Vsphere ha virtual machine failover failed ошибка

djciaro

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

djciaro

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Possible Reason: The Alarm is stuck. It needs to be reset. It may be a known bug with version ESX 4.0 Update 1.

Fix: Change the Frequency of the Alarm to 1 minute. This resets the alarm. If everything is ok, the alarm will no longer be stuck. Set back to original time. (5 Minutes)

  • Click vCenter
  • Go to the Alarms Tab
  • Go to the Actions Tab
  • Change “Repeat Actions Every: 5 minutes” to 1 minute.
  • Confirm after 5 minutes it is no longer sending out alerts.
  • Change back to 5 minutes.
  • This should resolve the issue

If you found this information useful, please consider awarding points for «Correct» or «Helpful». Thanks!

djciaro

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

View Triggered Alarms and Alarm Definitions

Triggered alarms are visible in several locations throughout the vSphere Client and vSphere Web Client. Alarm definitions are accessible only through the vSphere Client.

Prerequisites

You must have a vSphere Web Client or a vSphere Client connected to a vCenter Server.

Procedure

Perform the following actions for the client you are using:

Option

Description

vSphere Client

To view all triggered alarms, click Alarms in the status bar.

To view alarms triggered on an selected inventory object, select the Alarms tab > Triggered Alarms.

To view a list of alarms associated with a selected inventory object, select the Alarms tab > Definitions. The Defined In column indicates the object on which the alarm was set.

vSphere Web Client

To view all triggered alarms, click All in the Alarms sidebar.

To view only newly triggered alarms, click New in the Alarms sidebar.

To view acknowledged alarms, click Ack’d in the Alarms sidebar.

To view alarms triggered on an selected inventory object, select Monitor > Alarms tab.

http://pubs.vmware.com/vsphere-50/index.jsp?topic=/com.vmware.vsphere.install.doc_50/GUID-48AC6D6A-B…

If you found this information useful, please consider awarding points for «Correct» or «Helpful». Thanks!

tdubb123

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

oregonpcs

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

I am also unable to modify the Alarm Frequency, as it is greyed out.  Disabling and re-enabling the «vSphere HA virtual machine failover failed» alarm fixed the problem for me.

At the vCenter level select the Alarms tab, Edit the settings of the alarm, select the General tab, disabled/re-enable the alarm.

Larry2148

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Do you see the VC as the «defined in» value for this alarm?  If it’s defined for a datacenter or something like that you would experience this behavior.

«Alarm settings are read only except when accessed through the object where they were defined.»

Check it out and let us know, also a screenshot of the alarms/alarm settings page may be of value.

Regards,

Larry

pkuzma82

  • Mark as New
  • Bookmark
  • Subscribe
  • Mute
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

I went to edit and it was greyed out.  I noticed that it said «changing these options will clear current trigger list» on the General Tab.  I unchecked Enable, clicked ok, then went back and enabled it.  Seems fine.

I am getting these warnings as well every time I restart my vSphere server. Resetting them every time is easy — but why?! Any correct solution instead of this work around??

Версия 7.0U1 vSAN стала доступна с 6 октября 2020 года. Многим удалось уже протестировать ее на практике, кто-то – в самом разгаре подготовки к апгрейду этого замечательного решения для хранения данных, а другие еще только находятся в процессе знакомства с ним. И, без сомнения, всем им будет полезен материал о траблшутинге VMware vSAN 7.0U1.

Несмотря на то, что вендор, без преувеличения, относится к этому продукту с особым трепетом и старается всеми силами сделать его идеальным, ошибок в нем еще встречается немало, как и проблем с внедрением и применением. Что ж, сегодня мы постараемся всех их перечислить, и, по возможности, предложить действенные пути решения.

  • Issue: vSAN идет вразрез с принципами HA vSphere, позволяя пользователям разворачивать виртуальные машины одновременно и на локальном, и на удаленном хранилище данных. Например, можно развернуть один VMDK на локальном хранилище vSAN, и один – на удаленном.

Resolve: Не позволять пользователям разворачивать диски в разных по типу расположения местах.

  • Issue: Сводная информация о хранилище хоста не включает в себя хранилища данных vSAN. Если зайти на станицу «Summary» ESXi-хоста, «Storage summary» по свободным, использованным значениям и значениям емкости не включает доступные с этого хоста хранилища vSAN.

Resolve: Информацию о хранилище vSAN можно посмотреть в «Summary» кластера.

  • Issue: Задача переформатирования объекта зависла и не прогрессирует. При переформатировании объектов vSAN переконфигурирует их формат в фоновом режиме. Перенастраиваются такие объекты целыми партиями, и процесс зависит от доступной для кластера транзитной емкости. Когда емкость задач выходит за свой лимит, vSAN ждет ее очистки перед продолжением переформатирования.

Resolve: нет. На самом деле задача выполнится, просто – в свое время.

  • Issue: Системные виртуальные машины не выключаются. vSphere Cluster Services (vCLS) в апдейте 7.0U1 позволяет размещать набор системных машин в кластере vSAN. Пользователям запрещено их отключать, так как это действие может оказать неблагоприятное влияние на ряд описанных здесь рабочих процессов vSAN.

Resolve: Проблема и работа с ней описаны в материале.

  • Issue: Внутренняя сеть докера vSAN File Services VM (FSVM) может перекрываться пользовательской сетью, не выдавая сообщение о том, что нужна реконфигурация. Вызывает проблемы с маршрутизацией трафика к корректной конечной точке.

Resolve: Указать другую сеть для файловой службы (отличную от 172.17.0.0/16).

  • Issue: Некоторые задачи развертывания файловых служб виртуальной машины (FSVM) могут фейлиться во время включения дедупликации или шифрования/компрессии на кластере, где доступна vSAN File Service. Указанные процессы вызывают Disk Format Change (DFC), который поочередно отключает FSVM на каждом хосте. В то же время ESX Agent Manager (EAM) пытается развернуть FSVM и тогда получается сбой.

Resolve: Эти сбои можно игнорировать. Когда завершится DFC, исправление FSVM будет успешным.

  • Issue: Deep Rekey может прервать пользовательские процессы ввода/вывода. Речь об операциях NFS- и SMB-пользователей.

Resolve: Если это критично, перенести процесс Deep Rekey в окно maintenance.

  • Issue: Файловые службы vSAN не могут быть включены из-за старой версии формата on-disk (древнее 11.0).

Resolve: Обновить версию формата диска.

  • Issue: Удаление файлов не отображается в емкости vSAN. Освобожденные блоки не возвращаются в хранилище vSAN, даже если оттуда удалены все файлы. Они могут повторно использоваться, когда новые данные будут записываться на тот же общий файловый ресурс.

