Manuals and User Guides for King Long XMQ6129Y series. We have 1 King Long XMQ6129Y series manual available for free PDF download: Operating Manual
Technical parameter and complete vehicle description
Air conditioner control panel (SK-17-1)
Air conditioner (KL-XIY-J)
Select key introduction:
Power key
Select ensure key
Air speed select key
Fresh air select key
Up key
Down key
Temperature display
Control panel operation:
1) How to use the air conditioner
⑴
Start the engine
turn ON the cooling switch
⑵
⑶
set the suitable temperature
turn OFF the cooling switch
⑷
⑸
stop the unit
2) Temperature setting
COOLING——The system begins to cool
temperature inside the bus
——The system stops cooling if the set temperature is higher than (or equal to)
the temperature inside the bus
Indicator light introduction:
, push
——the setting temperature will be held automatically
for one second.
,push
if the set temperature is lower than the
P-A-1
low air speed
midterm air speed
high air speed
Cooling
Setting Temp
Pressure alarm indicator
Fresh air
Commonly used oil-in-water detection methods for online oil-in-water sensors include suspension method (D/λ<=1), infrared spectrophotometry (not applicable to low range), and ultraviolet spectrophotometry (not applicable to high range).
- Description
- Reviews (0)
Detection method:
Online oil in water sensor, Commonly used oil-in-water detection methods are suspension method (D/λ<=1), infrared spectrophotometry (not suitable for low range) and ultraviolet spectrophotometry (not suitable for high range).
Features Of Online oil-in-water sensor:
Using the principle of fluorescence. Compared with several commonly used methods, the fluorescence method is more efficient, faster, and can be monitored online in real time.
- Digital sensor, RS-485 output, support MODBUS.
- With automatic cleaning brush to eliminate the impact of oil on the measurement.
- Eliminate the effects of ambient light on measurements with unique optical and electronic filtering techniques.
- Unaffected by suspended solids in water.
Online oil-in-water Advantage:
The oil in water sensor has better repeatability and stability. The use of self-cleaning brushes can eliminate air bubbles, reduce the influence of pollution on the measurement, make the maintenance cycle longer, and maintain excellent stability for long-term online use. It can play an early warning role in oil pollution in water.
Scenes to be used:
It is suitable for water quality monitoring scenarios such as oil quality monitoring, industrial circulating water, condensate water, wastewater treatment, and surface water stations.
Online oil-in-water sensor principle:
The oil content in the water was monitored by ultraviolet fluorescence method, and the concentration of oil in the water was quantitatively analyzed according to the fluorescence intensity of the oil and its aromatic hydrocarbon compound and the conjugated double bond compound absorbing ultraviolet light.
The aromatic hydrocarbons in petroleum can generate fluorescence under the excitation of ultraviolet light, and calculate the value of oil in water according to the intensity of fluorescence.
Technical parameter:
Product | Oil in water sensor/Self-cleaning oil in water sensor |
---|---|
Model | DS530 |
Principle | Ultraviolet fluorescence method |
Range | 0-50ppm or 0`5000ppb |
Precision | 3% |
Resolution | 0.1ppm or 0.1ppb |
The detection limit | According to the actual oil sample |
Linearity | R2>0.999 |
Protection level | Ip68 |
Sensor interface | Support RS-485, MODBUS protocol |
Assembly | Input type |
Power information | DC 5~12V, current <50mA (when not cleaned) |
Size | Φ45*175.8 mm |
Probe cable length | 10 meters (default), can be customized |
Housing material | 316L (customizable titanium alloy) |
Self-cleaning Brush | No/Have |
Optical window | optical fiber |
OIL IN WATER SENSOR VIDEO:
Related Articles:
Common Application Fields of Desun Oil in Water Sensors
10 sets oil in water sensors and controllers will be sent to Russia
Get A Quote Now
KingSong EUCs Error Code | |
Error Code | Description |
*Note KS-S22 displays only last 2 digits of error code |
|
2235 | Sensor data is reversed, or line fault, this sensor has now been turned off. |
2236 | Sensor B is not connected or the sensor is damaged, the sensor has been closed for use. |
2237 | Sensor data A is reversed, this sensor is closed. |
2238 | Sensor A is not connected or the sensor is damaged, the sensor has been closed for use. |
2239 | The voltage is too high, please do not ride downhill for an extended time. |
2240 | The voltage is too high, please remove the charger. |
2241 | Low battery, please charge. |
2242 | Gyroscope error, please contact your seller and replacement motherboard. |
2243 | The output current of the main board has exceeded. Please check if the motor is damaged or if the phase line is shorted. |
2244 | Please check if the motor hall line connection and is functioning normally. |
2245 | No serial number or serial number error |
2246 | The motor temperature is too high, please stop and ride after the it has cooled down. |
2247 | The motherboard temperature is too high, please stop and ride after the it has cooled down. |
2248 | The output current is at max, please ride with caution. |
202 | Over Current or locked rotor. |
