Midea Group is a Chinese-based electrical appliance manufacturer that started the business back in 1968. Since its inception the electrical appliance manufacturer has made great strides in the electrical appliance world, offering innovative products that match the consumer’s needs. Working in more than 200 locations around the world, its 150,000 employees work to ensure exceptional results in every field.

In 2016 the company officially became a part of the Global Fortune 500 companies that produces light, floor care, water appliances, laundry, cooking appliances, refrigerator, VRF, kitchen appliances, and other heating and cooling solutions.

There is a time in your life when the most reliable appliance you have starts to show an error. While it might be a dark day, fortunately for you there is a simple solution for most error codes. To help you out we have accumulated a complete list of the Midea VRF error codes. Offering you a chance to find out exactly what is wrong with your appliance, so you can finally make a decision. Rather than fighting with the appliance, or spending endless money on the repair, we suggest you first find the problem and then look for a solution.

R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes:

V4 VRF: Advanced 3-pipe technology enables heat recovery between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption.

Error Codes Problem
E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby.
E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby.
E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby.
E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in standby.
E5 Power voltage error. Display on the faulty unit, all the ODUs are in standby.
E7 Discharge temp sensor error. Display on the faulty unit, all the ODUs are in standby.
E8 Outdoor unit address is wrong. Only display on the faulty slave unit, all the ODUs are in standby.
XE9 Driver model is mismatching. When X is 1, it means A system; 2 means B system.
H0 Communication error between main control chip and inverter driver chip. Display on the faulty unit, all the ODUs are in standby.
H1 Communication error between main control chip and communication chip. Display on the faulty unit, all the ODUs are in standby.
H2 Quantity of outdoor unit decreased. Only display on the master unit, all the ODUs are in standby.
H3 Quantity of outdoor unit increased. Only display on the master unit, all the ODUs are in standby.
H4 P6 protection appears three times in 60 minutes. Display on the faulty unit, all the ODUs are in standby. Cannot be recovered until re-power on.
H5 P2 protection appears three times in 60 minutes. Display on the faulty unit, all the ODUs are in standby. Cannot be recovered until re-power on.
H6 P4 protection appears three times in 100 minutes. Display on the faulty unit, all the ODUs are in standby. Cannot be recovered until re-power on.
H7 Quantity of indoor unit decreased. Only display on the master unit, all the ODUs are in standby.
H8 High pressure sensor error. The discharge pressure Pc≤0.3MPa(43.5PSI).
H9 P9 protection appears three times in 60 minutes. Display on the faulty unit, all the ODUs are in standby. Cannot be recovered until being power on again.
xHd Slave units malfunction. X stands for corresponding slave unit.
C7 PL protection appears three times in 100 minutes. Display on the faulty unit, all the ODUs are in standby. Cannot be recovered until re-power on.
P1 High pressure protection. Display on the faulty unit, all the ODUs are in standby.
P2 Low pressure protection. Display on the faulty unit, all the ODUs are in standby.
XP3 Over current protection of inverter compressor. Display on the faulty unit, all the ODUs are in standby.
P4 Compressor discharge temp protection. Display on the faulty unit, all the ODUs are in standby.
P5 Condenser high temperature protection. Display on the faulty unit, all the ODUs are in standby.
XP6 Inverter module protection. When X is 1, it means A inverter module; 2 means B inverter module.
P9 Fan module protection. Display on the faulty unit, all the ODUs are in standby.
PL Temperature protection of main inverter module.
L0 Inverter module error. Display after P6 displaying for one minute.
L1 DC generatrix low voltage error. Display after P6 displaying for one minute.
L2 DC generatrix high voltage error. Display after P6 displaying for one minute.
L3 Reserved.
L4 MCE error/ synchronization/ closed loop. Display after P6 displaying for one minute.
L5 Zero speed protection. Display after P6 displaying for one minute.
L6 Reserved.
L7 Phase sequence error. Display after P6 displaying for one minute.
L8 Frequency difference in one second more than 15Hz protection. Display after P6 displaying for one minute.
L9 Frequency difference between the real and the setting frequency more than 15Hz protection. Display after P6 displaying for one minute.

V6-i VRF 50/60Hz Error Codes:

V6 VRF: As the leading VRF product, V6 boasts substantial benefits such as the single capacity can be up to 32HP (34HP for India) which is leading in HVAC industry; EVI compressor significantly increases heating and cooling capacity under extreme conditions, EMS realizes that evaporating temperature (in cooling) and condensing temperature (in heating) are automatically adjusted according to both indoor and outdoor temperature to maximize the comfort and energy efficiency.

Midea V6 VRF Error Codes

Midea V6 VRF Error Codes
Error Codes Problem
E1 Phase sequence
E2 Communication error between indoor and outdoor units
E4 Outdoor heat exchanger temperature sensor (T3) error or outdoor ambient temperature sensor (T4) error
E5 Abnormal power supply voltage
E7 Compressor top or discharge pipe temperature sensor (T7C1/2) error
E8 Outdoor unit address error
xE9 EEPROM mismatch
xF1 DC bus voltage error
F3 Plate heat exchanger cooling refrigerant outlet temperature sensor (T6B) error
F5 Plate heat exchanger cooling refrigerant inlet temperature sensor (T6A) error
F6 Electronic expansion valve connection error
xH0 Communication error between main control chip and inverter driver chip
xH4 Inverter module protection
H5 P2 protection appears three times in 60 minutes
H6 P4 protection appears three times in 100 minutes
H7 Number of indoor units detected by outdoor unit not same as number set on main PCB
H8 High pressure sensor error
H9 P9 protection appears ten times in 120 minutes
C7 PL protection appears three times in 100 minutes
P1 Discharge pipe high pressure protection
P2 Suction pipe low pressure protection
xP3 Compressor current protection
P4 Discharge temperature protection
P5 Outdoor heat exchanger temperature protection
P9 Fan module protection
PL Inverter module temperature protection
PP Compressor discharge insufficient superheat protection
xL0 Inverter module protection
xL1 DC bus low voltage protection
xL2 DC bus high voltage protection
xL4 MCE error
xL5 Zero speed protection
xL7 Phase sequence error
xL8 Compressor frequency variation greater than 15Hz within one second protection
xL9 Actual compressor frequency differs from target frequency by more than 15Hz protection

R410A All DC Inverter Mini VRF Error Codes:

Midea VRF systems feature a compact footprint which requires less outdoor space, and with long piping length, the system allows maximum flexibility in installation. There are also a variety of indoor unit styles available depending on the preference of the homeowner or the installation requirements.

Mini VRF Error Codes

Mini VRF Error Codes
Error Codes Problem
HF Not matched with M_HOME indoor unit
E0 EEPROM malfunction
E9 EEPROM malfunction
E2 Communication malfunction between indoor/outdoor units
E3 Communication malfunction in outdoor PCB
H0 Communication malfunction in outdoor PCB
E4 T3&T4 temperature sensor malfunction
E5 Outdoor unit voltage protection
E6 DC fan error
E7 Discharge Sensor Malfunction
EA Discharge Sensor Malfunction
E8 There are two times E6 fault in 10 minutes (recovery after power off)
Eb There are two times E6 fault in 10 minutes (recovery after power off)
P0 Reserved
P1 High pressure protection
P2 Low pressure protection
P3 Compressor current protection
P4 Compressor discharge temperature protection
P5 Condenser high temperature protection
P6 IPM modules protection
P7 Evaporator high temperature protection
PE Evaporator high temperature protection
P8 Typhoon protection
L0 Module malfunction
L1 DC generatrix low voltage protection
L2 DC generatrix high voltage protection
L3 Reserved
L4 MCE malfunction/simultaneously/cycle loop
L5 Zero speed protection
L6 Reserved
L7 Wrong phase protection
L8 Speed difference>15Hz protection between the front and the back clock
L9 Speed difference>15Hz protection between the real and the setting speed

Midea VRF Service Manual PDF

Midea AC Error Codes

  • Author
  • Recent Posts

Danny Reese

Regarding error and fault codes, we believe sharing knowledge is the best way to help everyone. That is why we established ACErrorCode.com, to give you every bit of info you need as a customer. HVAC Expert Contact: dannyreese@acerrorcode.com

Danny Reese

*If you can’t find the code you’re looking for on our site, please let us know, and we’ll update our database as soon as possible.

Серия Midea LCAC DC Inverter

Внутренние кассетные четырёхпоточные модели:

Ошибка running lamp timer lamp defrosting alarm lamp Malfunction Комментарий masterxoloda.ru
E1 Led2 Quik Flash In-Outdoor unit communication cheking channel is abnormal Нет связи между внутренним и внешним блоком
E2 Led 1 Quik Flash Room temerature sensor cheking channel is abnormal Неисправен — закорочен или оборван датчик температуры воздуха
E3 Led 1 Quik Flash Pipe temerature T2 sensor cheking channel is abnormal Неисправен датчик температуры испарителя (разъём CN12 на плате)
E4 Led 1 Quik Flash Pipe temerature T2B temerature sensor cheking channel is abnormal Неисправен датчик температуры а выходе из испарителя (разъём CN7 на плате)
EE Led 4 Quik Flash Water-level alarm malfunction Ошибка переполнения дренажного поддона конденсатом
E0 Led 3 Quik Flash Collision model malfunction Несоответствие моделей кондиционера
E7 Led 1 Quik Flash EEPROM Неисправна ППЗУ, менять плату, либо микросхему с прошивкой
Ed Led 4 Quik Flash Outdoor malfunction Неисправен внешний блок, смотреть ошибки для него

Для напольно — потолочных внутренних блоков:

Ошибка running lamp timer lamp defrosting alarm lamp Malfunction Комментарий masterxoloda.ru
¤ In-Outdoor unit communication cheking channel is abnormal Нет связи между внутренним и внешним блоком
¤ Room temerature sensor cheking channel is abnormal Неисправен — закорочен или оборван датчик температуры воздуха
¤ Water-level alarm malfunction Ошибка переполнения дренажного поддона конденсатом
¤ Collision model malfunction Несоответствие моделей кондиционера
slow flash Outdoor malfunction Неисправен внешний блок, смотреть ошибки для него

