmed
  • 21800 Channel %1 workpiece setpoint %2 reached
  • 22000 Channel %1 block %3 spindle %2 change of gear stage not possible
  • 22010 Channel %1 block %3 spindle %2 actual gear stage differs from requested gear stage
  • 22011 Channel %1 block %3 spindle %2 change to programmed gear stage not possible
  • 22012 Channel %1 block %2 leading spindle %3 is in simulation.
  • 22013 Channel %1 block %2 dependent spindle %3 is in simulation.
  • 22014 Channel %1 block %2. The dynamics of leading spindle %3 and dependent spindle %4 is too variably
  • 22020 Channel %1 block %3 spindle %2 gear step change position not reached
  • 22040 Channel %1 block %3 spindle %2 is not referenced with zero marker
  • 22045 Block %2 spindle/axis %3 not available in channel %1 because active in channel %4
  • 22050 Channel %1 block %3 spindle %2 no transition from speed control mode to position control mode
  • 22051 Channel %1 block %3 spindle %2 reference mark not found
  • 22052 Channel %1 block %3 spindle %2 no standstill on block change
  • 22053 Channel %1 block %3 spindle %2 reference mode not supported
  • 22054 Channel %1 block %3 spindle %2 improper punching signal
  • 22055 Channel %1 block %3 spindle %2 configured positioning speed is too high
  • 22060 Channel %1 position control expected for axis/spindle %2
  • 22062 Channel %1 axis %2 reference point approach: zero marker search velocity (MD) is not reached
  • 22064 Channel %1 axis %2 reference point approach: zero marker search velocity (MD) is too high
  • 22065 Channel %1 tool management: Tool motion is not possible, as tool %2 with Duplo no. %3 is not in magazine %4
  • 22066 Channel %1 tool management: Tool change is not possible, as tool %2 with Duplo no. %3 is not in magazine %4
  • 22067 Channel %1 tool management: tool change not possible since there is no tool available in tool group %2
  • 22068 Channel %1 block %2 tool management: no tool available in tool group %3
  • 22069 Channel %1 block %2 tool management: No tool available in tool group %3, program %4
  • 22070 TO unit %1 Please change tool T= %2 into magazine. Repeat data backup
  • 22071 TO unit %1 tool %2 duplo no. %3 is active, but not in the magazine area under consideration
  • 22100 Channel %1 block %3 spindle %2 chuck speed exceeded
  • 22200 Channel %1 spindle %2 axis stopped during tapping
  • 22250 Channel %1 spindle %2 axis stopped during thread cutting
  • 22260 Channel %1 spindle %2 thread might be damaged
  • 22270 Channel %1 block %2 maximum velocity of thread axis at position %3 reached
  • 22275 Channel %1 block %2 zero velocity of thread axis at position %3 reached
  • 22280 Channel %1 in block %2: Prog. acceleration path too short %3, %4 required
  • 22320 Channel %1 block %2 PUTFTOCF command could not be transferred
  • 22321 Channel %1 axis %2 PRESET not allowed during traverse motion
  • 22322 Channel %1 axis %2 PRESET: illegal value
  • 25000 Axis %1 hardware fault of active encoder
  • 25001 Axis %1 hardware fault of passive encoder
  • 25010 Axis %1 pollution of measuring system
  • 25011 Axis %1 pollution of passive encoder
  • 25020 Axis %1 zero mark monitoring of active encoder
  • 25021 Axis %1 zero mark monitoring of passive encoder
  • 25022 Axis %1 encoder %2 warning %3
  • 25030 Axis %1 actual velocity alarm limit
  • 25031 Axis %1 actual velocity warning limit
  • 25040 Axis %1 standstill monitoring
  • 25042 Axis %1 standstill monitoring during torque/force limitation
  • 25050 Axis %1 contour monitoring
  • 25060 Axis %1 speed setpoint limitation
  • 25070 Axis %1 drift value too large
  • 25080 Axis %1 positioning monitoring
  • 25100 Axis %1 measuring system switchover not possible
  • 25105 Axis %1 measuring systems differ considerably
  • 25110 Axis %1 selected encoder not available
  • 25200 Axis %1 requested set of parameters invalid