203 | The motor is blocked, please check whether the motor is rotating smoothly or remove obstacles before riding. |
205 | Drive Cruit is not functioning correctly, please restart or replace drive circuit. |
206 | The motherboard output wire has short circuited, please check whether the battery output wire has short circuited or whether the motherboard MOS is damaged. |
207 | Gyroscope failure, please replace motherboard. |
217 | Motor Hall sensor error, please check the hall ensor and repair accordingly. |
221 | Motor is experiencing high temperature, please allow Motor to cool down before riding again. |
222 | MOS is experiencing high temperature, please allow MOS to cool down before riding again. |
228 | Serial Number Error. |
218 | Overpower, please avoid over-accelerating or climbing steep hills. |
219 | Device is outputting at max. |
220 | Motherboard output over votlage, or motor is blocked. Please ride with caution. |
223 | Charging is over voltage or over current. |
229 | Low voltage, please charge your device! |
231 | Overvoltage, please beware of your safety and avoid riding downhill. |
232 | Lift switch is out of order, please release the handlebar or check whether the lift switch sensor has experienced a short circuit. |
230 | Reserve power is missing, please replace motherboard. |
1208 | mttool,vol err |
1209 | mttool,over time |
1210 | mttool,block err |
1211 | mttool,speed err |
208 | the coef of batvol have no just |
227 | BMS get no data |
226 | BMS Warnning |
105 | be voltage detect need calibration |
224 | The battery reaches the preset charging value |
BMS Error Code | |
Error Code | Description |
5001 | Hardware short-circuit and software short-circuit protection instructions and solutions: battery protection circuit short-circuit protection, please stop using the machine immediately, check where there is a short-circuit problem, unplug the charger, stop riding, stand or turn off for 1 minute, etc. After checking, if it can't Back to normal, need to be repaired. |
5002 | Over-charging protection instructions and solutions: If the charging current of the battery exceeds (reference value: 7A), please stop charging immediately, unplug the charger, wait for about 1 minute, and the machine will automatically release the protection. |
5003 | Over-discharge protection instructions and solutions: If the battery discharge current exceeds (reference value: 40A), please stop the machine immediately, or you can also plug in the charger to charge, wait for about 10S, and the machine will automatically release the protection. |
5004 | Single-cell overvoltage protection description and treatment plan: If the voltage of the single-cell battery exceeds (reference value: 4.25V), please stop charging immediately, remove the charger for 10S, or run the machine, and wait for the voltage to drop below (4.15V), then The machine will automatically release the protection. |
5005 | Total voltage over-discharge protection description and treatment plan: If the total battery voltage is lower than (reference value: 72.0V), please stop using the machine immediately, and charge the machine in time. When the total voltage is higher than the recovery voltage (90V), the machine will automatically release Protect. |
5006 | Ambient low temperature, high ambient temperature Protection instructions and treatment plan: battery temperature The ambient temperature (reference value: -30℃~70℃) has seriously exceeded the battery protection limit. Please immediately improve the ambient temperature where the battery is located. |
5007 | High temperature discharge protection instructions and treatment plan: When the battery temperature is higher than (reference value: 60°C) during discharge, please stop using the machine immediately. When the temperature is lower than 50°C, the machine will automatically release the protection. |
5008 | High temperature charging protection instructions and solutions: If the charging temperature of the battery exceeds (reference value: 45°C), please stop charging immediately. When the temperature is lower than 40°C, the machine will automatically release the protection. |
5009 | MOSFET high temperature Protection instructions and treatment plan: The charging or discharging circuit temperature (reference value: 95℃) is seriously higher than the battery protection limit, please stop charging or stop using the machine immediately and wait for recovery. |
5024 | Total voltage and overvoltage protection instructions and solutions: when charging, the total voltage is higher than (reference value: 126.5V), please stop charging immediately, remove the charger for 10S, or run the machine, wait for the voltage to drop below (124.5V) , the machine will automatically release the protection. |
5025 | Single-cell over-discharge protection instructions and solutions: If the voltage of the single-cell battery is lower than (reference value: 2.50V), charge the machine in time. When the minimum single-cell voltage is higher than the recovery voltage (3V), the machine will automatically release the protection. |
5027 | Discharge low temperature protection instructions and treatment plan: When the battery temperature is lower than (reference value: -20℃) during discharge, please stop using the machine immediately and improve the ambient temperature where the battery is located. When the temperature is higher than -10℃, the machine will automatically release the protection . |