Для канальных кондиционеров:

Ошибка operation timer DEF.FAN alarm Malfunction Комментарий masterxoloda.ru
E1 Flash. 5 Hz In-Outdoor unit communication cheking channel is abnormal Нет связи между внутренним и внешним блоком
E2 Flash. 5 Hz Room temerature sensor cheking channel is abnormal Неисправен — закорочен или оборван датчик температуры воздуха
E3 Flash. 5 Hz Pipe temerature T2 sensor cheking channel is abnormal Неисправен датчик температуры испарителя (разъём CN12 на плате)
E4 Flash. 5 Hz Pipe temerature T2B temerature sensor cheking channel is abnormal Неисправен датчик температуры а выходе из испарителя (разъём CN7 на плате)
EE Flash. 5 Hz Water-level alarm malfunction Ошибка переполнения дренажного поддона конденсатом
E0 Flash. 5 Hz Collision model malfunction Несоответствие моделей кондиционера
E7 Flash. 1 Hz EEPROM Неисправна ППЗУ, менять плату, либо микросхему с прошивкой
Ed Flash. 1 Hz Outdoor malfunction Неисправен внешний блок, смотреть ошибки для него
CP Flash. 1 Hz Be closed by the remote control function На пульте управления включена функция блокировки
Light Light Avoid cold fan and defrost Работает функция разморозки во избежание задевания вентилятором наледи

Ошибки внешних блоков:

Код ошибки Неисправность или блокировка Комментарий masterxoloda.ru
E0 EEPROM Неисправна ППЗУ, менять плату, либо микросхему с прошивкой
E2 Communication malfunction between indoor IC and Outdoor IC Нет связи между платами управления внешнего и внутреннего блоков
E3 Communication error between outdoor IC and DSP Ошибка связи между главной платой внешнего блока и DSP (Digital Signal Processor — Цифровой Сигнальный Процессор)
E4 Malfunction of outdoor temperatur sensor Ошибка внешнего датчика температуры
E5 Voltage protection of compressor Защита компрессора от напряжения питания, находящегося не в норме
E6 PFC module of protection Power Factor Correction — Корректор Коэффициента Мощности. Только для однофазных моделей 30, 36, 48
P0 Top temperature compressor of protection Защиту по датчику температуры, установленному в верхней части компрессора
P1 High pressure protection Защита по высокому давлению
P2 Low pressure protection Ошибка по низкому давлению
P3 Current protection of compresor Защита компрессора от превышения ток
P4 Discharge temperature protection of compressor Высокая температура нагнетания газа из компрессора
P5 High temperature protection of compressor Защита компрессора от перегрева
P6 module protection

Алгоритм поиска неисправностей можно найти в сервис мануале в разделе «Документация Midea»

Модели:

MS11D-07HRN1 MO11D-12HN1

MO11D-07HN1 MS11D-18HRN1

MS11D-09HRN1 MO11D-18HN1

MO11D-09HN1 MS11D-21HRN1

MS11D-12HRN1 MO11D-21HN1

MS11D-24HRN1 MO11D-24HN1

E1 — ошибка EEPROM (внутренняя энергонезависимая память)

E2 — ошибка zero-crossing signal

E3 — ошибка двигателя внутреннего вентилятора

E5 —датчик температуры внутреннего воздуха Т1 замкнут/оборван

E6 — датчик температуры испарителя Т2 замкнут/оборван

E7 -датчик температуры конденсатора Т3 замкнут/оборван

EC -утечка хладагента

E8 — ошибка двигателя вентилятора наружного блока или неправильная фазировка питания внешнего блока

E9 — ошибка соединения внутреннего и внешнего блоков

Если мигают индикаторы на панели кондиционера, код ошибки можно найти в сервис мануале в формате .pdf

Скачать

Модели

MVUH252A-VA3

MVUH280A-VA3

MVUH335A-VA3

MVUH400A-VA3

MVUH450A-VA3

E0 -соединения наружного блока неисправны, только для ведомых (slave) блоков

E1 -неправильная последовательность фаз

E2 — соединение между наружным блоком и внутренним

E3 -reserved

E4 —неисправен температурный датчик

E5 —reserved

E6 —reserved

E7 —reseved

E8 —неправильный адрес наружного блока

E9 -напряжение питания не в норме

H0 -соединение между IR341 и 780034

H1- соединение между 0537 и 780034

Подробнее: Коды ошибок Модели MVUH252A-VA3

Модели

MCA2-12HRN1-Q MCA2-18HRN1-Q MCC-18HRN1-Q MCC-24HRN1-Q

MCC-36HRN1-R MCC-48HRN1-R MCC-60HRN1-R MUB-12HRN1-Q

MUB-18HRN1-Q MUB-24HRN1-Q MUB-36HRN1-R MUB-48HRN1-R

MUB-60HRN1-R MTB-18HWN1-Q MTB-24HWN1-Q MTB-36HWN1-R

MTB-48HWN1-R MTB-60HWN1-R MHC-24HWN1-Q MHC-36HWN1-R

MHC-48HWN1-R MHC-60HWN1-R MOU-12HN1 MOU-18HN1-Q

MOU-24HN1-Q MOU-36HN1-R MOU-48HN1-R MOUA-60HN1-R

Код ошибки определяется по мигающим индикаторам на панели кондиционера инструкция в сервис мануале

смотреть раздел troubleshooting

Скачать

Модели

MS11MU-09HRDN1 MS11MU-12HRDN1

MS11MU-18HRDN1 MS11MU-24HRDN1

MO11MU-09HRDN1 MO11MU-12HRDN1

MO11MU-18HRDN1 MO11MU-24HRDN1

E0 — ошибка EEPROM (энергонезависимая память) внутреннего блока

E1 — ошибка соединения внутреннего и наружного блоков

E2 — ошибка перехода через ноль (zero-crossing signal error)

E3 -ошибка двигателя вентилятора внутреннего блока

E4 — датчик температуры внутреннего воздуха замкнут/оборван

E5 — датчик температуры испарителя замкнут/оборван

EC -утечка хладагента

Подробнее: Коды ошибок Midea MS11MU-09HRDN1

MSX 07 — MSX 18

MSX 21 — MSX 24

E1 — ошибка EEPROM

E2 — утечка тока по нулю

E3 — ошибка вентилятора внутреннего блока- нет отклика от датчика Холла электродвигателя

E4 — превышен пусковой ток при попытке запуска более четырёх раз подряд

E5 — ошибка датчика температуры воздуха внутреннего блока

E6 — ошибка датчика температуры испарителя

E7 — ошибка датчика температуры конденсатора

E8 — перепутаны фазы

E9 -ошибка соединения внутреннего и внешнего блоков

Для инверторных моделей

E0 — ошибка EEPROM

E1 — неправильное межблочное соединение (между внутренним и внешним блоком)

E2 — неправильное подключение нуль-фаза

E3 — неисправность электродвигателя вентилятора внутреннего блока

E4 — резерв

E5 — закорочен, оборван температурный датчик наружного блока

E6 — закорочен, оборван температурный датчик внутреннего блока

P0 — перегузка по току, неисправен силовой модуль (IPM)

P1 — напряжение питание не в норме (повышенное, пониженное)

P2 — высокая температура нагнетания

P3 — слишком низкая для работы кондиционера температура наружного воздуха

P4 —несправен компрессор

Мы собрали для вас все самые распространённые ошибки кондиционеров Midea и добавили информацию о том, что означают эти ошибки и как их можно исправить. Это поможет вам понять почему кондиционер Midea (Мидеа) выдает такую ошибку и что с этим можно сделать.

Коды ошибок кондиционеров Midea

Модели Midea серии MSE (18, 12, 09, 07)

Неисправность Лампочка Лампочка таймера
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Не светится Мигает
более чем минуты не работает вентилятор внутреннего блока, Мигает Не светится
Не исправен комнатный или трубный термистор внутреннего блока Мигает Горит постоянно
Ошибка платы EEROM Горит постоянно Мигает
Перепутаны фаза и нейтрально Мигает Мигает

Модели 24 и 28 Midea серии MSE

Описание неисправности Operation lamp Timer lamp Defrosting lamp Auto lamp
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Мигает Мигает Мигает Мигает
Не исправен датчик температуры внутреннего блока Не горит Мигает Не светится Не горит
Не исправен трубный датчик температуры внутреннего блока Мигает Не горит Не светится Не горит
Не исправен температурный зонд наружного блока Не горит Не светится Мигает Не горит
Отработала защита наружного блока (для 380В) или не исправен термистор наружного блока. Не горит Не горит Мигает Мигает
Перепутаны фаза и нейтрально Мигает Мигает Не светится Не горит
Ошибка платы EEROM Не горит Мигает Не светится Мигает
Обрыв межблочного кабеля для моделей на 380В Не горит Не горит Не светится Мигает

Коды ошибок Midea Модели MSE inverter

Код ошибки Тип ошибки Решение
Е0 Ошибка/неисправен EEPROM заменить плату внутреннего блока
Е1 Неправильное межблочное соединение не гарантия, возможно выгорели элементы на платах внутреннего и наружного блоков
Е2 Неправильное подключение ноль-фаза правильно подключить ноль и фазу
Е3 Неисправен мотор вентилятора внутреннего блока заменить мотор
Е4 Резервная *
Е5 Неисправны/обрыв/нет контакта термистора наружного блока проверка контактов, замена термистора
Е6 Неисправны/обрыв/нет контакта термисторы внутреннего блока проверка контактов, замена термисторов
Р0 Перегрузка по току/неисправен модуль IPM очистка теплообменников, не правильное кол-во хладагента в системе, замена модуля, проверить обмотки компрессора
Р1 Слишком высокое или слишком низкое напряжение питания не гарантия
Р2 Высокая температура нагнетания не гарантия, загрязнение теплообменников, недостаток хладагента, воздух в системе
Р3 Слишком низкая уличная температура не гарантия, отключение при -15С, включение при -12С
Р4 Неисправность компрессора проверить сопротивление обмоток компрессора

