OPERATION
The control panel fault indicator lights will display the following codes when the machine detects a fault.
CODE
Light #1 blinks
Lights #1, #2 and #3
ripple
Lights #1 and #4 blink
Lights #3 and #4 blink
Lights #2 and #3 blink
Lights #1 and #3 blink
Light #2 blinks
Lights #1 and #2 blink
Light #3 blinks
Light #3 blinks when
pressing the solution flow,
brush pressure buttons
and FaST system switch
Lights #1, #2 and #3 blink
All battery lights blink
All battery lights ripple
34
Light #4
Light #1
Light #2
FAULT
Recovery tank is raised.
Battery charger connected.
Left Brush motor overload.
Right Brush motor overload.
Propel motor overload.
Exceeded maximum incline.
Scrub head movement is obstructed or
actuator motor malfunction.
Vacuum motor malfunction.
Propel throttle malfunction.
FaST pump overload or malfunction.
Supervisor controls activated
(lockout feature)
Wand Pump overload or malfunction.
Emergency—Stop button activated
Key turned on while bail was engaged.
Light #3
Battery Lights
SOLUTION
Lower recovery tank. Restart key to reset.
Disconnect battery charger. Restart key to
reset.
Inspect brush for entangled debris,
improper pad or contact service center.
Restart key to reset.
Inspect brush for entangled debris,
improper pad or contact service center.
Restart key to reset.
Avoid steep inclines or contact service
center. Restart key to reset.
Check scrub head for obstruction or con-
tact service center. Restart key to reset.
Contact service center.
Contact service center.
Reset the 10A circuit breaker or contact
service center. Restart key to reset.
Contact your Supervisor.
Reset the 10A circuit breaker button or
contact service center. Restart key to
reset.
Turn button clockwise to reset.
Release the control handle start bail.
Tennant T5 (06- -06)
ON- -BOARD BATTERY CHARGER ERROR CODES
DISPLAY CODE
bat
E01
E02
E03
SCt
Srt
T5 9002333 REV.02 (07-06)
T5 –Maintenance
(Page 3 of 15)
FAULT
Loose or damaged battery cable
Battery exceeded maximum voltage level.
Exceeded maximum battery voltage allowed.
Safety thermostat exceeded maximum internal
temperature.
Exceeded maximum time for charging phase
leaving the batteries undercharged due to a
sulfated or faulty battery.
Safety timer exceeded maximum charging
time. Interrupts charging cycle.
Possible internal short circuit.
SOLUTION
Check battery cable connections.
No action necessary.
No action necessary.
Check if the charger vents are obstructed.
Repeat the charging cycle and if the error
code E03 reappears check battery or
replace it.
Replace battery.
Contact Service Center.
M
9
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
T5
Scrubber-Dryer
English
EN
Operator Manual
R
For the latest Parts manual and other
language Operator manuals, visit:
9002347
www.tennantco.com/manuals
Rev. 07 (06-2016)
*000000*
www.tennantco.com
Related Manuals for Tennant T5
Summary of Contents for Tennant T5
- Page 1
Scrubber-Dryer English Operator Manual For the latest Parts manual and other language Operator manuals, visit: 9002347 www.tennantco.com/manuals Rev. 07 (06-2016) *000000* www.tennantco.com… - Page 2
It provides necessary operation and maintenance INTENDED USE instructions. Read this manual completely and The T5 walk behind scrubber is designed to scrub hard understand the machine before surfaces (concrete, asphalt, stone, synthetic, etc) in an operating or servicing it. -
Page 3: Table Of Contents
USING AN OFF- BOARD BATTERY CHARGER (OPTION) ……Tennant T5 (06- 16)
-
Page 4: Important Safety Instructions
Keep battery compartment open when With pads or accessories not supplied or charging. approved by Tennant. The use of other pads may impair safety. WARNING: Flammable materials can cause an explosion or fire. Do not use flammable materials In outdoors areas.
- Page 5
All repairs must be performed by trained personnel. Do not modify the machine from its original design. Use Tennant supplied or approved replacement parts. Wear personal protective equipment as needed and where recommended in this manual. For Safety: wear protective gloves. -
Page 6: Safety Labels
Keep sparks and open flame away when charging. Keep battery compartment open when charging. FOR SAFETY LABEL — Read manual before Located at bottom side of operating machine. recovery tank. Located on recovery tank cover. Tennant T5 (12- 13)
-
Page 7: Machine Components
11. Squeegee Assembly 25. Pad Driver Window 12. Solution Tank Clean-Out Port 26. Scrub Head Skirt 13. Recovery Tank Support Stand 27. Parking Brake 14. Control Board 28. Cylindrical Brush Scrub Head 15. Bucket Fill Port/Clean- out Port Tennant T5 (09- 08)
-
Page 8: Control Panel Components
6. Solution flow decrease button (- ) 13. ec- H2O system indicator light (ec- H2O model) 7. Fault indicator — Contact Service 14. Main power on/off key switch 8. Supervisor Control indicator — Lockout feature 15. Hour meter Tennant T5 (09- 08)
-
Page 9: Machine Installation
2. Lift the recovery tank and remove the right side battery compartment panel (Figure 1). 13mm on- board battery charger, make sure that the wrench required. charger is properly set for your battery type before charging (See ON- BOARD CHARGER SETTINGS). Tennant T5 (12- 13)
-
Page 10: How The Machine Works
Stripping Pad (Brown) — Used for stripping of floor finish to prepare the floor for recoating. Heavy Duty Stripping Pad (Black) — Used for aggressive stripping of heavy finishes/sealers, or very heavy duty scrubbing. Tennant T5 (06- 15)
-
Page 11: Machine Setup
2. Attach the pad to the pad driver before installing FIG. 5 the driver. Secure pad with centerlock (Figure 9). 4. Connect the vacuum hose to the squeegee assembly. Loop the hose as shown using the hose clip provided (Figure 6). FIG. 9 FIG. 6 Tennant T5 (12- 13)
- Page 12
(Figure 12). 4. Check the brushes to ensure they are properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). FIG. 12 6. Check the scrub head to ensure that it is properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). Tennant T5 (06- 16) -
Page 13: Ec-H2O Nanoclean Water Conditioning Cartridge (Ec-H2O Nanoclean Model)
(Figure 16). 3. When the supply hose is not in use, connect the storage plug to prevent the FaST system from drying out and clogging up the hose. (Figure 19). FIG. 16 FIG. 19 Tennant T5 (06- 15)
-
Page 14: Filling Solution Tank
ATTENTION: ec-H2O NanoClean Models- During first time use and after replacing the water conditioning cartridge, the ec-H2O system will automatically override the selected solution flow rate for up to 75 minutes. Tennant T5 (06- 15)
- Page 15
FaST scrubbing or for ec-H2O (Figure 25). To reverse the machine, simply push scrubbing on ec-H2O models manufactured before the control handle bail forward. Raise squeegee ec-H2O NanoClean models. when reversing machine. Tennant T5 (06- 15) -
Page 16: Emergency Shut- Off Button
3. Do not operate machine in areas where the ambient temperature is above 43 C (110 F). Do not operate scrubbing functions in areas where the ambient temperature is below freezing 0 C (32 F) Tennant T5 (12- 13)
-
Page 17: Battery Charge Level Indicator
FIG. 31 FIG. 32 ec- H2O SYSTEM INDICATOR LIGHT CODE CONDITION Solid green Normal operation Blinking red Flush ec- H2O module Solid red Contact Service Center Tennant T5 (06- 15)
-
Page 18: Hour Meter
2. Connect the solution hose to the coupler at the lower right side of machine (Figure 34). FIG. 37 FIG. 34 Tennant T5 (09- 08)
-