  • 25201 Axis %1 drive fault
  • 25202 Axis %1 waiting for drive
  • 26000 Axis %1 clamping monitoring
  • 26001 Axis %1 parameterization error: friction compensation
  • 26002 Axis %1 encoder %2 parameterization error: number of encoder marks
  • 26003 Axis %1 parameterization error: lead screw pitch
  • 26004 Axis %1 encoder %2 parameterization error: grid point distance with linear encoders
  • 26005 Axis %1 parameterization error: output rating
  • 26006 Axis %1 encoder %2 encoder type/output type %3 not possible
  • 26007 Axis %1 QEC: invalid coarse step size
  • 26008 Axis %1 QEC: invalid fine step size
  • 26009 Axis %1 QEC: memory overflow
  • 26010 Axis %1 QEC: invalid acceleration characteristic
  • 26011 Axis %1 QEC: invalid measuring periods
  • 26012 Axis %1 QEC: feed forward control not active
  • 26014 Axis %1 machine data %2 invalid value
  • 26015 Axis %1 machine data %2[%3] invalid value
  • 26016 Axis %1 machine data %2 invalid value
  • 26017 Axis %1 machine data %2[%3] invalid value
  • 26018 Axis %1 setpoint output drive %2 used more than once
  • 26019 Axis %1 encoder %2 measurement not possible with this controller module
  • 26020 Axis %1 encoder %2 hardware fault %3 during encoder initialization
  • 26022 Axis %1 encoder %2 measurement with simulated encoder not possible
  • 26024 Axis %1 machine data %2 value changed
  • 26025 Axis %1 machine data %2[%3] value changed
  • 26030 Axis %1 encoder %2 absolute position lost
  • 26031 Axis %1 configuration error master-slave
  • 26032 Axis %1 master-slave not configured
  • 26050 Axis %1 parameter set change from %2 to %3 not possible
  • 26051 Channel %1 in block %2 unanticipated stop crossed in continuous path mode
  • 26052 Channel %1 in block %2: path velocity too high for auxiliary function output
  • 26070 Channel %1 axis %2 cannot be controlled by the PLC, max. number exceeded
  • 26072 Channel %1 axis %2 cannot be controlled by the PLC
  • 26074 Channel %1 switching off PLC control of axis %2 not allowed in the current state
  • 26080 Channel %1 retraction position of axis %2 not programmed or invalid
  • 26081 Channel %1 axis trigger of axis %2 was activated, but axis is not PLC- controlled
  • 26100 Axis %1 drive %2 sign of life missing
  • 26101 Axis %1 drive %2 communication failure
  • 26102 Axis %1 drive %2 sign of life missing
  • 26105 Drive of axis %1 not found
  • 26106 Encoder %2 of axis %1 not found
  • 26110 Independent drive stop/retract triggered
  • 27000 Axis %1 is not safely referenced
  • 27001 Axis %1 error in a monitoring channel, code %2, values: NCK %3, drive %4
  • 27002 Axis %1 test stop is running
  • 27003 Checksum error found: %1 %2
  • 27004 Axis %1, difference safe input %2, NCK %3, drive %4
  • 27005 Axis %1 error in data cross check: static actual value difference
  • 27006 Axis %1 Test ext. pulse deletion running
  • 27007 Axis %1 acceptance test mode is active
  • 27008 Axis %1 SW limit switch deactivated
  • 27010 Axis %1 tolerance for safe standstill exceeded
  • 27011 Axis %1 safe velocity exceeded
  • 27012 Axis %1 safe end position exceeded
  • 27013 Axis %1 safe braking ramp exceeded
  • 27020 Axis %1 stop E triggered
  • 27021 Axis %1 stop D triggered
  • 27022 Axis %1 stop C triggered
  • 27023 Axis %1 stop B triggered
  • 27024 Axis %1 stop A triggered
  • 27030 Axis %1 function not supported on this 611D module
  • 27031 Axis %1 limit value for safe velocity %2 at gear ratio %3 too large (max. %4)
  • 27032 Axis %1 checksum error of safe monitoring. Confirmation and re-test required!
  • 27033 Axis %1 parameterization of MD %2[%3] invalid
  • 27034 Parameterization of MD %1 invalid
  • 27090 Error in data cross check NCK-PLC, %1[%2], NCK: %3; %4 ALSI
  • 27091 Error in data cross check NCK PLC, stop of %1
  • 27092 Communication broken off during NCK PLC data cross check, error detected by %1