Resolve: Для возвращения этого хранилища в vSAN, следует удалить общие файловые ресурсы.

  • Issue: Исправление задачи кластера большого размера может сбоить из-за проблем с тестированием здоровья сети vSAN. Речь о кластерах с более чем 16-ю хостами и задачах обновления хоста. Тогда пинги не проходят, и обновление хоста в vSphere Life Cycle Manager прерывается.

Resolve: После пре-чека отключить оповещения для следующих тестов vSAN:

    • vSAN: Basic (unicast) connectivity check
    • vSAN: MTU check (ping with large packet size).

Когда обновление завершится, восстановить эти оповещения.

  • Issue: Хост сбоит в сценарии смены диска «на горячую», когда повторно вставляется диск. Когда диск NVMe извлекается таким образом и вставляется менее чем через минуту, хост падает.

Resolve: Подождать более одной минуты.

  • Issue: Update Manager показывает ID теста вместо имени. В процессе использования Update Manager для обновления хостов в vSAN кластере, хелс-чеки vSAN могут выявить проблемы с ним и выдать сообщение, к примеру, вида:

Before host exits MM, remediation failed because vSAN health check failed. vSAN cluster is not healthy because vSAN health check(s): com.vmware.vsan.health.test.controlleronhcl failed

Resolve: Использовать службу проверки здоровья для идентификации и решения проблем. Затем запустить обновление хоста снова. Больше об использовании проверок здоровья vSAN при работе с vSphere Update Manager (VUM) можно почитать здесь.

  • Issue: Невозможно перевести последний хост в кластере в режим обслуживания, удалить диск или дисковую группу. Когда только один хост остался в кластере, а тот ушел на maintenance, операции в режиме «Full data migration» или «Ensure accessibility» могут завершаться ошибкой, не предложив добавить новый ресурс. Аналогичное случается, когда только один диск или дисковая группа остались в кластере, и их нужно удалить.

Resolve: До перевода последней оставшейся в кластере ноды в режим обслуживания с выбранными опциями «Full data migration» и «Ensure accessibility», добавить другой хост такой же конфигурации в кластер. Перед удалением последнего оставшегося диска или дисковой группы, добавить новый диск или группу такой же конфигурации и емкости.

  • Issue: Рабочие процессы реконфигурации объектов могут фейлиться из-за недостатка емкости одного или большего количества дисков (дисковых групп), если они почти заполнены. Ресинхронизация vSAN становится на паузу, если диски в кластерах с дедупликацией или без нее достигают своих настраиваемых пороговых значений заполненности паузы ресинхронизации. Это сделано для того, чтобы избежать переполнения дисков при операциях ввода/вывода ресинхронизации. Останавливаются все рабочие процессы вроде EMM, восстановления, ребаланса и изменения политик.

Resolve: Если в другом месте кластера все еще есть свободное пространство, выполнить повторную ребалансировку для освобождения места другим дискам. Тогда дальше реконфигурация пройдет успешно.

  • Issue: После восстановления из переполненного кластера виртуальные машины могут потерять HA-защиту. Если диски заполнены на 100% на хостах кластера vSAN, на ВМ подвисает вопрос и, следовательно, может утратиться защита НА. Также машины с подвисшим вопросом не защищаются НА после восстановления из полного кластерного сценария.

Resolve: После восстановления в результате полного кластерного сценария vSAN выполнить одно из трех:

    • Выключить и включить НА;
    • Реконфигурировать НА;
    • Выключить и включить виртуальные машины.
  • Issue: Сбой выключения ВМ с «Question Pending». Если у машины есть неразрешенный вопрос, любые связанные с ней операции недоступны, пока на него не будет дан ответ.

Resolve: Освободить дисковое пространство на соответствующем томе, после чего нажать «Retry».

  • Issue: При заполнении кластера IP-адреса ВМ меняются на IPV6 или становятся недоступными. При заполнении кластера vSAN (одна или несколько дисковых групп достигают 100%) задается вопрос к пользователю, требующий определенных его действий в качестве ответа. Если он остается нерешенным или не сделать что-то с заполненностью кластера, IP-адреса виртуальных машин сменятся на IPV6 или станут недоступны. Так было задумано, чтобы предотвратить использование доступа по SSH к ВМ. Консоль, кстати, аналогично недоступна: ввод пароля рута делает консоль пустой.

Resolve: нет.

  • Issue: Не получается удалить группу дисков с включенной дедупликацией после перехода емкости диска в статус PDL. То же самое происходит, если поменять уникальный идентификатор диска, или же при выявлении устройством неустранимой аппаратной ошибки.

Resolve: Каждый раз при удалении или изменении уникального идентификатора диска емкости, либо же при возникновении неисправимой аппаратной ошибки, подождать несколько минут и только затем пробовать удалить группу дисков.

  • Issue: Состояние vSAN показывает недоступность, связанную с несоответствием при проваленном запросе политики. Это часто случается, когда есть другая запланированная по графику работа, использующая запрошенные ресурсы. По мере того, как ресурсы высвобождаются, vSAN автоматически перестраивает график исполнения запроса этой политики.

Resolve: Как правило, сканирование периода в vSAN устраняет эту проблему автоматически. Однако стоит учитывать, что прочие незавершенные действия могут нуждаться в доступных ресурсах даже после того, как политика была изменена, однако еще не успела примениться. В этом случае рекомендуется добавить емкость (если в отчете о емкости значения слишком высоки).

  • Issue: В кластерах с дедупликацией возвратная ребалансировка может не состояться, если диск показывает более 80% заполненности. Это случается потому, что в таких кластерах все, ожидающее записей или удалений, аналогично учитывается при калькуляции свободной емкости.

Resolve: нет.

  • Issue: Из гостевой ОС команды TRIM/UNMAP не работают. Если гостевая операционная система пытается восстановить пространство при онлайн-консолидации во время снэпшота, введение команд TRIM/UNMAP завершается ошибкой. В результате место не освобождается.

Resolve: Повторить операцию освобождения места после снятия снэпшота. Если и далее TRIM/UNMAP не работают, перемонтировать диск.

  • Issue: Ошибка на хосте при преобразовании хоста данных в хост-свидетель. При превращении кластера vSAN в растянутый кластер, обязательно нужно предоставить ему ноду-свидетеля. Однако в процессе приходится использовать режим maintenance с полной миграцией данных. Если же положить хост в режим обслуживания с опцией «Ensure accessibility» и инициировать конфигурирование ноды-свидетеля, хост падает в «экран смерти».

Resolve: Удалить группу дисков на хосте-свидетеле, а затем заново их создать.