Page 19: Draining And Cleaning Tanks
FIG. 41 4. Clean the float shut-off screen and debris tray located in the recovery tank (Figure 42). FIG. 42 Tennant T5 (12- 13)
-
Page 20: Draining Solution Tank
FIG. 44 — FOR WET (Lead acid) BATTERIES 3. Clean the solution tank filter (Figure 45). OUTPUT VOLTAGE — 24 VOLTS OUTPUT CURRENT — 20 AMPS AUTOMATIC SHUTOFF CIRCUIT FOR DEEP CYCLE BATTERY CHARGING FIG. 45 Tennant T5 (06- 16)
-
Page 21: On- Board Battery Charger Settings
Lead Acid (Wet) The charger cord must be unplugged when resetting. Gel (Generic) Charger Version 3.5 Exide GEL BATTERY LEAD ACID BATTERY Generic GEL BATTERY Charger Version 3.4 or earlier GEL BATTERY LEAD ACID BATTERY FIG. 47 Tennant T5 (12- 13)
-
Page 22: Using The On- Board Battery Charger
4. Prop up the recovery tank for ventilation (Figure 48). FIG. 48 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 49). NOTE: The machine will not operate when charging. FIG. 49 Tennant T5 (NIL)
-
Page 23: On- Board Battery Charger Error Codes
E03 reappears check battery or re- sulfated or faulty battery. place it. Safety timer exceeded maximum charging Replace battery. time. Interrupts charging cycle. Possible internal short circuit. Contact Service Center. Tennant T5 (03- 08)
-
Page 24: Using An Off- Board Battery Charger (Option)
FOR SAFETY: Do not disconnect the charger’s DC cord from the machine’s receptacle when the charger is operating. Arcing may result. If the charger must be interrupted during charging, disconnect the AC power supply cord first. Tennant T5 (12- 13)
-
Page 25: Cylindrical Brush Model
6. Raise the scrub head and pull the machine away. 7. Observe the brush pattern on floor. If the brush pattern is uneven or tapered, adjustment is required. 8. Reconnect drive motor wire. Tennant T5 (06- 06)
- Page 26
4. To lower the brush end, turn the shaft clockwise for the front brush and counter- clockwise for the rear brush. Retighten hex screw (Figure 61). FIG. 61 5. Recheck brush pattern. NOTE: Replace brushes when worn to 15mm. Tennant T5 (06- 06) -
Page 27: Maintenance Chart
Check and clean 750 Hours Vacuum fan motor Replace carbon brushes Disk brush motors Replace carbon brushes Propelling motor Replace carbon brushes 1000 Hours Cylindrical brush motors Replace carbon brushes FaST water and air filters Replace Tennant T5 (12- 13)
-
Page 28: Machine Maintenance
Rinse and clean out the recovery tank (Figure 63). FIG. 67 FIG. 63 7. Rotate pad or replace when worn (Figure 68). 3. Remove the recovery tank float shut- off screen and clean (Figure 64). Disk Model FIG. 68 FIG. 64 Tennant T5 (12- 13)
- Page 29
71). Replace when worn to a length of 15mm. 13. Check the condition of the squeegee blade wiping edge (Figure 74). Rotate blade if worn (See SQUEEGEE BLADES). 15mm Cylindrical Brush Model FIG. 71 FIG. 74 Tennant T5 (06- 16) -
Page 30: Monthly Maintenance
Cylindrical Brush Model FIG. 79 2. Inspect and clean the recovery tank cover seal (Figure 80). Replace if damaged. FIG. 77 17. Recharge the batteries (Figure 78). See CHARGING BATTERIES. FIG. 80 Tennant T5 (06- 16)
-
Page 31: Battery Maintenance
Add distilled water if low. DO NOT OVERFILL. The electrolyte will expand and may overflow when charging. After charging, distilled water can be added up to about 3 mm (0.12 in) below the sight tubes. FIG. 83 Tennant T5 (06- 16)
-
Page 32: Squeegee Blades
(Figure 85). FIG. 87 MOTOR MAINTENANCE Replace motor carbon brushes as indicated. Contact trained personnel for carbon brush replacement. Carbon Brush Replacement Hours Drive Transaxle Motor Vacuum Motor Disk Brush Motors Cylindrical Brush Motors 1000 FIG. 85 Tennant T5 (12- 13)
-
Page 33: Fast System Maintenance
(Figure 92). 3. Replace the water and air filter. An 8mm hex wrench is required to install the new water filter (Figure 90). Water Filter (50 Mesh/Brown) Gray Collar FIG. 92 Air Filter (50 Mesh/Brown) FIG. 90 Tennant T5 (06- 15)
-
Page 34: Ec- H2O Module Flush Procedure
7 minute cycle in order to reset the system indicator light and alarm. FIG. 94 Repeat flush procedure if the ec- H2O module does not reset. If module fails to reset, contact an Authorized Service Center. Tennant T5 (06- 15)
-
Page 35: Jacking Up Machine
5. Open the recovery tank cover to promote air circulation. ATTENTION: Do not expose machine to rain, store indoors. 6. If storing machine in freezing temperatures, follow the FREEZE PROTECTION instructions below. Tennant T5 (06- 16)
-
Page 36: Freeze Protection
If the antifreeze is not properly flushed from the ec- H2O system, the ec- H2O module may detect an error and not function (ec- H2O switch indicator light will turn red). If this occurs, reset key and repeat the flush procedure as described below. Tennant T5 (06- 15)
-
Page 37: Troubleshooting
Faulty control board Contact Service Center Wheels raised off floor Contact Service Center Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Tennant T5 (06- 06)
- Page 38
Replace battery Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger Solution flow and brush pressure Supervisor controls are activated Contact your Supervisor buttons and FaST system switch (lockout feature) are locked Tennant T5 (06- 06) - Page 39
Defective module Contact Service Center solid red ec- H2O system indicator light Defective light or module Contact Service Center does not turn on No water flow Clogged module Contact Service Center Defective solution pump Replace solution pump Tennant T5 (06- 15) -
Page 40: Control Panel Fault Indicator Codes
Restart key to reset. All battery lights blink Emergency- Stop button activated Turn button clockwise to reset. All battery lights ripple Key turned on while bail was engaged. Release the control handle start bail. Tennant T5 (06- 06)
-
Page 41: General Machine Dimensions/Capacities/Performance
SOUND POWER LEVEL 84 dBa 83 dBa +UNCERTAINTY K VIBRATION AT HAND- ARM* <2.5 m/s <2.5 m/s GRADE LEVEL, MAX. Scrubbing 5%, Transporting 8%, Ramp Loading (tanks empty) 19.5% * Values per EN 60335- 2- 72 Tennant T5 (12- 13)
-
Page 42: Machine Dimensions
800 mm Disk Disk Disk Cylindrical Cylindrical 1.346 mm 1.400 mm 1.463 mm 1.387 mm 1.387 mm 645 mm 737 mm 838 mm 711 mm 864 mm 908 mm 1.051 mm 1.185 mm 1.051 mm 1.185 mm Tennant T5 (09- 08)
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
T5
Scrubber-Dryer
English
EN
Operator Manual
R
For the latest Parts manual and other
language Operator manuals, visit:
9002347
www.tennantco.com/manuals
Rev. 07 (06-2016)
*000000*
www.tennantco.com
Related Manuals for Tennant T5
Summary of Contents for Tennant T5
- Page 1
Scrubber-Dryer English Operator Manual For the latest Parts manual and other language Operator manuals, visit: 9002347 www.tennantco.com/manuals Rev. 07 (06-2016) *000000* www.tennantco.com… - Page 2
It provides necessary operation and maintenance INTENDED USE instructions. Read this manual completely and The T5 walk behind scrubber is designed to scrub hard understand the machine before surfaces (concrete, asphalt, stone, synthetic, etc) in an operating or servicing it. -
Page 3: Table Of Contents
USING AN OFF- BOARD BATTERY CHARGER (OPTION) ……Tennant T5 (06- 16)
-
Page 4: Important Safety Instructions
Keep battery compartment open when With pads or accessories not supplied or charging. approved by Tennant. The use of other pads may impair safety. WARNING: Flammable materials can cause an explosion or fire. Do not use flammable materials In outdoors areas.