  • 27093 Checksum error NCK-SPL, %1, %2, %3
  • 27094 Write access to system variable %1 only allowed from NCK-SPL
  • 27095 %1 SPL protection not activated
  • 27096 SPL start not allowed
  • 27100 At least one axis is not safely referenced
  • 27101 Axis %1 difference in function safe operational stop, NCK: %2 drive: %3
  • 27102 Axis %1 difference in function safe velocity %2, NCK: %3 drive: %4
  • 27103 Axis %1 difference in function safe limit position %2, NCK: %3 drive: %4
  • 27104 Axis %1 difference in function safe cam plus %2, NCK: %3 drive: %4
  • 27105 Axis %1 difference in function safe cam minus %2, NCK: %3 drive: %4
  • 27106 Axis %1 difference in function safe velocity nx, NCK: %2 drive: %3
  • 27107 Axis %1 difference in function cam modulo monitoring, NCK: %2 drive: %3
  • 27124 Stop A triggered at least in 1 axis
  • 27200 PROFIsafe: cycle time %1 [ms] too long
  • 27201 PROFIsafe: MD %1[%2]: bus segment %3 error
  • 27202 PROFIsafe: MD %1[%2]: address %3 error
  • 27203 PROFIsafe: MD %1[%2]: SPL assignment error
  • 27204 PROFIsafe: double assignment MD %1[%2] – MD %3[%4]
  • 27220 PROFIsafe: Number of NCK F modules (%1) <> number of DP modules (%2)
  • 27221 PROFIsafe: NCK F module MD %1[%2] unknown
  • 27222 PROFI safe: S7 F module PROFI safe address %1 unknown
  • 27223 PROFIsafe: NCK F module MD %1[%2] is not a %3 module
  • 27224 PROFIsafe: F module MD %1[%2] – MD %3[%4]: double assignment of PROFIsafe address
  • 27225 PROFIsafe: slave %1, configuration error %2
  • 27240 PROFIsafe: DP M not running up, DP info: %1
  • 27241 PROFIsafe: DP M version different, NCK: %1, PLC: %2
  • 27242 PROFIsafe: F module %1, %2 faulty
  • 27250 PROFIsafe: configuration in DP M changed; error code %1 – %2
  • 27251 PROFIsafe: F module %1, %2 reports error %3
  • 27252 PROFIsafe: Slave %1, sign-of-life error
  • 27253 PROFIsafe: communication fault F master component %1, error %2
  • 27254 PROFIsafe: F module %1, error on channel %2; %3
  • 27255 PROFIsafe: F module %1, general error
  • 27256 PROFIsafe: Current cycle time %1 [ms] > parameterized cycle time
  • 27299 PROFIsafe: Diagnosis %1 %2 %3 %4
  • 28000 NCU link connection to all other NCUs of the link network has been aborted
  • 28001 NCU link connection to the NCU %1 of the link network has been aborted
  • 28002 Error on activation of machine data, NCU network-wide machine data were modified by NCU %1
  • 28004 NCU link: NCU %1 of the link network is not on the bus
  • 28005 NCU link: NCU %1 of the link network not running synchronously
  • 28007 NCU link: conflict in configuration data of NCU %1
  • 28008 NCU link: conflict in timer setting of NCU %1
  • 28009 NCU link: conflict in bus parameters of NCU %1
  • 28010 NCU link: the NCU %1 has not received a message
  • 28011 IPO time insufficient for NCU link. Link cycle time: %1
  • 28012 NCU link: synchronization cycle signal failure %1 times
  • 28020 NCU link: too many link axes configured %1
  • 28030 Serious alarm on NCU %1, axes in follow-up mode
  • 28031 Serious alarm on NCU %1 not yet acknowledged, axes still in follow-up mode
  • 28032 Emergency stop activated on NCU %1, axes in follow-up mode
  • 28033 Emergency stop on NCU % 1, axes still in follow-up mode
  • 29033 Channel %1 axis change of axis %2 not possible, PLC axis movement not yet completed
  • 60000 Channel %1 block %2:
  • 61000 Channel %1 block %2 no tool compensation active
  • 61001 Channel %1 block %2 thread lead incorrect
  • 61002 Channel %1 block %2 machining type wrongly defined
  • 61003 Channel %1 block %2 no feed programmed in the cycle
  • 61004 Channel %1 block %2 configuration geometry axis incorrect
  • 61005 Channel %1 block %2 3rd geometry axis not present
  • 61006 Channel %1 block %2 tool radius too large
  • 61007 Channel %1 block %2 tool radius too small