Коды ошибок сплит-систем Midea Модели 07,09,12,18 серии MSG

Описание неисправности Operation lamp Timer lamp Defrosting lamp
4 раза отработала защита компрессора по перегрузке Мигает не светится Мигает
Более минуты не включается вентилятор внутреннего блока,. не светится Мигает Мигает
Нет запускается компрессор Мигает Мигает Мигает
Не исправен трубный термистор на внутреннем блоке не светится не светится Мигает
Не исправен комнатный термистор на внутреннем блоке не светится Мигает не светится
Ошибка (сбой)EEROM Горит постоянно Мигает не светится

Коды ошибок сплит-систем Midea Модель 24 серии MSG

Мигает — Operation, Timer, Defrosting, Auto Сработало 4 раза защита компрессора по перегрузке
Мигает — Timer Не работает комнатный термистор на внутреннем блоке
Мигает — Operation Не работает трубный термистор на внутреннем блоке
Мигает — Defrosting Не работает термистор на наружном блоке
Мигает — Defrosting, Auto Сработала защита наружного блока (для 380В) или не работает термистор наружного блока
Мигает — Auto, Ошибка платы EEROM

Коды ошибок MSG-30_36HR

Индикация внутреннего блока  
Индикация светодиодов  
мигают светодиоды Operation, Timer, Defrosting Четырежды за час был превышен рабочий ток.
мигает светодиод Timer Обрыв или замыкание комнатного термистора
мигает светодиод Operation Обрыв или замыкание трубного термистора
Светодиод Defrosting мигает с частотой 5 Гц Обрыв или замыкание термистора наружного. блока
мигают светодиоды Operation, Timer, Ошибка EEPROM
мигают светодиоды Defrosting, AUTO, Ошибка наружного блока
мигает светодиод AUTO Ошибка межблочной связи
   
   
Индикация наружного блока  
Индикация светодиодов (кол-во вспышек через 2-х секундный интервал)  
5 вспышек Ошибка межблочного соединения
4 вспышки Неверная фазировка(3-х фазная модель)
3 вспышки Высокое давление
2 вспышки Оборван или замыкает термистор
1 вспышки Неисправность внутреннего блока
Горит постоянно Нормальная работа

Коды ошибок Midea MSX 07-18

Midea Коды ошибок серия MSX модели 07-18
E1 сбой EEPROM
E2 Нейтраль пробивает на землю
Е3 Ошибка управления скоростью вращения электродвигателя внутр. Блока (не опрашивается датчик Холла)
Е4 Превышение пускового тока компрессора при запуске 4 раза подряд
Е5 Ошибка по термистору воздуха внутреннего блока
Е6 Ошибка по трубному температурному датчику внутреннего блока

Коды ошибок Midea MSX 21-24

Midea Коды ошибок серия MSX модели 21-24
E1 сбой EEPROM
E4 Перегрузка по току компрессора четырежды в течение часа.
Е5 Ошибка по температурному зонду внутреннего блока по воздуху
Е6 Ошибка по трубному температурному зонду внутреннего блока
Е7 Ошибка по трубному температурному зонду внешнего блока
Е8 Перепутаны ноль и фаза
Е9 Неверное подсоединение внутреннего и внешнего блока (неверная коммуникация)

error code of unitary Midea

Самодиагностика   
Внутренний блок      
тип содержание индикация примечание
1 защита Четырежды сработала перегрузка компрессора по току мигают LED operation+timer+defrosting кондиционер не включается. Ошибка сбрасывается после полного отключения от электросети
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer
Наружный блок      
модели трехфазные 36, 48, 60 kBTU, наружный блок универсального типа  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка Низкое давление кипения мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внешнего блока MDV

Код ошибки Описание
Е1 Ошибка по фазному монитору (перепутаны фазы, отсутствие одной из фаз)
Е2 Нарушение межблочной связи внутренникнаружник
Е3 Не работаетнет контакта с датчиком температуры Т3
Е4 Не работаетнет контакта с датчиком температуры Т4
Е5 Не работаетнет контакта с датчиком температуры Т5
Е6 Превышение уровня воды в поддоне кассетного внутренника
Е7 Не работаетнет контакта с датчиком температуры Т6
Е8 Неправильный адрес наружнего блока
Р1 Защита по высокому давлению
Р2 Защита по низкому давлению
Р3 Токовая защита компрессора
Р4 Защита по высокой температуре нагнетания
Р5 Превышение температуры конденсации

Коды ошибок внешних блоков для все моделей полупрома

Наружный блок        
модели трехфазные 36, 48, 60 kBTU, универсальный наружный блок  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка защита по низкому давлению мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внутреннего блока серий MCC & MUC

Коды ошибок внутреннего блока серии МСС(МUC)
Индицируются на дисплее
Код Тип ошибки Действия
Е2 нет контакта/не исправен термистор по воздуху проверить контакт/заменить термистор по воздуху
Е3 нет контакта/не исправен термистор испарителя проверить контакт/заменить термистора испарителя
Е4* нет контакта/не исправен термистор конденсатора проверить контакт/заменить термистора конденсатора
Е5*** нет контакта/неисправен датчик уровня конденсата в поддоне проверить контакт/заменить датчик
Е6** ошибка/неисправность наружного блока смотреть ошибки на плате наружного блока
Е7 ошибка EEPROM внутреннего блока заменить/перепрограммировать EEPROM внутреннего блока
Е8*** переполнение поддона конденсатом проверить дренажную систему и работу помпы
* — только однофазные модели!
** — только трехфазные модели
*** — MCC

Коды ошибок внутренних блоков серий MUA & MCA

Самодиагностика      
Внутренний блок      
тип содержание индикация примечание
1 защита перегрузка по току, 4 раза за 1 час мигают LED operation+timer+defrosting кондиционер не работает, сброс ошибки отключением электропитания
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer

Коды ошибок мобильного к-ра серии EACM

Коды ошибок мобильного кондиционера М-серии
Индицируются на дисплее
Код Тип ошибки Действия
Р1 переполнение по уровню 1(верхний поддон) слить конденсат через верхнюю заглушку
Р2 переполнение по уровню 2(нижний поддон) слить конденсат через нижнюю заглушку
Е1 нет контакта/неисправен термистор Т1 проверить контакт/заменить термистор Т1
Е2 нет контакта/неисправен термистор Т2 проверить контакт/заменить термистор Т2
Е3 нет контакта/неисправен термистор Т3 проверить контакт/заменить термистор Т3

Мы не рекомендуем проводить ремонтные работы самостоятельно, лучше довериться специалистам нашей компании, которые в кратчайшие сроки устранят неисправность, продлят жизнь вашей технике, дадут гарантию на выполненную работу и при этом, вы не будите рисковать тем, что можете поломать дорогостоящее оборудование или случайно допустить утечку хладагента.

 Почему выгодно обращаться в компанию Климатхол: 

  • У нас всегда качественное обслуживание;
  • Мы всегда устанавливаем только оригинальные детали;
  • Мы проводим работы в удобное для вас время;
  • Мы даем гарантию на все услуги;
  • У нас очень приятные цены;
  • Мы сможем быстро и качественно устранить любую поломку;
  • Все наши мастера имеют опыт работы в сфере ремонта и обслуживания кондиционеров более 3 лет;
  • Но главное – вы в кратчайшие сроки получите рабочую технику. 

Услуги нашей компании:

  1. Заправка кондиционеров;
  2. Чистка кондиционеров;
  3. Демонтаж кондиционеров;
  4. Обслуживание кондиционеров;
  5. Подробный прайс на ремонт и обслуживание кондиционеров.

Модели 07,09,12,18 Midea серии MSE

Неисправность Operation lamp Timer lamp
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Не светится Мигает
более чем минуты не работает вентилятор внутреннего блока, Мигает Не светится
Не исправен комнатный или трубный термистор внутреннего блока Мигает Горит постоянно
Ошибка платы EEROM Горит постоянно Мигает
Перепутаны фаза и нейтрально Мигает Мигает

Модели 24 и 28 Midea серии MSE

Описание неисправности Operation lamp Timer lamp Defrosting lamp Auto lamp
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Мигает Мигает Мигает Мигает
Не исправен датчик температуры внутреннего блока Не горит Мигает Не светится Не горит
Не исправен трубный датчик температуры внутреннего блока Мигает Не горит Не светится Не горит
Не исправен температурный зонд наружного блока Не горит Не светится Мигает Не горит
Отработала защита наружного блока (для 380В) или не исправен термистор наружного блока. Не горит Не горит Мигает Мигает
Перепутаны фаза и нейтрально Мигает Мигает Не светится Не горит
Ошибка платы EEROM Не горит Мигает Не светится Мигает
Обрыв межблочного кабеля для моделей на 380В Не горит Не горит Не светится Мигает

Коды ошибок Midea Модели MSE inverter

Код ошибки Тип ошибки Решение
Е0 Ошибка/неисправен EEPROM заменить плату внутреннего блока
Е1 Неправильное межблочное соединение не гарантия, возможно выгорели элементы на платах внутреннего и наружного блоков
Е2 Неправильное подключение ноль-фаза правильно подключить ноль и фазу
Е3 Неисправен мотор вентилятора внутреннего блока заменить мотор
Е4 Резервная *
Е5 Неисправны/обрыв/нет контакта термистора наружного блока проверка контактов, замена термистора
Е6 Неисправны/обрыв/нет контакта термисторы внутреннего блока проверка контактов, замена термисторов
Р0 Перегрузка по току/неисправен модуль IPM очистка теплообменников, не правильное кол-во хладагента в системе, замена модуля, проверить обмотки компрессора
Р1 Слишком высокое или слишком низкое напряжение питания не гарантия
Р2 Высокая температура нагнетания не гарантия, загрязнение теплообменников, недостаток хладагента, воздух в системе
Р3 Слишком низкая уличная температура не гарантия, отключение при -15С, включение при -12С
Р4 Неисправность компрессора проверить сопротивление обмоток компрессора