- Page 5
All repairs must be performed by trained personnel. Do not modify the machine from its original design. Use Tennant supplied or approved replacement parts. Wear personal protective equipment as needed and where recommended in this manual. For Safety: wear protective gloves. -
Page 6: Safety Labels
Keep sparks and open flame away when charging. Keep battery compartment open when charging. FOR SAFETY LABEL — Read manual before Located at bottom side of operating machine. recovery tank. Located on recovery tank cover. Tennant T5 (12- 13)
-
Page 7: Machine Components
11. Squeegee Assembly 25. Pad Driver Window 12. Solution Tank Clean-Out Port 26. Scrub Head Skirt 13. Recovery Tank Support Stand 27. Parking Brake 14. Control Board 28. Cylindrical Brush Scrub Head 15. Bucket Fill Port/Clean- out Port Tennant T5 (09- 08)
-
Page 8: Control Panel Components
6. Solution flow decrease button (- ) 13. ec- H2O system indicator light (ec- H2O model) 7. Fault indicator — Contact Service 14. Main power on/off key switch 8. Supervisor Control indicator — Lockout feature 15. Hour meter Tennant T5 (09- 08)
-
Page 9: Machine Installation
2. Lift the recovery tank and remove the right side battery compartment panel (Figure 1). 13mm on- board battery charger, make sure that the wrench required. charger is properly set for your battery type before charging (See ON- BOARD CHARGER SETTINGS). Tennant T5 (12- 13)
-
Page 10: How The Machine Works
Stripping Pad (Brown) — Used for stripping of floor finish to prepare the floor for recoating. Heavy Duty Stripping Pad (Black) — Used for aggressive stripping of heavy finishes/sealers, or very heavy duty scrubbing. Tennant T5 (06- 15)
-
Page 11: Machine Setup
2. Attach the pad to the pad driver before installing FIG. 5 the driver. Secure pad with centerlock (Figure 9). 4. Connect the vacuum hose to the squeegee assembly. Loop the hose as shown using the hose clip provided (Figure 6). FIG. 9 FIG. 6 Tennant T5 (12- 13)
- Page 12
(Figure 12). 4. Check the brushes to ensure they are properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). FIG. 12 6. Check the scrub head to ensure that it is properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). Tennant T5 (06- 16) -
Page 13: Ec-H2O Nanoclean Water Conditioning Cartridge (Ec-H2O Nanoclean Model)
(Figure 16). 3. When the supply hose is not in use, connect the storage plug to prevent the FaST system from drying out and clogging up the hose. (Figure 19). FIG. 16 FIG. 19 Tennant T5 (06- 15)
-
Page 14: Filling Solution Tank
ATTENTION: ec-H2O NanoClean Models- During first time use and after replacing the water conditioning cartridge, the ec-H2O system will automatically override the selected solution flow rate for up to 75 minutes. Tennant T5 (06- 15)
- Page 15
FaST scrubbing or for ec-H2O (Figure 25). To reverse the machine, simply push scrubbing on ec-H2O models manufactured before the control handle bail forward. Raise squeegee ec-H2O NanoClean models. when reversing machine. Tennant T5 (06- 15) -
Page 16: Emergency Shut- Off Button
3. Do not operate machine in areas where the ambient temperature is above 43 C (110 F). Do not operate scrubbing functions in areas where the ambient temperature is below freezing 0 C (32 F) Tennant T5 (12- 13)
-
Page 17: Battery Charge Level Indicator
FIG. 31 FIG. 32 ec- H2O SYSTEM INDICATOR LIGHT CODE CONDITION Solid green Normal operation Blinking red Flush ec- H2O module Solid red Contact Service Center Tennant T5 (06- 15)
-
Page 18: Hour Meter
2. Connect the solution hose to the coupler at the lower right side of machine (Figure 34). FIG. 37 FIG. 34 Tennant T5 (09- 08)
-
Page 19: Draining And Cleaning Tanks
FIG. 41 4. Clean the float shut-off screen and debris tray located in the recovery tank (Figure 42). FIG. 42 Tennant T5 (12- 13)
-
Page 20: Draining Solution Tank
FIG. 44 — FOR WET (Lead acid) BATTERIES 3. Clean the solution tank filter (Figure 45). OUTPUT VOLTAGE — 24 VOLTS OUTPUT CURRENT — 20 AMPS AUTOMATIC SHUTOFF CIRCUIT FOR DEEP CYCLE BATTERY CHARGING FIG. 45 Tennant T5 (06- 16)
-
Page 21: On- Board Battery Charger Settings
Lead Acid (Wet) The charger cord must be unplugged when resetting. Gel (Generic) Charger Version 3.5 Exide GEL BATTERY LEAD ACID BATTERY Generic GEL BATTERY Charger Version 3.4 or earlier GEL BATTERY LEAD ACID BATTERY FIG. 47 Tennant T5 (12- 13)
-
Page 22: Using The On- Board Battery Charger
4. Prop up the recovery tank for ventilation (Figure 48). FIG. 48 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 49). NOTE: The machine will not operate when charging. FIG. 49 Tennant T5 (NIL)
-
Page 23: On- Board Battery Charger Error Codes
E03 reappears check battery or re- sulfated or faulty battery. place it. Safety timer exceeded maximum charging Replace battery. time. Interrupts charging cycle. Possible internal short circuit. Contact Service Center. Tennant T5 (03- 08)
-
Page 24: Using An Off- Board Battery Charger (Option)
FOR SAFETY: Do not disconnect the charger’s DC cord from the machine’s receptacle when the charger is operating. Arcing may result. If the charger must be interrupted during charging, disconnect the AC power supply cord first. Tennant T5 (12- 13)
-
Page 25: Cylindrical Brush Model
6. Raise the scrub head and pull the machine away. 7. Observe the brush pattern on floor. If the brush pattern is uneven or tapered, adjustment is required. 8. Reconnect drive motor wire. Tennant T5 (06- 06)
- Page 26
4. To lower the brush end, turn the shaft clockwise for the front brush and counter- clockwise for the rear brush. Retighten hex screw (Figure 61). FIG. 61 5. Recheck brush pattern. NOTE: Replace brushes when worn to 15mm. Tennant T5 (06- 06) -
Page 27: Maintenance Chart
Check and clean 750 Hours Vacuum fan motor Replace carbon brushes Disk brush motors Replace carbon brushes Propelling motor Replace carbon brushes 1000 Hours Cylindrical brush motors Replace carbon brushes FaST water and air filters Replace Tennant T5 (12- 13)
-
Page 28: Machine Maintenance
Rinse and clean out the recovery tank (Figure 63). FIG. 67 FIG. 63 7. Rotate pad or replace when worn (Figure 68). 3. Remove the recovery tank float shut- off screen and clean (Figure 64). Disk Model FIG. 68 FIG. 64 Tennant T5 (12- 13)
- Page 29
71). Replace when worn to a length of 15mm. 13. Check the condition of the squeegee blade wiping edge (Figure 74). Rotate blade if worn (See SQUEEGEE BLADES). 15mm Cylindrical Brush Model FIG. 71 FIG. 74 Tennant T5 (06- 16) -
Page 30: Monthly Maintenance
Cylindrical Brush Model FIG. 79 2. Inspect and clean the recovery tank cover seal (Figure 80). Replace if damaged. FIG. 77 17. Recharge the batteries (Figure 78). See CHARGING BATTERIES. FIG. 80 Tennant T5 (06- 16)
-
Page 31: Battery Maintenance
Add distilled water if low. DO NOT OVERFILL. The electrolyte will expand and may overflow when charging. After charging, distilled water can be added up to about 3 mm (0.12 in) below the sight tubes. FIG. 83 Tennant T5 (06- 16)
-
Page 32: Squeegee Blades
(Figure 85). FIG. 87 MOTOR MAINTENANCE Replace motor carbon brushes as indicated. Contact trained personnel for carbon brush replacement. Carbon Brush Replacement Hours Drive Transaxle Motor Vacuum Motor Disk Brush Motors Cylindrical Brush Motors 1000 FIG. 85 Tennant T5 (12- 13)
-
Page 33: Fast System Maintenance
(Figure 92). 3. Replace the water and air filter. An 8mm hex wrench is required to install the new water filter (Figure 90). Water Filter (50 Mesh/Brown) Gray Collar FIG. 92 Air Filter (50 Mesh/Brown) FIG. 90 Tennant T5 (06- 15)
-
Page 34: Ec- H2O Module Flush Procedure
7 minute cycle in order to reset the system indicator light and alarm. FIG. 94 Repeat flush procedure if the ec- H2O module does not reset. If module fails to reset, contact an Authorized Service Center. Tennant T5 (06- 15)
-
Page 35: Jacking Up Machine
5. Open the recovery tank cover to promote air circulation. ATTENTION: Do not expose machine to rain, store indoors. 6. If storing machine in freezing temperatures, follow the FREEZE PROTECTION instructions below. Tennant T5 (06- 16)
-
Page 36: Freeze Protection
If the antifreeze is not properly flushed from the ec- H2O system, the ec- H2O module may detect an error and not function (ec- H2O switch indicator light will turn red). If this occurs, reset key and repeat the flush procedure as described below. Tennant T5 (06- 15)
-
Page 37: Troubleshooting
Faulty control board Contact Service Center Wheels raised off floor Contact Service Center Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Tennant T5 (06- 06)
- Page 38
Replace battery Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger Solution flow and brush pressure Supervisor controls are activated Contact your Supervisor buttons and FaST system switch (lockout feature) are locked Tennant T5 (06- 06) - Page 39
Defective module Contact Service Center solid red ec- H2O system indicator light Defective light or module Contact Service Center does not turn on No water flow Clogged module Contact Service Center Defective solution pump Replace solution pump Tennant T5 (06- 15) -
Page 40: Control Panel Fault Indicator Codes
Restart key to reset. All battery lights blink Emergency- Stop button activated Turn button clockwise to reset. All battery lights ripple Key turned on while bail was engaged. Release the control handle start bail. Tennant T5 (06- 06)
-
Page 41: General Machine Dimensions/Capacities/Performance
SOUND POWER LEVEL 84 dBa 83 dBa +UNCERTAINTY K VIBRATION AT HAND- ARM* <2.5 m/s <2.5 m/s GRADE LEVEL, MAX. Scrubbing 5%, Transporting 8%, Ramp Loading (tanks empty) 19.5% * Values per EN 60335- 2- 72 Tennant T5 (12- 13)
-
Page 42: Machine Dimensions
800 mm Disk Disk Disk Cylindrical Cylindrical 1.346 mm 1.400 mm 1.463 mm 1.387 mm 1.387 mm 645 mm 737 mm 838 mm 711 mm 864 mm 908 mm 1.051 mm 1.185 mm 1.051 mm 1.185 mm Tennant T5 (09- 08)
Достигните высочайшего уровня чистоты, гигиены и безопасности с поломоечной машиной Tennant T5
- Берегите ресурсы! Чистите без химикатов с новой технологией ec-H2O™ — электрически активированная вода превращает воду в мощное чистящее средство
- Берегите ресурсы! Чистите, используя на 90% меньше чистящего средства, и уменьшите размеры упаковки для химикатов на 80% с технологией FaST®
- Берегите ресурсы! Уменьшите потребление воды на 90% и сократите неэффективное использование на 70% с технологией FaST®
- Поломоечная машина tennant T5 уменьшает количество бактерий и налета благодаря легко очищаемым и легко доступным гигиеничным бакам
- Низкий уровень шума в 67 дБ позволяет чистить в самых чувствительных к шуму местах
- Улучшенная безопасность — поломоечная машина Tennant T5 полностью удаляет моющее средство, даже при повороте на 180 градусов, благодаря уникально спроектированному скребку
Ключевые характеристики производительности и надежности машины Tennant T5:
- В машине Tennant Т5 установлены гигиеничные баки, уменьшающие количество плесени, бактерий и других загрязняющих веществ
- Работающая от аккумуляторов поломоечная машина Tennant T5 практически не издает шума
- Параболическая система скребка обладает оптимальным углом атаки, что позволяет полностью удалять остатки моющего средства
- Технология FaST® использует до 70% меньше моющего средства во время чистки
- Технология ec-H2O™ обеспечивает великолепный результат чистки без использования химикатов
Выберите лучшую технологию чистки для вашей среды
- Новая технология ec-H2O™ — электрически активированная вода сокращает негативное влияние на окружающую среду: изготовление упаковки, транспортировку, использование и переработку химикатов
- Технология FaST® — технология чистки пеной. Используя инновационную систему чистки пеной, поломоечные машины с FaST увеличивают производительность до 30%, уменьшают потребление воды до 70% и исключают необходимость контакта оператора с химикатами.