5028 | Low charging temperature Protection instructions and treatment plan: If the charging temperature of the battery is lower than (reference value: -5℃), please stop charging and improve the ambient temperature where the battery is located. When the temperature is higher than 0℃, the machine will automatically release the protection. |
5010 | Sampling failure, cell failure Fault description and solution: There is a failure in the protection board circuit, please stop using the machine immediately, check and repair it. |
5011 | NTC fault Fault description and solution: The temperature sensor is faulty. If it cannot be recovered, it needs to be repaired. |
5012 | Charging MOS fault Fault description and solution: If the charging circuit of the protection board is faulty, please stop using the machine and check and repair. The method of automatic recovery of charging MOS fault: plug in the charger, after 2~5 seconds, under normal circumstances, the fault will be automatically eliminated. |
5033 | Working power failure Fault description and solution: If the working power supply of the protection board is faulty, please stop using the machine immediately and check and repair it. |
5013 | Total voltage and low voltage alarm description and processing plan: the total voltage (reference value: 90.0V~126.2V) is low (less than 90V), please charge it in time, and when the single voltage is higher than 3V and the total voltage is higher than 90V, the alarm will be displayed. automatically eliminated. |
5014 | Total voltage and overvoltage alarm description and solution: the total voltage (reference value: 90.0V~126.2V) is too high (greater than 126.2V), please stop charging in time, and use it normally. After the total voltage is lower than 126.2V, the alarm will be issued will be automatically removed. |
5034 | MOS high temperature Alarm description and solution: Please confirm whether the MOS temperature is higher than (reference value: 90°C) in time. First, stop the machine from working, stop charging, and wait for a period of time. When the MOS temperature is lower than 90°C, the alarm will be automatically cleared. |
5035 | Ambient low temperature and high ambient temperature Alarm description and solution: The ambient temperature of the battery (reference value: -20°C~65°C) exceeds the limit, please confirm the ambient temperature of the machine in time, and select the charging at the appropriate temperature or riding environment. |
5036 | Discharge low temperature, discharge high temperature Alarm description and solution: The battery temperature (reference value: -10℃~57℃) exceeds the limit, please stop using the machine in time, or reduce the power consumption of the machine. |
5037 | Charging low temperature, charging high temperature Alarm description and solution: The battery temperature (reference value: 3℃~45℃) exceeds the limit, please stop charging in time, or check whether the charging current (reference value: 8A) is too large. |
5038 | Discharge overcurrent Alarm description and solution: Please confirm in time that the discharge current of the left and right batteries exceeds -35A (the negative sign indicates discharge). As long as the current is less than 35A, the alarm can be automatically eliminated. |
5039 | Charging overcurrent alarm description and solution: Please confirm whether the charging current (reference value: 6A) is too large (greater than 6A) in time, as long as the charging current is less than 6A, or stop charging, the alarm can be automatically eliminated. |
5015 | Cell low voltage Alarm description and solution: The single battery voltage (reference value: 3.000V~4.22V) is low (less than 3V), please charge it in time, wait until the single cell voltage is higher than 3V and the total voltage is higher than 90V , the alarm will be automatically cleared. |
5016 | Low battery alarm Alarm description and solution: The battery is low (reference value: 10%), please charge it in time, and the alarm will be automatically cleared when the battery power is higher than 10%. |
5017 | Cell high voltage Alarm description and solution: The single battery voltage (reference value: 3.000V~4.22V) is too high (greater than 4.22V), please stop charging in time, and use it normally, and wait until the single battery voltage is lower than 4.22V , the alarm will be automatically cleared. |
5018 | Discharge high temperature Alarm description and solution: When the battery temperature exceeds 90°C when riding or the motor is running, please stop riding or stop using the machine in time. When the temperature is lower than 90°C, the alarm will be automatically cleared. |
5019 | Charging high temperature Alarm description and solution: When the battery temperature exceeds 40℃ during charging, please stop charging in time, or strengthen the heat dissipation of the machine. When the temperature is lower than 40℃, the alarm will be automatically cleared. |
Last updated on January 30, 2023
-
Привет. Кажется, ты используешь AdBlock. Наш форум развивается и существует за счет доходов от рекламы. Добавь нас в исключения =)
КАК ДОБАВИТЬ?