  • 61009 Channel %1 block %2 active tool number = 0
  • 61010 Channel %1 block %2 finishing allowance too large
  • 61011 Channel %1 block %2 scaling not allowed
  • 61012 Channel %1 block %2 different scaling on the plane
  • 61013 Channel %1 block %2 basic settings were changed, program cannot be executed
  • 61101 Channel %1 block %2 reference plane incorrectly defined
  • 61102 Channel %1 block %2 no spindle direction programmed
  • 61103 Channel %1 block %2 number of drillings is zero
  • 61104 Channel %1 block %2 contour violation of slots/long holes
  • 61105 Channel %1 block %2 cutter radius too large
  • 61106 Channel %1 block %2 number or distance of circular elements
  • 61107 Channel %1 block %2 first drilling depth incorrectly defined
  • 61108 Channel %1 block %2 illegal values for parameters _RAD1 and _DP1
  • 61109 Channel %1 block %2 parameter _CDIR incorrectly defined
  • 61110 Channel %1 block %2 finishing allowance at the base > depth infeed
  • 61111 Channel %1 block %2 infeed width > tool diameter
  • 61112 Channel %1 block %2 tool radius negative
  • 61113 Channel %1 block %2 parameter _CRAD for corner radius too large
  • 61114 Channel %1 block %2 machining direction G41/G42 incorrectly defined
  • 61115 Channel %1 block %2 approach or retract mode (straight line/circle/plane/space) incorrectly defined
  • 61116 Channel %1 block %2 approach or retraction path = 0
  • 61117 Channel %1 block %2 active tool radius <= 0
  • 61118 Channel %1 block %2 length or width = 0
  • 61119 Channel %1 block %2 nominal or core diameter incorrectly programmed
  • 61120 Channel %1 block %2 internal/external thread type not defined
  • 61121 Channel %1 block %2 number of teeth per cutting edge missing
  • 61122 Channel %1 block %2 safety clearance on the plane incorrectly defined
  • 61124 Channel %1 block %2 infeed width is not programmed
  • 61125 Channel %1 block %2 technology selection in parameter _TECHNO incorrectly defined
  • 61126 Channel %1 block %2 thread length too short
  • 61127 Channel %1 block %2 transmission ratio of tapping axis incorrectly defined (machine data)
  • 61128 Channel %1 block %2 dipping angle = 0 for dipping with oscillation or helix
  • 61180 Channel %1 block %2 no name assigned to swivel data block, although MD $MN_MM_NUM_TOOL_CARRIER > 1
  • 61181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)
  • 61182 Channel %1 block %2 name of swivel data block unknown
  • 61183 Channel %1 block %2 retraction mode GUD7 _TC_FR beyond value range 0… 2
  • 61184 Channel %1 block %2 no solution possible with current input angle values
  • 61185 Channel %1 block %2 no or incorrect (min > max) rotary axis angle ranges assigned
  • 61186 Channel %1 block %2 rotary axis vectors invalid –> Check installation and start-up of the swivel cycle CYCLE800
  • 61188 Channel %1 block %2 no axis name for the 1st axis assigned -> Check installation and start-up of the swivel cycle CYCLE800
  • 61200 Channel %1 block %2 too many elements in the machining block
  • 61201 Channel %1 block %2 wrong sequence in the machining block
  • 61202 Channel %1 block %2 no technology cycle
  • 61203 Channel %1 block %2 no positioning cycle
  • 61204 Channel %1 block %2 unknown technology cycle
  • 61205 Channel %1 block %2 unknown positioning cycle
  • 61210 Channel %1 block %2 block search element not found
  • 61211 Channel %1 block %2 absolute reference missing
  • 61212 Channel %1 block %2 wrong tool type
  • 61213 Channel %1 block %2 circle radius too small
  • 61214 Channel %1 block %2 no lead programmed
  • 61215 Channel %1 block %2 raw dimension incorrectly programmed
  • 61216 Channel %1 block %2 feed/tooth only possible with milling tools
  • 61217 Channel %1 block %2 cutting speed for tool radius 0 programmed
  • 61218 Channel %1 block %2 feed/tooth programmed, but number of teeth is zero