Коды ошибок сплит-систем Midea Модели 07,09,12,18 серии MSG

Описание неисправности Operation lamp Timer lamp Defrosting lamp
4 раза отработала защита компрессора по перегрузке Мигает не светится Мигает
Более минуты не включается вентилятор внутреннего блока,. не светится Мигает Мигает
Нет запускается компрессор Мигает Мигает Мигает
Не исправен трубный термистор на внутреннем блоке не светится не светится Мигает
Не исправен комнатный термистор на внутреннем блоке не светится Мигает не светится
Ошибка (сбой)EEROM Горит постоянно Мигает не светится

Коды ошибок сплит-систем Midea Модель 24 серии MSG

Мигает — Operation, Timer, Defrosting, Auto Сработало 4 раза защита компрессора по перегрузке
Мигает — Timer Не работает комнатный термистор на внутреннем блоке
Мигает — Operation Не работает трубный термистор на внутреннем блоке
Мигает — Defrosting Не работает термистор на наружном блоке
Мигает — Defrosting, Auto Сработала защита наружного блока (для 380В) или не работает термистор наружного блока
Мигает — Auto, Ошибка платы EEROM

Коды ошибок MSG-30_36HR

Индикация внутреннего блока  
Индикация светодиодов  
мигают светодиоды Operation, Timer, Defrosting Четырежды за час был превышен рабочий ток.
мигает светодиод Timer Обрыв или замыкание комнатного термистора
мигает светодиод Operation Обрыв или замыкание трубного термистора
Светодиод Defrosting мигает с частотой 5 Гц Обрыв или замыкание термистора наружного. блока
мигают светодиоды Operation, Timer, Ошибка EEPROM
мигают светодиоды Defrosting, AUTO, Ошибка наружного блока
мигает светодиод AUTO Ошибка межблочной связи
   
   
Индикация наружного блока  
Индикация светодиодов (кол-во вспышек через 2-х секундный интервал)  
5 вспышек Ошибка межблочного соединения
4 вспышки Неверная фазировка(3-х фазная модель)
3 вспышки Высокое давление
2 вспышки Оборван или замыкает термистор
1 вспышки Неисправность внутреннего блока
Горит постоянно Нормальная работа

Коды ошибок Midea MSX 07-18

Midea Коды ошибок серия MSX модели 07-18
E1 сбой EEPROM
E2 Нейтраль пробивает на землю
Е3 Ошибка управления скоростью вращения электродвигателя внутр. Блока (не опрашивается датчик Холла)
Е4 Превышение пускового тока компрессора при запуске 4 раза подряд
Е5 Ошибка по термистору воздуха внутреннего блока
Е6 Ошибка по трубному температурному датчику внутреннего блока

Коды ошибок Midea MSX 21-24

Midea Коды ошибок серия MSX модели 21-24
E1 сбой EEPROM
E4 Перегрузка по току компрессора четырежды в течение часа.
Е5 Ошибка по температурному зонду внутреннего блока по воздуху
Е6 Ошибка по трубному температурному зонду внутреннего блока
Е7 Ошибка по трубному температурному зонду внешнего блока
Е8 Перепутаны ноль и фаза
Е9 Неверное подсоединение внутреннего и внешнего блока (неверная коммуникация)

error code of unitary Midea

Самодиагностика   
Внутренний блок      
тип содержание индикация примечание
1 защита Четырежды сработала перегрузка компрессора по току мигают LED operation+timer+defrosting кондиционер не включается. Ошибка сбрасывается после полного отключения от электросети
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer
Наружный блок      
модели трехфазные 36, 48, 60 kBTU, наружный блок универсального типа  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка Низкое давление кипения мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внешнего блока MDV

Код ошибки Описание
Е1 Ошибка по фазному монитору (перепутаны фазы, отсутствие одной из фаз)
Е2 Нарушение межблочной связи внутренникнаружник
Е3 Не работаетнет контакта с датчиком температуры Т3
Е4 Не работаетнет контакта с датчиком температуры Т4
Е5 Не работаетнет контакта с датчиком температуры Т5
Е6 Превышение уровня воды в поддоне кассетного внутренника
Е7 Не работаетнет контакта с датчиком температуры Т6
Е8 Неправильный адрес наружнего блока
Р1 Защита по высокому давлению
Р2 Защита по низкому давлению
Р3 Токовая защита компрессора
Р4 Защита по высокой температуре нагнетания
Р5 Превышение температуры конденсации

Коды ошибок внешних блоков для все моделей полупрома

Наружный блок        
модели трехфазные 36, 48, 60 kBTU, универсальный наружный блок  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка защита по низкому давлению мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внутреннего блока серий MCC & MUC

Коды ошибок внутреннего блока серии МСС(МUC)
Индицируются на дисплее
Код Тип ошибки Действия
Е2 нет контакта/не исправен термистор по воздуху проверить контакт/заменить термистор по воздуху
Е3 нет контакта/не исправен термистор испарителя проверить контакт/заменить термистора испарителя
Е4* нет контакта/не исправен термистор конденсатора проверить контакт/заменить термистора конденсатора
Е5*** нет контакта/неисправен датчик уровня конденсата в поддоне проверить контакт/заменить датчик
Е6** ошибка/неисправность наружного блока смотреть ошибки на плате наружного блока
Е7 ошибка EEPROM внутреннего блока заменить/перепрограммировать EEPROM внутреннего блока
Е8*** переполнение поддона конденсатом проверить дренажную систему и работу помпы
* — только однофазные модели!
** — только трехфазные модели
*** — MCC

Коды ошибок внутренних блоков серий MUA & MCA

Самодиагностика      
Внутренний блок      
тип содержание индикация примечание
1 защита перегрузка по току, 4 раза за 1 час мигают LED operation+timer+defrosting кондиционер не работает, сброс ошибки отключением электропитания
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer

Коды ошибок мобильного к-ра серии EACM

Коды ошибок мобильного кондиционера М-серии
Индицируются на дисплее
Код Тип ошибки Действия
Р1 переполнение по уровню 1(верхний поддон) слить конденсат через верхнюю заглушку
Р2 переполнение по уровню 2(нижний поддон) слить конденсат через нижнюю заглушку
Е1 нет контакта/неисправен термистор Т1 проверить контакт/заменить термистор Т1
Е2 нет контакта/неисправен термистор Т2 проверить контакт/заменить термистор Т2
Е3 нет контакта/неисправен термистор Т3 проверить контакт/заменить термистор Т3

Подбор продажа монтаж тепловых насосов кондиционеров и др.

Серия Midea LCAC DC Inverter

Внутренние кассетные четырёхпоточные модели:

Ошибка running lamp timer lamp defrosting alarm lamp Malfunction Комментарий masterxoloda.ru
E1 Led2 Quik Flash In-Outdoor unit communication cheking channel is abnormal Нет связи между внутренним и внешним блоком
E2 Led 1 Quik Flash Room temerature sensor cheking channel is abnormal Неисправен — закорочен или оборван датчик температуры воздуха
E3 Led 1 Quik Flash Pipe temerature T2 sensor cheking channel is abnormal Неисправен датчик температуры испарителя (разъём CN12 на плате)
E4 Led 1 Quik Flash Pipe temerature T2B temerature sensor cheking channel is abnormal Неисправен датчик температуры а выходе из испарителя (разъём CN7 на плате)
EE Led 4 Quik Flash Water-level alarm malfunction Ошибка переполнения дренажного поддона конденсатом
E0 Led 3 Quik Flash Collision model malfunction Несоответствие моделей кондиционера
E7 Led 1 Quik Flash EEPROM Неисправна ППЗУ, менять плату, либо микросхему с прошивкой
Ed Led 4 Quik Flash Outdoor malfunction Неисправен внешний блок, смотреть ошибки для него

Для напольно — потолочных внутренних блоков:

Ошибка running lamp timer lamp defrosting alarm lamp Malfunction Комментарий masterxoloda.ru
¤ In-Outdoor unit communication cheking channel is abnormal Нет связи между внутренним и внешним блоком
¤ Room temerature sensor cheking channel is abnormal Неисправен — закорочен или оборван датчик температуры воздуха
¤ Water-level alarm malfunction Ошибка переполнения дренажного поддона конденсатом
¤ Collision model malfunction Несоответствие моделей кондиционера
slow flash Outdoor malfunction Неисправен внешний блок, смотреть ошибки для него

Для канальных кондиционеров:

Ошибка operation timer DEF.FAN alarm Malfunction Комментарий masterxoloda.ru
E1 Flash. 5 Hz In-Outdoor unit communication cheking channel is abnormal Нет связи между внутренним и внешним блоком
E2 Flash. 5 Hz Room temerature sensor cheking channel is abnormal Неисправен — закорочен или оборван датчик температуры воздуха
E3 Flash. 5 Hz Pipe temerature T2 sensor cheking channel is abnormal Неисправен датчик температуры испарителя (разъём CN12 на плате)
E4 Flash. 5 Hz Pipe temerature T2B temerature sensor cheking channel is abnormal Неисправен датчик температуры а выходе из испарителя (разъём CN7 на плате)
EE Flash. 5 Hz Water-level alarm malfunction Ошибка переполнения дренажного поддона конденсатом
E0 Flash. 5 Hz Collision model malfunction Несоответствие моделей кондиционера
E7 Flash. 1 Hz EEPROM Неисправна ППЗУ, менять плату, либо микросхему с прошивкой
Ed Flash. 1 Hz Outdoor malfunction Неисправен внешний блок, смотреть ошибки для него
CP Flash. 1 Hz Be closed by the remote control function На пульте управления включена функция блокировки
Light Light Avoid cold fan and defrost Работает функция разморозки во избежание задевания вентилятором наледи