  • Issue: Виртуальная машина дублируется с таким же именем в vCenter Server, когда постоянный хост падает в процессе миграции хранилища данных. Если ВМ передает сторадж vMotion из vSAN на другое хранилище данных, к примеру, на NFS, и регистрируется падение хоста в сети vSAN (вызывая аварийное переключение НА на машине), она может продублироваться на vCenter Server.

Resolve: Выключить невалидную виртуальную машину и снять ее регистрацию в vCenter Server.

  • Issue: Реконфигурация существующего растянутого кластера под новый vCenter Server вынуждает vSAN выдавать ошибку при проверке состояния (статус «красный»), вида:

vSphere cluster members match vSAN cluster members

Resolve: Проделать следующее:

    1. Подключиться по SSH к хосту-свидетелю;
    2. Декомиссовать диски на хосте-свидетеле, используя следующую команду:

esxcli vsan storage remove -s «SSD UUID»

    1. Удалить хост-свидетель из кластера по силовому сценарию, командой:

esxcli vsan cluster leave

    1. Реконфигурировать растянутый кластер из нового vCenter Server, пройдя по пути: «Configure > vSAN > Fault Domains & Stretched Cluster».
  • Issue: Не удается обновить формат диска во время ресинхронизации vSAN больших объектов. Ошибка вида:

Failed to convert object(s) on vSAN

Resolve: Дождаться завершения ресинхронизации, после проапгрейдить формат диска. Проверить статус ресинхронизации можно в «Monitor > vSAN > Resyncing Components».

  • Issue: Последовательная проверка состояния кластера завершается ошибкой во время операции «deep rekey», вида:

Cluster configuration consistency

Эта операция на зашифрованном vSAN-кластере может занять несколько часов. А традиционный хелс-чек не распознает ее, и поэтому выдает ошибку.

Resolve: Провести повторный тест после «deep rekey».

  • Issue: Утеря конфигурации растянутого кластера vSAN после выключения vSAN на кластере. Пропадает конфигурация всего: и растянутого кластера, и хоста-свидетеля, и fault domain.

Resolve: Реконфигурировать растянутый кластер после включения.

  • Issue: Выключенная ВМ показывается как недоступная при замене хоста-свидетеля. Такое отображается только краткий промежуток времени, а после завершения процесса вновь все проявляются. С запущенными все нормально.

Resolve: нет. Рабочему процессу не вредит.

  • Issue: Не получается перевести хосты с неисправным загрузочным носителем в режим обслуживания. vSAN не может сохранить изменения в конфигурации, поэтому выдает ошибку. В логах пишется:

Lost Connectivity to the device xxx backing the boot filesystem

Resolve: Вручную переместить дисковые группы с каждого хоста, используя опцию «Full data evacuation». После положить хост в maintenance mode.

  • Issue: Служба проверки состояния не работает, если в кластере vSAN есть ESXi-хосты с vSphere 6.0 Update 1 или старше. vSAN 6.6 и свежее не работает с такими версиями.

Resolve: Не добавлять хосты с такой версией среды или обновить хосты до более поздней версии.

  • Issue: После аварийного переключения растянутого кластера виртуальные машины на основном сайте регистрируют ошибку:

Failed to failover

Если второй сайт в растянутом кластере падает, ВМ должны аварийно переключаться на основной.

Resolve: нет. Игнорировать. Не влияет на успешность аварийного переключения.

  • Issue: Во время создания партиций сети компоненты на активном сайте кажутся отсутствующими. В процессе деления сети в хосте vSAN или растянутом кластере в веб-клиенте vSphere отображается кластер с точки зрения неактивного сайта.

Resolve: Использовать RVC-команды, чтобы проявить реальное состояние объектов (например, «vsan.vm_object_info»).

  • Issue: Некоторые объекты не отвечают требованиям после принудительного восстановления. Это случается потому, что в процессе собственник таких объектов был перемещен на другую ноду. Силовой метод восстановления для таких объектов может примениться с задержкой.

Resolve: Выполнить принудительное восстановление после того, как все прочие объекты будут восстановлены и ресинхронизированы. Подождать, пока vSAN не доделает до конца эту работу.

  • Issue: При перемещении узла из одного зашифрованного кластера в другой, а затем назад, задача не выполняется. Ошибка вида:

A general system error occurred: Invalid fault

Так получается потому, что vSAN не в состоянии повторно зашифровать данные на узле, так как пытается использовать исходный ключ шифрования. Спустя немного времени исходный ключ на хосте восстанавливается, после чего все отключенные диски в кластере монтируются.

Resolve: Перезагрузить хост и подождать, пока все диски не смонтируются.

  • Issue: Появляется дисбаланс растянутого кластера после восстановления сайта. Иногда при восстановлении сайта на растянутом кластере хосты с упавшего сайта возвращаются последовательно в течение долгого периода времени. vSAN может чрезмерно использовать некоторые хосты при восстановлении их утерянных компонентов.

Resolve: Восстановить все хосты на отказавшем сайте вместе в свободном от операций окне.

  • Issue: Сбой операций ВМ из-за проблем с НА на растянутом кластере. В некоторых сценариях сбоя в растянутых кластерах затрагиваются определенные операции виртуальных машин (vMotion или включение машины). Такие сценарии могут включать частичное или полное падение сайта, отказ высокоскоростной связи между сайтами. Это возникает по причине зависимости от доступности VMware HA для нормальной работы сайтов растянутых кластеров.

Resolve: Отключить vSphere HA до выполнения vMotion, создания виртуальных машин или их включения. Затем обратно включить.

  • Issue: Невозможно выполнить deep rekey отключенной дисковой группы. Дело в том, что перед deep rekey vSAN делает shallow rekey. А последний не умеет работать с демонтированными дисковыми группами. Соответственно, и deep rekey не стартует.

Resolve: Перемонтировать или удалить отключенную дисковую группу.

  • Issue: Логи свидетельствуют, что конфигурация брандмауэра изменилась. Появляется новый вход брандмауэра в профиле безопасности при включенном шифровании vSAN («vsanEncryption»). Это правило контролирует, как хосты связываются напрямую с KMS. Когда такое случается в логи («/var/log/vobd.log») записывается следующее сообщение:

Firewall configuration has changed. Operation ‘addIP4’ for rule set vsanEncryption succeeded.
Firewall configuration has changed. Operation ‘removeIP4’ for rule set vsanEncryption succeeded.

Resolve: нет. Можно игнорировать.

  • Issue: Отказ НА не случается после установки параметра «Traffic Type» на vmknic с целью поддержки трафика свидетеля.

Resolve: Вручную отключить vSphere HA на кластере, а затем снова включить.