  • 61222 Channel %1 block %2 plane infeed greater than the tool diameter
  • 61223 Channel %1 block %2 approach path too short
  • 61224 Channel %1 block %2 retract path too short
  • 61225 Channel %1 block %2 swivel data block unknown
  • 61226 Channel %1 block %2 swivel head cannot be exchanged
  • 61230 Channel %1 block %2 tool probe diameter too small
  • 61231 Channel %1 block %2 ShopMill program %3 cannot be executed, as it has not been tested by ShopMill
  • 61232 Channel %1 block %2 loading of magazine tool not possible
  • 61233 Channel %1 block %2: Thread inclination incorrectly defined
  • 61234 Channel %1 block %2 ShopMill subroutine %4 cannot be executed, as it has not been tested by ShopMill
  • 61235 Channel %1 block %2: ShopTurn program %4 cannot be executed, as it has not been tested by ShopTurn.
  • 61236 Channel %1 block %2: ShopTurn subroutine %4 cannot be executed, as it has not been tested by ShopTurn.
  • 61237 Channel %1 block %2: Retraction direction unknown. Manually retract tool!
  • 61238 Channel %1 block %2: Machining direction unknown.
  • 61239 Channel %1 block %2: Tool change point lies in the retraction area!
  • 61240 Channel %1 block %2: Wrong feed type
  • 61241 Channel %1 block %2: No retraction plane defined for this machining direction.
  • 61242 Channel %1 block %2: Wrong machining direction
  • 61243 Channel %1 block %2: Correct tool change point, tool tip is in retraction area!
  • 61244 Channel %1 block %2: Thread lead change results in an undefined thread
  • 61246 Channel %1 block %2: Safety clearance too small
  • 61247 Channel %1 block %2: Blank radius too small
  • 61248 Channel %1 block %2: Infeed too small
  • 61249 Channel %1 block %2: Number of edges too small
  • 61250 Channel %1 block %2: Key width/Edge length too small
  • 61251 Channel %1 block %2: Key width/Edge length too large
  • 61252 Channel %1 block %2: Chamfer/Radius too large
  • 61253 Channel %1 block %2: No finishing allowance programmed
  • 61254 Channel %1 block %2: Error when traversing to fixed stop
  • 61255 Channel %1 block %2: Cut-off error: Tool breakage?
  • 61301 Channel %1 block %2 measuring probe does not switch
  • 61302 Channel %1 block %2 measuring probe collision
  • 61303 Channel %1 block %2 safe area exceeded
  • 61308 Channel %1 block %2 check measuring distance 2a
  • 61309 Channel %1 block %2 check measuring probe type
  • 61310 Channel %1 block %2 scale factor is active
  • 61311 Channel %1 block %2 no D number is active
  • 61316 Channel %1 block %2 center point and radius cannot be determined.
  • 61332 Channel %1 block %2 change tool tip position
  • 61338 Channel %1 block %2 positioning velocity is zero
  • 61601 Channel %1 block %2 finished-part diameter too small
  • 61602 Channel %1 block %2 tool width incorrectly defined
  • 61603 Channel %1 block %2 groove form incorrectly defined
  • 61604 Channel %1 block %2 active tool violates programmed contour
  • 61605 Channel %1 block %2 contour incorrectly programmed
  • 61606 Channel %1 block %2 contour processing error
  • 61607 Channel %1 block %2 starting point incorrectly programmed
  • 61608 Channel %1 block %2 wrong cutting edge position programmed
  • 61609 Channel %1 block %2 form incorrectly defined
  • 61610 Channel %1 block %2 no infeed depth programmed
  • 61611 Channel %1 block %2 no intersection point found
  • 61612 Channel %1 block %2 thread axis cutting not possible
  • 61613 Channel %1 block %2 undercut position incorrectly defined
  • 61800 Channel %1 block %2: External CNC system missing
  • 61801 Channel %1 block %2: Wrong G code selected
  • 61802 Channel %1 block %2: Wrong axis type
  • 61803 Channel %1 block %2 programmed axis not present
  • 61804 Channel %1 block %2: Progr. position exceeds reference point