Ошибки внешних блоков:

Код ошибки Неисправность или блокировка Комментарий masterxoloda.ru
E0 EEPROM Неисправна ППЗУ, менять плату, либо микросхему с прошивкой
E2 Communication malfunction between indoor IC and Outdoor IC Нет связи между платами управления внешнего и внутреннего блоков
E3 Communication error between outdoor IC and DSP Ошибка связи между главной платой внешнего блока и DSP (Digital Signal Processor — Цифровой Сигнальный Процессор)
E4 Malfunction of outdoor temperatur sensor Ошибка внешнего датчика температуры
E5 Voltage protection of compressor Защита компрессора от напряжения питания, находящегося не в норме
E6 PFC module of protection Power Factor Correction — Корректор Коэффициента Мощности. Только для однофазных моделей 30, 36, 48
P0 Top temperature compressor of protection Защиту по датчику температуры, установленному в верхней части компрессора
P1 High pressure protection Защита по высокому давлению
P2 Low pressure protection Ошибка по низкому давлению
P3 Current protection of compresor Защита компрессора от превышения ток
P4 Discharge temperature protection of compressor Высокая температура нагнетания газа из компрессора
P5 High temperature protection of compressor Защита компрессора от перегрева
P6 module protection

Алгоритм поиска неисправностей можно найти в сервис мануале в разделе «Документация Midea»

Модели:

MS11D-07HRN1 MO11D-12HN1

MO11D-07HN1 MS11D-18HRN1

MS11D-09HRN1 MO11D-18HN1

MO11D-09HN1 MS11D-21HRN1

MS11D-12HRN1 MO11D-21HN1

MS11D-24HRN1 MO11D-24HN1

E1 — ошибка EEPROM (внутренняя энергонезависимая память)

E2 — ошибка zero-crossing signal

E3 — ошибка двигателя внутреннего вентилятора

E5 —датчик температуры внутреннего воздуха Т1 замкнут/оборван

E6 — датчик температуры испарителя Т2 замкнут/оборван

E7 -датчик температуры конденсатора Т3 замкнут/оборван

EC -утечка хладагента

E8 — ошибка двигателя вентилятора наружного блока или неправильная фазировка питания внешнего блока

E9 — ошибка соединения внутреннего и внешнего блоков

Если мигают индикаторы на панели кондиционера, код ошибки можно найти в сервис мануале в формате .pdf

Скачать

Модели

MVUH252A-VA3

MVUH280A-VA3

MVUH335A-VA3

MVUH400A-VA3

MVUH450A-VA3

E0 -соединения наружного блока неисправны, только для ведомых (slave) блоков

E1 -неправильная последовательность фаз

E2 — соединение между наружным блоком и внутренним

E3 -reserved

E4 —неисправен температурный датчик

E5 —reserved

E6 —reserved

E7 —reseved

E8 —неправильный адрес наружного блока

E9 -напряжение питания не в норме

H0 -соединение между IR341 и 780034

H1- соединение между 0537 и 780034

Подробнее: Коды ошибок Модели MVUH252A-VA3

Модели

MCA2-12HRN1-Q MCA2-18HRN1-Q MCC-18HRN1-Q MCC-24HRN1-Q

MCC-36HRN1-R MCC-48HRN1-R MCC-60HRN1-R MUB-12HRN1-Q

MUB-18HRN1-Q MUB-24HRN1-Q MUB-36HRN1-R MUB-48HRN1-R

MUB-60HRN1-R MTB-18HWN1-Q MTB-24HWN1-Q MTB-36HWN1-R

MTB-48HWN1-R MTB-60HWN1-R MHC-24HWN1-Q MHC-36HWN1-R

MHC-48HWN1-R MHC-60HWN1-R MOU-12HN1 MOU-18HN1-Q

MOU-24HN1-Q MOU-36HN1-R MOU-48HN1-R MOUA-60HN1-R

Код ошибки определяется по мигающим индикаторам на панели кондиционера инструкция в сервис мануале

смотреть раздел troubleshooting

Скачать

Модели

MS11MU-09HRDN1 MS11MU-12HRDN1

MS11MU-18HRDN1 MS11MU-24HRDN1

MO11MU-09HRDN1 MO11MU-12HRDN1

MO11MU-18HRDN1 MO11MU-24HRDN1

E0 — ошибка EEPROM (энергонезависимая память) внутреннего блока

E1 — ошибка соединения внутреннего и наружного блоков

E2 — ошибка перехода через ноль (zero-crossing signal error)

E3 -ошибка двигателя вентилятора внутреннего блока

E4 — датчик температуры внутреннего воздуха замкнут/оборван

E5 — датчик температуры испарителя замкнут/оборван

EC -утечка хладагента

Подробнее: Коды ошибок Midea MS11MU-09HRDN1

MSX 07 — MSX 18

MSX 21 — MSX 24

E1 — ошибка EEPROM

E2 — утечка тока по нулю

E3 — ошибка вентилятора внутреннего блока- нет отклика от датчика Холла электродвигателя

E4 — превышен пусковой ток при попытке запуска более четырёх раз подряд

E5 — ошибка датчика температуры воздуха внутреннего блока

E6 — ошибка датчика температуры испарителя

E7 — ошибка датчика температуры конденсатора

E8 — перепутаны фазы

E9 -ошибка соединения внутреннего и внешнего блоков

Для инверторных моделей

E0 — ошибка EEPROM

E1 — неправильное межблочное соединение (между внутренним и внешним блоком)

E2 — неправильное подключение нуль-фаза

E3 — неисправность электродвигателя вентилятора внутреннего блока

E4 — резерв

E5 — закорочен, оборван температурный датчик наружного блока

E6 — закорочен, оборван температурный датчик внутреннего блока

P0 — перегузка по току, неисправен силовой модуль (IPM)

P1 — напряжение питание не в норме (повышенное, пониженное)

P2 — высокая температура нагнетания

P3 — слишком низкая для работы кондиционера температура наружного воздуха

P4 —несправен компрессор

  • Главная

  • Библиотека

  • Коды ошибок кондиционеров

  • Коды ошибок кондиционеров Midea


  • Коды ошибок


  • Каталоги по эксплуатации


  • Полезные статьи


  • История брендов


  • Вентиляция

Модели 07,09,12,18 Midea серии MSE

Неисправность Operation lamp Timer lamp
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Не светится Мигает
более чем минуты не работает вентилятор внутреннего блока, Мигает Не светится
Не исправен комнатный или трубный термистор внутреннего блока Мигает Горит постоянно
Ошибка платы EEROM Горит постоянно Мигает
Перепутаны фаза и нейтрально Мигает Мигает

Модели 24 и 28 Midea серии MSE

Описание неисправности Operation lamp Timer lamp Defrosting lamp Auto lamp
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Мигает Мигает Мигает Мигает
Не исправен датчик температуры внутреннего блока Не горит Мигает Не светится Не горит
Не исправен трубный датчик температуры внутреннего блока Мигает Не горит Не светится Не горит
Не исправен температурный зонд наружного блока Не горит Не светится Мигает Не горит
Отработала защита наружного блока (для 380В) или не исправен термистор наружного блока. Не горит Не горит Мигает Мигает
Перепутаны фаза и нейтрально Мигает Мигает Не светится Не горит
Ошибка платы EEROM Не горит Мигает Не светится Мигает
Обрыв межблочного кабеля для моделей на 380В Не горит Не горит Не светится Мигает

Коды ошибок Midea Модели MSE inverter

Код ошибки Тип ошибки Решение
Е0 Ошибка/неисправен EEPROM заменить плату внутреннего блока
Е1 Неправильное межблочное соединение не гарантия, возможно выгорели элементы на платах внутреннего и наружного блоков
Е2 Неправильное подключение ноль-фаза правильно подключить ноль и фазу
Е3 Неисправен мотор вентилятора внутреннего блока заменить мотор
Е4 Резервная *
Е5 Неисправны/обрыв/нет контакта термистора наружного блока проверка контактов, замена термистора
Е6 Неисправны/обрыв/нет контакта термисторы внутреннего блока проверка контактов, замена термисторов
Р0 Перегрузка по току/неисправен модуль IPM очистка теплообменников, не правильное кол-во хладагента в системе, замена модуля, проверить обмотки компрессора
Р1 Слишком высокое или слишком низкое напряжение питания не гарантия
Р2 Высокая температура нагнетания не гарантия, загрязнение теплообменников, недостаток хладагента, воздух в системе
Р3 Слишком низкая уличная температура не гарантия, отключение при -15С, включение при -12С
Р4 Неисправность компрессора проверить сопротивление обмоток компрессора

Коды ошибок сплит-систем Midea Модели 07,09,12,18 серии MSG

Описание неисправности Operation lamp Timer lamp Defrosting lamp
4 раза отработала защита компрессора по перегрузке Мигает не светится Мигает
Более минуты не включается вентилятор внутреннего блока,. не светится Мигает Мигает
Нет запускается компрессор Мигает Мигает Мигает
Не исправен трубный термистор на внутреннем блоке не светится не светится Мигает
Не исправен комнатный термистор на внутреннем блоке не светится Мигает не светится
Ошибка (сбой)EEROM Горит постоянно Мигает не светится

Коды ошибок сплит-систем Midea Модель 24 серии MSG

Мигает — Operation, Timer, Defrosting, Auto Сработало 4 раза защита компрессора по перегрузке
Мигает — Timer Не работает комнатный термистор на внутреннем блоке
Мигает — Operation Не работает трубный термистор на внутреннем блоке
Мигает — Defrosting Не работает термистор на наружном блоке
Мигает — Defrosting, Auto Сработала защита наружного блока (для 380В) или не работает термистор наружного блока
Мигает — Auto, Ошибка платы EEROM