Tennant T5 – среднеразмерная производительная машина, для работы которой используется технология FaST®, снижающая объем химических моющих средств на 80%. Кроме того, значительно снижено потребление воды, улучшены показатели производительности, машина оборудована удобными гигиеническими баками.
Техника может использоваться для жилых помещений, офисов, торговых и развлекательных центров, салонов. В качестве источника питания установлена батарея на 24 В, общая мощность техники – 1200 Вт.
Особенности и преимущества модели Т5
Моющая машина T5 среднеразмерного класса отличается такими преимуществами:
- производитель – до 1000-2500 кв.м/час;
- ширина дорожки очистки – 60-70см;
- скорость уборки (в зависимости от выбранного режима) – 2925-3600 кв.м/час;
- низкий уровень шума – 67 ДБа;
- простая замена щеток;
- наличие технологии FaST® для экономного расхода воды и моющих средств;
- автономность, благодаря установленному аккумулятору;
- возможность использования модели с технологий ec-H2O.
Модель является самой мощной в среднеразмерном классе, она востребована для уборки офисов, развлекательных центров, жилых помещений, салонов и магазинов. Удобные щетки обеспечивают уборку мусора в труднодоступных места, машина работает от батареи, что обеспечивает ее автономность и мобильность.
Для заказа модели Т500 звоните нам по телефону: +7 (812) 425-62-66, также Вы можете оставить онлайн-заявку на сайте с указанием своих контактных данных.
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
T5
Scrubber- -Dryer
Operator Manual
The Safe Scrubbing Alternativer
R
Hygenic
Fully Cleanable Tanks
QA Controlst Supervisor Settings
North America / International
9002326
Rev. 06 (11- -2008)
*9002326*
www.tennantco.com
Related Manuals for Tennant T5
Summary of Contents for Tennant T5
- Page 1
Scrubber- -Dryer Operator Manual The Safe Scrubbing Alternativer Hygenic Fully Cleanable Tanks QA Controlst Supervisor Settings North America / International 9002326 Rev. 06 (11- -2008) *9002326* www.tennantco.com… - Page 2
Phone: (800) 553- -8033 or (763) 513- -2850 www.tennantco.com FaSK—PAK and 1—STEP are US registered and unregistered trademarks of Tennant Company. Specifications and parts are subject to change without notice. Copyright E 2006, 2007, 2008 TENNANT COMPANY, Printed in U.S.A. All rights reserved. Tennant T5 (09- -08) -
Page 3: Table Of Contents
….MACHINE DIMENSIONS ….Tennant T5 (11- -08)
-
Page 4: Safety Precautions
Do not modify the machine from its original order to avoid a hazard. design. WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine. Tennant T5 (11- -08)
-
Page 5: Safety Labels
Before Working On Machine. BATTERY CHARGE LABEL — — Located on bottom side of recovery tank. WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. Tennant T5 (06- -06)
-
Page 6: Machine Components
11. Squeegee Assembly 25. Pad Driver Window 12. Solution Tank Clean-Out Port 26. Scrub Head Skirt 13. Recovery Tank Support Stand 27. Parking Brake (option) 14. Control Board 28. Cylindrical Brush Scrub Head 15. Bucket Fill Port/Clean—out Port Tennant T5 (09- -08)
-
Page 7: Control Panel Components
6. Solution flow decrease button (—) 13. ec- -H2O system indicator light (ec- -H2O model) 7. Fault indicator — Contact Service 14. Main power on/off key switch 8. Supervisor control indicator — Lockout feature 15. Hour meter Tennant T5 (09- -08)
-
Page 8: Machine Installation
(Figure 1). 13mm wrench required. IMPORTANT: If your machine is equipped with the on- -board battery charger, make sure that the charger is properly set for your battery type before charging (See ON- -BOARD CHARGER SETTINGS). Tennant T5 (06- -06)
-
Page 9: How The Machine Works
Nylon fiber impregnated with abrasive grit to remove stains and soilage. Strong action on any surface. FIG. 5 Performs well on buildup, grease, or tire marks. Polishing Pad (White) — — Used to maintain highly polished or burnished floors. Tennant T5 (09- -08)
-
Page 10: Installing Brushes
(Figure 8). FIG. 10 4. To remove the pad driver, raise the scrub head and push the pad release plunger downward (Figure 11). 2 mm 1/16” Lock Nut FIG. 8 FIG. 11 Tennant T5 (09- -08)
-
Page 11: Installing Fast—Pak
(See ADJUSTING SCRUB HEAD FIG. 15 BRUSHES). 3. When the supply hose is not in use, connect the storage plug to prevent the FaST system from drying out and clogging up the hose (Figure 16). FIG. 16 Tennant T5 (06- -06)
-
Page 12: Filling Solution Tank
( I ) position (Figure 19). ec- H2O Model: Press the ec- -H2O system switch to the on ( I ) position (Figure 19). NOTE: The ec- -H2O system indicator light will not turn on until the machine starts scrubbing. Tennant T5 (03- -08)
- Page 13
(Figure 22). To reverse the machine, simply push the control handle bail forward. Raise squeegee when reversing machine. FIG. 24 9. To stop scrubbing, release the control handle bail, press the 1- -STEP scrub button and raise the squeegee. Tennant T5 (09- -08) -
Page 14: Emergency Stopping
PROCEDURE) (Figure 26). NOTE: When the alarm sounds and the light blinks red, FIG. 27 the machine will bypass the ec- -H2O system. To continue scrubbing, turn the ec- -H2O switch off and change over to conventional scrubbing. Tennant T5 (09- -08)
-
Page 15: Hour Meter
1. Turn the key and wand switch to the on ( I ) 2. Connect the solution hose to the coupler at the position (Figure 32). The FaST/ec- -H2O system lower right side of machine (Figure 29). switch is disabled when operating the wand. FIG. 29 FIG. 32 Tennant T5 (09- -08)
-
Page 16: Draining And Cleaning Tanks
WARNING: Fire or Explosion Hazard. Do Not Pick Up Flammable Materials Or Reactive Metals. FIG. 36 4. Clean the float shut-off screen and debris tray located in the recovery tank (Figure 37). FIG. 37 Tennant T5 (09- -08)
-
Page 17: Draining Solution Tank
The charger will display a sequence of codes. One of the codes will either read “GEL” or “Acd” (Figure 41). GEL = Set for sealed/maintenance free batteries Acd = Set for wet/lead acid batteries FIG. 40 FIG. 41 Tennant T5 (06- -06)
-
Page 18: Using The On- -Board Battery Charger
If the charger detects a problem, the charger will display an error code (See ON—BOARD BATTERY CHARGER ERROR CODES). FIG. 43 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 44). Tennant T5 (09- -06)
-
Page 19: On—Board Battery Charger Error Codes
E03 reappears check battery or re- sulfated or faulty battery. place it. Safety timer exceeded maximum charging Replace battery. time. Interrupts charging cycle. Possible internal short circuit. Contact Service Center. Tennant T5 (06- -07)
-
Page 20: On—Board Charger Fuse Replacement
6. Connect the charger’s DC cord into the machine’s battery receptacle (Figure 50). FIG. 47 3. The fuse holder is located at the bottom of the charger. Use a screwdriver to access the fuse (Figure 48). FIG. 50 Tennant T5 (01- -07)
-
Page 21: Adjusting Scrub Head Brushes
(Figure 54). FIG. 51 4. If scrub head is not level, loosen the lock nut and turn the scrub head leveling screw to level. Tighten down the lock nut once head is level (Figure 52). FIG. 54 Tennant T5 (01- -07)
- Page 22
Retighten hex screw (Figure 59). FIG. 56 3. Recheck brush pattern. FIG. 59 NOTE: Replace brushes when worn to 5/8” (15mm). 5. Recheck brush pattern. NOTE: Replace brushes when worn to 5/8” (15mm). Tennant T5 (01- -07) -
Page 23: Machine Maintenance