  • Issue: Не поддерживается iSCSI MCS. Целевая служба vSAN iSCSI не поддерживает Multiple Connections per Session (MCS).

Resolve: нет.

  • Issue: Любой инициатор iSCSI может обнаруживать цели iSCSI.

Resolve: Можно заизолировать свои ESXi-хосты от инициаторов iSCSI путем помещения их в отдельную VLAN.

  • Issue: После создания сетевого раздела, некоторые операции ВМ на связанных клонах могут фейлиться. Речь об операциях, которые не производят I/O. А именно: снятии снэпшотов и приостановке виртуальных машин. Это случается, когда сетевой раздел уже готов, а пространство имен родительской машины еще недоступно. Когда же оно станет доступным, НА не считает нужным включать такую ВМ.

Resolve: Выключить и снова включить ВМ, которые неактивно используют операции ввода/вывода.

  • Issue: Нельзя перевести узел-свидетель в Maintenance Mode. Ошибка вида:

A specified parameter was not correct

Resolve: При инициации режима обслуживания для хоста-свидетеля выбрать опцию «No data migration».

  • Issue: Перемещение хоста-свидетеля в растянутый кластер и из него оставляет кластер в неправильно сконфигурированном состоянии.

Resolve: Переместить witness-хост вовне растянутого кластера vSAN и переконфигурировать растянутый кластер. Подробнее почитать можно здесь.

  • Issue: Когда сетевая партиция появляется в кластере с НА heartbeat хранилищем данных, виртуальные машины не рестартуют на другом сайте данных. Если в vSAN-кластере для основного или вторичного сайта падает сетевое подключение к другим сайтам, работающие на них машины теряют сеть, но не перезапускаются на другом сайте. Ошибка вида:

vSphere HA virtual machine HA failover failed

Resolve: Когда конфигурируется vSphere HA на кластере, не выбирать НА heartbeat хранилище данных.

  • Issue: Отключенные диски и дисковые группы vSAN отображаются как подключенные в поле «Client Operational Status» веб-клиента vSphere. Если диски или дисковые группы отключены командой:

esxcli vsan storage disk group unmount 

или службой vSAN Device Monitor после демонстрации ими постоянных высоких задержек, веб-клиент vSphere некорректно показывает их статус («mounted»).

Resolve: Использовать поле «Health» для проверки статуса дисков вместо поля «Client Operational Status».

Если найдем еще какие-то интересные проблемы с vSAN 7.0U1, обязательно обновим этот материал. Как и в том случае, когда поймем, как решить задачи, на которые выше не было дано ответа.

Hi,

I’ve updated all my vmWare 5.5 hosts and now most of my virtual servers are displaying ‘vSphere HA virtual machine failover failed’ errors … Dis- and enabling the HA option in the properties of the cluster do not make this go away, nor does ‘reconfigure for vSphere HA’

VMware

Experts Exchange is like having an extremely knowledgeable team sitting and waiting for your call. Couldn’t do my job half as well as I do without it!

Unlimited question asking, solutions, articles and more.

Experts Exchange has (a) saved my job multiple times, (b) saved me hours, days, and even weeks of work, and often (c) makes me look like a superhero! This place is MAGIC!

Walt Forbes

Not exactly the question you had in mind?

Sign up for an EE membership and get your own personalized solution. With an EE membership, you can ask unlimited troubleshooting, research, or opinion questions.

ask a question

Unlimited question asking, solutions, articles and more.

I started with Experts Exchange in 2004 and it’s been a mainstay of my professional computing life since. It helped me launch a career as a programmer / Oracle data analyst

William Peck

Unlimited question asking, solutions, articles and more.

Обновлено 01.04.2019

Ошибка vsphere ha virtual machine monitoring error

Ошибка vsphere ha virtual machine monitoring error

Всем привет сегодня расскажу, как решается и из-за чего выскакивает ошибка vsphere ha virtual machine monitoring error и vsphere ha virtual machine monitoring action. Данная ошибка вполне может перезагрузить виртуальную машину, нештатно завершив все рабочие процессы, ладно если это случиться в вечернее время, с минимальными последствиями для клиентов, а если в самый час пик, это очень сильно ударит по репутации компании и может повлечь денежные убытки.

Вот более наглядное представление этих ошибок в VMware vCenter 5.5.

Ошибка vsphere ha virtual machine monitoring error

Ошибка vsphere ha virtual machine monitoring error-02

Видим сначала идет предупреждение и потом alert

vsphere ha virtual machine monitoring error

vsphere ha virtual machine monitoring action

Анализ log файла

Сначала нужно проанализировать лог файл виртуальной машины, для этого щелкаем правым кликом по datastore и выбираем browse datastore

browse datastore vmware

browse datastore vmware

Переходим в нужную папку виртуальной машины и находим там файл vmware.log

ищем vmware.log

ищем vmware.log

Этот файл vmware.log, нам нужно скачать, сделать это можно к сожалению только на выключенной виртуальной машине, щелкаем по нему правым кликом и выбираем Download

скачиваем лог файл

скачиваем лог файл

Указываем место куда нужно закачать ваш файл, для дальнейшего изучения. Все ошибки в данном файле в большинстве случаев сводятся к необходимости обновить vmware tools

сохранение vmware.log

сохранение vmware.log

То же самое вы можете увидеть и на Vmware ESXI 6.5. (VMware Tools is not installed on this virtual machine)

vsphere ha virtual machine monitoring error esxi 6.5

Обновление vmware tools

Напомню vmware tools это пакет драйверов который устанавливается внутри виртуальной машины для лучшей интеграции и расширения функционала. Как обновить vmware tools в VMware ESXI 5.5 я рассказывал ранее. Еще отмечу, что вначале вам придется удалить Vmware Tools из гостевой операционной системы, так как смонтировать диск с дистрибутивом для обновления вы не сможете, так как поле будет не активно.

ошибка vmware tools

Так же если вы будите медлить с решением данной проблемы, вы будите постоянно ловить синий экран с кодом 0x00000050. При его анализе он будет ругаться на драйвера.

0x00000050

Надеюсь что вы теперь поняли из за чего происходит alert vsphere ha virtual machine monitoring error. Материал сайта pyatilistnik.org

check
Best Answer

  • Are the hosts they are attached to in inventory? If so, try connecting to the host UI and removing them from there. If that doesn’t work either, try disabling DRS on the cluster and see if you are then able to remove them.


    1 found this helpful
    thumb_up
    thumb_down

  • View Best Answer in replies below

    9 Replies

    • Author Rod McGarrigle

      pure capsaicin

      VMware Expert

      • check
        365
        Best Answers
      • thumb_up
        1028
        Helpful Votes

      The VMs are inaccessible, typically because the network drive they are on is no longer available.