Коды ошибок MSG-30_36HR

Индикация внутреннего блока  
Индикация светодиодов  
мигают светодиоды Operation, Timer, Defrosting Четырежды за час был превышен рабочий ток.
мигает светодиод Timer Обрыв или замыкание комнатного термистора
мигает светодиод Operation Обрыв или замыкание трубного термистора
Светодиод Defrosting мигает с частотой 5 Гц Обрыв или замыкание термистора наружного. блока
мигают светодиоды Operation, Timer, Ошибка EEPROM
мигают светодиоды Defrosting, AUTO, Ошибка наружного блока
мигает светодиод AUTO Ошибка межблочной связи
   
   
Индикация наружного блока  
Индикация светодиодов (кол-во вспышек через 2-х секундный интервал)  
5 вспышек Ошибка межблочного соединения
4 вспышки Неверная фазировка(3-х фазная модель)
3 вспышки Высокое давление
2 вспышки Оборван или замыкает термистор
1 вспышки Неисправность внутреннего блока
Горит постоянно Нормальная работа

Коды ошибок Midea MSX 07-18

Midea Коды ошибок серия MSX модели 07-18
E1 сбой EEPROM
E2 Нейтраль пробивает на землю
Е3 Ошибка управления скоростью вращения электродвигателя внутр. Блока (не опрашивается датчик Холла)
Е4 Превышение пускового тока компрессора при запуске 4 раза подряд
Е5 Ошибка по термистору воздуха внутреннего блока
Е6 Ошибка по трубному температурному датчику внутреннего блока

Коды ошибок Midea MSX 21-24

Midea Коды ошибок серия MSX модели 21-24
E1 сбой EEPROM
E4 Перегрузка по току компрессора четырежды в течение часа.
Е5 Ошибка по температурному зонду внутреннего блока по воздуху
Е6 Ошибка по трубному температурному зонду внутреннего блока
Е7 Ошибка по трубному температурному зонду внешнего блока
Е8 Перепутаны ноль и фаза
Е9 Неверное подсоединение внутреннего и внешнего блока (неверная коммуникация)
Самодиагностика   
Внутренний блок      
тип содержание индикация примечание
1 защита Четырежды сработала перегрузка компрессора по току мигают LED operation+timer+defrosting кондиционер не включается. Ошибка сбрасывается после полного отключения от электросети
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer
Наружный блок      
модели трехфазные 36, 48, 60 kBTU, наружный блок универсального типа  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка Низкое давление кипения мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внешнего блока MDV

Код ошибки Описание
Е1 Ошибка по фазному монитору (перепутаны фазы, отсутствие одной из фаз)
Е2 Нарушение межблочной связи внутренникнаружник
Е3 Не работаетнет контакта с датчиком температуры Т3
Е4 Не работаетнет контакта с датчиком температуры Т4
Е5 Не работаетнет контакта с датчиком температуры Т5
Е6 Превышение уровня воды в поддоне кассетного внутренника
Е7 Не работаетнет контакта с датчиком температуры Т6
Е8 Неправильный адрес наружнего блока
Р1 Защита по высокому давлению
Р2 Защита по низкому давлению
Р3 Токовая защита компрессора
Р4 Защита по высокой температуре нагнетания
Р5 Превышение температуры конденсации

Коды ошибок внешних блоков для все моделей полупрома

Наружный блок        
модели трехфазные 36, 48, 60 kBTU, универсальный наружный блок  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка защита по низкому давлению мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внутреннего блока серий MCC & MUC

Коды ошибок внутреннего блока серии МСС(МUC)
Индицируются на дисплее
Код Тип ошибки Действия
Е2 нет контакта/не исправен термистор по воздуху проверить контакт/заменить термистор по воздуху
Е3 нет контакта/не исправен термистор испарителя проверить контакт/заменить термистора испарителя
Е4* нет контакта/не исправен термистор конденсатора проверить контакт/заменить термистора конденсатора
Е5*** нет контакта/неисправен датчик уровня конденсата в поддоне проверить контакт/заменить датчик
Е6** ошибка/неисправность наружного блока смотреть ошибки на плате наружного блока
Е7 ошибка EEPROM внутреннего блока заменить/перепрограммировать EEPROM внутреннего блока
Е8*** переполнение поддона конденсатом проверить дренажную систему и работу помпы
* — только однофазные модели!
** — только трехфазные модели
*** — MCC

Коды ошибок внутренних блоков серий MUA & MCA

Самодиагностика      
Внутренний блок      
тип содержание индикация примечание
1 защита перегрузка по току, 4 раза за 1 час мигают LED operation+timer+defrosting кондиционер не работает, сброс ошибки отключением электропитания
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer

Коды ошибок мобильного к-ра серии EACM

Коды ошибок мобильного кондиционера М-серии
Индицируются на дисплее
Код Тип ошибки Действия
Р1 переполнение по уровню 1(верхний поддон) слить конденсат через верхнюю заглушку
Р2 переполнение по уровню 2(нижний поддон) слить конденсат через нижнюю заглушку
Е1 нет контакта/неисправен термистор Т1 проверить контакт/заменить термистор Т1
Е2 нет контакта/неисправен термистор Т2 проверить контакт/заменить термистор Т2
Е3 нет контакта/неисправен термистор Т3 проверить контакт/заменить термистор Т3

Коды ошибок кондиционеров

Коды ошибок кондиционеров производимых на заводе Midea,  Китай

Внимание! повышенный шум  наружного блока кондиционера включенного на тепло не является неисправностью!

Коды ошибок кондиционеров Midea серии MSE
Для инверторных моделей
E0 — ошибка EEPROM
E1 — неправильное межблочное соединение (между внутренним и внешним блоком)
E2 — неправильное подключение нуль-фаза
E3 — неисправность электродвигателя вентилятора внутреннего блока
E4 — резерв
E5 — закорочен, оборван температурный датчик наружного блока
E6 — закорочен, оборван температурный датчик внутреннего блока
P0 — перегузка по току, неисправен силовой модуль (IPM)
P1 — напряжение питание не в норме (повышенное, пониженное)
P2 — высокая температура нагнетания
P3 — слишком низкая для работы кондиционера температура наружного воздуха
P4 -несправен компрессор
Коды ошибок кондиционеров Midea серии MSX
MSX 07 — MSX 18
MSX 21 — MSX 24
E1 — ошибка EEPROM
E2 — утечка тока по нулю
E3 — ошибка вентилятора внутреннего блока- нет отклика от датчика Холла электродвигателя
E4 — превышен пусковой ток при попытке запуска более четырёх раз подряд
E5 — ошибка датчика температуры воздуха внутреннего блока
E6 — ошибка датчика температуры испарителя
E7 — ошибка датчика температуры конденсатора
E8 — перепутаны фазы
E9 -ошибка соединения внутреннего и внешнего блоков

Коды ошибок Midea MS11MU-09HRDN1
Модели:
MS11MU-09HRDN1 MS11MU-12HRDN1
MS11MU-18HRDN1 MS11MU-24HRDN1
MO11MU-09HRDN1 MO11MU-12HRDN1
MO11MU-18HRDN1 MO11MU-24HRDN1
E0 — ошибка EEPROM (энергонезависимая память) внутреннего блока
E1 — ошибка соединения внутреннего и наружного блоков
E2 — ошибка перехода через ноль (zero-crossing signal error)
E3 -ошибка двигателя вентилятора внутреннего блока
E4 — датчик температуры внутреннего воздуха замкнут/оборван
E5  — датчик температуры испарителя замкнут/оборван
EC -утечка хладагента

Коды ошибок Модели MVUH252A-VA3
Модели:
MVUH252A-VA3
MVUH280A-VA3
MVUH335A-VA3
MVUH400A-VA3
MVUH450A-VA3
E0 -соединения наружного блока неисправны, только для ведомых (slave) блоков
E1 -неправильная последовательность фаз
E2 — соединение между наружным блоком и внутренним
E3 -reserved
E4 -неисправен температурный датчик
E5 -reserved
E6 -reserved
E7 -reseved
E8 -неправильный адрес наружного блока
E9 -напряжение питания не в норме
H0 -соединение между IR341 и 780034
H1- соединение между 0537 и 780034

Коды ошибок Midea MS11D-07HRN1
Коды ошибок кондиционеров Midea моделей:
MS11D-07HRN1 MO11D-12HN1
MO11D-07HN1  MS11D-18HRN1
MS11D-09HRN1 MO11D-18HN1
MO11D-09HN1  MS11D-21HRN1
MS11D-12HRN1  MO11D-21HN1
MS11D-24HRN1  MO11D-24HN1
E1 — ошибка EEPROM (внутренняя энергонезависимая память)
E2 — ошибка zero-crossing signal
E3 — ошибка двигателя внутреннего вентилятора
E5 -датчик температуры внутреннего воздуха Т1 замкнут/оборван
E6 — датчик температуры испарителя Т2 замкнут/оборван
E7 -датчик температуры конденсатора Т3 замкнут/оборван
EC -утечка хладагента
E8 — ошибка двигателя вентилятора наружного блока или неправильная фазировка питания внешнего блока
E9 — ошибка соединения внутреннего и внешнего блоков

коды ошибок кондиционеров Mitsubishi

daikin_remont_cod

тел. +7-937-225-42-40

Кондиционеры Мидеа активней стали продаваться на рынке стран СНГ, а в особенности в России. Продукция данной торговой марки сертифицирована по международным стандартам качества, безопасна для использования и разнообразна по ценовым группам и мощности. Компания выпускает несколько линеек кондиционеров, в каждой из которой есть свой набор ошибок, сигнализирующий о тех или иных проблемах с техникой. Рассмотрим самые типовые ошибки, которые появляются практически во всех устройствам подобного типа от Midea.

Коды ошибок кондиционеров Мидеа

Популярными на территории нашей страны остаются кондиционеры:

  • Midea MFE 60ae;
  • Midea MVUH;
  • Midea Type Rg70a BGEF;
  • Midea VRF;
  • Midea MDV.