Clean the solution tank filter (Figure 65). FIG. 61 FIG. 65 3. Remove the recovery tank float shut—off screen and clean (Figure 62). 7. Rotate pad or replace when worn (Figure 66). Disk Model FIG. 62 FIG. 66 Tennant T5 (01- -07)
- Page 24
13. Clean the machine with an all purpose cleaner and plates and drive hubs (Figure 69). damp cloth (Figure 72). FOR SAFETY: When cleaning machine, do not power spray or hose off machine. Electrical malfunction may occur. Cylindrical Brush Model FIG. 69 FIG. 72 Tennant T5 (01- -07) -
Page 25: Monthly Maintenance
3. Lubricate all pivot points and rollers with a water the machine was used for a total of 30 minutes or resistant grease. more. 4. Lubricate the casters with a water resistant grease (Figure 78). FIG. 75 FIG. 78 Tennant T5 (06- -07)
-
Page 26: Battery Maintenance
2. Clean the batteries to prevent battery corrosion. Use a scrub brush with a mixture of baking soda and water (Figure 80). FOR SAFETY: When cleaning batteries, wear protective gloves and eye protection. Avoid contact with battery acid. FIG. 82 Tennant T5 (01- -07)
-
Page 27: Motor Maintenance
(Figure 87). Vacuum Motor Water Filter Disk Brush Motors (50 Mesh/Brown) Cylindrical Brush Motors 1000 WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. Air Filter (50 Mesh/Brown) FIG. 87 Tennant T5 (03- -08)
-
Page 28: Ec—H2O Module Flush Procedure
FOR SAFETY: When servicing machine, jack machine up at designated locations only. Use jack FIG. 88 or hoist that will support machine weight. 4. Turn the key to the on ( I ) position. FIG. 90 Tennant T5 (11- -08)
-
Page 29: Transporting Machine
2. Fill the solution tank with cool water until full (See FILLING SOLUTION TANK). 4. Open the recovery tank cover to promote air circulation. ATTENTION: Do not expose machine to rain, store indoors. 5. If storing machine in freezing temperatures, follow the FREEZE PROTECTION instructions below. Tennant T5 (09- -08)
- Page 30
FIG. 97 detergent from the hose (Figure 95). Reconnect the hose after draining. To access the injector 10. To drain the antifreeze from the FaST supply hose, assembly remove the front cover. repeat steps 1 and 2. Tennant T5 (09- -08) -
Page 31: Recommended Stock Items
Contact Service Center Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Vacuum motor will not Squeegee is raised off floor Lower squeegee operate Tennant T5 (11- -08)
- Page 32
Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger Solution flow and brush Supervisor controls are activated (lock- Contact your Supervisor pressure buttons and out feature) FaST system switch are locked Tennant T5 (06- -06) - Page 33
H2O Model: Defective light or module Contact Service Center ec- -H2O system indicator light does not turn on ec- H2O Model: Clogged module Contact Service Center No water flow Defective solution pump Replace solution pump Tennant T5 (09- -08) -
Page 34: Control Panel Fault Indicator Codes
Restart key to reset. All battery lights blink Emergency—Stop button activated Turn button clockwise to reset. All battery lights ripple Key turned on while bail was engaged. Release the control handle start bail. Tennant T5 (06- -06)
-
Page 35: Machine Specifications
GRADE LEVEL, MAX. Scrubbing 5% (3°), Transporting 8% (5°) * Run times are based on Continuous Scrubbing Run Times. ** Sound pressure (ISO 11201) as recommended by the American Association of Cleaning Equipment Manufacturers (AACEM) and OSHA. Tennant T5 (06- -07)
- Page 36
0.83 L/min 1.14 L/min 1.67 L/min (optional) (optional) (optional) (optional) 0.30 gpm / 0.44 gpm / 1.67 L/min 1.14 L/min (optional) (optional) * If the optional solution flow rates are required, contact an Authorized Service Center. Tennant T5 (09- -08) -
Page 37: Machine Dimensions
33 in / 838 mm 28 in / 711 mm 34 in / 864 mm 35.7 in / 908 mm 41.3 in / 1,051 mm 46.6 in / 1,185 mm 41.3 in / 1,051 mm 46.6 in / 1,185 mm Tennant T5 (06- -07)
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
T5
Scrubber- -Dryer
Operator Manual
The Safe Scrubbing Alternativer
R
Hygenic
Fully Cleanable Tanks
QA Controlst Supervisor Settings
North America / International
9002326
Rev. 06 (11- -2008)
*9002326*
www.tennantco.com
Related Manuals for Tennant T5
Summary of Contents for Tennant T5
- Page 1
Scrubber- -Dryer Operator Manual The Safe Scrubbing Alternativer Hygenic Fully Cleanable Tanks QA Controlst Supervisor Settings North America / International 9002326 Rev. 06 (11- -2008) *9002326* www.tennantco.com… - Page 2
Phone: (800) 553- -8033 or (763) 513- -2850 www.tennantco.com FaSK—PAK and 1—STEP are US registered and unregistered trademarks of Tennant Company. Specifications and parts are subject to change without notice. Copyright E 2006, 2007, 2008 TENNANT COMPANY, Printed in U.S.A. All rights reserved. Tennant T5 (09- -08) -
Page 3: Table Of Contents
….MACHINE DIMENSIONS ….Tennant T5 (11- -08)
-
Page 4: Safety Precautions
Do not modify the machine from its original order to avoid a hazard. design. WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine. Tennant T5 (11- -08)
-
Page 5: Safety Labels
Before Working On Machine. BATTERY CHARGE LABEL — — Located on bottom side of recovery tank. WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. Tennant T5 (06- -06)
-
Page 6: Machine Components
11. Squeegee Assembly 25. Pad Driver Window 12. Solution Tank Clean-Out Port 26. Scrub Head Skirt 13. Recovery Tank Support Stand 27. Parking Brake (option) 14. Control Board 28. Cylindrical Brush Scrub Head 15. Bucket Fill Port/Clean—out Port Tennant T5 (09- -08)
-
Page 7: Control Panel Components
6. Solution flow decrease button (—) 13. ec- -H2O system indicator light (ec- -H2O model) 7. Fault indicator — Contact Service 14. Main power on/off key switch 8. Supervisor control indicator — Lockout feature 15. Hour meter Tennant T5 (09- -08)
-
Page 8: Machine Installation
(Figure 1). 13mm wrench required. IMPORTANT: If your machine is equipped with the on- -board battery charger, make sure that the charger is properly set for your battery type before charging (See ON- -BOARD CHARGER SETTINGS). Tennant T5 (06- -06)
-
Page 9: How The Machine Works
Nylon fiber impregnated with abrasive grit to remove stains and soilage. Strong action on any surface. FIG. 5 Performs well on buildup, grease, or tire marks. Polishing Pad (White) — — Used to maintain highly polished or burnished floors. Tennant T5 (09- -08)
-
Page 10: Installing Brushes
(Figure 8). FIG. 10 4. To remove the pad driver, raise the scrub head and push the pad release plunger downward (Figure 11). 2 mm 1/16” Lock Nut FIG. 8 FIG. 11 Tennant T5 (09- -08)
-
Page 11: Installing Fast—Pak
(See ADJUSTING SCRUB HEAD FIG. 15 BRUSHES). 3. When the supply hose is not in use, connect the storage plug to prevent the FaST system from drying out and clogging up the hose (Figure 16). FIG. 16 Tennant T5 (06- -06)
-
Page 12: Filling Solution Tank
( I ) position (Figure 19). ec- H2O Model: Press the ec- -H2O system switch to the on ( I ) position (Figure 19). NOTE: The ec- -H2O system indicator light will not turn on until the machine starts scrubbing. Tennant T5 (03- -08)
- Page 13
(Figure 22). To reverse the machine, simply push the control handle bail forward. Raise squeegee when reversing machine. FIG. 24 9. To stop scrubbing, release the control handle bail, press the 1- -STEP scrub button and raise the squeegee. Tennant T5 (09- -08) -
Page 14: Emergency Stopping