      Rebooting the VCSA will recreate these, but I’d also check your network storage since this is where they get created (any network LUN), if they are showing inaccessible, the storage they existed on isn’t available. 


      Was this post helpful?
      thumb_up
      thumb_down

    • Rebooting the vCSA did not affect the issue. The 2 vCLS VMs still appear as inaccessible. All storage volumes are accessible.


      Was this post helpful?
      thumb_up
      thumb_down

    • Remove them from inventory.


      Was this post helpful?
      thumb_up
      thumb_down

    • Remove them from inventory.

      That is also grayed out on them.


      Was this post helpful?
      thumb_up
      thumb_down

    • Are the hosts they are attached to in inventory? If so, try connecting to the host UI and removing them from there. If that doesn’t work either, try disabling DRS on the cluster and see if you are then able to remove them.


      1 found this helpful
      thumb_up
      thumb_down

    • JeffNew1213 wrote:

      Are the hosts they are attached to in inventory? If so, try connecting to the host UI and removing them from there. If that doesn’t work either, try disabling DRS on the cluster and see if you are then able to remove them.

      I unregistered them from the host and they are now listed as Orphaned and remove from inventory is still grayed out. DRS is disabled because I only have Essentials Plus licensing which doesn’t include DRS.


      Was this post helpful?
      thumb_up
      thumb_down

    • I think a reboot of vCenter at this point might fix the issue.


      1 found this helpful
      thumb_up
      thumb_down

    • Author Rod McGarrigle

      pure capsaicin

      VMware Expert

      • check
        365
        Best Answers
      • thumb_up
        1028
        Helpful Votes

      To be clear, I never said rebooting VCSA would remove your broken ones, I said it would recreate them. (The vCLS VMs)

      Your invalid ones are as such because the underlying storage they are on it not accessible.

      You need to fix that or remove them using a direct connection to the host over SSH/CLI


      Was this post helpful?
      thumb_up
      thumb_down

    • After unregistering them directly on the host then rebooting vCSA the VMs are now gone. Thanks JeffNew1213​!


      Was this post helpful?
      thumb_up
      thumb_down

    I received two questions this week around partition scenarios where after the failure has been lifted some VMs display the error message “vSphere HA virtual machine failed to failover”. The question that then arises is: why did HA try to restart it, and why did it fail? Well, first of all, this is an error that in most cases you can safely ignore. There’s a KB on the topic which gives a bit of detail to be found here, but let me explain also in a bit more depth.

    In a partitioning scenario, each partition will have its own primary node. If there is no form of communication (datastore/network) possible, what the HA primary will do is it will list all the VMs that are currently not running within that partition. It will also want to try to restart those VMs. A partition is extremely uncommon in normal environments but may happen in a stretched cluster. In a stretched cluster when a partition happens a datastore only belongs to 1 location. The VMs which appear to be missing typically are running in the other location, as typically the other location will have access to that particular datastore. Although the primary has listed these VMs as “missing and need to restart” it will not be able to do this. Why? It doesn’t have access to the datastore itself, or when it has access to the datastore the files are locked as the VMs are still running. As a result, this will, unfortunately, be reported as a failed failover. Even though the VM was still running and there was no need for a failover. So if you hit this during certain failure scenarios, and the VMs were running as you expected, you can safely ignore this error.

    Версия 7.0U1 vSAN стала доступна с 6 октября 2020 года. Многим удалось уже протестировать ее на практике, кто-то – в самом разгаре подготовки к апгрейду этого замечательного решения для хранения данных, а другие еще только находятся в процессе знакомства с ним. И, без сомнения, всем им будет полезен материал о траблшутинге VMware vSAN 7.0U1.

    Несмотря на то, что вендор, без преувеличения, относится к этому продукту с особым трепетом и старается всеми силами сделать его идеальным, ошибок в нем еще встречается немало, как и проблем с внедрением и применением. Что ж, сегодня мы постараемся всех их перечислить, и, по возможности, предложить действенные пути решения.

    • Issue: vSAN идет вразрез с принципами HA vSphere, позволяя пользователям разворачивать виртуальные машины одновременно и на локальном, и на удаленном хранилище данных. Например, можно развернуть один VMDK на локальном хранилище vSAN, и один – на удаленном.

    Resolve: Не позволять пользователям разворачивать диски в разных по типу расположения местах.

    • Issue: Сводная информация о хранилище хоста не включает в себя хранилища данных vSAN. Если зайти на станицу «Summary» ESXi-хоста, «Storage summary» по свободным, использованным значениям и значениям емкости не включает доступные с этого хоста хранилища vSAN.

    Resolve: Информацию о хранилище vSAN можно посмотреть в «Summary» кластера.

    • Issue: Задача переформатирования объекта зависла и не прогрессирует. При переформатировании объектов vSAN переконфигурирует их формат в фоновом режиме. Перенастраиваются такие объекты целыми партиями, и процесс зависит от доступной для кластера транзитной емкости. Когда емкость задач выходит за свой лимит, vSAN ждет ее очистки перед продолжением переформатирования.

    Resolve: нет. На самом деле задача выполнится, просто – в свое время.

    • Issue: Системные виртуальные машины не выключаются. vSphere Cluster Services (vCLS) в апдейте 7.0U1 позволяет размещать набор системных машин в кластере vSAN. Пользователям запрещено их отключать, так как это действие может оказать неблагоприятное влияние на ряд описанных здесь рабочих процессов vSAN.

    Resolve: Проблема и работа с ней описаны в материале.

    • Issue: Внутренняя сеть докера vSAN File Services VM (FSVM) может перекрываться пользовательской сетью, не выдавая сообщение о том, что нужна реконфигурация. Вызывает проблемы с маршрутизацией трафика к корректной конечной точке.

    Resolve: Указать другую сеть для файловой службы (отличную от 172.17.0.0/16).

    • Issue: Некоторые задачи развертывания файловых служб виртуальной машины (FSVM) могут фейлиться во время включения дедупликации или шифрования/компрессии на кластере, где доступна vSAN File Service. Указанные процессы вызывают Disk Format Change (DFC), который поочередно отключает FSVM на каждом хосте. В то же время ESX Agent Manager (EAM) пытается развернуть FSVM и тогда получается сбой.

    Resolve: Эти сбои можно игнорировать. Когда завершится DFC, исправление FSVM будет успешным.

    • Issue: Deep Rekey может прервать пользовательские процессы ввода/вывода. Речь об операциях NFS- и SMB-пользователей.

    Resolve: Если это критично, перенести процесс Deep Rekey в окно maintenance.