  • 61805 Channel %1 block %2: The value is absolutely and incrementally programmed
  • 61806 Channel %1 block %2: Incorrect axis assignment
  • 61807 Channel %1 block %2 wrong spindle direction programmed (active)
  • 61808 Channel %1 block %2: The final drilling depth or individual drilling depth is missing
  • 61809 Channel %1 block %2: Impermissible drilling position
  • 61810 Channel %1 block %2: ISO-G code not possible
  • 61811 Channel %1 block %2: Impermissible ISO axis name
  • 61812 Channel %1 block %2: Value(s) in the external cycle call incorrectly defined
  • 61813 Channel %1 block %2: GUD value incorrectly defined
  • 61814 Channel %1 block %2: Polar coordinates not possible with cycle
  • 61815 Channel %1 block %2: G40 not active
  • 61816 Channel %1 block %2: axes are not at the reference point
  • 61817 Channel %1 block %2: The axis coordinates are within the protection zone
  • 61818 Channel %1 block %2: The axis area limit values are identical
  • 62000 Channel %1 block %2:
  • 62100 Channel %1 block %2 no drilling cycle active
  • 62101 Channel %1 block %2: Incorrect cutting direction – G3 is generated
  • 62103 Channel %1 block %2: The finishing allowance is not programmed
  • 62105 Channel %1 block %2 number of columns or lines is zero
  • 62180 Channel %1 block %2 no name assigned to swivel data block although machine data $MN_MM_NUM_TOOL_CARRIER > 1
  • 62181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)
  • 62182 Channel %1 block %2: Load swivel head
  • 62183 Channel %1 block %2 retraction mode GUD7 _TC_FR beyond value range 0…2
  • 62184 Channel %1 block %2 no solution possible with current input angle values
  • 62185 Channel %1 block %2 no end stop assigned to rotary axes
  • 62186 Channel %1 block %2 illegal rotary axis vectors
  • 62187 Channel %1 block %2 name of swivel data block unknown
  • 62200 Channel %1 block %2: Start spindle
  • 63000 Channel %1 block %2:
  • 65000 Channel %1 block %2:
  • 66000 Channel %1 block %2:
  • 67000 Channel %1 block %2:
  • 68000 Channel %1 block %2:
  • 70000 Compile cycle alarm
  • 75000 OEM alarm
  • 75005 Channel %1 block %2 CLC: General programming error
  • 75010 Channel %1 block %2 CLC_LIM value exceeds MD limit
  • 75015 Channel %1 block %2 CLC(0) with active TOC
  • 75016 Channel %1 block %2 CLC: orientation changed for TRAFOOF
  • 75020 Channel %1 CLC position offset at lower limit %2
  • 75021 Channel %1 CLC position offset at upper limit %2
  • 75025 Channel %1 CLC stopped because sensor head has been touched
  • 75050 Channel %1 wrong MD configuration, error code %2
  • 75051 Channel %1 CC_COPON CC_COPOFF error code %2
  • 75060 Channel %1 tolerance window exceeded axis %2
  • 75061 Channel %1 coupling active axis %2
  • 75062 Channel %1 axes not in standstill axis %2
  • 75070 Channel %1 wrong machine data for collision protection %2
  • 75071 Channel %1 collision monitoring axis %2
  • 75100 Too many analog axes configured
  • 75110 Axis %1 reached drift limit
  • 75200 Channel %1 wrong MD configuration, %2 incorrect
  • 75210 Channel %1 number of axes/axis assignment inconsistent
  • 75250 Channel %1 tool parameters incorrect
  • 75255 Channel %1 working area error 
  • 75260 Channel %1 block %2 tool parameters incorrect
  • 75265 Channel %1 block %2 working area error
  • 75270 Channel %1 tool parameters incorrect
  • 75275 Channel %1 block %2 working area error
  • 75451 Error with definition of setpoint switchover
  • 75452 Axis %1 setpoint switchover not possible in the current state
  • 75500 Channel %1 wrong configuration
  • 75600 Channel %1 retrace support: wrong MD configuration. Error code %2
  • 75601 Channel %1 block %2 invalid parameter in CC_PREPRE()
  • 75605 Channel %1 retrace support: internal error, error code %2
  • 75606 Channel %1 retraceable contour was shortened
  • 75607 Channel %1 resynchronisation not possible