PROCEDURE) (Figure 26). NOTE: When the alarm sounds and the light blinks red, FIG. 27 the machine will bypass the ec- -H2O system. To continue scrubbing, turn the ec- -H2O switch off and change over to conventional scrubbing. Tennant T5 (09- -08)
-
Page 15: Hour Meter
1. Turn the key and wand switch to the on ( I ) 2. Connect the solution hose to the coupler at the position (Figure 32). The FaST/ec- -H2O system lower right side of machine (Figure 29). switch is disabled when operating the wand. FIG. 29 FIG. 32 Tennant T5 (09- -08)
-
Page 16: Draining And Cleaning Tanks
WARNING: Fire or Explosion Hazard. Do Not Pick Up Flammable Materials Or Reactive Metals. FIG. 36 4. Clean the float shut-off screen and debris tray located in the recovery tank (Figure 37). FIG. 37 Tennant T5 (09- -08)
-
Page 17: Draining Solution Tank
The charger will display a sequence of codes. One of the codes will either read “GEL” or “Acd” (Figure 41). GEL = Set for sealed/maintenance free batteries Acd = Set for wet/lead acid batteries FIG. 40 FIG. 41 Tennant T5 (06- -06)
-
Page 18: Using The On- -Board Battery Charger
If the charger detects a problem, the charger will display an error code (See ON—BOARD BATTERY CHARGER ERROR CODES). FIG. 43 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 44). Tennant T5 (09- -06)
-
Page 19: On—Board Battery Charger Error Codes
E03 reappears check battery or re- sulfated or faulty battery. place it. Safety timer exceeded maximum charging Replace battery. time. Interrupts charging cycle. Possible internal short circuit. Contact Service Center. Tennant T5 (06- -07)
-
Page 20: On—Board Charger Fuse Replacement
6. Connect the charger’s DC cord into the machine’s battery receptacle (Figure 50). FIG. 47 3. The fuse holder is located at the bottom of the charger. Use a screwdriver to access the fuse (Figure 48). FIG. 50 Tennant T5 (01- -07)
-
Page 21: Adjusting Scrub Head Brushes
(Figure 54). FIG. 51 4. If scrub head is not level, loosen the lock nut and turn the scrub head leveling screw to level. Tighten down the lock nut once head is level (Figure 52). FIG. 54 Tennant T5 (01- -07)
- Page 22
Retighten hex screw (Figure 59). FIG. 56 3. Recheck brush pattern. FIG. 59 NOTE: Replace brushes when worn to 5/8” (15mm). 5. Recheck brush pattern. NOTE: Replace brushes when worn to 5/8” (15mm). Tennant T5 (01- -07) -
Page 23: Machine Maintenance
Clean the solution tank filter (Figure 65). FIG. 61 FIG. 65 3. Remove the recovery tank float shut—off screen and clean (Figure 62). 7. Rotate pad or replace when worn (Figure 66). Disk Model FIG. 62 FIG. 66 Tennant T5 (01- -07)
- Page 24
13. Clean the machine with an all purpose cleaner and plates and drive hubs (Figure 69). damp cloth (Figure 72). FOR SAFETY: When cleaning machine, do not power spray or hose off machine. Electrical malfunction may occur. Cylindrical Brush Model FIG. 69 FIG. 72 Tennant T5 (01- -07) -
Page 25: Monthly Maintenance
3. Lubricate all pivot points and rollers with a water the machine was used for a total of 30 minutes or resistant grease. more. 4. Lubricate the casters with a water resistant grease (Figure 78). FIG. 75 FIG. 78 Tennant T5 (06- -07)
-
Page 26: Battery Maintenance
2. Clean the batteries to prevent battery corrosion. Use a scrub brush with a mixture of baking soda and water (Figure 80). FOR SAFETY: When cleaning batteries, wear protective gloves and eye protection. Avoid contact with battery acid. FIG. 82 Tennant T5 (01- -07)
-
Page 27: Motor Maintenance
(Figure 87). Vacuum Motor Water Filter Disk Brush Motors (50 Mesh/Brown) Cylindrical Brush Motors 1000 WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. Air Filter (50 Mesh/Brown) FIG. 87 Tennant T5 (03- -08)
-
Page 28: Ec—H2O Module Flush Procedure
FOR SAFETY: When servicing machine, jack machine up at designated locations only. Use jack FIG. 88 or hoist that will support machine weight. 4. Turn the key to the on ( I ) position. FIG. 90 Tennant T5 (11- -08)
-
Page 29: Transporting Machine
2. Fill the solution tank with cool water until full (See FILLING SOLUTION TANK). 4. Open the recovery tank cover to promote air circulation. ATTENTION: Do not expose machine to rain, store indoors. 5. If storing machine in freezing temperatures, follow the FREEZE PROTECTION instructions below. Tennant T5 (09- -08)
- Page 30
FIG. 97 detergent from the hose (Figure 95). Reconnect the hose after draining. To access the injector 10. To drain the antifreeze from the FaST supply hose, assembly remove the front cover. repeat steps 1 and 2. Tennant T5 (09- -08) -
Page 31: Recommended Stock Items
Contact Service Center Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Vacuum motor will not Squeegee is raised off floor Lower squeegee operate Tennant T5 (11- -08)
- Page 32
Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger Solution flow and brush Supervisor controls are activated (lock- Contact your Supervisor pressure buttons and out feature) FaST system switch are locked Tennant T5 (06- -06) - Page 33
H2O Model: Defective light or module Contact Service Center ec- -H2O system indicator light does not turn on ec- H2O Model: Clogged module Contact Service Center No water flow Defective solution pump Replace solution pump Tennant T5 (09- -08) -
Page 34: Control Panel Fault Indicator Codes
Restart key to reset. All battery lights blink Emergency—Stop button activated Turn button clockwise to reset. All battery lights ripple Key turned on while bail was engaged. Release the control handle start bail. Tennant T5 (06- -06)
-
Page 35: Machine Specifications
GRADE LEVEL, MAX. Scrubbing 5% (3°), Transporting 8% (5°) * Run times are based on Continuous Scrubbing Run Times. ** Sound pressure (ISO 11201) as recommended by the American Association of Cleaning Equipment Manufacturers (AACEM) and OSHA. Tennant T5 (06- -07)
- Page 36
0.83 L/min 1.14 L/min 1.67 L/min (optional) (optional) (optional) (optional) 0.30 gpm / 0.44 gpm / 1.67 L/min 1.14 L/min (optional) (optional) * If the optional solution flow rates are required, contact an Authorized Service Center. Tennant T5 (09- -08) -
Page 37: Machine Dimensions
33 in / 838 mm 28 in / 711 mm 34 in / 864 mm 35.7 in / 908 mm 41.3 in / 1,051 mm 46.6 in / 1,185 mm 41.3 in / 1,051 mm 46.6 in / 1,185 mm Tennant T5 (06- -07)
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
T5
Scrubber-Dryer
English
EN
Operator Manual
R
For the latest Parts manual and other
language Operator manuals, visit:
9002347
www.tennantco.com/manuals
Rev. 07 (06-2016)
*000000*
www.tennantco.com
Related Manuals for Tennant T5
Summary of Contents for Tennant T5
-
Page 1
Scrubber-Dryer English Operator Manual For the latest Parts manual and other language Operator manuals, visit: 9002347 www.tennantco.com/manuals Rev. 07 (06-2016) *000000* www.tennantco.com… -
Page 2
It provides necessary operation and maintenance INTENDED USE instructions. Read this manual completely and The T5 walk behind scrubber is designed to scrub hard understand the machine before surfaces (concrete, asphalt, stone, synthetic, etc) in an operating or servicing it. -
Page 3: Table Of Contents
USING AN OFF- BOARD BATTERY CHARGER (OPTION) ……Tennant T5 (06- 16)
-
Page 4: Important Safety Instructions
Keep battery compartment open when With pads or accessories not supplied or charging. approved by Tennant. The use of other pads may impair safety. WARNING: Flammable materials can cause an explosion or fire. Do not use flammable materials In outdoors areas.