    • Issue: Файловые службы vSAN не могут быть включены из-за старой версии формата on-disk (древнее 11.0).

    Resolve: Обновить версию формата диска.

    • Issue: Удаление файлов не отображается в емкости vSAN. Освобожденные блоки не возвращаются в хранилище vSAN, даже если оттуда удалены все файлы. Они могут повторно использоваться, когда новые данные будут записываться на тот же общий файловый ресурс.

    Resolve: Для возвращения этого хранилища в vSAN, следует удалить общие файловые ресурсы.

    • Issue: Исправление задачи кластера большого размера может сбоить из-за проблем с тестированием здоровья сети vSAN. Речь о кластерах с более чем 16-ю хостами и задачах обновления хоста. Тогда пинги не проходят, и обновление хоста в vSphere Life Cycle Manager прерывается.

    Resolve: После пре-чека отключить оповещения для следующих тестов vSAN:

      • vSAN: Basic (unicast) connectivity check
      • vSAN: MTU check (ping with large packet size).

    Когда обновление завершится, восстановить эти оповещения.

    • Issue: Хост сбоит в сценарии смены диска «на горячую», когда повторно вставляется диск. Когда диск NVMe извлекается таким образом и вставляется менее чем через минуту, хост падает.

    Resolve: Подождать более одной минуты.

    • Issue: Update Manager показывает ID теста вместо имени. В процессе использования Update Manager для обновления хостов в vSAN кластере, хелс-чеки vSAN могут выявить проблемы с ним и выдать сообщение, к примеру, вида:

    Before host exits MM, remediation failed because vSAN health check failed. vSAN cluster is not healthy because vSAN health check(s): com.vmware.vsan.health.test.controlleronhcl failed

    Resolve: Использовать службу проверки здоровья для идентификации и решения проблем. Затем запустить обновление хоста снова. Больше об использовании проверок здоровья vSAN при работе с vSphere Update Manager (VUM) можно почитать здесь.

    • Issue: Невозможно перевести последний хост в кластере в режим обслуживания, удалить диск или дисковую группу. Когда только один хост остался в кластере, а тот ушел на maintenance, операции в режиме «Full data migration» или «Ensure accessibility» могут завершаться ошибкой, не предложив добавить новый ресурс. Аналогичное случается, когда только один диск или дисковая группа остались в кластере, и их нужно удалить.

    Resolve: До перевода последней оставшейся в кластере ноды в режим обслуживания с выбранными опциями «Full data migration» и «Ensure accessibility», добавить другой хост такой же конфигурации в кластер. Перед удалением последнего оставшегося диска или дисковой группы, добавить новый диск или группу такой же конфигурации и емкости.

    • Issue: Рабочие процессы реконфигурации объектов могут фейлиться из-за недостатка емкости одного или большего количества дисков (дисковых групп), если они почти заполнены. Ресинхронизация vSAN становится на паузу, если диски в кластерах с дедупликацией или без нее достигают своих настраиваемых пороговых значений заполненности паузы ресинхронизации. Это сделано для того, чтобы избежать переполнения дисков при операциях ввода/вывода ресинхронизации. Останавливаются все рабочие процессы вроде EMM, восстановления, ребаланса и изменения политик.

    Resolve: Если в другом месте кластера все еще есть свободное пространство, выполнить повторную ребалансировку для освобождения места другим дискам. Тогда дальше реконфигурация пройдет успешно.

    • Issue: После восстановления из переполненного кластера виртуальные машины могут потерять HA-защиту. Если диски заполнены на 100% на хостах кластера vSAN, на ВМ подвисает вопрос и, следовательно, может утратиться защита НА. Также машины с подвисшим вопросом не защищаются НА после восстановления из полного кластерного сценария.

    Resolve: После восстановления в результате полного кластерного сценария vSAN выполнить одно из трех:

      • Выключить и включить НА;
      • Реконфигурировать НА;
      • Выключить и включить виртуальные машины.
    • Issue: Сбой выключения ВМ с «Question Pending». Если у машины есть неразрешенный вопрос, любые связанные с ней операции недоступны, пока на него не будет дан ответ.

    Resolve: Освободить дисковое пространство на соответствующем томе, после чего нажать «Retry».

    • Issue: При заполнении кластера IP-адреса ВМ меняются на IPV6 или становятся недоступными. При заполнении кластера vSAN (одна или несколько дисковых групп достигают 100%) задается вопрос к пользователю, требующий определенных его действий в качестве ответа. Если он остается нерешенным или не сделать что-то с заполненностью кластера, IP-адреса виртуальных машин сменятся на IPV6 или станут недоступны. Так было задумано, чтобы предотвратить использование доступа по SSH к ВМ. Консоль, кстати, аналогично недоступна: ввод пароля рута делает консоль пустой.

    Resolve: нет.

    • Issue: Не получается удалить группу дисков с включенной дедупликацией после перехода емкости диска в статус PDL. То же самое происходит, если поменять уникальный идентификатор диска, или же при выявлении устройством неустранимой аппаратной ошибки.

    Resolve: Каждый раз при удалении или изменении уникального идентификатора диска емкости, либо же при возникновении неисправимой аппаратной ошибки, подождать несколько минут и только затем пробовать удалить группу дисков.

    • Issue: Состояние vSAN показывает недоступность, связанную с несоответствием при проваленном запросе политики. Это часто случается, когда есть другая запланированная по графику работа, использующая запрошенные ресурсы. По мере того, как ресурсы высвобождаются, vSAN автоматически перестраивает график исполнения запроса этой политики.

    Resolve: Как правило, сканирование периода в vSAN устраняет эту проблему автоматически. Однако стоит учитывать, что прочие незавершенные действия могут нуждаться в доступных ресурсах даже после того, как политика была изменена, однако еще не успела примениться. В этом случае рекомендуется добавить емкость (если в отчете о емкости значения слишком высоки).

    • Issue: В кластерах с дедупликацией возвратная ребалансировка может не состояться, если диск показывает более 80% заполненности. Это случается потому, что в таких кластерах все, ожидающее записей или удалений, аналогично учитывается при калькуляции свободной емкости.

    Resolve: нет.

    • Issue: Из гостевой ОС команды TRIM/UNMAP не работают. Если гостевая операционная система пытается восстановить пространство при онлайн-консолидации во время снэпшота, введение команд TRIM/UNMAP завершается ошибкой. В результате место не освобождается.

    Resolve: Повторить операцию освобождения места после снятия снэпшота. Если и далее TRIM/UNMAP не работают, перемонтировать диск.