Все представленные модели занимают около 65% рынка, это учитывая модификации на их основе. Ошибки указываются на переднем дисплее, а также световыми сигналами от индикаторов. В некоторых моделях код ошибки можно узнать лишь при диагностике при помощи специального оборудования. Типовыми ошибками, которые высвечиваются на дисплее, являются:

  • Ошибка Е1 – нарушение связи между внутренней частью и внешним блоком, часто требуется произвести диагностику или переустановку связывающих звеньев.
  • Ошибка Е2 – проблемы в датчике температуры воздуха. В этом случае может быть виной короткое замыкание или физический обрыв устройства. В некоторых моделях так
  • Ошибка Е3 –проблемы с датчиком температуры испарителя. В инверторных моделях ошибка обозначает неисправность электродвигателя вентилятора внутреннего блока.
  • Ошибка Е4 – проблемы с датчиком температуры на выходе испарителя. В некоторых моделях эта ошибка вакантна.
  • Ошибка Е5 – неисправности датчика температуры внутреннего или внешнего блока в зависимости от модели кондиционера. В инверторных моделях – внешний датчик закорочен или оборван. В большинстве сплит-систем ошибка Е5 вакантна или превышен пусковой ток при попытке запуска более четырёх раз подряд.
  • Ошибка Ed – указывает на неисправность внешнего блока. Зачастую, это может указывать на наличие преграды для работы лопастей, но чаще всего проблема в компрессоре, что не позволяет работать устройству.
  • Ошибка Cf – эта ошибка указывает на наличие проблем с датчиком, отвечающим за высокое давление среды внутри системы. Данная ошибка опасна, так как возможно, что датчик в норме, при этом сама система разгерметизирована. Такая ошибка встроена не во все кондиционеры Мидеа, а лишь в некоторые модели.
  • Ошибка Ec – в большинство современных кондиционеров производитель встроил программно ошибку ЕС, которая пришла на смену CF, ЕС показывает, что из системы кондиционирования вытекает хладагент. В этом случае нужно в срочном порядке вызывать мастера для ремонта и дозаправки кондиционера.
  • Ошибка Р4 – указывает на высокую температуру нагнетания газа, что говорит о неисправности испарителя и всей системы в целом.

Это базовые ошибки, которые встречаются чаще всего при эксплуатации кондиционеров ТМ Мидеа, однако существуют и иные, причем у каждой линейки из список разный. Чтобы понимать, что происходит с техникой, нужно открыть инструкцию, где четко прописано какие ошибки могут возникать и что они значат.

Что делать и как устранить ошибки в кондиционерах Midea?

Устранение ошибок кондиционеров – занятие для профессионалов, однако часто их можно урегулировать и самостоятельно. Так, самыми распространенными неисправностями являются:

  • Крайне слабое охлаждение помещения – ниже заявленного. При данной проблеме ошибка не будет появляться несколько дней, а иногда и месяцев. Указывает на утечку хладагента или потерю в производительности компрессора или испарителя. В этом случае нужно вызывать мастеров для решения проблемы и никак иначе.
  • Нарушена связь между внутренним и внешним блоком. В 90% случаев – это чисто программный сбой, который решается жесткой перезагрузкой кондиционера – то есть вынимается вилка из розетки, ожидается 2-3 минуты и снова включается в сеть. При повторном возникновении ошибки за короткий промежуток времени стоит обратиться в СЦ за помощью.
  • Не охлаждает воздух. Изначально нужно посмотреть на пульт ДУ, где выбран режим. В автоматическом режиме кондиционер сам регулирует цикл обдув-кондиционирования, также стоит помнить о том, что многие кондиционеры эффективны через 2-7 минут после включения, так как изначально запускается работа всей системы. Проблемы с охлаждением воздуха могут возникнуть банально от пыли, которая скапливается на фильтрах. При их загрязнении уже на 30% потеря охлаждающей мощности составляет 50%. Для решения нужно просто вымыть и просушить фильтры, а делать это рекомендуется каждые 2-3 дня активного пользования устройством.

При появлении иных проблем стоит не надеяться на удачу – рекомендовано сразу же обращаться в СЦ.

Все современные сплит-системы снабжены функцией самодиагностики, которая выводит на дисплей буквенно-цифровое обозначение «ошибки». Эта функция предназначена для облегчения диагностики и выявления причины неисправности кондиционера, но довольно часто расшифровка кодов ошибок кондиционеров либо не представляется возможной, либо не соответствует причине поломки. Дело в том, что при всем многообразии брендов кондиционеров представленных на нашем рынке, заводов-производителей можно посчитать по пальцам. На одном заводе может производиться до пятидесяти различных брендов. Но и это еще не все – многие бренды постоянно меняют заводы-изготовители, либо заказывают разные модели на разных заводах. К примеру, надо найти расшифровку кода ошибки кондиционера Electrolux, казалось бы нашел табличку в интернете и все. Но не все так просто. Серии Orlando и Evolution произведены на заводе Hisense, соответственно и коды ошибок надо смотреть завода  Hisense. А серии Fusion Evo и Atrium на заводе Midea. Серии Fusion и Monaco на заводе Gree. И заметьте, это все кондиционеры бренда Electrolux.

Коды ошибок завода Midea-MDV:

Кассетные сплит-системы

Инверторные настенные сплит-системы

ON/OF настенные сплит-системы

Коды ошибок завода GREE:

C5

Внутренний блок

отсутствует конфигурационная перемычка на внутренней панели управления

LP

Несоответствие внутреннего и наружного блоков

Несоответствие внутреннего и наружного блоков

E5

Защита по току

Несоответствие напряжения, большой ток, повышенное или пониженное напряжение

Е6

Ошибка связи

Проверьте правильность межблочных соединений

F1

Датчик комнатной температуры воздуха

Датчик вышел из строя, плохой контакт, обрыв, короткое замыкание датчика

F2

Датчик теплообменника (змеевика) внутреннего блока

Датчик вышел из строя, плохой контакт, обрыв, короткое замыкание датчика

F3

Датчик наружного воздуха

Датчик вышел из строя, плохой контакт, обрыв, короткое замыкание датчика

F4

Датчик теплообменника (змеевика) наружного блока

Датчик вышел из строя, плохой контакт, обрыв, короткое замыкание датчика

F5

Датчик температуры компрессора

Датчик вышел из строя, плохой контакт, обрыв, короткое замыкание датчика. Перегрев компрессора

Н3

Перегрузка компрессора

Низкое давление фреона, засорение капиллярной трубки, неисправен компрессор

Н5

Защита модуля IPM

IPM перегрев модуля, высокая температура внутри наружного блока, низкое напряжение, плохой контакт

Н6

Вентилятор внутреннего блока

Вентилятор не работает, низкая скорость вентилятора

Н7

Рас синхронизация компрессора

Высокое давление фреона, низкое напряжение, плохой контакт

U7

4-х ходовой клапан

Неисправен клапан, неисправен соленоид, плохой контакт

Мы собрали для вас все самые распространённые ошибки кондиционеров Midea и добавили информацию о том, что означают эти ошибки и как их можно исправить. Это поможет вам понять почему кондиционер Midea (Мидеа) выдает такую ошибку и что с этим можно сделать.

Коды ошибок кондиционеров Midea

Модели Midea серии MSE (18, 12, 09, 07)

Неисправность Лампочка Лампочка таймера
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Не светится Мигает
более чем минуты не работает вентилятор внутреннего блока, Мигает Не светится
Не исправен комнатный или трубный термистор внутреннего блока Мигает Горит постоянно
Ошибка платы EEROM Горит постоянно Мигает
Перепутаны фаза и нейтрально Мигает Мигает

Модели 24 и 28 Midea серии MSE

Описание неисправности Operation lamp Timer lamp Defrosting lamp Auto lamp
Уже 4 раза сработала тепловая защита компрессора и др. защита от перегрузки. Мигает Мигает Мигает Мигает
Не исправен датчик температуры внутреннего блока Не горит Мигает Не светится Не горит
Не исправен трубный датчик температуры внутреннего блока Мигает Не горит Не светится Не горит
Не исправен температурный зонд наружного блока Не горит Не светится Мигает Не горит
Отработала защита наружного блока (для 380В) или не исправен термистор наружного блока. Не горит Не горит Мигает Мигает
Перепутаны фаза и нейтрально Мигает Мигает Не светится Не горит
Ошибка платы EEROM Не горит Мигает Не светится Мигает
Обрыв межблочного кабеля для моделей на 380В Не горит Не горит Не светится Мигает

Коды ошибок Midea Модели MSE inverter

Код ошибки Тип ошибки Решение
Е0 Ошибка/неисправен EEPROM заменить плату внутреннего блока
Е1 Неправильное межблочное соединение не гарантия, возможно выгорели элементы на платах внутреннего и наружного блоков
Е2 Неправильное подключение ноль-фаза правильно подключить ноль и фазу
Е3 Неисправен мотор вентилятора внутреннего блока заменить мотор
Е4 Резервная *
Е5 Неисправны/обрыв/нет контакта термистора наружного блока проверка контактов, замена термистора
Е6 Неисправны/обрыв/нет контакта термисторы внутреннего блока проверка контактов, замена термисторов
Р0 Перегрузка по току/неисправен модуль IPM очистка теплообменников, не правильное кол-во хладагента в системе, замена модуля, проверить обмотки компрессора
Р1 Слишком высокое или слишком низкое напряжение питания не гарантия
Р2 Высокая температура нагнетания не гарантия, загрязнение теплообменников, недостаток хладагента, воздух в системе
Р3 Слишком низкая уличная температура не гарантия, отключение при -15С, включение при -12С
Р4 Неисправность компрессора проверить сопротивление обмоток компрессора

Коды ошибок сплит-систем Midea Модели 07,09,12,18 серии MSG

Описание неисправности Operation lamp Timer lamp Defrosting lamp
4 раза отработала защита компрессора по перегрузке Мигает не светится Мигает
Более минуты не включается вентилятор внутреннего блока,. не светится Мигает Мигает
Нет запускается компрессор Мигает Мигает Мигает
Не исправен трубный термистор на внутреннем блоке не светится не светится Мигает
Не исправен комнатный термистор на внутреннем блоке не светится Мигает не светится
Ошибка (сбой)EEROM Горит постоянно Мигает не светится