-
Page 5
All repairs must be performed by trained personnel. Do not modify the machine from its original design. Use Tennant supplied or approved replacement parts. Wear personal protective equipment as needed and where recommended in this manual. For Safety: wear protective gloves. -
Page 6: Safety Labels
Keep sparks and open flame away when charging. Keep battery compartment open when charging. FOR SAFETY LABEL — Read manual before Located at bottom side of operating machine. recovery tank. Located on recovery tank cover. Tennant T5 (12- 13)
-
Page 7: Machine Components
11. Squeegee Assembly 25. Pad Driver Window 12. Solution Tank Clean-Out Port 26. Scrub Head Skirt 13. Recovery Tank Support Stand 27. Parking Brake 14. Control Board 28. Cylindrical Brush Scrub Head 15. Bucket Fill Port/Clean- out Port Tennant T5 (09- 08)
-
Page 8: Control Panel Components
6. Solution flow decrease button (- ) 13. ec- H2O system indicator light (ec- H2O model) 7. Fault indicator — Contact Service 14. Main power on/off key switch 8. Supervisor Control indicator — Lockout feature 15. Hour meter Tennant T5 (09- 08)
-
Page 9: Machine Installation
2. Lift the recovery tank and remove the right side battery compartment panel (Figure 1). 13mm on- board battery charger, make sure that the wrench required. charger is properly set for your battery type before charging (See ON- BOARD CHARGER SETTINGS). Tennant T5 (12- 13)
-
Page 10: How The Machine Works
Stripping Pad (Brown) — Used for stripping of floor finish to prepare the floor for recoating. Heavy Duty Stripping Pad (Black) — Used for aggressive stripping of heavy finishes/sealers, or very heavy duty scrubbing. Tennant T5 (06- 15)
-
Page 11: Machine Setup
2. Attach the pad to the pad driver before installing FIG. 5 the driver. Secure pad with centerlock (Figure 9). 4. Connect the vacuum hose to the squeegee assembly. Loop the hose as shown using the hose clip provided (Figure 6). FIG. 9 FIG. 6 Tennant T5 (12- 13)
-
Page 12
(Figure 12). 4. Check the brushes to ensure they are properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). FIG. 12 6. Check the scrub head to ensure that it is properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). Tennant T5 (06- 16) -
Page 13: Ec-H2O Nanoclean Water Conditioning Cartridge (Ec-H2O Nanoclean Model)
(Figure 16). 3. When the supply hose is not in use, connect the storage plug to prevent the FaST system from drying out and clogging up the hose. (Figure 19). FIG. 16 FIG. 19 Tennant T5 (06- 15)
-
Page 14: Filling Solution Tank
ATTENTION: ec-H2O NanoClean Models- During first time use and after replacing the water conditioning cartridge, the ec-H2O system will automatically override the selected solution flow rate for up to 75 minutes. Tennant T5 (06- 15)
-
Page 15
FaST scrubbing or for ec-H2O (Figure 25). To reverse the machine, simply push scrubbing on ec-H2O models manufactured before the control handle bail forward. Raise squeegee ec-H2O NanoClean models. when reversing machine. Tennant T5 (06- 15) -
Page 16: Emergency Shut- Off Button
3. Do not operate machine in areas where the ambient temperature is above 43 C (110 F). Do not operate scrubbing functions in areas where the ambient temperature is below freezing 0 C (32 F) Tennant T5 (12- 13)
-
Page 17: Battery Charge Level Indicator
FIG. 31 FIG. 32 ec- H2O SYSTEM INDICATOR LIGHT CODE CONDITION Solid green Normal operation Blinking red Flush ec- H2O module Solid red Contact Service Center Tennant T5 (06- 15)
-
Page 18: Hour Meter
2. Connect the solution hose to the coupler at the lower right side of machine (Figure 34). FIG. 37 FIG. 34 Tennant T5 (09- 08)
-
Page 19: Draining And Cleaning Tanks
FIG. 41 4. Clean the float shut-off screen and debris tray located in the recovery tank (Figure 42). FIG. 42 Tennant T5 (12- 13)
-
Page 20: Draining Solution Tank
FIG. 44 — FOR WET (Lead acid) BATTERIES 3. Clean the solution tank filter (Figure 45). OUTPUT VOLTAGE — 24 VOLTS OUTPUT CURRENT — 20 AMPS AUTOMATIC SHUTOFF CIRCUIT FOR DEEP CYCLE BATTERY CHARGING FIG. 45 Tennant T5 (06- 16)
-
Page 21: On- Board Battery Charger Settings
Lead Acid (Wet) The charger cord must be unplugged when resetting. Gel (Generic) Charger Version 3.5 Exide GEL BATTERY LEAD ACID BATTERY Generic GEL BATTERY Charger Version 3.4 or earlier GEL BATTERY LEAD ACID BATTERY FIG. 47 Tennant T5 (12- 13)
-
Page 22: Using The On- Board Battery Charger
4. Prop up the recovery tank for ventilation (Figure 48). FIG. 48 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 49). NOTE: The machine will not operate when charging. FIG. 49 Tennant T5 (NIL)
-
Page 23: On- Board Battery Charger Error Codes
E03 reappears check battery or re- sulfated or faulty battery. place it. Safety timer exceeded maximum charging Replace battery. time. Interrupts charging cycle. Possible internal short circuit. Contact Service Center. Tennant T5 (03- 08)
-
Page 24: Using An Off- Board Battery Charger (Option)
FOR SAFETY: Do not disconnect the charger’s DC cord from the machine’s receptacle when the charger is operating. Arcing may result. If the charger must be interrupted during charging, disconnect the AC power supply cord first. Tennant T5 (12- 13)
-
Page 25: Cylindrical Brush Model
6. Raise the scrub head and pull the machine away. 7. Observe the brush pattern on floor. If the brush pattern is uneven or tapered, adjustment is required. 8. Reconnect drive motor wire. Tennant T5 (06- 06)
-
Page 26
4. To lower the brush end, turn the shaft clockwise for the front brush and counter- clockwise for the rear brush. Retighten hex screw (Figure 61). FIG. 61 5. Recheck brush pattern. NOTE: Replace brushes when worn to 15mm. Tennant T5 (06- 06) -
Page 27: Maintenance Chart
Check and clean 750 Hours Vacuum fan motor Replace carbon brushes Disk brush motors Replace carbon brushes Propelling motor Replace carbon brushes 1000 Hours Cylindrical brush motors Replace carbon brushes FaST water and air filters Replace Tennant T5 (12- 13)
-
Page 28: Machine Maintenance
Rinse and clean out the recovery tank (Figure 63). FIG. 67 FIG. 63 7. Rotate pad or replace when worn (Figure 68). 3. Remove the recovery tank float shut- off screen and clean (Figure 64). Disk Model FIG. 68 FIG. 64 Tennant T5 (12- 13)
-
Page 29
71). Replace when worn to a length of 15mm. 13. Check the condition of the squeegee blade wiping edge (Figure 74). Rotate blade if worn (See SQUEEGEE BLADES). 15mm Cylindrical Brush Model FIG. 71 FIG. 74 Tennant T5 (06- 16) -
Page 30: Monthly Maintenance
Cylindrical Brush Model FIG. 79 2. Inspect and clean the recovery tank cover seal (Figure 80). Replace if damaged. FIG. 77 17. Recharge the batteries (Figure 78). See CHARGING BATTERIES. FIG. 80 Tennant T5 (06- 16)
-
Page 31: Battery Maintenance
Add distilled water if low. DO NOT OVERFILL. The electrolyte will expand and may overflow when charging. After charging, distilled water can be added up to about 3 mm (0.12 in) below the sight tubes. FIG. 83 Tennant T5 (06- 16)
-
Page 32: Squeegee Blades
(Figure 85). FIG. 87 MOTOR MAINTENANCE Replace motor carbon brushes as indicated. Contact trained personnel for carbon brush replacement. Carbon Brush Replacement Hours Drive Transaxle Motor Vacuum Motor Disk Brush Motors Cylindrical Brush Motors 1000 FIG. 85 Tennant T5 (12- 13)
-
Page 33: Fast System Maintenance
(Figure 92). 3. Replace the water and air filter. An 8mm hex wrench is required to install the new water filter (Figure 90). Water Filter (50 Mesh/Brown) Gray Collar FIG. 92 Air Filter (50 Mesh/Brown) FIG. 90 Tennant T5 (06- 15)
-
Page 34: Ec- H2O Module Flush Procedure
7 minute cycle in order to reset the system indicator light and alarm. FIG. 94 Repeat flush procedure if the ec- H2O module does not reset. If module fails to reset, contact an Authorized Service Center. Tennant T5 (06- 15)
-
Page 35: Jacking Up Machine
5. Open the recovery tank cover to promote air circulation. ATTENTION: Do not expose machine to rain, store indoors. 6. If storing machine in freezing temperatures, follow the FREEZE PROTECTION instructions below. Tennant T5 (06- 16)
-
Page 36: Freeze Protection
If the antifreeze is not properly flushed from the ec- H2O system, the ec- H2O module may detect an error and not function (ec- H2O switch indicator light will turn red). If this occurs, reset key and repeat the flush procedure as described below. Tennant T5 (06- 15)
-
Page 37: Troubleshooting
Faulty control board Contact Service Center Wheels raised off floor Contact Service Center Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Tennant T5 (06- 06)
-
Page 38
Replace battery Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger Solution flow and brush pressure Supervisor controls are activated Contact your Supervisor buttons and FaST system switch (lockout feature) are locked Tennant T5 (06- 06) -
Page 39
Defective module Contact Service Center solid red ec- H2O system indicator light Defective light or module Contact Service Center does not turn on No water flow Clogged module Contact Service Center Defective solution pump Replace solution pump Tennant T5 (06- 15) -
Page 40: Control Panel Fault Indicator Codes
Restart key to reset. All battery lights blink Emergency- Stop button activated Turn button clockwise to reset. All battery lights ripple Key turned on while bail was engaged. Release the control handle start bail. Tennant T5 (06- 06)
-
Page 41: General Machine Dimensions/Capacities/Performance
SOUND POWER LEVEL 84 dBa 83 dBa +UNCERTAINTY K VIBRATION AT HAND- ARM* <2.5 m/s <2.5 m/s GRADE LEVEL, MAX. Scrubbing 5%, Transporting 8%, Ramp Loading (tanks empty) 19.5% * Values per EN 60335- 2- 72 Tennant T5 (12- 13)
-
Page 42: Machine Dimensions
800 mm Disk Disk Disk Cylindrical Cylindrical 1.346 mm 1.400 mm 1.463 mm 1.387 mm 1.387 mm 645 mm 737 mm 838 mm 711 mm 864 mm 908 mm 1.051 mm 1.185 mm 1.051 mm 1.185 mm Tennant T5 (09- 08)
Specifications:1175/1175937-t5.pdf file (15 May 2023) |
Accompanying Data:
Tennant T5 Battery Charger, Floor Machine PDF Service Information Manual (Updated: Monday 15th of May 2023 09:43:30 PM)
Rating: 4.1 (rated by 15 users)
Compatible devices: 5700XP, 5680, 2100, 515SS, 9000136, 800, 5400, S30.