Pages: 1 2 3

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

SINUMERIK

SINUMERIK 808D ADVANCED

Diagnostics Manual

Diagnostics Manual

06/2015

6FC5398-6DP10-0BA2

Preface

Fundamental safety

instructions

Introduction

Operating in the system data

management operating area

Operating in the alarm

operating area

SINUMERIK 808D

ADVANCED alarms

System responses

SINAMICS V70 faults and

alarms

Data backup

Updating software

Appendix A

1

2

3

4

5

6

7

8

9

A

Related Manuals for Siemens SINUMERIK 808D ADVANCED

Summary of Contents for Siemens SINUMERIK 808D ADVANCED

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

SINUMERIK

SINUMERIK 808D ADVANCED

Diagnostics Manual

Diagnostics Manual

06/2015

6FC5398-6DP10-0BA2

Preface

Fundamental safety

instructions

Introduction

Operating in the system data

management operating area

Operating in the alarm

operating area

SINUMERIK 808D

ADVANCED alarms

System responses

SINAMICS V70 faults and

alarms

Data backup

Updating software

Appendix A

1

2

3

4

5

6

7

8

9

A

Related Manuals for Siemens SINUMERIK 808D ADVANCED

Summary of Contents for Siemens SINUMERIK 808D ADVANCED

Понравилась статья? Поделить с друзьями:
  • Siemens sinamics s120 коды ошибок
  • Siemens ошибка 700017
  • Siemens sinamics power module 240 коды ошибок
  • Siemens ошибка 25201
  • Siemens sinamics g120 ошибка f8501