Коды ошибок сплит-систем Midea Модель 24 серии MSG

Мигает — Operation, Timer, Defrosting, Auto Сработало 4 раза защита компрессора по перегрузке
Мигает — Timer Не работает комнатный термистор на внутреннем блоке
Мигает — Operation Не работает трубный термистор на внутреннем блоке
Мигает — Defrosting Не работает термистор на наружном блоке
Мигает — Defrosting, Auto Сработала защита наружного блока (для 380В) или не работает термистор наружного блока
Мигает — Auto, Ошибка платы EEROM

Коды ошибок MSG-30_36HR

Индикация внутреннего блока  
Индикация светодиодов  
мигают светодиоды Operation, Timer, Defrosting Четырежды за час был превышен рабочий ток.
мигает светодиод Timer Обрыв или замыкание комнатного термистора
мигает светодиод Operation Обрыв или замыкание трубного термистора
Светодиод Defrosting мигает с частотой 5 Гц Обрыв или замыкание термистора наружного. блока
мигают светодиоды Operation, Timer, Ошибка EEPROM
мигают светодиоды Defrosting, AUTO, Ошибка наружного блока
мигает светодиод AUTO Ошибка межблочной связи
   
   
Индикация наружного блока  
Индикация светодиодов (кол-во вспышек через 2-х секундный интервал)  
5 вспышек Ошибка межблочного соединения
4 вспышки Неверная фазировка(3-х фазная модель)
3 вспышки Высокое давление
2 вспышки Оборван или замыкает термистор
1 вспышки Неисправность внутреннего блока
Горит постоянно Нормальная работа

Коды ошибок Midea MSX 07-18

Midea Коды ошибок серия MSX модели 07-18
E1 сбой EEPROM
E2 Нейтраль пробивает на землю
Е3 Ошибка управления скоростью вращения электродвигателя внутр. Блока (не опрашивается датчик Холла)
Е4 Превышение пускового тока компрессора при запуске 4 раза подряд
Е5 Ошибка по термистору воздуха внутреннего блока
Е6 Ошибка по трубному температурному датчику внутреннего блока

Коды ошибок Midea MSX 21-24

Midea Коды ошибок серия MSX модели 21-24
E1 сбой EEPROM
E4 Перегрузка по току компрессора четырежды в течение часа.
Е5 Ошибка по температурному зонду внутреннего блока по воздуху
Е6 Ошибка по трубному температурному зонду внутреннего блока
Е7 Ошибка по трубному температурному зонду внешнего блока
Е8 Перепутаны ноль и фаза
Е9 Неверное подсоединение внутреннего и внешнего блока (неверная коммуникация)

error code of unitary Midea

Самодиагностика   
Внутренний блок      
тип содержание индикация примечание
1 защита Четырежды сработала перегрузка компрессора по току мигают LED operation+timer+defrosting кондиционер не включается. Ошибка сбрасывается после полного отключения от электросети
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer
Наружный блок      
модели трехфазные 36, 48, 60 kBTU, наружный блок универсального типа  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка Низкое давление кипения мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внешнего блока MDV

Код ошибки Описание
Е1 Ошибка по фазному монитору (перепутаны фазы, отсутствие одной из фаз)
Е2 Нарушение межблочной связи внутренникнаружник
Е3 Не работаетнет контакта с датчиком температуры Т3
Е4 Не работаетнет контакта с датчиком температуры Т4
Е5 Не работаетнет контакта с датчиком температуры Т5
Е6 Превышение уровня воды в поддоне кассетного внутренника
Е7 Не работаетнет контакта с датчиком температуры Т6
Е8 Неправильный адрес наружнего блока
Р1 Защита по высокому давлению
Р2 Защита по низкому давлению
Р3 Токовая защита компрессора
Р4 Защита по высокой температуре нагнетания
Р5 Превышение температуры конденсации

Коды ошибок внешних блоков для все моделей полупрома

Наружный блок        
модели трехфазные 36, 48, 60 kBTU, универсальный наружный блок  
тип содержание LED1 LED2 LED3
ОК работа светится выкл выкл
ошибка неправильное чередование фаз мигает выкл выкл
ошибка нет одной или двух фаз, перекос по фазам А и В мигает выкл выкл
ошибка нет фазы С, перекос по фазе С выкл выкл выкл
ошибка защита по низкому давлению мигает мигает выкл
ошибка перегрузка по току выкл выкл мигает
ошибка термистор трубный наружного блока (T3) выкл мигает мигает
ошибка термистор наружного блока по воздуху (T4) выкл мигает выкл
ОК ожидание мигает(медленно) мигает(медленно) мигает(медленно)

Коды ошибок внутреннего блока серий MCC & MUC

Коды ошибок внутреннего блока серии МСС(МUC)
Индицируются на дисплее
Код Тип ошибки Действия
Е2 нет контакта/не исправен термистор по воздуху проверить контакт/заменить термистор по воздуху
Е3 нет контакта/не исправен термистор испарителя проверить контакт/заменить термистора испарителя
Е4* нет контакта/не исправен термистор конденсатора проверить контакт/заменить термистора конденсатора
Е5*** нет контакта/неисправен датчик уровня конденсата в поддоне проверить контакт/заменить датчик
Е6** ошибка/неисправность наружного блока смотреть ошибки на плате наружного блока
Е7 ошибка EEPROM внутреннего блока заменить/перепрограммировать EEPROM внутреннего блока
Е8*** переполнение поддона конденсатом проверить дренажную систему и работу помпы
* — только однофазные модели!
** — только трехфазные модели
*** — MCC

Коды ошибок внутренних блоков серий MUA & MCA

Самодиагностика      
Внутренний блок      
тип содержание индикация примечание
1 защита перегрузка по току, 4 раза за 1 час мигают LED operation+timer+defrosting кондиционер не работает, сброс ошибки отключением электропитания
2 защита защиты наружного блока мигают все LED автоматически сбрасывается по устранению ошибки, кроме термистора трубного наружного блока
3 ошибка термистор по воздуху внутреннего блока мигает timer
4 ошибка термистор трубный внутреннего блока мигает operation
5 ошибка термистор трубный наружного блока мигает defrosting
6 ошибка термозащита мигают operation+timer

Коды ошибок мобильного к-ра серии EACM

Коды ошибок мобильного кондиционера М-серии
Индицируются на дисплее
Код Тип ошибки Действия
Р1 переполнение по уровню 1(верхний поддон) слить конденсат через верхнюю заглушку
Р2 переполнение по уровню 2(нижний поддон) слить конденсат через нижнюю заглушку
Е1 нет контакта/неисправен термистор Т1 проверить контакт/заменить термистор Т1
Е2 нет контакта/неисправен термистор Т2 проверить контакт/заменить термистор Т2
Е3 нет контакта/неисправен термистор Т3 проверить контакт/заменить термистор Т3

Мы не рекомендуем проводить ремонтные работы самостоятельно, лучше довериться специалистам нашей компании, которые в кратчайшие сроки устранят неисправность, продлят жизнь вашей технике, дадут гарантию на выполненную работу и при этом, вы не будите рисковать тем, что можете поломать дорогостоящее оборудование или случайно допустить утечку хладагента.

 Почему выгодно обращаться в компанию Климатхол: 

  • У нас всегда качественное обслуживание;
  • Мы всегда устанавливаем только оригинальные детали;
  • Мы проводим работы в удобное для вас время;
  • Мы даем гарантию на все услуги;
  • У нас очень приятные цены;
  • Мы сможем быстро и качественно устранить любую поломку;
  • Все наши мастера имеют опыт работы в сфере ремонта и обслуживания кондиционеров более 3 лет;
  • Но главное – вы в кратчайшие сроки получите рабочую технику. 

Услуги нашей компании:

  1. Заправка кондиционеров;
  2. Чистка кондиционеров;
  3. Демонтаж кондиционеров;
  4. Обслуживание кондиционеров;
  5. Подробный прайс на ремонт и обслуживание кондиционеров.

Какая ошибка у вашего кондиционера?

Код ошибки: Е0

Неисправен EEPROM

Плата внутреннего блока неисправна

Код ошибки: E2

Ошибка коммутации внутреннего и внешнего блоков

Неправильное соединение межблочных проводов. Поломка управляющей платы

ТО вентиляци

Код ошибки: E3

Код ошибки: E4

Неисправность датчика температуры наружного воздуха

Датчик неисправен. Ненадежное подключение датчика

Решение не помогло или нужно больше информации?
Проконсультируйтесь со специалистом или вызовите мастера!

Обслуживание вентиляции

Код ошибки: E5

Срабатывание защиты компрессора по напряжению

Напряжение питания компрессора не находится в допустимом диапазоне

Обслуживание вентиляции

Код ошибки: E6

Ошибка модуля PFC (выпрямителя)

Нестабильная работа источников питания. Повреждение модуля PFC

Код ошибки: P0

Перегрев компрессора

Датчик температуры внутри компрессора неисправен. Ненадёжно подключен датчик. Недостаточно хладагента. Перегрев компрессора

Код ошибки: P1

Срабатывание защиты по превышению давления

Неисправность датчика. Превышение допустимого давления

Код ошибки: P2

Срабатывание защиты по понижению давления

Неисправность датчика. Понижение давления ниже допустимого

Обслуживание вентиляции

Код ошибки: P3

Срабатывание защиты компрессора по току

Низкое напряжение в электросети. Плохое соединение контакта компрессора

Код ошибки: P4

Срабатывание защиты по высокой температуре нагнетания газа из компрессора

Высокая температура нагнетания газа из компрессора. Неисправность датчика

Понравилась статья? Поделить с друзьями:
  • Vrv haier коды ошибок
  • Vrv gree коды ошибок
  • Vrv general climate коды ошибок
  • Vrserver exe системная ошибка
  • Vrf система ned коды ошибок