    • Issue: Ошибка на хосте при преобразовании хоста данных в хост-свидетель. При превращении кластера vSAN в растянутый кластер, обязательно нужно предоставить ему ноду-свидетеля. Однако в процессе приходится использовать режим maintenance с полной миграцией данных. Если же положить хост в режим обслуживания с опцией «Ensure accessibility» и инициировать конфигурирование ноды-свидетеля, хост падает в «экран смерти».

    Resolve: Удалить группу дисков на хосте-свидетеле, а затем заново их создать.

    • Issue: Виртуальная машина дублируется с таким же именем в vCenter Server, когда постоянный хост падает в процессе миграции хранилища данных. Если ВМ передает сторадж vMotion из vSAN на другое хранилище данных, к примеру, на NFS, и регистрируется падение хоста в сети vSAN (вызывая аварийное переключение НА на машине), она может продублироваться на vCenter Server.

    Resolve: Выключить невалидную виртуальную машину и снять ее регистрацию в vCenter Server.

    • Issue: Реконфигурация существующего растянутого кластера под новый vCenter Server вынуждает vSAN выдавать ошибку при проверке состояния (статус «красный»), вида:

    vSphere cluster members match vSAN cluster members

    Resolve: Проделать следующее:

      1. Подключиться по SSH к хосту-свидетелю;
      2. Декомиссовать диски на хосте-свидетеле, используя следующую команду:

    esxcli vsan storage remove -s “SSD UUID”

      1. Удалить хост-свидетель из кластера по силовому сценарию, командой:

    esxcli vsan cluster leave

      1. Реконфигурировать растянутый кластер из нового vCenter Server, пройдя по пути: «Configure > vSAN > Fault Domains & Stretched Cluster».
    • Issue: Не удается обновить формат диска во время ресинхронизации vSAN больших объектов. Ошибка вида:

    Failed to convert object(s) on vSAN

    Resolve: Дождаться завершения ресинхронизации, после проапгрейдить формат диска. Проверить статус ресинхронизации можно в «Monitor > vSAN > Resyncing Components».

    • Issue: Последовательная проверка состояния кластера завершается ошибкой во время операции «deep rekey», вида:

    Cluster configuration consistency

    Эта операция на зашифрованном vSAN-кластере может занять несколько часов. А традиционный хелс-чек не распознает ее, и поэтому выдает ошибку.

    Resolve: Провести повторный тест после «deep rekey».

    • Issue: Утеря конфигурации растянутого кластера vSAN после выключения vSAN на кластере. Пропадает конфигурация всего: и растянутого кластера, и хоста-свидетеля, и fault domain.

    Resolve: Реконфигурировать растянутый кластер после включения.

    • Issue: Выключенная ВМ показывается как недоступная при замене хоста-свидетеля. Такое отображается только краткий промежуток времени, а после завершения процесса вновь все проявляются. С запущенными все нормально.

    Resolve: нет. Рабочему процессу не вредит.

    • Issue: Не получается перевести хосты с неисправным загрузочным носителем в режим обслуживания. vSAN не может сохранить изменения в конфигурации, поэтому выдает ошибку. В логах пишется:

    Lost Connectivity to the device xxx backing the boot filesystem

    Resolve: Вручную переместить дисковые группы с каждого хоста, используя опцию «Full data evacuation». После положить хост в maintenance mode.

    • Issue: Служба проверки состояния не работает, если в кластере vSAN есть ESXi-хосты с vSphere 6.0 Update 1 или старше. vSAN 6.6 и свежее не работает с такими версиями.

    Resolve: Не добавлять хосты с такой версией среды или обновить хосты до более поздней версии.

    • Issue: После аварийного переключения растянутого кластера виртуальные машины на основном сайте регистрируют ошибку:

    Failed to failover

    Если второй сайт в растянутом кластере падает, ВМ должны аварийно переключаться на основной.

    Resolve: нет. Игнорировать. Не влияет на успешность аварийного переключения.

    • Issue: Во время создания партиций сети компоненты на активном сайте кажутся отсутствующими. В процессе деления сети в хосте vSAN или растянутом кластере в веб-клиенте vSphere отображается кластер с точки зрения неактивного сайта.

    Resolve: Использовать RVC-команды, чтобы проявить реальное состояние объектов (например, «vsan.vm_object_info»).

    • Issue: Некоторые объекты не отвечают требованиям после принудительного восстановления. Это случается потому, что в процессе собственник таких объектов был перемещен на другую ноду. Силовой метод восстановления для таких объектов может примениться с задержкой.

    Resolve: Выполнить принудительное восстановление после того, как все прочие объекты будут восстановлены и ресинхронизированы. Подождать, пока vSAN не доделает до конца эту работу.

    • Issue: При перемещении узла из одного зашифрованного кластера в другой, а затем назад, задача не выполняется. Ошибка вида:

    A general system error occurred: Invalid fault

    Так получается потому, что vSAN не в состоянии повторно зашифровать данные на узле, так как пытается использовать исходный ключ шифрования. Спустя немного времени исходный ключ на хосте восстанавливается, после чего все отключенные диски в кластере монтируются.

    Resolve: Перезагрузить хост и подождать, пока все диски не смонтируются.

    • Issue: Появляется дисбаланс растянутого кластера после восстановления сайта. Иногда при восстановлении сайта на растянутом кластере хосты с упавшего сайта возвращаются последовательно в течение долгого периода времени. vSAN может чрезмерно использовать некоторые хосты при восстановлении их утерянных компонентов.

    Resolve: Восстановить все хосты на отказавшем сайте вместе в свободном от операций окне.

    • Issue: Сбой операций ВМ из-за проблем с НА на растянутом кластере. В некоторых сценариях сбоя в растянутых кластерах затрагиваются определенные операции виртуальных машин (vMotion или включение машины). Такие сценарии могут включать частичное или полное падение сайта, отказ высокоскоростной связи между сайтами. Это возникает по причине зависимости от доступности VMware HA для нормальной работы сайтов растянутых кластеров.

    Resolve: Отключить vSphere HA до выполнения vMotion, создания виртуальных машин или их включения. Затем обратно включить.

    • Issue: Невозможно выполнить deep rekey отключенной дисковой группы. Дело в том, что перед deep rekey vSAN делает shallow rekey. А последний не умеет работать с демонтированными дисковыми группами. Соответственно, и deep rekey не стартует.

    Resolve: Перемонтировать или удалить отключенную дисковую группу.

    • Issue: Логи свидетельствуют, что конфигурация брандмауэра изменилась. Появляется новый вход брандмауэра в профиле безопасности при включенном шифровании vSAN («vsanEncryption»). Это правило контролирует, как хосты связываются напрямую с KMS. Когда такое случается в логи («/var/log/vobd.log») записывается следующее сообщение:

    Firewall configuration has changed. Operation ‘addIP4’ for rule set vsanEncryption succeeded.
    Firewall configuration has changed. Operation ‘removeIP4’ for rule set vsanEncryption succeeded.