Recommended Documentation:
Text of Service Information Manual
(Ocr-Read Version Summary of Contents, UPD: 15 May 2023)
-
36, Commonly Used Electrical Symbols & Terms + — Battery Fuse Normally Closed Push-Button Switch Normally Open Switch CR1 Relay Coil (Part 1 of Relay) Circuit Breaker Motor Wires Connected Together Normally Open Push-Button Switch Wiring Color Codes (Unless otherwise marked) 0 1 2 3 4 5 6 7 8 9 Tan Pink Brown Orange Yellow Green Blue Purple Gray White Right Most Digit of Wire Num…
-
4, BEFORE CONDUCTING TESTS: z Read and Follow ALL Safety Warnings and Precautions in Operator’s Manual z Always use an ESD (Electrostatic Discharge) strap when working near the Control Board z Be cautious when working near Control Board – Battery voltage is always present, even with Key OFF z Always Disconnect Batteries when removing or replacing components DURING TESTS: z Call Tech…
-
63, Rev 00 Indicates Maximum Throttle Indicates Throttle is in Forward Position Indicates Throttle is in Reverse Position Indicates Throttle is in Neutral Position Indicates Throttle position between Minimum and Maximum Indicates Minimum Throttle Fault LED’s 1, 2, and 3 Indicate the sensed level of the Speed Limit Potentiometer. No Fault LED’s ON = 30% of Maximum Propel Volt…
-
50, D1 EMERGENCY STOP SWITCH (OPTION) MAIN CONTACTOR CR1 15 5 5 5 56 17 SW2 5 4 BRAKE RELAY CR2 JUMPER (STANDARD) 66 6 5 v 1 RED CB1 5A 4 OFF-AISLE WAND PUMP MOTOR PIN J8-2 D2 1 RED 13 BLK POS CONTROL BOARD T5 – Hour Meter & Off-Aisle Wand Water Pump STANDOFF 2 + — 6 VDC + — 6 VDC + — 6 VDC + — 6 VDC CR1 NEG 2 3 26 34 4 PIN J6-24 PIN J6-18 1 RED 1 RED 13 BLK POST J11 POST J7 F1 100A …
-
64, (+) Solution Button 1. Power up holding the SOLUTION (+) key. Hold until one of the battery gauge LED’s flashes. 2. Push the SOLUTION (-) key to select battery type. Matching this selection to the batteries in your machine is crucial for longest battery life. First battery gauge LED (red) flashing == USA levels (default) Second battery gauge LED (yellow) flashing == EU levels …
-
45, D2 1 RED 13 BLK POS T5 – Propel System Neutral (no travel) STANDOFF 2 + — 6 VDC + — 6 VDC + — 6 VDC + — 6 VDC CR1 STANDOFF1 13 BLK NEG KEY SWITCH 2 3 26 34 4 PIN J6-24 PIN J6-18 1 RED 13 BLK POST J11 POST J7 SPEED LIMITER F1 100A + TO CB2 1 RED 1 RED 1 RED SW3 SW1 CHARGER INTERLOCK CONDITIONS: Key ON, propel NOT engaged, all other machine functions OFF ! Be cautious when working …
-
56, Tennant T5 Rev 00 One Step Button Indicates Month (One’s) Indicates the Month (Ten’s) Indicates the Day (Ten’s) Indicates the Year (One’s) Indicates the Day (One’s) Indicates the Year (Ten’s) Holding the One Step button on Power-up puts you into the software revision display mode. The number of blinks by the Down Pressure and Water level LED’s represents the software revision…
-
54, Tennant T5 T5 – Diagnostic & Fault Alarms High Current Faults Diagnostic LED Codes Fault Description Indicator Function — more than 24A for 10 minutes — more than 35A for 1 minute — more than 45A for 30 seconds — more than 60A for 5 seconds Disk Heads — more than 30A for 1 minute — more than 35A for 2 seconds Cylindrical Heads — more than 30A for 1 minute — more than 35A…
-
46, D1 EMERGENCY STOP SWITCH (OPTION) MAIN CONTACTOR CR1 15 5 5 5 56 17 SW2 5 4 BRAKE RELAY CR2 JUMPER (STANDARD) 66 6 5 v 1 RED CB1 5A 4 RIGHT BRUSH MOTOR 9 10 M1 PIN J8-2 10 10 D2 1 RED 13 BLK POS CONTROL BOARD T5 – Scrub Brushes STANDOFF 2 + — 6 VDC + — 6 VDC + — 6 VDC + — 6 VDC CR1 NEG 2 3 26 3 PIN J6-24 PIN J6-18 1 RED 1 RED 13 BLK POST J11 POST J7 F1 100A …
-
7, T5 Component Locator (Page 3 of 4) CYLINDRICAL SCRUB BRUSH MOTORS DISK SCRUB BRUSH MOTORS SCRUB HEAD ACTUATOR M5 SCRUB HEAD ACTUATOR M5 ACTUATOR MID-STROKE SWITCH SW5 ACTUATOR RETRACT SWITCH SW9 ACTUATOR EXTEND LIMIT SWITCH SW10 MOTOR M1 MOTOR M1 MOTOR M2 MOTOR M2 T5 9002333 REV.02 (07-06) 3 I
…
Tennant T5 Recommended Instructions:
Flybar 190, PVB98DTBB, iMcV-MediaLinX Series, IPX-2000
-
Advance acoustic
Adfinity 17ST
AdfinityTM 17ST / 20ST / X20R20D / X20D / X20C / X24DSERVICE MANUAL Advance models: 908 7161 020 908 7162 020 9087290020 908 7163 020 908 7164 020 908 7165 020 908 7166 0209096982000(5)2012-03 …
Adfinity 17ST 92
-
Triple S
17 XL
XL FLOOR MACHINESMODELS:17 XL, 17 XL CS & 20 XL17 DS XL & 20 DS XL1500 XL & 2000 XL OPERATING & MAINTENANCE INTRODUCTION INSTRUCTIONSREAD THIS BOOKThis operator’s book has important information for the use and safe operation of this machine. Read this book care …
17 XL 20
-
Mitchell
GS-13
GS-13 ROTARY SCRUBBER OPERATIONS MANUAL AND TROUBLESHOOTING GUIDE Thank you for purchasing Mitchell Professional Floor Cleaning Equipment. Please be sure to read the manual before operation. …
GS-13 9
-
Taski
swingo 1250B
swingo 750B/1250B PowerV008 / 12088-69 0702I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 I15 I14 I13 tr sl pt no it hr fr fi es en de dada…2de…12en…22es…32fi…..42fr…..52hr….62it…..71no…81pt….91sl ….101tr…..111*12088-69* …
swingo 1250B 12
-
General
FCS16
SERVICE MANUAL Service, Repair & Replacement Parts Information RIP-R-STRIPPER Floor Covering Stripper Model: FCS16 Form: PGSM4240301EU, Version 1.1, Original Instructions • Do not discard this manual. • Keep manual readily available for reference during operation or when servicing product. • Before operation, read and comprehend operator m …
FCS16 17
-
Fimap
IMx
© Copyright A+D Supplies 2017 A+D Supplies, Marsh House, Brunel Road, Newton Abbot, Devon, TQ12 4PB www.adswsupplies.com GUIDE INCLUDES Setting up for use Using the machine Cleaning after use Care & maintenance Instruction Manual for Fimap iMx …
IMx 10
-
IPC
CT105
MANUALE ISTRUZIONI PER L’USO / OPERATOR’S MANUAL / MANUEL D’INSTRUCTIONS / BEDIENUNGSANLEITUNG / MANUAL DE INSTRUCCIONES / BRUKERHÅNDBOK / GEBRUIKERSHANDLEIDING / MANUAL DE UTILIZAÇÃO /INSTRUKTIONSBOK / МАШИНА ДЛЯ МОЙКИ И СУШКИ ПОЛОВ / KULLANIM KILAVUZU /Consultare attentamente questo manuale prima di procedere a qualsiasi intervent …
CT105 266
-
Lievers
HAL200B
GEBRUIKERSHANDLEIDING / USER MANUAL / BEDIENUNGSANLEITUNG HAL200B/E/ER LIEVERS HOLLAND Groot Mijdrechtstraat 68 – 3641 RW Postbus 103 — 3640 AC Mijdrecht (NL) Tel.: 0031 – (0)297-231900 / Fax: 0031 – (0)297-231909 E-mail: [email protected] / Internet: www.lieversholland.nl …
HAL200B 59
-
Columbus
AKS 80
AKS 80│BM 108 Original-Bedienungsanleitung…………………….. 3 Kehrsaugmaschine und Zubehör Operating Manual…………………………………….. 16 Vacuum sweeper and accessories Mode d’Emploi………………………………………… 28 Balayeuse aspirante et accessories Manuale d’istruzione…………� …
AKS 80 80