-
Ответить в тему
-
Создать тему
Рекомендованные сообщения
- Жалоба
-
#1
Всем Доброго дня! Такая проблема…Месяц назад на 9G5030 периодически при работе вылетала ошибка Water error…по совету форума замкнул два провода черных на датчике воды всё стало работать вновь.. без проблем. Но вот уже два дня..при запуске станка вновь вылетает Water error.. проводки от датчика надёжно скручены…при сбросе и запуске..начинает работать 1-5 сек. и вновь Water error…Что проверить или сделать?…луч идёт только с кнопки тест блока розжига трубки..можно ли снять датчик… а два шланга с него соединить между собой, понимаю неправильно..но это временно.Всё циркулирует через чиллер 3000…
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#2
Нет ничего более постоянного чем временное!!) К тому же новогодняя пора, ажиотаж. Ну уберете вы датчик (это лементарно), потом окажется, что дело не в нем, а в недостатке давления. Сожгете трубу, будет фейверк на НГ. Проверьте напор (давление). Вы когда шланг пережимаете чиллер пищит?
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
Награды пользователя
- Жалоба
-
#3
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#4
Снимите шланг и проверьте напор. Вода вообще циркулирует? Я вот не помню, ваш чиллер оснащен звуковым сигналом!
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
Награды пользователя
- Жалоба
-
#5
В настройках отключите water protect
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#6
@PavelK МОЖНО УЗНАТЬ ГДЕ И КАК ОТКЛЮЧИТЬ… ВРУЧНУЮ ЧЕРЕЗ ДИСПЛЕЙ СТАНКА ИЛИ В ПРОГРАММЕ LASERWORK?
@PavelK МОЖНО УЗНАТЬ ГДЕ И КАК ОТКЛЮЧИТЬ… ВРУЧНУЮ ЧЕРЕЗ ДИСПЛЕЙ СТАНКА ИЛИ В ПРОГРАММЕ LASERWORK?
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#7
В LaserWork, где на память не помню, могу вечером глянуть.
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#8
@008shadow проверю вечером циркуляцию…есть какой-нить совет чем прочистить или какое средство прогнать через чиллер, чтобы лучше циркулировала?
@PavelK да было бы хорошо узнать и написать ..как отключить…весь форум перерыл,,, да пишут отключить water protect.. но как это сделать и где инфы нет…а ещё лучше скрин по-возможности
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#9
15 минут назад, Lazerboy сказал:
а ещё лучше скрин по-возможности
Так же! Проги под рукой нет(
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
Награды пользователя
- Жалоба
-
#10
Все обыскал в проге станка…не найти water protec(..
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#11
Я бы все же проводочки то, идущие к датчику прозвонила бы..:)
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#12
ВОПРОС РЕШЕН…ПРОВОДА ОТ ДАТЧИКА ВОДЫ ПЛОХО СКРУТИЛ МЕЖДУ СОБОЙ….НО КАК УЗНАТЬ КАК ЕГО ЧЕРЕЗ ПРОГРАММУ БЫЛО БЫ ИНТЕРЕСНО!
ЭТО Я ПРО ДАТЧИК ВОДЫ..
ОТКЛЮЧИТЬ..
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#13
В LaserWork:
Вверху в менюшке Config -> System Settings -> вкладка Machine param -> нажать Read -> в списке изменить пункт Water protection -> нажать Write
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#14
- Цитата
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
- Жалоба
-
#15
Поделиться сообщением
Ссылка на сообщение
Поделиться на других сайтах
Присоединяйтесь к обсуждению
Вы можете опубликовать сообщение сейчас, а зарегистрироваться позже.
Если у вас есть аккаунт, войдите в него для написания от своего имени.
-
Сейчас на странице
0 пользователей
Нет пользователей, просматривающих эту страницу.