    Resolve: нет. Можно игнорировать.

    • Issue: Отказ НА не случается после установки параметра «Traffic Type» на vmknic с целью поддержки трафика свидетеля.

    Resolve: Вручную отключить vSphere HA на кластере, а затем снова включить.

    • Issue: Не поддерживается iSCSI MCS. Целевая служба vSAN iSCSI не поддерживает Multiple Connections per Session (MCS).

    Resolve: нет.

    • Issue: Любой инициатор iSCSI может обнаруживать цели iSCSI.

    Resolve: Можно заизолировать свои ESXi-хосты от инициаторов iSCSI путем помещения их в отдельную VLAN.

    • Issue: После создания сетевого раздела, некоторые операции ВМ на связанных клонах могут фейлиться. Речь об операциях, которые не производят I/O. А именно: снятии снэпшотов и приостановке виртуальных машин. Это случается, когда сетевой раздел уже готов, а пространство имен родительской машины еще недоступно. Когда же оно станет доступным, НА не считает нужным включать такую ВМ.

    Resolve: Выключить и снова включить ВМ, которые неактивно используют операции ввода/вывода.

    • Issue: Нельзя перевести узел-свидетель в Maintenance Mode. Ошибка вида:

    A specified parameter was not correct

    Resolve: При инициации режима обслуживания для хоста-свидетеля выбрать опцию «No data migration».

    • Issue: Перемещение хоста-свидетеля в растянутый кластер и из него оставляет кластер в неправильно сконфигурированном состоянии.

    Resolve: Переместить witness-хост вовне растянутого кластера vSAN и переконфигурировать растянутый кластер. Подробнее почитать можно здесь.

    • Issue: Когда сетевая партиция появляется в кластере с НА heartbeat хранилищем данных, виртуальные машины не рестартуют на другом сайте данных. Если в vSAN-кластере для основного или вторичного сайта падает сетевое подключение к другим сайтам, работающие на них машины теряют сеть, но не перезапускаются на другом сайте. Ошибка вида:

    vSphere HA virtual machine HA failover failed

    Resolve: Когда конфигурируется vSphere HA на кластере, не выбирать НА heartbeat хранилище данных.

    • Issue: Отключенные диски и дисковые группы vSAN отображаются как подключенные в поле «Client Operational Status» веб-клиента vSphere. Если диски или дисковые группы отключены командой:

    esxcli vsan storage disk group unmount 

    или службой vSAN Device Monitor после демонстрации ими постоянных высоких задержек, веб-клиент vSphere некорректно показывает их статус («mounted»).

    Resolve: Использовать поле «Health» для проверки статуса дисков вместо поля «Client Operational Status».

    Если найдем еще какие-то интересные проблемы с vSAN 7.0U1, обязательно обновим этот материал. Как и в том случае, когда поймем, как решить задачи, на которые выше не было дано ответа.

    Avatar of Xeronimo

    Xeronimo

    Flag for Luxembourg asked on 10/3/2013

    Hi,

    I’ve upgraded my vCenter appliance to 5.5 and now the VMs of one of my cluster servers indicate this error message … the VMs on the other two cluster servers are just fine. Any ideas what this is about and how to resolve it?

    The actual virtual servers run fine though, they’re accessible, etc. It’s just that there is this error message in the vCenter client.

    Thank you!

    VMware

    Avatar of undefined

    Last Comment

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)


    8/22/2022 — Mon

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)

    10/3/2013

    This is sometimes — normal. (bug!)

    Can you check if all VMs are started on all your Hosts.

    Whats the HA status on the host housing the vm?

    hanccocka: all the VMs are started!

    dipopo: the HA status is ‘running (master)’

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)

    10/3/2013

    Yes, this error message occurs on all versions of VMware HA.

    e.g. 4.1, 5.0, 5.1 and 5.5

    Reconfigure each Host for HA — Reconfigure HA, or Disable Cluster and Re-enable. (eg. Edit Settings on Cluster, and remove Tick!)

    I’ve already reconfigured the HA on all the hosts, that didn’t remove the error messages. I’ll try to disable and reenable the cluster then …

    Ok, so now I’ve disable and re-enabled the cluster.

    The error messages on the VMs from that one host are still there though … is that normal? Should I simply clear and acknowledge them then?

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)

    10/3/2013

    Yes, it’s normal.

    You have checked HA works for you?

    Checked? You mean by shutting down one host to see if the others restart the VMs? No, not yet … I just didn’t get any error messages while disabling and re-enabling the cluster … is that not enough to be sure? ;)

    THIS SOLUTION ONLY AVAILABLE TO MEMBERS.

    View this solution by signing up for a free trial.

    Members can start a

    7-Day free trial

    and enjoy unlimited access to the platform.

    Yes, remove power is what I meant … but I can’t test that right now … those servers would be offline for a couple of minutes …

    If with toggling on/off you mean enabling/re-enabling the cluster option: I’ve done that and the servers still have a red flag next to them?

    Could you check to see if an attempt to vmotion a vm from the host throws up errors?

    I’ve migrated one of the VMs to a host where no VMs have this HA failure message … this VM keeps displaying that error though, even on the new machine! I guess the error message is not a ‘live’ one, it’s simply still displayed because of an earlier error?

    I think I’ll move all my VMs, except for a test VM, from the problematic host to a different host and then power off the first one and restart it. And then let’s see what it says …

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)

    10/4/2013

    If testing VMware HA — just remove the power to host.

    I’m, obviously, new to this cluster thing but just to be sure: since the VMs are stored on shared storage, will the other servers in the cluster immediately take over the virtual machines from the ‘failed’ host? Or do the VMs initially crash and the other servers will onlyx then immediately restart them? The former would be preferable though and make more sense …

    But what if the HA does not work on my problematic server then its VMs will surely crash, right? That’s why I thought to migrate my VMs for to a different host and then test the HA with one test VM running on it.

    Yes the latter holods true

     VMs initially crash and the other servers will only then immediately restart them? — 1-5 minutes.

    Ok, so I’ve tested it and the HA works! The test VM got restarted on a different host.

    Also, all the VMs indicating that HA failure message have «vSphere HA Protection: Protected’.

    So I guess I can move those VMs back to that server and simply clear the alarms?

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)

    10/4/2013

    Correct. Well Done, Most People do not test!

    Ok, and thank you for your help and also your compliment! :)

    Andrew Hancock (VMware vExpert PRO / EE Fellow/British Beekeeper)

    10/4/2013